Rotary Disconnect Switch Specifications



Similar documents
Bimetallic Overload Relay Specifications

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

1756 ControlLogix Chassis Specifications

SMC -3 Specifications

Selection Guide. Bulletin 194R/140U External Operating Handles

CompactLogix Power Supplies Specifications

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

1788 Linking Device Specifications

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Circuit Breakers. Next Generation of Protection Capabilities

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

End of Life: 1494V Variable-depth Disconnect Switch ( A) End of Life: 1494C Cable-operated. Product Lifecycle

PSR The compact range Description

Electronic overload relay EF19 and EF45

Breakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Three-phase monitoring relay CM-PFE

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Plug and Socket Devices CES 63 A Series 8579

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic overload relay EF65, EF96 and EF146

Manual motor starter MS116

SPEEDFAX TM 2011 Disconnect Switches Contents

R.C.C.B. s two-pole LEXIC

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Legacy PanelView to PanelView Plus 6 Catalog Number Conversions

Bulletin 1489 Circuit Breakers. Selection Guide

Catalog January. Heavy industrial power applications Motor contactors and starters

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Micro800 Programmable Controllers. Bulletin 2080 Selection Guide

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Series 8146/5-V37 and Series 8150/5-V37

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

USB-to-Data Highway Plus Cable

Technical catalogue. Modular DIN rail components Installation contactors

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Phone: Fax: Web: info@clrwtr.com

Actuator-Sensor-Interface

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Catalog. Modular DIN rail components Installation contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

Type: DILM32 10(24V50HZ) Article No.:

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Terminal Blocks & Power Distribution Terminal Blocks. Make your connection

Safety technique. Emergency stop module BO 5988 safemaster

Tmax MCCBs. Molded case circuit breakers. Tmax

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Analog signal converters CC-E I/I Current / current isolators

TX OPEN RS232/485 module

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Absolute Rotary Encoder E6CP

D-Line Contactors, Overload Relays and Accessories

Thyristor-controlled power supplies and battery chargers

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

ADM1TE 5/30A DIN rail single phase two wire energy meter

Distribution Dry Type Transformers

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Type: DILM9 10(24VDC) Article No.:

RM4TG20 three-phase network control relay RM4-T - range V

FUSERBLOC. 20 to 1250 A Manual operation. 142 General Catalogue SOCOMEC. Fuse combination switches

Application Technique. Safety Function: Magnetic Door Switch Monitoring

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Technicaldata General

80 Series - Modular timers 16 A. Features

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

5SV Residual Current Protective Devices

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

MicroLogix 1100 Embedded Web Server

1321 Power Conditioning Products

Power Supplies 3. SDN-P DIN Rail Series

Safety Function: Door Monitoring

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Waveguide Access Point WGA631. Product Guide

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Low Voltage Disconnect Switches. NFPA79 and UL508A Industrial Machinery Operating Handle Requirements White Paper

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Low Voltage Products. Switches Automatic Transfer Switches

CQM1-SF200/CS1W-SF200

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Control Devices Catalogue. Control Devices. Preferred and Standard Products

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

Manual Motor Starter MS 116 up to 16 A Technical Data

Modan 3000 ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER. Systems Products and Services. Motor Control Centers Modan 3000

Transcription:

Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Resource Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Product Certifications website, http://www.ab.com Description Provides general guidelines for installing a Rockwell Automation industrial system. Provides declarations of conformity, certificates, and other certification details. You can view or download publications at http://www.rockwellautomation.com/literature/. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative.

194R Rotary Disconnect Switches Product Overview Bulletin 194R Overview Bulletin 194R-C, J, H, B, D, F, L, N, NU Bulletin 194R-NE Product Type Fused and non-fused rotary disconnect switches Non-fused IEC rotary disconnect switches Current Range 10 A 100 1 A Main Applications Functionality UL 98 ratings "suitable as service entrance disconnecting means" UL 508, CSA ratings "suitable as at-motor disconnect" - or 4-pole fusible or non-fusible disconenct for standard OFF-ON or emergency stop in a main panel disconnect application 4th pole available as modular accessory Test mode switch position Disconnecting means - or 4-pole non-fusible disconenct for standard OFF-ON or emergency stop in a main panel disconnect application 4th pole available as modular accessory Test mode switch position Mounting Styles Base/DIN Rail mounting Base/DIN Rail mounting Handles Available in rotary styles, UL Type 1/R/4/4X/12, IP66, standard, or test mode versions Handle colors in black and red/yellow and padlockable versions 0 A/60 A legend markers (optional) uses Cat. No. 1492-MS6X12 markers Available in rotary styles, UL Type 1/R/4/4X/12, IP66, standard, or test mode versions Handle colors in black and red/yellow and padlockable versions Open Switch or Enclosed Open switch Enclosed: UL/CSA rated enclosure Open switch UL/CSA Electrical Ratings: Rated Voltage U e 690V AC 690V AC Rated Current I e 10 A 100 1 A Rated Power P e [FLA] Varies w/ 1- or -phase switch, voltage Varies w/ 1- or -phase switch, voltage Short-Circuit Ratings 0 ka 0 ka Mechanical Life [ops] 10 000 10 000 IEC Rated Current I e AC-1 10 A @ 690V 100 1 A @ 690V AC-21A Varies w/ 1- or -phase switch, voltage Varies w/ 1- or -phase switch, voltage AC-22A Varies w/ 1- or -phase switch, voltage Varies w/ 1- or -phase switch, voltage Ambient Operational Temp. - +60 C (-4 +140 F) - +60 C (-4 +140 F) Ambient Enclosed Temp. - +60 C (-4 +140 F) - +60 C (-4 +140 F) Ambient Storage Temp. -40 +65 C (-40 +149 F) -40 +65 C (-40 +149 F) Protection class per IEC 529 Optional Accessories Standards/Certifications Switch bodies: IP2 Fuse carriers: IP0 Operator handles Multi-length shafts Auxiliary contacts Terminal covers NFPA 79 internal handle with shaft UL 98, UL 508 CSA C22.2, No. 14 IEC 60947- Low Voltage Switchgear and Controlgear part CE Switch bodies: IP2 IP66 handles Multi-length shafts Auxiliary contacts Terminal covers NFPA 79 internal handle CSA C22.2, No. 14 IEC 60947- Low Voltage Switchgear and Controlgear part CE Product Selection Page 4 Page 4 2

