An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware



Similar documents
This paper will explain some of the more important factors on how UTP wires work; specifically it will cover the following:

with Component Rating A Simple Perspective

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

Measurement setup for differential-mode and common-mode channels

Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel

AMP CO Plus Insert for Cat. 6 A Applications

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

How to Choose the Right Cable Category

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

Nexus Technology Review -- Exhibit A

Understanding the Electrical Performance of Category Cables

Data Communications Competence Center

The Next Generation of Cable Technology. A technology primer from NORDX/CDT By, Eric d Allmen

GigaSPEED X10D Solution How

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

Enhanced Category 5 Cabling System Engineering for Performance

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks

The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges

The effect of temperature on the bandwidth of telecommunications cabling in commercial buildings. Focus on the IBDN System 4800LX from NORDX/CDT

Testing 10 Gb/s Performance of Category 6 and 6A Structured Copper Cabling Systems within the Unified Physical Infrastructure SM (UPI)

White Paper. Cat. 6A vs. Cat. 6 A. What s the Difference and Why Should I Care?

White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems

Gigabit Ethernet on Copper Cabling Infrastructures

Common Mode Choke Filtering Improves CMRR in Ethernet Transformer Applications. Application Note. June 2011

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

White Paper: DC Resistance Unbalance Testing: Easy, Low-Cost Insurance for Your PoE Systems

Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet

How To Counter Noise Noise From A Low Voltage Differential Signaling Circuit

G019.A (4/99) UNDERSTANDING COMMON MODE NOISE

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka

Computer buses and interfaces

Design Guidelines for PoE Based Security Systems. Carlos Carle, P.E. SignaMax Systems, Inc.

10 Gigabit Ethernet over copper: Unshielded, unprotected?

Ethernet Patch Cord Wiring

PANDUIT TX6 10GIG SHIELDED COPPER CABLING SYSTEM. Innovative Connectivity Solution for Maximum Performance and Security

Category 8 Cable Transmission Measurements Comparative Study between 4-port single wire measurements and 2-port balun measurements

Innovative Connectivity Solution for Maximum Performance and Security

The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT

ATT-TP Ethernet Copper Cable & Ethernet Copper Assembly Specification

On Cables and Connections A discussion by Dr. J. Kramer

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8

Chapter 4 Connecting to the Internet through an ISP

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

Application Note: How to Connect a Wired Ethernet Port to the WiPort

Power over Ethernet technology for industrial Ethernet networks

Discussion Paper Category 6 vs Category 5e Cabling Systems and Implications for Voice over IP Networks

RS485 & RS422 Basics

Cabling for 10GBASE-T and Beyond - A Tangled Web

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

KVPX CONNECTOR SERIES HIGH SPEED SIGNAL INTEGRITY REPORT

EMC Basics. Speaker : Alain Lafuente. Alain.lafuente@we-online.com

Network Design. Yiannos Mylonas

Copper Patch Cords. Impact On Network Performance and Reliability

2 Network Media. Copper Core Cable

Broadband Video over Twisted Pair Cabling. By Paul Kish Director, IBDN Systems & Standards NORDX/CDT

Physical Infrastructure trends and certification requirements for Datacenters. Psiber s Global Village

Introduction to Digital Subscriber s Line (DSL)

Category 8 Cabling Standards Update

Network Engineers Everywhere:

Safety & Performance in the Wire and Cable Industry

IT Cabling Solutions

How To Get A Better Signal From A Fiber To A Coax Cable

LVDS Technology Solves Typical EMI Problems Associated with Cell Phone Cameras and Displays

INTERNATIONAL STANDARD

Application Note: How to Connect a Lantronix Embedded Module to a Wired Ethernet Port

Network Monitoring White Paper

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

Total Solutions Verification

WHITEPAPER. Cable and Connector for Hiperface dsl motor drive applications

Power over Ethernet with Panduit Copper Cabling

PRODUCT SPECIFICATION

PCS0100en Persy Control Services B.V. Netherlands

This application note is written for a reader that is familiar with Ethernet hardware design.

How To Get 40G Over Copper (Wired) And 40G On Coaxian (Wireless) Cable (Wired Coaxian) (Wired Cable) (Wireline) (Powerline) And 50G Over Coaxian Cable (Wire Coaxian

Model CFA-24 Transparent Cable Farm Automation Switch

White Paper. Crestron 8G DigitalMedia Cable

De-Mystifying Cabling Specifications

Abstract: This document examines the alien NEXT performance of various bundled cables and measures the impact upon various networks performance.

