R&Mfreenet Advanced Cat 6 A Unshielded Connection Module



Similar documents
01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

HARTING Ethernet Cabling 8-poles Overview

Ethernet Cat 5e & Cat 6 Patch Panels

Accelerating Light. Copper Cabling Solutions. Category 6A

Panduit 28 AWG Patch Cords Installation Guideline

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

HARTING Ethernet Cabling 4-poles Overview

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Cat. 6 A EL Incredibly fast Get more

An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware

SMARTen 24 UTP Patch Panels

Simpler all over. Simpler all round. 500 MHz. 10 GB ether. fully shielded. Poe+ Cat.6 A. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

HARTING Ethernet Cabling 4-poles Overview

AMP CO Plus Insert for Cat. 6 A Applications

SMARTen 24 STP Patch Panels

Copper Patch Cords. Impact On Network Performance and Reliability

White Paper. Cat. 6A vs. Cat. 6 A. What s the Difference and Why Should I Care?

SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS

Simpler all over. Simpler all round. fully Ether. PoE+ shielded. MHz. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug

Standard Buccaneer - Ethernet

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Category 6 UTP - Cabling System

INTELLIGENT INFRASTRUCTURE MANAGEMENT

Specification SFTP CAT6 Network Cable 23AWG CU

C6 A modul and C6 A modul K. The new connection system for all applications of course with Cat.6 A

Method for improving Return Loss in order to reduce PHY power Ron Nordin Panduit Bob Wagner Panduit Paul Vanderlaan Berk-Tek

6000 Series Buccaneer

Network Design. Yiannos Mylonas

IEC Connectors. Introduction

White Paper: What Component Compliance Means for CAT6A System Performance

Keystone Network Isolator with ESD- and Lightning Protection

White Paper. Power over Ethernet Plus Update and Cabling Considerations

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

IT Cabling Solutions

Universal MATE-N-LOK Connectors

08. SEK IDC CONNECTORS

IFS SP-PoE Splitter User Manual

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

Model CFA-24 Transparent Cable Farm Automation Switch

Cabling for 10GBASE-T and Beyond - A Tangled Web

Innovative Connectivity Solution for Maximum Performance and Security

White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems

MapIT G2 Infrastructure Management

.093 [2.36] Commercial Pin and Socket Connectors

E Series. E Series. Category 6 and 5e. Features

Communication, Signal & Data Cables

CIN::APSE MICROMINIATURE D-SUB

IP 20 B.1 8 IP 65 / IP 67 B Cables B Tools B IP 20 B.2 8 IP 65 / IP 67 B Cables B Tools B IP 20 B.

Cisco Unified IP Phone Power Injector

HP ProCurve High-Speed Transceivers Installation Guide

The High Cost of a Low-Cost Cable Certification Tester

White Paper: DC Resistance Unbalance Testing: Easy, Low-Cost Insurance for Your PoE Systems

SYSTIMAX Solutions. GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions.

Network Engineers Everywhere:

Testing 10 Gb/s Performance of Category 6 and 6A Structured Copper Cabling Systems within the Unified Physical Infrastructure SM (UPI)

Power over Ethernet with Panduit Copper Cabling

with Component Rating A Simple Perspective

NETWORKING GUIDE. designed to be better.

Directory chapter 04

10 Gigabit Ethernet over copper: Unshielded, unprotected?

LIEBERT VNSA Installation Sheet

New Technology Developments and How They Impact Your Structured Wiring Choices

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)

Future Proofing with Category 7 and 7A Cabling for 25 and 40GBASE-T Carries High Levels of Risk

The 10G wiring system

Copper Cables CONNECTIVITY & CABLING SYSTEM

Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems)

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Security & Surveillance Cabling Systems

Copper Closet. Copper Closet

Rutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions.

GEU Port Gigabit Switch

RTEX Cable 2015/10/1. Motor Business Unit Automotive & Industrial Systems Company Panasonic Corporation

Cable Sharing in Commercial Building Environments

Mini USB and USB 2.0-IP67 Connector System

Cabling Standards Update 2014

Quick Connect. quick - simple - efficient.

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

Terminal and Dimension

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Interface RF Connector with Switch

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

PROFINET New Cabling for Gigabit Ethernet End-to-End Link (E2E) Dipl.-Ing. Rainer Schmidt HARTING

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8

Terminal and Dimension

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

COAXICON Contacts. RF Coax Connectors. Product Facts

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits

INTRODUCTION KRONE HIGHBAND. KRONE has a long history as a market leader in the communications and information industry.

Appendix A lists known cable and connector vendors, part numbers and contact information for sourcing.

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Transcription:

