Compound microscope (Hund)



Similar documents
Care and Use of the Compound Microscope

MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.

MT-30 & MT-90 Series. Advanced Academic Microscopes/ Advanced Academic Polarizing Microscope INSTRUCTION MANUAL

EXPERIMENT #1: MICROSCOPY

Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure

MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY

Microscope Lab Introduction to the Microscope Lab Activity

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

How To Use An Asbestos Microscope

THE COMPOUND MICROSCOPE

Exercise 2. The Compound Light Microscope

Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES

OPERATING INSTRUCTIONS XJL 101/101A REFLECTED LIGHT METALLURGICAL MICROSCOPE

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012

BIO 10 Lab 1 Introduction Pre Lab Test

HISTOLOGY LABORATORY. Microscope Orientation and Blood Smear Lab

Use of the Microscope and Cytology

National Optical & Scientific Instrument Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University

MICROSCOPES & REFRACTOMETERS for laboratory, industry and food

Microscopes and the Metric System

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

ST-80 MICROSCOPE With Electronic Eyepiece #6810. User Guide

A new advance in routine inspections INVERTED MICROSCOPE CKX41/CKX31

LAB 3 Use of the Microscope

Microscopy and Cellular Morphology

euromex microscopen bv The Netherlands page1/16

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

ISO9001 ISO Environmentally-friendly product All optical components in CX41 microscope use lead-free eco-glass.

Protocol for Microscope Calibration

CALIBRATION FOR LAL20X & LAL24X

The illustrations below reflect other scientists results in identifying and counting the stages of the onion root tip and the whitefish blastula.

To measure an object length, note the number of divisions spanned by the object then multiply by the conversion factor for the magnification used.

3.1 Cells and cell function

VICKERS HARDNESS TESTER. HBS HBW Kc

Measuring. User Manual

GLobAL Dental Microscopes. Dentists First Choice

How to make a Galileian Telescope

Features: Mounting the Optic

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

MALARIA PARASITE COUNTING

OLYMPUS SYSTEM MICROSCOPE. Model BHT OLYMPUS

A Fishy Tale. Observing the Circulatory System of a Goldfish with a Compound Light Microscope

The Applied Imaging Cytogenetic Workstation

1. Examine the metric ruler. This ruler is 1 meter long. The distance between two of the lines with numbers on this ruler is 1 centimeter.

Photovoltaic Cell: Converting Light to Electricity

Animal & Plant Cell Slides

Main Library Meeting Room Use

The How Do Guide to AxioVision. Author: Brian Svedberg Image Analysis Specialist Carl Zeiss MicroImaging, Inc.

User Guide LUXXOR VIDEO MICROSCOPE. 2 Luxxor Video Microscope Set Up

VISM Evolution Scope Series

Review: Amscope Metallurgical Trinocular Microscope. Michael Reese Much FRMS EMS Bethlehem, Pennsylvania USA

LABORATORY MICROSCOPEs

COMPARING PLANT AND ANIMAL CELLS

MICROSCOPE & OPTICAL CATALOG

RESEARCH MACRO ZOOM SYSTEM MICROSCOPE MVX10. Macro View. The first true macro fluorescence imaging system

Lecture 17. Image formation Ray tracing Calculation. Lenses Convex Concave. Mirrors Convex Concave. Optical instruments

Cells. Introduction WSBCTC 1

OLYMPUS STUDENT MICROSCOPES IINSTRUCTION MANUAL I CBA& CBB MODELS

Geometric Optics Converging Lenses and Mirrors Physics Lab IV

Light and its effects

CX21 INSTRUCTIONS EDUCATION MICROSCOPE IVD

PlaneWave CDK Telescope Instructions CDK12.5, 17, 20 and 24

Installation and use of Millett Tactical TRS-1 and TRS-2 scopes TRS-1 TRS-2. Before starting, make sure firearm is UNLOADED!!

MENG 302L Lab 1: Hardness Testing

OBJECTIVES PROCEDURE. Lab 2- Bio 160. Name:

Comparing Plant and Animal Cells

Leica DM300 User Manual

Installation Instructions

Rauserv Steam Sterilizers, Laboratory and Hospital Equipment. Brewery Laboratory Equipment

OLYMPUS STUDENT MICROSCOPES INSTRUCTIONS ST. HS&HSC MODELS OLYMPUS

Leica DM500 & DM750. A New Generation s Choice of Innovative Educational Microscopes

Experiment #12: The Bohr Atom. Equipment: Spectroscope Hydrogen and Helium Gas Discharge Tubes, Holder, and Variac Flashlight

Solution Derivations for Capa #14

VISM CQB Scope Series

Atomic Force Microscope

EXPERIMENT 6 OPTICS: FOCAL LENGTH OF A LENS

2) A convex lens is known as a diverging lens and a concave lens is known as a converging lens. Answer: FALSE Diff: 1 Var: 1 Page Ref: Sec.