INTERNATIONAL STANDARD

Managing Connector and Cable Assembly Performance for USB SuperSpeed

An Ethernet Cable Discharge Event (CDE) Test and Measurement System

SYSTIMAX Copper Solutions Designed for the Digital Generation

Networks. The two main network types are: Peer networks

Datasheet: DSX-5000 CableAnalyzer

Common Mode and Differential Mode Noise Filtering

SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS

1000BASE-T: Gigabit Ethernet. over Category. 5 copper. cabling. Acronyms and abbreviations

Structured Cabling, Earthing & Equipotential Bonding

Application Note 52. ADSL line qualification tests Author: Peter Ziemann (

A Feasibility Study of One Twisted Pair Gigabit Ethernet

Future Proofing with Category 7 and 7A Cabling for 25 and 40GBASE-T Carries High Levels of Risk

The Do s and Don ts of Pressure Transducers

Selecting Receiving Antennas for Radio Tracking

If you want to get an official version of this User Network Interface Specification, please order it by sending your request to:

With the advent of Gigabit Ethernet

Transcription:

for CAT 6A Connecting Hardware Written by: Antoine Pelletier Engineer, Global Cabling Products Intertek www.intertek-etlsemko.com 1-800-WORLDLAB

Introduction The telecommunication industry recently achieved a huge step forward with the ratification of standards enabling 10 Gigabit per second over 4 twisted pairs of conductors, up to a maximal cabling length of 100m (10GBASE-T protocol). These efforts started within the Institute of Electrical and Electronics Engineers (IEEE) 802.3an Task Force, which established all of the physical layer requirements in order to support 10GBASE-T operation, published under the document IEEE 802.3an TM 2006. During the standards development, the Telecommunication Industry Association (TIA) worked closely with IEEE to establish systems, component requirements, and repeatable test procedures to ensure the end-users cabling installations meet the ANSI/TIA-568-B.2-10 industry specifications. Such system and component requirements allow the installed cabling to reliably support 10GBASE-T operation. Due to the dominance of twisted-pair category cables (5e and better) in the market, the standards have focused on keeping the same user-friendly and well known RJ45 connector interface allowing for backward compatibility. The RJ45 connector was originally adopted as a standard interface in 1991 when the data transmission speeds were limited to 10Mb/s, and an operational frequency up to 16MHz. Today, the 10GBASE-T protocol has an operational frequency up to 500MHz. Using the RJ45 connector at high frequencies leads to big challenges for the industry, such as reducing the amount of parasitic interferences. Any irregularity over the cabling length will adversely affect the signal transmission, unless the connectors are well designed to operate at such high frequencies. In this whitepaper, you will be provided with expert insights into the testing of connecting hardware including: Definition of key parameters to ensure Augmented Category 6 compliance at the component level. Details on the test procedures, with illustrations of the specific test fixtures required for connecting hardware testing. Benefits and guarantees of compliant connecting hardware with examples of improvements. www.intertek-etlsemko.com 2

Augmented Category 6 Connecting Hardware Testing There are nine (9) important parameters that need to be tested in order to ensure full compliance of Augmented Category 6 connecting hardware. 1. Insertion loss (attenuation) Insertion loss limit values ensure that the signal will have sufficient strength at the other end. This parameter is normally met through the design of any connector, because they do not attenuate the signal significantly due to their very short length. Even though the length is short, additional losses at higher frequencies can result from connector impedance mismatch. 2. Near-end crosstalk (NEXT) The NEXT is the ratio of unwanted signal that is radiated on the same end of any of the three (3) other pairs, relative to the amount of signal that is injected on the disturbing pair, as shown in Figure 1. The NEXT test ensures that there will not be too much power interference on the other pairs. Figure 1: NEXT coupling illustration www.intertek-etlsemko.com 3

3. Far-end crosstalk (FEXT) The FEXT is the ratio of unwanted signal that is radiated on the opposite end of any of the three (3) other pairs, relative to the amount of signal that is injected on the disturbing pair, as shown in Figure 2. The FEXT test also ensures that not too much power will be radiated on neighboring pairs. 4. Return loss Figure 2: FEXT coupling illustration The return loss is the ratio of reflected signal, relative to the signal that is injected on the same end of the same pair. The return loss testing is important because 10GBASE-T protocol uses bi-directional transmission on all four (4) pairs. Therefore, any reflection in the transmitted signal would come back in the receiver as an unwanted signal, as shown in the following figure. Figure 3: Return loss signal reflections illustration www.intertek-etlsemko.com 4

5. Transverse conversion loss (TCL) The TCL is the measured ratio of common mode signal (adverse signal), relative to the amount of differential mode signal injected at the same end of the same pair (or vice-versa). The TCL test gives an indication of the connector s electromagnetic immunity. Therefore, the common mode signals which may come from ambient electromagnetic noise, for instance, have a risk of being converted to differential mode and being added to the intelligible signal. On the other hand, a differential mode signal may be partially converted to common mode and some equipment is more sensitive to common mode signal. Figure 4: Mode conversion illustration 6. Transverse conversion transfer loss (TCTL) The TCTL is similar to the TCL, with the difference that the parasitic common mode voltage is measured at the opposite end than the injected differential mode signal. The TCTL, as well, is an indication of the connector s electromagnetic immunity. 7. DC resistance unbalance The DC resistance unbalance is the resistance difference between two conductors of the same pair. Any difference in DC resistance may have adverse effects on the Network Interface Cards (NICs) or active equipments when using Power over Ethernet (PoE) technology. www.intertek-etlsemko.com 5