R&Mfreenet Advanced

R&Mfreenet Advanced Cat 6 A Connection Module The R&Mfreenet Cat 6 A unshielded connection modules, part of the Advanced cabling system, are ideal for voice, fast data transmissions and high bandwidth applications. This high-performance Cat 6 A module is perfect for use in 10 Gigabit Ethernet (10GBASE-T) and future high-speed applications to 500 MHz. R&Mfreenet Advanced Cat 6 A Features Exceeds the Cat 6 A specification (mated) for the entire re-embedded plug range as specified by IEC 60603-7-41 and IEC 60512-27-100. Exceeds the Cat 6A specification (mated) for the entire re-embedded plug range as specified by TIA/EIA 568-C.2 Attains Cat. 6 A values together with Cat. 6 A patch cables as specified in standard IEC 11801 Ed 2.2, June 2011, and EN50173-1: May 2011. Achieves exceptional margins when installed as part of an R&M Cat 6 A unshielded channel or permanent link, exceeding the IEEE 802.3an minimum requirements for 10GBASE-T performance, as well as the requirements for Class E A performance according to ISO/IEC 11801 ed. 2.2, June 2011, and Cat. 6A performance according to TIA/EIA 568-C.2. Achieves best transmission characteristics with R&Mfreenet Advanced Cat 6 A patch cables Gold-plated contact area and tin-plated insulation displacement contact area Capacitive and inductive compensation Compatible with Cat 6 A standard patch cords and cables Automatic cutting of wires for precise, consistent termination X-Separator isolates pairs from each other, minimizing influence of cable termination on NEXT performance Use of all four sides of modules maximizes distance between pairs for optimum performance Unique cable handling part design maximizes space for routing wires without sacrificing density RJ-11 compatible Fits into all R&Mfreenet patch panels and most outlets, as well as in selected vendors faceplates by using specific adapters Connection of installation cables of AWG 22-26 plus stranded cables of AWG 22/7 26/7 w/o special tools Wiring option according to TIA/EIA 568 A and B without splitting of pair 3,6 Easy to read color wiring chart Integrated production date for quality tracing PoE and PoE+ compatible according to IEC 60512-99-001 GHMT and 3P certified Standards IEC 60603-7-41: Electrical Characteristics of the Telecommunication Outlets ISO/IEC 11801, Ed. 2.2: June 2011 EN50173-1: May 2011

Mechanical Data Number of RJ45 jacks 1 Number of signal contacts 8/jack Operating temperature range -10 C to 60 C Storage temperature range C to 70 C Humidity 95% (non-condensing) Contact material CuSn Contact area plating 1.2 µm gold over nickel IDC* plating Tin-plated Cutting blade material Stainless steel Housing material Polycarbonate (UL-94-V0) Admissible wire Ø 0.4 mm (AWG26) 0.65 mm (AWG22) Admissible strand Ø AWG26/7 AWG22/7 Admissible insulation Ø 0.8 mm 1.6 mm Cable diameter 10 mm maximum Cable strain relief Through cable tie *IDC: Insulation Displacement Contact Description Standard value Relevant Standard Typical value (at 20 C) Mating cycles min. > 750 ISO/IEC 11801 2 nd Ed. > 1000 Re-terminations** > 20 ISO/IEC 11801 2 nd Ed. > 20 **Re-terminations may be performed with wire that is either larger or up to two wire gages smaller than wire originally terminated. Dimensions unshielded

Electrical Data Description Standard value Relevant standard Typical value (at 20 C) Electric strength Contacts 1000 V DC or AC peak IEC 60603-7-41 > 1000 V eff Insulation resistance > 500 MΩ (100 V DC) IEC 60603-7-41 > 5 GΩ (100 V DC) Contact resistance < 20 mω IEC 60603-7-41 < 5 mω I/O resistance < 200 mω IEC 60603-7-41 60 mω I/O resistance unbalance < 50 mω IEC 60603-7-41 30 mω Current carrying capacity 1 Amp @ 60 C IEC 60603-7- 41 Pass Frequency (MHz) Insertion Loss (20 C) Return Loss (20 C) NEXT (20 C) all pair combinations TCL (20 C) PS ANEXT (20 C) 1.0 > -0.05-48.3-97.3-84.4-81.2 4.0 > -0.05-49.2-86.2-73.6-83.2 10.0 > -0.05-46.1.0-66.1-81.1 16.0 > -0.05-44.3-79.7-62.2-79.2 20.0 > -0.05-43.9-73.2.3.8 31.0 > -0.05-42.6-69.5-56.6-81.2 62.0 > -0.05-38.2-63.4.8-84.2 100.0 > -0.05-32.6-59.5-47.3.5 125.0 > -0.05.3-57.7-45.5-78.6 155.0 > -0.05-28.5-55.4-43.5-76.8 175.0 > -0.05-27.2-54.1-42.7-76.1 200.0-0.06-25.7-52.6-42.0-74.7 250.0-0.08-23.6-49.8.1-72.8 300.0-0.12-21.7-47.4-38.5.9 400.0-0.23-19.7-41.6-35.6-69.5 500.0-0.42-17.6-37.3-33.5-66.9

Insertion Loss Insertion Loss 0.00-0.10-0.20-0.30-0.40-0.50-0.60-0.70-0.80 12 36 45 78-0.90-1.00 Return Loss Return Loss 0-5 -10-15 -20-25 -35 12 36 45 78-45

NEXT 36-45 NEXT 36-45 -35, high low -45-55 -65, central high, central low 36-45 high 36-45 central high 36-45 central low 36-45 low -75 NEXT 45-12, 45-78 NEXT 45-12, 45-78 -35-45 -55-65 45-12 low 45-12 high 45-78 low 45-78 high -75

NEXT 36-12, 36-78 NEXT 36-12, 36-78 -35-45 -55-65 36-12 low 36-12 high 36-78 low 36-78 high -75 NEXT 12-78 NEXT 12-78 -35-45 -55-65 12-78 low 12-78 high -75

TCL TCL 0-10 -20 12 36 45 78 PSANEXT PS ANEXT -55 0 100 200 300 400 500-65 PS ANEXT Pair 12 Pair 36 Pair 45 Pair 78-75 Frequency[MHz]

Keystone Cut-out The keystone adapter ensures that the module will fit in keystone cut-outs as defined in IEC60603-7 ed. 3 Annex D. Connector dimensions Letter Maximum Minimum mm mm A 1 16.51 16.00 B 1 22.43 22.07 C 1 12.65 12.34 J 1 1.65 1.17 K 1 9.78 9.53 L 1 1.75 1.55 M 1 5.46 5.16 P 1 14.61 14.35

Mounting Dimensions Letter Maximum Minimum mm mm a 3 19.61 19.30 c 3 15.04 14.78 I 3 1.54 1.22