Specifications 194R Rotary Disconnect Switches Specifications Fused Disconnect Switches for UL Class Fuses and CSA HRCI-J Electrical Ratings Cat. No. 194R-C0-175 194R-J0-175 194R-J60-175 CSA Fuse Type/UL Fuse Type Class CC/HRCI-MISC Class J/HRCI-J Class J/HRCI-J Maximum Fuse Cartridge Size 0 0 60 Maximum Voltage AC DC [V] [V] Ampere Rating 0 0 60 Maximum Short Circuit Prospective Fault Current [ka] 0 0 0 Fuse Operating Characteristics Maximum Hp, -Phase AC 0V, 60 Hz 240V, 60 Hz 480V, 60 Hz V, 60 Hz Maximum Hp, 1-Phase AC 1V, 60 Hz 240V, 60 Hz Maximum Hp, DC 125V DC V DC Time Delay 5 5 10 10 0.75 2 2 Non-Time Delay 5 7.5 0.5 1.5 5 Time Delay 7.5 7.5 2 5 Non-Time Delay Based on Rockwell Automation tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC 60947- and UL 98. 5 7.5 0.5 1.5 2 5 Time Delay 0 50 10 5 10 Non-Time Delay 7.5 7.5 1.5 5 10 Electrical Ratings Cat. No. 194R-J100-175 194R-J0-175 194R-J400-175 194R-J-175 194R-J800-175 CSA Fuse Type/UL Fuse Type Class J/HRCI-J Class J/HRCI-J Class J/HRCI-J Class J/HRCI-J Class J/HRCI-J Maximum Fuse Cartridge Size 100 0 400 800 Maximum Voltage AC DC [V] [V] Ampere Rating 100 0 400 800 Maximum Short Circuit Prospective Fault Current [ka] 0 0 0 0 0 poles in series 800 Mechanical Data Cat. No. 194R-C0-175, 194R-J0-175 194R-J60-175 Degree of Protection (per IEC 60947-) Switch Only Switch with Terminal Shield & Fuse Carriers Mechanical Endurance Operations 10 000 10 000 Operating Torque (Maximum) Terminal Capacity Power Terminals Auxiliary Contact Terminals N m lb in mm 2 AWG mm 2 AWG.5 5 2.5 10 #14 #8 Maximum Number of Auxiliary Circuits 6 6 Approximate Weight Minimum Enclosure Size Approximate dimensions in millimeters (inches) Switch Dimension Reference (See dimension drawings.) kg lbs Height Width Depth 0.92 2.0 248 (9-/4) 171 (6-/4) 148 (5-1/16) Based on Rockwell Automation tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC 60947- and UL 98. A1.5 5 2.5 25 #14 #4 1.2 2.9 248 (9-/4) 197 (7-/4) 148 (5-1/16) B1 Rockwell Automation Publication 194R-TD001A-EN-P

194R Rotary Disconnect Switches Specifications Degree of Protection (per IEC 60947-) Switch Only Switch with Terminal Shield & Fuse Carriers Mechanical Data Cat. No. 194R-J100-175 194R-J0-175 194R-J400-175 194R-J-175 194R-J800-175 Mechanical Endurance Operations 10 000 8 000 6 000 5 000 5 000 Operating Torque (Maximum) N m lb in Terminal Capacity Power Terminals Auxiliary Contact Terminals mm 2 AWG #1 mm 2 AWG 00 MCM #6 MCM; 2 x 00 MCM #2 or 2 x #6 2 x MCM 2 x #2 Maximum Number of Auxiliary Circuits 4 8 8 8 8 Approximate Weight Minimum Enclosure Size Approximate dimensions in millimeters (inches) Switch Dimension Reference (See dimension drawings.) kg lbs Height Width Depth 2.4 5..6 7.9 4.85 10.7 44 2 x MCM 2 x #2 F5 F6 F7 F8 F8 Based on Rockwell Automation tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC 60947- and UL 98. 44 Non-Fused Disconnect Switches for CSA and UL Class Applications Maximum Voltage Electrical Ratings Cat. No. 194R-N0-175 194R-N60-175 AC DC [V] [V] 194R-NU100-175, 194R-NU100-1754 194R-NU0-175, 194R-NU0-1754 Ampere Rating 0Δ 60Δ 100 0 Maximum Short Circuit Prospective Fault Current [ka] 0 0 0 0 Maximum Hp, - Phase AC Maximum Hp, 1- Phase AC Maximum Hp, DC 0V, 60 Hz 240V, 60 Hz 480V, 60 Hz V, 60 Hz 1V, 60 Hz 240V, 60 Hz 125V DC V DC 7.5 7.5 2 5 5 7.5 0.5 1.5 2 5 0 50 10 5 10 7.5 7.5 1.5 5 10 Power Lost [W] 2 6 Non-fused disconnect switches must be used with separately installed fuses. Maximum Voltage Cat. No. AC DC [V] [V] 194R-NU400-175, 194R-NU400-1754 Electrical Ratings 194R-NU-175, 194R-NU-1754 194R-NU800-175, 194R-NU800-1754 194R-NU10-175, 194R-NU10-1754 Ampere Rating 400 800 10 Fuse Type J J L L Maximum Short Circuit Prospective Fault Current [ka] 0 0 100 100 Non-fused disconnect switches must be used with separately installed fuses. 4 Rockwell Automation Publication 194R-TD001A-EN-P

Specifications 194R Rotary Disconnect Switches Degree of Protection (per IEC 60947-) Switch Only Switch with Terminal Shield & Fuse Carriers Mechanical Data Cat. No. 194R-N0-175 194R-N60-175 194R-NU100-175, 194R-NU100-1754 194R-NU0-175, 194R-NU0-1754 Mechanical Endurance Operations 10 000 10 000 10 000 10 000 Operating Torque (Maximum) Terminal Capacity Power Terminals Auxiliary Contact Terminals N m lb in mm 2 AWG mm 2 AWG.5 5 2.5 10 #14 #8 2.5 10 #14 #8.5 5 2.5 25 #14 #4 2.5 25 #14 #4 10 88.5 00 MCM #6 10 88.5 00 MCM #6 Maximum Number of Auxiliary Circuits 6 6 2 2 Approximate Weight Minimum Enclosure Size Approximate dimensions in millimeters (inches) Switch Dimension Reference (See dimension drawings) kg lbs Height Width Depth 0.81 1.78 248 (9-/4) 171 (6-/4) 111 (4-/8) Non-fused disconnect switches must be used with separately installed fuses. 1.14 2.52 248 (9-/4) 197 (7-/4) 111 (4-/8) 1.67/2.1.7/4. 1.67/2.1.7/4. A2 B2 F1 F1 Mechanical Data Cat. No. 194R-NU400-175, 194R-NU400-1754 194R-NU-175, 194R-NU-1754 194R-NU800-175, 194R-NU800-1754 194R-NU10-175, 194R-NU10-1754 Degree of Protection (per IEC 60947-) Switch Only Switch with Terminal Shield & Fuse Carriers Mechanical Endurance Operations 6 000 6 000 500 500 Operating Torque (Maximum) Terminal Capacity Power Terminals Auxiliary Contact Terminals N m lb in mm 2 AWG mm 2 AWG 14.5 128. MCM #2 7 27.5 2 x MCM 2 x #2 50 442 4 x MCM 4 x #2 50 442 4 x MCM 4 x #2 Maximum Number of Auxiliary Circuits 2 2 2 2 Approximate Weight Minimum Enclosure Size Approximate dimensions in millimeters (inches) Switch Dimension Reference (See dimension drawings) kg lbs Height Width Depth /.8 6.6/8.4 Non-fused disconnect switches must be used with separately installed fuses. 8.2/10. 18.1/22.7 11.6/14.5 25.6/2 11.6/14.5 25.6/2 F2 F F4 F4 Non-Fused Disconnect Switches for IEC Applications Maximum Voltage Electrical Ratings Cat. No. 194R-N0-175 194R-N60-175 AC DC [V] [V] 194R-NE125-175, 194R-NE125-1754 194R-NE160-175, 194R-NE160-1754 Ampere Rating 0 60 125 160 Maximum Short Circuit Prospective Fault Current [ka] 0 0 100 100 Maximum Hp, - Phase AC Maximum Hp, 1- Phase AC Maximum Hp, DC 0V, 60 Hz 240V, 60 Hz 480V, 60 Hz V, 60 Hz 1V, 60 Hz 240V, 60 Hz 125V DC V DC 7.5 7.5 2 5 5 7.5 0.5 1.5 2 5 0 50 10 5 10 7.5 7.5 1.5 5 10 Power Lost [W] 2 6 Non-fused disconnect switches must be used with separately installed fuses. Rockwell Automation Publication 194R-TD001A-EN-P 5