8. Power sum alien near-end crosstalk (PSANEXT) The PSANEXT is the summation of all radiated power from neighboring connectors, measured at the same end as the injected power. The PSANEXT is a new parameter that became important because 10GBASE-T operates at much higher frequencies radiating power farther to distant connectors. 9. Power sum alien far-end crosstalk (PSAFEXT) The PSAFEXT is the summation of all radiated power from neighboring connectors, measured at the opposite end than injected power. The PSAFEXT is a new important parameter that has been standardized since the Augmented Category 6 standard. These are parameters that need to be tested for every component and system. For connecting hardware, there are many additional challenges in the test fixtures and test methods because it is not feasible to interface the RJ45 connecting hardware directly between the front of the connector and the network analyzers. The TIA created a task group uniting the industry s connecting hardware experts with the mandate to achieve reliable and repeatable connecting hardware test procedures. When testing connecting hardware, the starting point always includes a suitable test plug with known characteristics that represent the plugs that are meant to be mated with the connecting hardware. Therefore, a method of qualifying the test plug was established and proper fixtures were designed. The following two figures show an example of both a proposed test plug and a specially designed test fixture that enables the test plug qualification. Figure 5: Controlled test plug illustration www.intertek-etlsemko.com 6

The test plug shown in Figure 5, illustrates a test plug that has, by design, tightly controlled return loss and crosstalk characteristics. The printed circuit board plug enables control of the plug s characteristics. However, plugs with twisted wire pairs may also be used to test connecting hardware if they meet the test plug standard requirements. Figure 6: Measurement fixture for test plug qualification The test fixture shown in Figure 6 has been specially designed to measure the intrinsic characteristics of the plug. This test fixture has good return loss characteristics and no significant crosstalk, thereby enabling direct measurement of the test plugs. The ANSI/TIA-568-B.2-10 standard defines very detailed test methods to determine the characteristics of the connecting hardware using the measured test plug data. Those new methods involve an extensive set of calculations that can determine the precise performance of the connecting hardware. Benefits and guarantees of a compliant connecting hardware The connecting hardware has to face various challenges in order to support data transmission to the desired speeds. For the most part, they come from the legacy of the RJ45 plug, which intrinsically has a significant amount of crosstalk coupling (NEXT and FEXT). This crosstalk is mainly due to the proximity of the wire pairs that are crimped with a blade contact, having a big enough area to behave like a transmitting and receiving antenna. This issue is worse for all combinations involving the wire pair positioned in contacts number 3 and 6, because it is split and adjacent to all three (3) other pairs, as shown in the following picture. www.intertek-etlsemko.com 7

Figure 7: Illustration of RJ45 plug scheme and intrinsic crosstalk The connecting hardware has to compensate for the plug s coupling by adding a coupling of the opposite polarity in order to cancel out most of the plug s offending crosstalk. The following figure (not to scale) illustrates the plug s intrinsic coupling, the jack s compensation and the resultant reduced crosstalk. Figure 8: Connecting hardware NEXT interferences reduction principle A low NEXT coupling is a key to guaranteeing a good data transmission because the connectors are normally positioned at the extremities of the cabling channels. Any NEXT coupling will create additional parasitic noise over the signal on the neighboring pairs, which can be seen by the equipment. The following figure illustrates the minimal NEXT interferences reduction of wire pair combinations involving wire pair 3, 6 at the frequency of 100MHz. www.intertek-etlsemko.com 8

Category 6A mated connection NEXT improvements at 100MHz 14 12 NEXT interferences (mv/v) 10 8 6 4 78% to 81% minimal improvement 82% to 83% minimal improvement 40% to 58% minimal improvement 2 0 3,6-4,5 Plug's NEXT for side cases Mated connection NEXT 3,6-4,5 Plug's NEXT for center cases Mated connection NEXT 1,2-3,6 & 3,6-7,8 Plug's NEXT Mated connection NEXT Figure 9: Connecting hardware minimal NEXT interferences reduction Another improvement of Category 6A connecting hardware is on return loss limit lines. Compared to Category 6 connecting hardware, the limit line is 4dB higher, which means that 60% less power will be reflected back into the transmitter. Ultimately, the compliance to all test parameters will guarantee a proper data transmission in order to transmit protocols up to 10GBASE-T. www.intertek-etlsemko.com 9

Conclusion Intertek is the leading provider of performance and safety testing in the cabling industry. We continue to move forward in our Category 6A testing capabilities with the recent creation of a state-of-the-art connecting hardware test setup. Because of the recent ratification of the Category 6A standard by TIA, Intertek is now able to offer manufacturers the latest in testing for Category 6 and 6A connecting hardware transmission parameters testing. This will allow us to continue providing our customers with the flexibility and fast turnaround times they have come to expect from Intertek. Additional Information For more information on Intertek s CAT 6A testing capabilities, please contact Intertek at 1-800-WORLDLAB, email icenter@intertek.com, or visit our website at www.intertek-etlsemko.com. www.intertek-etlsemko.com 10