Industrial infrared heater IR For premises with large volumes and high ceilings



Similar documents
Classic Tylö sauna heaters for domestic use.

AUGUST 2007 Cl/SFB (56) outdoor heating. Feeling comfortable outside, whatever the weather

HDA

The space saving solution.

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

UDSA - UDSBD unit heater

INFRARED RADIANT HEATERS. air heaters

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

INFRARED QUARTZ WALL HEATER

Ducoterra Radiant Heating Panel Installation Manual

W 36: Mastering complex tasks reliably

K17.12 Door closers K17. Doors

8146/5 Series Breaker Panelboards

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

KATO. LED Lighting High Bay und Low Bay

HERZ-Thermal Actuators

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

marine/bespoke split applications

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

Radiant Temperature Sensor TY7321

HEAVY DUTY STORAGE GAS

Aluminium Standard. Technical Data. Included in delivery

Installation, operation and maintenance manual TX 35A

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Split units TH with hermetic compressors

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

BER Assessors Dwellings Technical Bulletin

How To Use A Ds340 (Dsp)

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

Superlight Compact Nano

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Itho Products for Hot and Boiling water. product-

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

FULL DC INVERTER SYSTEMS

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Fan heater Panther 6-15 Efficient fan heater for medium size premises

New XUY roller sensors

CADB and CADT-D / DI / DC Series

Cross-beam scanning system to detect slim objects. 100 mm in

Collision Prevention and Area Monitoring with the LMS Laser Measurement System

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Displacement ventilation

york air-conditioning products Residential & VRF News 2015

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

PUNKT LAMP 150 Design: focus lighting

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

RPV - RP - RA air handling units

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

Linear Luminaire with LED Series EXLUX 6402/2

Portable Air Conditioner

Heating Solutions Space and Water Heating

We have been working in an ideal climate for thirty years.

Industrial Linergy LED

Superlight Compact LED LED floodlights

Guide to Safety Edge Systems

W150: Miniature photoelectric switch series with completely integrated electronics

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

BROWACOM PRODUCTS. Our web-pages can be found from:

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

Flexit Central Vacuum Cleaner

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

IMPULSE SEALERS AM Y

SECTION MORTUARY REFRIGERATORS

CHARGING STATIONS FOR ELECTRIC VEHICLES QUICK CHARGER

Flush-mounted room thermostats

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Instructions for designing heating systems.

556/586 NEW NEW. One step closer to the fire.

Transformer oil cooler ALFA A02

Flexit Central Vacuum Cleaner

CHAPTER CONTENT PAGE. Hybrid: The perfect solution for all systems. Explanation of the - Heat Exchanger 4. Finishes 12

The solution for Europe: Type 2 charging socket with or without shutter

NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!

ECOCIAT. Domestic hot water heat recovery unit

Page 162. Page 154. Page 158 Page 146. Page 157. Page 152. Page 160. Page 149. Page 159. Page 156. Page 150

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Commercial Portable Air Conditioners

SERVER ROOM CABINET INSTALLATION CONCEPTS

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

5W LED Energy Saver PIR Bulkhead

Quartzone Infrared Quartz Tube & Metal Sheathed Electric Heaters

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013

Room Temperature Sensors

Nightscape High performance floodlights and spotlights for discharge lamps

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

KONRAD. Hybrid Fancoil Series

Railtrac A unique, flexible, multi-purpose system for welding and cutting. G lobal solutions for local customers everywhere

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI

Transcription:

3 3000 6000 W Electrical heat 3 models Industrial infrared heater For premises with large volumes and high ceilings Application is suitabe for total or supplementary heating of premises with large volume and high ceilings. It can also be used outdoors for example on sport arena stands or to keep loading bays dry and frostless. Comfort Radiant heaters give an efficient and pleasant heat in the dwelling zone and individual comfort can be created with spot and zone heating. o moving parts mean a silent system that does not cause air movements and a hygienic indoor climate is created when the spread of dust, bacteria or odours is reduced. Product specifications Reflectors of shiny anodised aluminium for optimal heat distribution. The mounting hinges allow the heater to be angled in five different positions. Connection plinth which allows for connection of a regulator or for serial connection of several heaters. Protection grille is available as an accessory. Casing of grey alu-zinc coated steel panels, very resistant against corrosion. Operation and economy Radiant heaters have an easy and flexible installation and require a minimum of maintenance. They give instant heat and no preheating is necessary. Radiant heaters can give cost savings of up to 25 % compared to convector heaters, especially in buildings with high ceilings that are used on an irregular basis. Design has a robust industrial design. Installation height 4,5 20 m 4 6 m Design and specifications are subject to change without notice. 2014-03-10