194R Rotary Disconnect Switches Specifications Maximum Voltage Cat. No. AC DC [V] [V] 194R-NE400-175, 194R-NE400-1754 Electrical Ratings 194R-NE60-175, 194R-NE60-1754 194R-NE800-175, 194R-NE800-1754 194R-NE1-175, 194R-NE1-1754 Ampere Rating 400 60 800 1 Maximum Short Circuit Prospective Fault Current [ka] 100 70 50 50 Non-fused disconnect switches must be used with separately installed fuses. All Bulletin 194R Disconnect Switch Cat. Nos., 6 A Range Environmental Data Ambient Temperature Open... C ( F) -2 +55 (-4 +11) Enclosed... C ( F) - +40 (-4 +104) Storage... C ( F) -40 +65 (-40 +149) Altitude (per IEC 60947-1) 2,000 90% @ + C (+68 F) Relative Humidity (per IEC 60947-1) 50% @ +40 C (+104 F) Fused Disconnect Switches For CSA HRCII-C Fuses Electrical Ratings Cat. No. 194R-H0-175 194R-H60-175 CSA Fuse Type HRCII-C HRCII-C Maximum Fuse Cartridge Size 0 60 Maximum Voltage AC [V] Ampere Rating 0 60 Maximum Short Circuit Prospective Fault Current [ka] 0 0 Maximum Hp, -Phase AC Maximum Hp, 1-Phase AC 0V, 60 Hz 240V, 60 Hz 480V, 60 Hz V, 60 Hz 1V, 60 Hz 240V, 60 Hz 7.5 7.5 2 0 50 10 Degree of Protection (per IEC 60947-) Switch Only Switch with Terminal Shield & Fuse Carriers Mechanical Data Cat. No. 194R-H0-175 194R-H60-175 Mechanical Endurance Operations 10 000 10 000 Operating Torque (Maximum) Terminal Capacity Power Terminals Auxiliary Contact Terminals N m lb in mm 2 AWG mm 2 AWG IP IP.5 5 2.5 10 #14 #8 Maximum Number of Auxiliary Circuits 6 6 Approximate Weight Minimum Enclosure Size Approximate dimensions in millimeters (inches) Switch Dimension Reference (See dimension drawings.) kg lbs Height Width Depth 1.18 2.60 248 (9-/4) 171 (6-/4) 148 (5-1/16) Based on Rockwell Automation tests in accordance with the requirements as defined in CSA C22.2 No. 4 and IEC 60947-. B1 IP IP.5 5 2.5 25 #14 #4 1.18 2.60 248 (9-/4) 197 (7-/4) 148 (5-1/16) B1 6 Rockwell Automation Publication 194R-TD001A-EN-P

Specifications 194R Rotary Disconnect Switches Fused Disconnect Switches For BS88 Fuses Fuse classes BS88, DIN, and NFC are not suitable for use in North American applications Cat. No. 194R-B-175 Electrical Ratings 194R-B2-175 194R-B6-175 Fuse Type BS88 Dimension A1 A2 A2, A 194R-B100-175 194R-B160-175 Rated Insulation Voltage (U i ) [V] 1000 1000 1000 750 750 Rated Conditional Short-Circuit [ka] 100 100 100 Current (r.m.s.) at 4V Rated Operational Current AC-22A (I e ) Fuse Links Shorting Links Fuse Links Fuse Links Shorting Links 0/20V 50 Hz 80/400/4V 50 Hz 500V 50 Hz 660/690V 50 Hz Rated Operational Current AC-2A (I e ) 0/20V 50 Hz 80/400/4V 50 Hz 500V 50 Hz 660/690V 50 Hz 22 17 2 2 2 2 2 2 2 2 Rated Thermal Current (l the ) 2 2 6 6 100 160 Maximum kw, AC-2A -Phase 0/20V 50 Hz 80/400/4V 50 Hz 500V 50 Hz 660/690V 50 Hz [kw] [kw] [kw] [kw] 5.5 11 11 9 18.5 18.5 0 Maximum Fuse Rating 2 6 100 160 Maximum Motor Circuit Fuse Link M2 2M6 6M100 Maximum Fuse Cut-off Current [ka] 7.5 7.5 7.5 10 10 Rated Short Time Current, 1 Second [ka] 1 1 1 Fuses must be selected with regard to the maximum prospective fault current of the system and the maximum cut-off current of the fuse when subjected to that maximum fault current. The maximum fuse cut-off current as specified for each disconnect switch must not be exceeded. Electrical Ratings Cat. No. 194R-B0-175 194R-B- 175 194R-B400-175 194R-B60-175 194R-B800-175 194R-B1-175 Fuse Type BS88 Dimension Rated Insulation Voltage (U i ) [V] 750 750 750 750 750 750 Rated Conditional Short-Circuit Current (r.m.s.) at 4V [ka] Rated Operational Current AC-22A (I e ) 0/20V 50 Hz 80/400/4V 50 Hz 500V 50 Hz 660/690V 50 Hz Rated Operational Current AC-2A (I e ) 0/20V 50 Hz 80/400/4V 50 Hz 500V 50 Hz 660/690V 50 Hz 0 0 0 0 Rated Thermal Current (l the ) 0 400 60 800 1 Maximum kw, AC-2A -Phase 0/20V 50 Hz 80/400/4V 50 Hz 500V 50 Hz 660/690V 50 Hz [kw] [kw] [kw] [kw] 80 110 12 2 Maximum Fuse Rating 0 400 60 800 1 Maximum Motor Circuit Fuse Link Maximum Fuse Cut-off Current [ka] Rated Short Time Current, 1 Second [ka] Fuses must be selected with regard to the maximum prospective fault current of the system and the maximum cut-off current of the fuse when subjected to that maximum fault current. The maximum fuse cut-off current as specified for each disconnect switch must not be exceeded. 2 2 2 2 1 5 2.5 2.5 9 18.5 18.5 0 400 400 2 2 6 6 6 6 60.5 57 57 57 18.5 0 0 55 60 500 60 55 295 6 6 6 6 60 57 57 57 18.5 0 0 55 800 800 800 60 450 400 100 100 100 100 51 90 160 160 160 160 6 90 1 800 1000 800 560 400 Rockwell Automation Publication 194R-TD001A-EN-P 7

194R Rotary Disconnect Switches Specifications Mechanical Data Cat. No. 194R-B-175 194R-B2-175 194R-B6-175 194R-B100-175 194R-B160-175 Degree of Protection (per IEC 60947-) Switch Only Switch with Terminal Shield & Fuse Carriers Mechanical Endurance Operations 10 000 10 000 10 000 10 000 10 000 Operating Torque (Maximum) Terminal Capacity Power Terminals Auxiliary Contact Terminals N m lb in mm 2 mm 2 AWG.5 5 2.5 10 #14 #8.5 5 2.5 10 #14 #8.5 5 2.5 25 #14 #4 Maximum Number of Auxiliary Circuits 6 6 6 Approximate Weight Minimum Enclosure Size Approximate dimensions in millimeters (inches) Switch Dimension Reference (See dimension drawings.) kg lbs Height Width Depth 0.8 1.84 248 (9-/4) 171 (6-/4) 148 (5-1/16) 0.8 1.84 248 (9-/4) 171 (6-/4) 148 (5-1/16) 1.18 2.60 248 (9-/4) 197 (7-/4) 148 (5-1/16) 8. 95 1.88 4.75 8. 95 A1 A1 B1 F1 F14 Based on Rockwell Automation tests in accordance with the requirements as defined in IEC 60947-. Mechanical Data Cat. No. 194R-B0-175 194R-B-175 194R-B400-175 194R-B60-175 194R-B800-175 194R-B1-175 Degree of Protection (per IEC 60947- ) Switch Only Switch with Terminal Shield & Fuse Carriers Mechanical Endurance Operations 10 000 10 000 10 000 8 000 5 000 5 000 Operating Torque (Maximum) Terminal Capacity Power Terminals Auxiliary Contact Terminals Maximum Number of Auxiliary Circuits Approximate Weight Minimum Enclosure Size Approximate dimensions in millimeters (inches) Switch Dimension Reference (See dimension drawings.) N m lb in mm 2 240 240 240 240 240 240 mm 2 AWG kg lbs Height Width Depth 40 40 2.7 5.22 40 4 8 8 8 8 8.77 8.7.77 8.7 4.85 10.7 17.77 9 19.77 4.6 7 87.57 F F F16 F17 F17 F18 Based on Rockwell Automation tests in accordance with the requirements as defined in IEC 60947-. Fused Disconnect Switches For DIN Fuses Fuse classes BS88, DIN, and NFC are not suitable for use in North American applications 8 Rockwell Automation Publication 194R-TD001A-EN-P