FirstView 3 Reflector Telescope Owner s Manual

Urinalysis and Body Fluids CRg

MACRO PHOTO LENS. MP-E 65mm f/ ENG. Instruction

9/16 Optics 1 /11 GEOMETRIC OPTICS

LOUPES AND HEADLIGHTS HEADLIGHTS. HEINE Headlights. Type of Light LED LED F.O. Light Intensity (at 250 mm working distance)

Basics to Using the View Camera

Operator s Maintenance Manual STEINER BINOCULARS. Military ruggedness and precision 07/03

Prokaryotic and Eukaryotic Cells

M A R C O. CP-670 AUTOMATIC CHART PROJECTOR Instruction Manual

CHAPTER 3 OBSERVING MICROORGANISMS THROUGH A MICROSCOPE. I. UNITS OF MEASUREMENT - See Table 3.1 in text. + Fig. 3.2

First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between

Biological Microscope. Biological Microscope ECLIPSE E200

PORTABLE PA SYSTEM #1 LAST UPDATED: FEBRUARY 2011

Be careful not to scratch or hit front edge of the side viewing micro prisms onto hard objects!

Institut für Experimentelle Immunologie und Bildgebung

GLOSSARY of STAINS Hematoxylin and Eosin (H&E) Periodic acid-schiff s (PAS) Masson s Trichrome Stain Gomori Trichrome Stain Silver Salts

Microscopes 2014 Microscopes PB Microscopes 1

CALIBRATING YOUR SYSTEM. Follow our guidelines carefully to ensure proper system function. EQUIPMENT

The upright transmitted microscope is most suited to our purpose of observing samples of compost, soil and compost tea, etc.

IMPORTANT. 2. Avoid the use of the microscope in direct sunlight, high temperature and humidity, dust and vibration.

Transcription:

1 2 3 4 5 6 7 8 9 10 11 12 13 14 Compound microscope (Hund) 15 16 17 18 19 20 1) Eyepieces (magnifies 10x), one with diopter adjustment, 2) Interp[upillary adjustment, 3) Head, 4) Revolving nosepiece, 5) Objectives (magnifies 4, 10, 40x, or 100x), 6) Slide holder, 7) Stage, 8) Iris diaphragm adjustment knob, 9) Light condenser, 10) Blue filter holder, 11) Condenser height adjustment knob, 12) Light source opening, 13) Field diaphragm adjustment, 14) Base, 15) Eyepiece diopter adjustment, 16) Stand, 17) Stage movement knobs, 18) Coarse focus knob, 19) Fine focus knob, 20) Light on/off switch & brightness

Compound microscope (Motic) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1) Eyepieces (magnifies 10x) diopter adjustment, 2) Interpupillary adjustment, 3) Head, 4) Revolving nosepiece, 5) Objectives (magnify 4x, 10x, 20x, 40x, or 100x), 6) Slide holder, 7) Stage, 8) Iris diaphragm adjustment knob, 9) Light condenser, phase contrast see below, 10) Condenser height adjustment knob, 11) Field diaphragm adjustment, 12) Stand, 13) Light on/off switch, 14) Light intensity knob, 15) Stage movement knobs, 16) Fine focus knob, 17) Course focus knob, 18) Base

The Motic microscope (room 1660) is very similar to the Hund microscope (room 1325) except that they are equipped with a phase contrast condenser. It is important the condenser turret be set at BF for Bright Field or the number setting corresponding to the objective in use to get phase contrast effects. When done, please remove slide, return the turret to BF, and put the 4X objective back in place. Phase contrast works great for small cells or unstained or very thin sections

Leave dust cover in cabinet Lift microscope with one hand on base, other on stand Gently set microscope down on counter Plug in, turn on and adjust light intensity about half way Open field and iris diaphragm about half way Put the red coded 4x objective in place (gives 40x magnification) Put slide on stage using clip holder Condenser should be just below stage (arrow on knob pointing up for Motics) Move stage using knobs so light shines through specimen Eyepieces diopter set at 0 for Motic or 65 for Hund (line up number with white line) Set eyepiece distance between for your eyes Look though eyepiece and focus on specimen using course focus knob Turn revolving nose piece to yellow coded 10X objective to give 100x magn. Use fine focus, turn to 40X objective (400x magn.) and fine focus as necessary Turn off light, unplug cord but please do NOT wrap it around microscope Put microscope back in same cabinet with the same dust cover on Set-up and care

Step 1 (same as when using the dissection microscope): Measure two points on your drawing with the ruler from your student drawer. Make a horizontal line the same length beside the word Scale:. Step 2: Look at the actual specimen through the microscope and, using the ruler (ocular micrometer) in the right eyepiece, count the number of eyepiece divisions (epd) across same two points (this eyepiece ruler has no units - there are simply 100 eyepiece divisions on it). Multiply the epd by the corresponding number of micrometers given in the table below depending on which objective is in use to determine the width or length of the specimen in micrometers: Objective Magnification 1 epd = 4X x40 25 µm 10X x100 10 µm 20X * x200 5.0 µm 40X x400 2.5 µm 100X x1000 1.0 µm Example: view & draw a happy plant cell: Step 1: Draw a line beside the word Scale: the same width as you drew the cell: Scale: Step 2: Measure the actual cell width using eyepiece ruler. Multiply the number of eyepiece divisions by the number of micrometers that correspond to the objective in use e.g. using 10X objective: 4 epd x 10 µm = 40 µm Indicate scale beside drawing as: Scale: 40 µm Note: This calibration was accomplished using a stage micrometer ruler 1 mm long divided into 0.01 mm (= 10 µm) markings mounted on a slide. * 20X objectives found on Motic scopes only and not all Hund scopes have x1000 Determination of scale using compound microscope