This train station outside Stockholm is heated by. A control with timer allow waiting passengers to increase the heat when it is particularly cold. The heater can be mounted in an angeled position to direct the heating where it is needed. Heaters used outdoors should be placed under a roof. In this installation the working stations are heated by heaters in the ceiling and C heaters on the wall. To divide a large hall into different zones is very energy effective especially in buildings where each zone is sporadically used. Protection grille G, available as an accessory, can be used to protect the heater in for example sports centres. The temperature can be adapted perfectly in different areas of a room with. Spot heating increases the comfort and lowers the heating costs. Temperature contribution t op = t room + t rad. 2 [ t rad. ] 40 C 35 C 30 C 25 C 4500 Installation height 2 m 3 m 4 m 20 C 15 C 10 C [m] - 2-1,5-1 - 0,5 0 0,5 1 1,5 2

Technical specifications Industrial infrared heater 3 Type Output stages [kw] Voltage [V] Amperage [A] Max. element temperature [ C] Dimensions LxHxW Weight [kg] 3000 1/2/3 400V3~* 1 4,3 700 1125x83x358 9.0 4500 1.5/3/4.5 400V3~* 1 6,5 700 1500x83x358 11.1 6000 2/4/6 400V3~* 1 8,7 700 1875x83x358 13.2 *¹) Can also be connected 400V3~, but then without output stages. With neutral, one element tube at a time can be connected. Protection class: IP44. Approved by SEMKO and CE compliant. Dimensions Type 3000 600 1125 4500 900 1500 6000 1200 1875 Positioning, mounting and installation Positioning For spot heating, the infrared heaters should be positioned so that people get heat from the front and from behind. The distance to the head should not be less than 2 metres. Read more in the Technical handbook. Mounting is delivered with mounting brackets and can be mounted directly on the ceiling or the wall. The mounting allow the radiation angle to be adjusted 30 in each direction. The heaters can also be suspended from wire (minimum Ø 3 mm). should always be mounted with the tube elements in an horizontal position. Protection grille G is available as an accessory. For minimum mounting distance, see Fig. 1. Connection is intended for permanent installation. In the terminal box are double connection plinths for cables of up to 16 mm². This allows for serial connection. Minimum distance Ceiling A 400 Wall, long side of the unit B 400 Wall, short side of the unit C 400 Flammable material D 700 Floor E 2300 Fig. 1: Minimum distance for fixed installation.

Control options Accessories Control by thermostat, contactor and switch (and timer) The choice of thermostat depends on needs and environment. Connection is made by a 3-step switch making it possible to manually connect the elements 1 + 1 + 1. Timer can be set to desired time. G, protecion grille Can be used to protect the heaters in sport centres. Available in three dimensions to fit each of the models. T10S, electronic thermostat with concealed knob TK10S, electronic thermostat with visible knob KRT1900, capillary tube thermostat, IP55 S123, manual switch for 1-2-3 output steps CBT, timer For further information and options, see the "Controls" section. Controls and other accessories Type Description HxWxD T10S Electronic thermostat with concealed knob 80x80x31 TK10S Electronic thermostat with visible knob 80x80x31 KRT1900 Capillary room thermostat, IP55 165x57x60 S123 Manual switch for 1-2-3 output steps 72x64x46 CBT Timer 155x87x43 G3000 Protection grille 3000 869x362x40 G4500 Protection grille 4500 1235x362x40 G6000 Protection grille 6000 1615x362x40

Heat contribution Heat contribution directly below 4.5-6 kw Heat contribution [ C] 250 200 A 150 2A 100 50 0 0 0.5 1 1.5 2 2.5 3 Distance to [m] Radiant heat contribution 4,5 kw Radiant heat contribution 6 kw Output [W/m²] Radiant heat contribution [ C] Radiant heat contribution [ C] Height above measure point [m] A-distance between the heaters [m]

Wiring diagrams Internal wiring diagram 3000, 4500, 6000 400V3~ Control by thermostat, contactor and switch Thermostat 230V~ L 400V3~ 3/3 X XX 2/3X X 1/3X 0 1 S123 L 1 L 1 Control with timer CBT L 1 230V~ L 400V3~ L 1 L 1 Design and specifications are subject to change without notice.