Specifications 194R Rotary Disconnect Switches Electrical Ratings Cat No. 194R-D2-175 194R-D6-175 194R-D125-175 194R-D160-175 Fuse Type DIN Dimension 00 0, 00 Rated Insulation Voltage (U i ) [V] 1000 1000 750 750 Rated Conditional Short-Circuit Current (r.m.s.) at 4V [ka] 100 100 Rated Operational Current AC-22A (I e ) Fuse Links Fuse Links 0/20V 50 Hz 80/400/4V 50 Hz 500V 50 Hz 660/690V 50 Hz Rated Operational Current AC-2A (I e ) 0/20V 50 Hz 80/400/4V 50 Hz 500V 50 Hz 660/690V 50 Hz 2 2 2 2 1 5 2.5 2.5 Rated Thermal Current (l the ) 40 6 125 160 Maximum kw, AC-2A -Phase 0/20V 50 Hz 80/400/4V 50 Hz 500V 50 Hz 660/690V 50 Hz [kw] [kw] [kw] [kw] 9 18.5 18.5 0 Maximum Fuse Rating 2 6 125 160 Maximum Motor Circuit Fuse Link Maximum Fuse Cut-off Current [ka] 14 Rated Short Time Current, 1 Second [ka] 1 1 Fuses must be selected with regard to the maximum prospective fault current of the system and the maximum cut-off current of the fuse when subjected to that maximum fault current. The maximum fuse cut-off current as specified for each disconnect switch must not be exceeded. Electrical Ratings Cat. No. 194R-D-175 194R-D400-175 194R-D60-175 194R-D800-175 194R-D1-175 Fuse Type BS88 Dimension Rated Insulation Voltage (U i ) [V] 750 750 750 750 750 Rated Conditional Short-Circuit Current (r.m.s.) at 4V [ka] Rated Operational Current AC-22A (I e ) 0/20V 50 Hz 80/400/4V 50 Hz 500V 50 Hz 660/690V 50 Hz Rated Operational Current AC-2A (I e ) 0/20V 50 Hz 80/400/4V 50 Hz 500V 50 Hz 660/690V 50 Hz Rated Thermal Current (l the ) 400 60 800 1 Maximum kw, AC-2A -Phase 0/20V 50 Hz 80/400/4V 50 Hz 500V 50 Hz 660/690V 50 Hz [kw] [kw] [kw] [kw] 12 2 Maximum Fuse Rating 400 60 800 1 Maximum Motor Circuit Fuse Link Maximum Fuse Cut-off Current [ka] Rated Short Time Current, 1 Second [ka] Fuses must be selected with regard to the maximum prospective fault current of the system and the maximum cut-off current of the fuse when subjected to that maximum fault current. The maximum fuse cut-off current as specified for each disconnect switch must not be exceeded. 400 400 2 2 6 6 6 6 60.5 57 57 57 18.5 0 0 55 60 500 60 55 295 800 800 800 60 450 400 160 160 160 160 6 90 1 800 1000 800 560 400 Rockwell Automation Publication 194R-TD001A-EN-P 9

194R Rotary Disconnect Switches Specifications Degree of Protection (per IEC 60947-) Switch Only Switch with Terminal Shield & Fuse Carriers Mechanical Data Cat. No. 194R-D2-175 194R-D6-175 194R-D125-175 194R-D160-175 Mechanical Endurance Operations 10 000 8 000 10 000 10 000 Operating Torque (Maximum) Terminal Capacity Power Terminals Auxiliary Contact Terminals N m lb in mm 2 AWG mm 2 AWG.5 5 2.5 25 #14 #4.5 5 2.5 25 #14 #4 8. 95 2.5 25 #14 #4 Maximum Number of Auxiliary Circuits 6 6 6 6 Approximate Weight Minimum Enclosure Size Approximate dimensions in millimeters (inches) Switch Dimension Reference (See dimension drawings.) kg lbs Height Width Depth 1.18 2.60 248 (9-/4) 197 (7-/4) 148 (5-1/16) 1.18 2.60 248 (9-/4) 197 (7-/4) 148 (5-1/16) Based on Rockwell Automation tests in accordance with the requirements as defined in IEC 60947-. 1.88 4.75 8. 95 2.5 25 #14 #4 2.7 5.22 B1 B1 F1 F1 Mechanical Data Cat. No. 194R-D-175 194R-D400-175 194R-D60-175 194R-D800-175 194R-D1-175 Degree of Protection (per IEC 60947-) Switch Only Switch with Terminal Shield & Fuse Carriers Mechanical Endurance Operations 10 000 10 000 8 000 5 000 5 000 Operating Torque (Maximum) Terminal Capacity Power Terminals Auxiliary Contact Terminals N m lb in 40 mm 2 240 240 240 240 240 mm 2 AWG 40 Maximum Number of Auxiliary Circuits 8 8 8 8 8 Approximate Weight Minimum Enclosure Size Approximate dimensions in millimeters (inches) Switch Dimension Reference (See dimension drawings.) kg lbs Height Width Depth.77 8.7 4.85 10.7 17.77 9 19.77 4.6 40 7 87.57 F F16 F17 F17 F18 Based on Rockwell Automation tests in accordance with the requirements as defined in IEC 60947-. 10 Rockwell Automation Publication 194R-TD001A-EN-P

Specifications 194R Rotary Disconnect Switches Wiring Schematic UL LISTED, CSA CERTIFIED DIMENSION REFERENCE CIRCUIT Cat. No. 194R-C0-175 194R-J0-175 194R-J60-175 194R-H0-175 194R-H60-175 A1 A1 B1 B1 B1 194R-N0-175 194R-N60-175 A2 B2 IEC SWITCHES Cat. No. 194R-B-175 194R-B2-175 194R-B6-175 194R-D2-175 194R-D6-175 194R-F25-175 194R-F2-175 194R-F6-175 194R- * -1754 DIMENSION REFERENCE A1 A1 B1 B1 B1 A1 A1 B1 (See -pole Dimension Reference) for Fused Switches CIRCUIT Rockwell Automation Publication 194R-TD001A-EN-P 11

194R Rotary Disconnect Switches Fuse Description DIN Fuses (100 A shown) Dimensions in millimeters only. Dimensions are not intended to be used for manufacturing purposes. IEC fuse type: Fuse-link with blade contacts Voltage rating: 660/690V AC Interrupting rating: 1,000 A Standard cartridge sizes: 00, 0, 1 and 2 Typical ampere ratings: 2 400 A Construction: Blade type Can be installed on Bulletin 194R disconnect switch Cat. Nos: 194RND072P, ND18P, NDP, ND00P Where used: Europe, South America, Middle East and India Size Max. Rated Current a1 a2 a a4 b (min.) d e1 (max.) e2 (max.) e e4 ±0.2 f 00 100 78.5 ± 1.5 5 45 ± 1.5 49 ±1.5 2 ±0.5 48 0 ±5 6 12.5 0 160 125 ±2.5 67 62 + 1.5 68 +1.5 2 +1.5 0.5 48 40 ±5 6 11.5 1 ±2.5 71 62 ±2.5 68 ±2.5 2.5 +1.5 0.5 5 52 +5 2 6 10 2 400 0 ±2.5 72 62 ±2.5 68 ±2.5 25 2.5 +1.5 0.5 61 60 +5 2 6 10 With Bulletin 194R Fused Disconnect Switches, Continued CSA HRCI and UL Class Fuses (10 A shown) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. UL fuse type: Class CC CSA fuse type: HRCI-MISC Voltage rating: V AC Interrupting rating: 0 000 A Standard cartridge sizes: 0 A Typical ampere ratings: 1 0 A Construction: Ferrule type Can be installed on Bulletin 194R disconnect switch Cat. No: 194R-NC00P Where used: North America CSA HRCI and UL Class Fuses (0 A shown) 27 Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. CSA fuse type: HRCI-J UL fuse type: Class J Voltage rating: V AC Interrupting rating: 0 000 A Standard cartridge sizes: 0, 60, 100, 0, and 400 A Typical ampere ratings: 1 A; Blade type for bolted connection Can be installed on Bulletin 194R disconnect switch Cat. Nos: 194R-NJ00P, NJ060P, NJ100P, NJ0P, NJ400P Where used: North America 12 Rockwell Automation Publication 194R-TD001A-EN-P

Fuse Description 194R Rotary Disconnect Switches CSA HRCII Fuses (100 A shown) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. CSA fuse type: HRCII-C Voltage rating: V AC Interrupting rating: 0 000 A Standard cartridge sizes: 0, 60, 100, 0, and 400 A Typical ampere ratings: 1 400 A Construction: Blade type for bolted connection Can be installed on Bulletin 194R disconnect switch Cat. Nos: 194R-NA0P, NA00P, NH100P, NH0P, NH400P Where used: Canada Standard Cartridge Sizes 0, 60, and 100 A Standard Cartridge Size 0 A Standard Cartridge Size 400 A Current Range A B C D E F G H J 0 0 84.14 (-5/16) 71.04 (2-51/64) 50.8 (2).64 (1/16) 8.7 (11/2) 7.54 (19/64) 5.56 (7/2) 2.81 (/16) 1.59 (1/16) 1 60 88.9 (-1/2) 71.04 (2-51/64) 50.8 (2).64 (1/16) 12.7 (1/2) 7.54 (19/64) 5.56 (7/2) 26.99 (1-1/16) 1.59 (1/16) 61 100 109.54 (4-5/16) 92.47 (-41/64) 60.72 (2-25/64) 4.1 (1-11/2) 19.05 (/4) 11.91 (/2) 8.7 (11/2) 4.9 (1-/8) 2.8 (/2) 101 0 14.94 (5-5/16) 109.14 (4-19/64) 76.2 () 8.1 (1-1/2) 19.05 (/4) 11.91 (/2) 8.7 (11/2).18 (1/8) 1 400 7.96 (8-/16) 1.5 (5-1/4) 76.2 () 60. (2-/8) 25.4 (1) 12.7 (1/2) 9.5 (/8) 25.4 (1) 4.76 (/16) 401 7.96 (8-/16) 1.5 (5-1/4) 76.2 () 76.2 () 25.4 (1).08 (19/2) 10.2 (1/2) 25.4 (1) 9.5 (/8) Rockwell Automation Publication 194R-TD001A-EN-P 1

194R Rotary Disconnect Switches Approximate Dimensions Approximate Dimensions Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Disconnect Switch Dimension References A1, A2, B1, and B2 (0 A and 60 A) D W FD A E H Disconnect Switch Dimension Reference C B Approximate Dimensions mm (in) H W D A B C E FD A1 108 (4-1/4) 1 (4-/4) 101 (4) 90 (-9/16) 105 (4-1/8) 85 (-11/2) 82 (-/64) 2-M4, 2-#8 A2 108 (4-1/4) 1 (4-/4) 80 (-1/8) 90 (-9/16) 105 (4-1/8) 85 (-11/2) 82 (-/64) 2-M4, 2-#8 B1 11 (4-29/64) 142 (5-19/2) 114 (4-1/64) 100 (-/16) 1 (4-2/2) N/A N/A 4-M4, 4-#8 B2 11 (4-29/64) 142 (5-19/2) 9 (-4/64) 100 (-/16) 1 (4-2/2) N/A N/A 4-M4,4-#8 Mounting holes for backward compatibility with Bulletin 194R legacy switches. Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. 14 Rockwell Automation Publication 194R-TD001A-EN-P

Approximate Dimensions 194R Rotary Disconnect Switches UL/CSA Disconnect Switches 100 10 A UL/CSA Non-Fused Disconnect Switches M J1 U Z Y Terminal Shrouds W R1 H N AA AC V K CA R2 T F AD C Cat. No. 194R-N 100 0 Disconnect Switch Dimension Reference F1 400 F2 Approximate Dimensions mm (in) Overall Terminal Shrouds Switch Body Switch Mounting C AC AD 94.6 (.72) 94.6 (.72) 128 (4.92) 256 (10.1) 256 (10.1) 406 (16) 77.5 (.05) 77.5 (.05) 1 (4.) F (- pole) 180 (7.09) 180 (7.09) 20 (9.05) F (4- pole) 20 (9.06) 20 (9.06) 290 (11.4) H 107 (4.22) 107 (4.22) 166 (6.5) J1 (- pole) 55 (2.17) 55 (2.17) 75 (2.95) J1 (4- pole) 105 (4.1) 105 (4.1) (5.1) K 45.6 (1.8) 45.6 (1.8) 67.5 (2.65) M (- pole) 160 (6.) 210 (8.7) 160 (6.) 210 (8.7) 210 (8.26) M (4- pole) N R1 R2 270 (10.6) (5.1) (5.1) 195 (7.67) 9 (0.5) 7 (0.27) 9 (0.5) 7 (0.27) 9 (0.5) 7 (0.27) Cat. No. 194R-N Disconnect Switch Dim. Ref. Approximate Dimensions mm (in) Connection T U V W Y Z AA AC 100 50 (1.97) 25 (0.98) 0 (1.18) 11 (0.4) F1 0 50 (1.97) 25 (0.98) 0 (1.18) 11 (0.4).5 (0.14).5 (0.14) 4.4 (0.14) 4.4 (0.14) 400 F2 65 (2.56) 45 (1.77) 50 (1.97) 1 (0.51) 5 (0.2) 5 (2.08) 160 (6.) (0.6) 160 (6.) (0.6) 260 (10.2) (0.8) Rockwell Automation Publication 194R-TD001A-EN-P

194R Rotary Disconnect Switches Approximate Dimensions Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. H M Z J Ø 0.51 Ø 1 Y X AC N N1 AA. 80 F Cat. No. 194R-N Disconnect Switch Dim.Ref. F Approximate Dimensions mm (in) Terminal Shrouds Switch Body Switch Mounting Connection AC F (-pole) F (4-pole) H J (-pole) J (4-pole) 460 (18.12) 280 (11) 60 (14.17) 140 (5.5) 127.5 (5) 167.5 (6.59) M (- pole) 255 ( 10.0) M (4- pole) N N1 AA Z 5 (1.19) 175(6.88) 59.5 (2.4) (12.6) 47 (1.85) H Z 0.78 1.57 40 Ø 0.4 Ø 11 J M Y X 8.85 225 N2 N1 AC N 0.78 4.72 1 F Cat. No. 194R-N 800 10 Disconnect Switch Dimension Reference F4 Approximate Dimensions mm (in) Terminal Shrouds Switch Body Switch Mounting Connection AC F (-pole) F (4-pole) H 460 (18.12) 460 (18.12) 72 (14.64) 72 (14.64) 492 (19.7) 492 (19.7) 140 (5.5) 140 (5.5) J1 (- pole) 17.5 (6.8) 17.5 (6.8) J1 (4- pole) 2.5 (9.19) 2.5 (9.19) M (- pole) 47 (1.66) 47 (1.66) M (4- pole) N N1 AA Z 467 (18.8) 467 (18.8) 175 (6.88) 175 (6.88) 59.5 (2.4) 59.5 (2.4) 28 (1.10) 47 (1.85) 0 (1) 47 (1.85) 16 Rockwell Automation Publication 194R-TD001A-EN-P

Approximate Dimensions 194R Rotary Disconnect Switches Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. UL/CSA Fused Disconnect Switches 5.87 149. 1.41 6 1.46 7.2 1.41 6 4.81 122.2 7.2 186 6.77 172 5.2 1 Cat. No. 194R-J100 Frame Size F5 7.72 196.2 6.61 168 6.18 7 5.28 14.2 6.50 165.2 7.67 195 11.46 291. 1.41 6 5.11 10 1.96 50 Cat. No. 194R-J0 Frame Size F6 Rockwell Automation Publication 194R-TD001A-EN-P 17

194R Rotary Disconnect Switches Approximate Dimensions Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. 7.08 180 4.7 111.1 10.19 (P) - 12.79 (4P) 259 (P) - 25 (4P) 0.98 24.9 2.95 75 min 10.4 min 265 9.84 6.10 5.12 79.5 0.4 11 fix 11.18 (P) - fix 14.88 (4P) fix 284 (P) - fix 78 (4P) 2.56 1.4 65 4 0.27 7.54 90 0.27 7 11.81 00 10.2 260 fix 9.84 fix 5 126.5 18.54 471.98 101.25 7.97 2.5.6 85.5.5 90 9.44 240.98 101.25 2.95 75.26 8 Cat. No. 194R-J400 Frame Size F7 2.59 66 2.59 66 14.96 80 0.27 7 2.2 59 11.81 00.6 85.5 Cat. No. 194R-J, -J800 Frame Size F8 Ø 0.51 Ø1 2 51.7.7 94 94 14. (P) - 18.0 (4P) 64 (P) - 458 (4P) 0.5 9 18 Rockwell Automation Publication 194R-TD001A-EN-P

Approximate Dimensions 194R Rotary Disconnect Switches Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. IEC Disconnect Switches 125 1 A IEC Non-Fused Disconnect Switches AC AA CA BA CA N J1 W M U1 J2 U V R 90 0 G K Z Y Terminal Shrouds BC A 125 (4.92) X1 T I T F T X2 AD H C 18 (0.71) D min. 45 (1.77) Cat. No. 194R-NE 125 160 400 60 Cat. No. 194R-NE 125 160 400 60 C 1 (4.5) 1 (4.5) 125 (4.92) 160 (6.0) 160 (6.0) Overall D (min.) AC AD 125 (4.92) 125 (4.92) (5.1) 165 (6.50) 165 (6.50) Approximate Dimensions mm (in) Terminal Shrouds Switch Body Switch Mounting 25 (9.25) 25 (9.25) 280 (11.02) 401 (.79) 401 (.79) 50 (1.97) 50 (1.97) 60 (2.6) 89 (.50) 89 (.50) F (- pole) 140 (5.51) 140 (5.51) 180 (7.09) 20 (9.05) 20 (9.05) T U U1 V W 6 (1.41) 6 (1.41) 50 (1.97) 65 (2.56) 65 (2.56) (0.79) (0.79) 25 (0.98) 2 (1.26) 2 (1.26).5 (0.81).5 (0.81) 25.5 (1.00) 45.5 (1.79) 45.5 (1.79) 25 (0.98) 25 (0.98) 0 (1.18) 7.5 (1.48) 7.5 (1.48) 9 (0.5) 9 (0.5) 11 (0.4) 11 (0.4) 11 (0.4) F (4- pole) G H 170 (6.69) 170 (6.69) 20 (9.06) 290 (11.40) 290 (11.40) 9 (.66) 9 (.66) 108 (4.25) 170 (6.69) 170 (6.69) 65 (2.56) 65 (2.56) 75 (2.95) 110 (4.) 110 (4.) Approximate Dimensions mm (in) X1 (- pole) 28 (1.10) 28 (1.10) (1.0) 42.5 (1.67) 42.5 (1.67) Connection J1 (- pole) 45 (1.77) 45 (1.77) 55 (2.17) 75 (2.95) 75 (2.95) J1 (4- pole) J2 K BC 75 (2.95) 75 (2.95) 105 (4.1) (5.1) (5.1) 75 (2.95) 75 (2.95) 105 (4.1) (5.1) (5.1) 1.5 (1.24) 1.5 (1.24) 4 (1.4) 55 (2.17) 55 (2.17) 80 (.) 80 (.) 1 (4.5) 1 (4.5) 1 (4.5) X1 (4- pole) X2 Y Z AA BA AC 22 (87) 22 (87) (1.0) 7.5 (1.48) 7.5 (1.48) (0.79) (0.79) 27 (1.06) 7.5 (1.48) 7.5 (1.48).5 (0.14).5 (0.14).5 (0.14) 5 (0.) 5 (0.).5 (0.81).5 (0.81) 22.5 (0.89) 6 (1.41) 6 (1.41) (5.1) (5.1) 160 (6.0) 25 (9.25) 25 (9.25) 1 (4.5) 1 (4.5) 10 (5.12) 5 (8.07) 5 (8.07) 10 (0.9) 10 (0.9) (0.60) (0.60) (0.79) M (- pole) 1 (4.72) 1 (4.72) 160 (6.0) 210 (8.28) 210 (8.28) M (4- pole) N R 0 (5.90) 0 (5.90) 80 (.) 270 (10.60) 270 (10.60) 65 (2.56) 65 (2.56) 210 (8.27) 140 (5.51) 140 (5.51) 5.5 (0.21) 5.5 (0.21) 5.5 (0.21) 7 (0.28) 7 (0.28) Rockwell Automation Publication 194R-TD001A-EN-P 19

194R Rotary Disconnect Switches Approximate Dimensions Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Cat. No. 194R-N 470 (18.50) AA = 175 (6.89) = X1 U M = = V T I T F 90 T X2 28 (1.10) 0 ø9 (0.5) Z Y 0 (12.99) = = 86 (.9) 26 140 (5.51) (1.02) 49 (1.9) 166 (6.54) Approximate Dimensions mm (in) Terminal Screens 2 (8.46) 14 (0.55) Switch Body Switch Mounting Connection F (-pole) F (4-pole) M (-pole) M (4-pole) T U V Y X1 X2 Z AA 800 280 (11.02) 60 (14.17) 255 (10.04) 5 (1.19) 80 (.) 50 (1.97) 60.5 (2.8) 7 (0.27) 47.5 (1.87) 47.5 (1.87) 46.5 (1.8) 21 (12.64) 1 72 (14.65) 492 (19.7) 47 (1.66) 467 (18.9 1 (4.72) 90 (.54) 44 (1.7) 8 (0.1) 5.5 (2.11) 5.5 (2.11) 47.5 (1.87) 288 (11.4) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Rockwell Automation Publication 194R-TD001A-EN-P

Approximate Dimensions 194R Rotary Disconnect Switches IEC Fused Disconnect Switches fix 5.5 29 (0.22) (1.14) 4.8 (0.19) 14.5 (0.57) min 50 (1.97) max 20 (9.06) 1 4 pre-break auxiliary contacts for signalling Terminal shrouds 179 (7.05) for BS88 / NFC and DIN 100 125 A 189 (7.44) for NFC and DIN 125 160 A 68 (2.68) 41 (1.61) (0.79) 6 (1.42) (1.42) 6 148 (5.8)(P) 184 (7.24)(4P) Ø8.7 (0.4) 8 (0.4) min 19 (5.47) max 145 (5.71) 12 (5.) 1(1.22) 141 (5.55) 2.5 (0.10) 62 (2.44) 2.5 (0.10) 141 (5.55) fix 127 (5.0) 126.5 (4.98) fix 52.5* (2.07) Ø8.5 (0.) 40 fix 6 (1.57) (1.42) (2.1) 54 5.4 (0.21) 5 (1.8) 18 (0.71) 5 (2.09) 162 (6.8) 5 (2.09) 2.5 (0.10) 19.5 (0.77) (0.79) 6 (1.42) (1.42) 6 Cat. No. 194R-B100-175, 194R-D125-175 Frame Size F1 Rockwell Automation Publication 194R-TD001A-EN-P 21

194R Rotary Disconnect Switches Approximate Dimensions Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. fix 5.5 (0.22)(1.14) 29 4.8 (0.19) 14.5 (0.57) min 50 (1.97) max 20 (9.06) 1 4 pre-break auxiliary contact for signalling Terminal shrouds 68 (2.68) (0.79) 50 (1.97) 50 (1.97) 190 (7.48) (P) 240 (9.45) (4P) 8 Ø8.7 (0.1) (0.4) 41 (1.61) min 145 (5.71) max 225 (8.86) 16.5 (5.7) 1 (1.22) 54 (2.1) 5.4 (0.21) fix 50 (1.97) 68 (2.68) 5 (1.8) 18 (0.71) 174 (6.85) 2.5 (0.10) 62 (2.44) 2.5 (0.10) 141 (5.55) fix 140 (5.5) 126.5 (4.98) fix 52.5* (2.07) Ø8.5 (0.) 5 (2.09) 162 (6.8) 5 (2.09) 229 (9.02) 2.5 (0.10) 19.5 (0.77) (0.79) 50 (1.97) 50 (1.97) Cat. No. 194R-B160-175, 194R-D160-175 Frame Size F14 22 Rockwell Automation Publication 194R-TD001A-EN-P

Approximate Dimensions 194R Rotary Disconnect Switches Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. fix 5.5 (0.22) 29 (1.14) 4.8 (0.19) 14.5 (0.57) min 50 (1.97) max 20 (9.06) 1 8 pre-break auxiliary contact for signalling Terminal shrouds 68 (2.6) 52 (2.05) min 4 (6.06) max 225 (8.86) 146 (5.75) 2 (1.26) 64 (2.52) 6.4 (0.25) 60 (1.26) fix 60 (2.6) 60 (1.26) 24 (9.21) (P) 294 (11.57) (4P) Ø11 (0.4) 17 (0.67) 25 (0.98) P 86 (.9) 5 4P 146 (5.75) (1.8) 1 (1.22) 75 (2.95) 185 (7.28) 84 (.) 2.5 (0.10) 2.5 (0.10) 166 (6.54) fix 162 (6.8) 126.5 (4.98) fix 52.5 (2.07) Ø11 (0.4) 195 (7.68) 75 (2.95) 251 (9.88) 2.5 (0.10) 19.5 (0.77) 2 (1.26) 60 (1.26) Cat. No. 194R-B0-175, 194R-D-175 Frame Size F 60 (1.26) Rockwell Automation Publication 194R-TD001A-EN-P 2

194R Rotary Disconnect Switches Approximate Dimensions Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. fix 5.5 (0.22) 29 (1.14) 4.8 (0.19) 14.5 (0.57) min 50 (1.97) max 20 (9.06) 1 8 pre-break auxiliary contact for signalling Terminal shrouds 54 (2.1) 50 (1.97) 66 (2.60) 66 (2.60) Ø11 (0.4) 14.5 (0.57) 252 (9.92) (P) 18 (12.52) (4P) min 7 (6.18) max 225 (8.86) 149 (5.87) 1 (1.22) 70 (2.76) 6.4 (0.25) fix 66 (2.60) 91 (.58) 25 (0.9) 5 (1.8) 84 (.1) fix 172 (6.77) 126.5 (4.9) fix 52.5 (2.07) 175 (6.89) 5 (8.07) (0.12) 75 (2.95) 68 (2.6) 260 (10.24) (0.12) (0.79) 0 (7.87) (0.12) Ø11 (0.4) 50 (1.97) 66 (2.60) 66 (2.60) 75 (2.95) Cat. No. 194R-B400-175, 194R-D400-175 Frame Size F16 24 Rockwell Automation Publication 194R-TD001A-EN-P

Approximate Dimensions 194R Rotary Disconnect Switches Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. 14.5 (0.57) 10.5 (0.41) 11.5 (0.45) 85.5 (.7) Direct operation 1 8 pre-break auxiliary contact for signalling Terminal shrouds min 265 (10.4) (9.84) 5 (6.10) 68 (2.68) 51 (2.01) 94 94 (.70) (.70) (0.79) 64 (14.) (P) 458 (18.0) (4P) Fix 284 (11.18) (P) Fix 78 (14.88) (4P) 65 (2.56) 4 (1.4) 46 (1.81) min (0.59) min 265 (10.4) 79.5 (.1) 85.5 (.7) 11(0.4) 80 (14.96) 7 (0.28) 59 (2.2) 7 (0.28) 00 (1.82) 7 (0.28) 90 (.54) 00 (1.82) 260 (10.24) 85.5 (.7) fix (9.4) Ø1 (0.51) 51 (2.01) 94 (.70) 94 (.70) Cat. No. 194R-B60-175, 194R-D60-175, 194R-B800-175, 194R-D800-175 Frame Size F17 9 (0.5) 22 (0.87) 25.5 (9.27) 25.5 (9.27) Rockwell Automation Publication 194R-TD001A-EN-P 25

194R Rotary Disconnect Switches Approximate Dimensions Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. 14.5 0.57) Direct operation 10.5 (0.41) 1 8 pre-break auxiliary contact for signalling 11.5 (0.45) 85.5 (.7) Terminal shrouds 68 (2.68) min 04 (11.97) 1 (4.72) 1 (4.72) 442 (17.40) (P) 562 (22.1) (4P) 46 (1.81) min (0.59) min 04 (11.97) 289 (11.8) 160 (6.0) fix 62 (14.25) (P) fix 482 (18.98) (4P) 88 (.47) 79.5 (.1) 87.5 (.44) 11 (0.4) 4 (1.4) 7 (0.28) 59 (2.2) 55 (1.98) 7 (0.28) 90 7 (0.28) 00 (11.82) 260 (10.24) fix (9.84) 87.5 (.44) 1 (4.72) 1 (4.72) 22 (0.87) 27.5 (9.5) 27.5 (9.5) 295 (11.61) Cat. No. 194R-B1-175, 194R-D1-175 Frame Size F18 26 Rockwell Automation Publication 194R-TD001A-EN-P

Approximate Dimensions 194R Rotary Disconnect Switches Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Operating Handles Cat. Nos. 194R-P /140U-P 1.2 4.8 mm (0.05 0.19) 80 (.) 114 (4.49) 72. (2.85) 26.7 (1.05) 25.4 (1) Front of Cover ø 5 (ø 1.8) 76.7 (.02) Front 4 (1.4) 50 (1.97) 25 (0.98) 25 (0.98) 50 (1.97) 51 (2.01) Right Side OR 25 (0.98) ø 5 (ø 1.8) 1.5 (1.24) 6 (2.48) (2) - ø 5.5 (0.22) (2) - ø 5.5 (0.22) Rockwell Automation Publication 194R-TD001A-EN-P 27

194R Rotary Disconnect Switches Approximate Dimensions Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Operating Handles Cat. No. 194R-HM4, -HM4E dia. dia. Operating Handles Cat. No. 194R-HM4-L, -HM4E-L, -HM4-N2-L, -HM4E-N2-L Ø 78 (.07) 90 I 4 Ø 7 (0.27) Ø 7 (1.46) 0 (0.78) 210 (8.27) 14 (0.55) 14 (0.55) (0.78) 61 (2.40) 28 Rockwell Automation Publication 194R-TD001A-EN-P

Approximate Dimensions 194R Rotary Disconnect Switches Disconnect Switch Dim. Ref.: A1, A2, B1, B2 (0 A and 60 A) Enclosure and Operating Handle Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Enclosure Installation Dimensions Cat. No. 194R-B-175 194R-B2-175 194R-C0-175 194R-F2-175 194R-J0-175 Dimension Reference A B C D E F Minimum Minimum Minimum Maximum Minimum Minimum Minimum Maximum A1 171 (6-/4) 45 (1-49/64) 147.6 (5-1/16) 454 (17-7/8) 248 (9-/4) 89 (-1/2) 1.4 (1/16) 4/78 (/16) 194R-N0-175 A2 171 (6-/4) 45 (1-49/64) 111 (4-/8) 454 (17-7/8) 248 (9-/4) 89 (-1/2) 1.4 (1/16) 4/78 (/16) 194R-B6-175 194R-D2-175 194R-D6-175 194R-F6-175 194R-H0-175 194R-H60-175 194R-J60-175 B1 197 (7-/4) 45 (1-49/64) 147.6 (5-1/16) 454 (17-7/8) 248 (9-/4) 105 (4-9/64) 1.4 (1/16) 4/78 (/16) 194R-N60-175 B2 197 (7-/4) 45 (1-49/64) 111 (4-/8) 454 (17-7/8) 248 (9-/4) 105 (4-9/64) 1.4 (1/16) 4/78 (/16) Rockwell Automation Publication 194R-TD001A-EN-P 29

194R Rotary Disconnect Switches Approximate Dimensions NFPA 79 Internal Handle with Shaft Dimensions Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. L X Y Z Catalog No. 194R -NHR1 194R -NHR2 mm (in.) mm (in.) L X Y Z (max) 05 (12) 5 (21) 8 (1-1/2) 8 (1-1/2) 76 () 76 () 57 (2-1/4) 57 (2-1/4) Y D1 W W1 X Y H 194R-B-* 194R-B2-* 194R-C0-* Catalog No. 194R-F25-* 194R-F2-* 194R-J0-* Dim. Ref. A1 mm (in.) H 108 (4-1/4) W 1 (4-/4) W1 19 (/4) D1 (min) 184 (7-1/4) X 8 (1-1/2) Y 76 () 194R-N0-* A2 mm (in.) 108 (4-1/4) 1 (4-/4) 19 (/4) 160 (6-5/16) 8 (1-1/2) 76 () 194R-B6-* 194R-D2-* 194R-D6-* 194R-F6-* 194R-H0-* 194R-H60-* 194R-J60-* B1 mm (in.) 11 (4-29/64) 142 (5-19/2) 19 (/4) 196 (7-49/64) 8 (1-1/2) 76 () 194R-N60-* B2 mm (in.) 11 (4-29/64) 142 (5-19/2) 19 (/4) 176 (6-59/64) 8 (1-1/2) 76 () 0 Rockwell Automation Publication 194R-TD001A-EN-P

Approximate Dimensions 194R Rotary Disconnect Switches Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. IP66 (Type /4/12) Watertight, Dusttight Sheet Metal Enclosure A G D C 7.1 (9/2) 76.0 (.0) E F H B 6.0 (/64) Four Mounting Holes Ø 5.5 (.218) External Mounting Feet Optional Cat. No. 198-F1 Type Dim. Ref. A B C D E F G H 0 60 Non-Fused & Fused Non-Fused & Fused A1 & A2 0 (7-7/8) B1 & B2 0 (7-7/8) 00 (11-1/16) 00 (11-1/16) 160 (6-19/64) 0 (7-7/8) 160 (6-19/64) 0 (7-7/8) 25 (12-51/64) 25 (12-51/64) 1 (12-21/64) 1 (12-21/64) 105 (4-1/8) 26 (9-9/2) 105 (4-1/8) 26 (9-9/2) Type 4/4X Watertight, Corrosion-Resistant Stainless Steel Enclosure A1 A G D C B E F External Mounting Feet Optional Cat. No. 198-F Type Dim. Ref. A A1 B C D E F G H 0 Non-Fused A2 9 (6-1/4) 170 (6-11/16) Fused A1 214 (8-7/16) 225 (8-7/8) 60 Non-Fused & Fused B1 & B2 214 (8-7/16) 225 (8-7/8) 240 (9-7/16) 265 (10-7/16) 265 (10-7/16) 12 (4-27/2) 16 (6-7/16) 254 (10 ) 27 (10-/4 8 (-1/4) 160 (6-5/16) 0 (7-7/8) 279 (11) 160 (6-5/16) 0 (7-7/8) 279 (11) 298 (11-2/2) 298 (11-2/2) 8 (-1/4) 8 (-1/4) Rockwell Automation Publication 194R-TD001A-EN-P 1

194R Rotary Disconnect Switches Approximate Dimensions Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. IP66 (Type /4/4X/12) Corrosion-Resistant, Non-Metallic Enclosure K A 6.0 (/64) H D C F B J 2.0 (1-1/4) G Four Slot Mounting Holes 8 x 1 (0.1 x 0.50) Cat. No. 194R-K_0P, -K60P 0 and 60 A switch K 5.0 (/16) A H D C F B J 2.0 (1-1/4) G Four Slot Mounting Holes 8 x 1 (0.1 x 0.50) Cat. No. 194R-K_100P 100 A switch Switch Size A B C D F G J K 0/60 226 (8-59/64) 267 (10-1/2) 16 (6-27/64) 2 (7-61/64) 278 (10-61/64) 2 (6) 05 (12) 6 (/64) 2 Rockwell Automation Publication 194R-TD001A-EN-P

Approximate Dimensions 194R Rotary Disconnect Switches Dimensions are in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. 2.4 (6) 12.8 (4-7/8) mm (in.) 100 ( - /16).2 (8) Ref..4 (10) Min. 194R-FC Cable-Operated Handle Rockwell Automation Publication 194R-TD001A-EN-P

194R Rotary Disconnect Switches Specifications 4 Rockwell Automation Publication 194R-TD001A-EN-P

Specifications 194R Rotary Disconnect Switches Rockwell Automation Publication 194R-TD001A-EN-P 5

194R Rotary Disconnect Switches Specifications 6 Rockwell Automation Publication 194R-TD001A-EN-P

Specifications 194R Rotary Disconnect Switches Rockwell Automation Publication 194R-TD001A-EN-P 7

194R Rotary Disconnect Switches Specifications 8 Rockwell Automation Publication 194R-TD001A-EN-P

Specifications 194R Rotary Disconnect Switches Rockwell Automation Publication 194R-TD001A-EN-P 9

194R Rotary Disconnect Switches Specifications 40 Rockwell Automation Publication 194R-TD001A-EN-P

Specifications 194R Rotary Disconnect Switches Rockwell Automation Publication 194R-TD001A-EN-P 41

Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice. If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/. Allen-Bradley, Rockwell Software, Rockwell Automation, and LISTEN. THINK. SOLVE are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 4752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 Publication 194R-TD001A-EN-P - August 14 Copyright 14 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.