Guide to Intel Rapid Storage



Similar documents
Intel Matrix Storage Manager 8.x

Intel Rapid Storage Technology

RAID installation guide

Intel Matrix Storage Manager

Guide to SATA Hard Disks Installation and RAID Configuration

Intel Matrix Storage Console

4 Backing Up and Restoring System Software

RAID installation guide for Silicon Image SiI3114

XConsole GUI setup communication manual September 2010.

Vess A2000 Series. NVR Storage Appliance. Windows Recovery Instructions. Version PROMISE Technology, Inc. All Rights Reserved.

File Management Utility. T u t o r i a l

SATA1.5G/ATA133 RAID Controller Card RC215 User Manual

Operating System Installation Guide

AMD RAID Installation Guide

Guide to Installing BBL Crystal MIND on Windows 7

Printer Support Guide. FedEx Ship Manager Software

NVIDIA RAID Installation Guide

This user guide describes features that are common to most models. Some features may not be available on your computer.

This user guide describes features that are common to most models. Some features may not be available on your computer.

SATA RAID Function (Only for chipset Sil3132 used) User s Manual

This user guide describes features that are common to most models. Some features may not be available on your computer.

Chapter 3 Software Installation

Image Backup and Recovery Procedures

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

Serial ATA 2 Ports PCI Host

VT8237 SATA RAID User Manual

SATA+Ultra ATA RAID CONTROLLER RC212. User Manual

64-Bit Compatibility with Micromeritics Applications

Intel ICH7R/ICH9R/ICH10R HostRAID Setup Guidelines

HP User Manual for LSI Integrated RAID on HP xw4200/xw6200/xw8200/xw9300 Workstation

SQL Server 2008 R2 Express Installation for Windows 7 Professional, Vista Business Edition and XP Professional.

Intel ESB2 SATA RAID Setup Guidelines

Colorfly Tablet Upgrade Guide

Using ATI Array Management Software (WebPAM)

A+ Guide to Software: Managing, Maintaining, and Troubleshooting, 5e. Chapter 3 Installing Windows

Using. Microsoft Virtual PC. Page 1

Parallels Desktop for Mac

Chapter 1 Downloading Images to Your Computer (Windows)

SOFTWARE INSTALLATION INSTRUCTIONS

Configuring ThinkServer RAID 100 on the Lenovo TS130

Keystone 600N5 SERVER and STAND-ALONE INSTALLATION INSTRUCTIONS

SiS S-ATA User s Manual. Quick User s Guide. Version 0.1

Serial ATA RAID PCI. User's Manual

RAID User Guide. Edition. Trademarks V1.0 P/N: C51GME0-00

ThinkServer RS140 Operating System Installation Guide

Intel ICH5R Serial ATA RAID. Quick User s Guide

Getting Started User s Guide

Onboard-RAID. Onboard-RAID supports striping (RAID 0), mirroring (RAID 1), striping/mirroring (RAID 0+1), or spanning (JBOD) operation, respectively.

Microsoft BackOffice Small Business Server 4.5 Installation Instructions for Compaq Prosignia and ProLiant Servers

Image Backup and Recovery Procedures

Paragon Backup Retention Wizard

M5281/M5283. Serial ATA and Parallel ATA Host Controller. RAID BIOS/Driver/Utility Manual

requirements the Boot Camp boot camp in into Spotlight. 2. If proceeding. 2 Windows 3 Windows

SATA II 4 Port PCI RAID Card RC217 User Manual

COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS

Promise FastTrak 100-Lite RAID Controller

Windows 7 and USB 3.0 driver installation for 100 Series and Braswell platform

Advanced Host Controller Interface (AHCI) and Redundant Array of Independent Disks (RAID) on HP Compaq dc7800 Business PCs

DataLINE Data Retrieval

October Rev. B Page 1

SiS 180 S-ATA User s Manual. Quick User s Guide. Version 0.1

AMD RAID Installation Guide

Installation Instruction STATISTICA Enterprise Small Business

NOTE: PLEASE DO NOT ATTEMPT TO INSTALL THE SOFTWARE BEFORE READING THIS DOCUMENT.

RAID Manual. Edition. Trademarks V1.0 P/N: CK8-A5-0E

Table of Contents. Configuring IDE RAID Hard Drive(s) (Controller GigaRAID (IT8212))... 2

Magaya Software Installation Guide

RAID installation guide for ITE8212F

GUARD1 PLUS SE Administrator's Manual

HP ProLiant ML110 Server Network Operating System Installation Guide

STATISTICA VERSION 12 STATISTICA ENTERPRISE SMALL BUSINESS INSTALLATION INSTRUCTIONS

Manual OS Installation

Parallels Transporter Agent

Configuring ThinkServer RAID 100 on the TS140 and TS440

Option 1 Using the Undelete PushInstall Wizard.

Data Lifeguard Tools. Software Manual

RAID configuration and driver installation guide

F-Secure Online Backup Quick Installation Guide

Batch Eligibility Long Term Care claims

HP MediaSmart Server Software Upgrade from v.2 to v.3

Installing and Upgrading to Windows 7

Thuraya XT-DUAL. Software Upgrade Manual

Corsair Flash Voyager USB 2.0 Flash Drive UFD Utility User s Manual

Getting Started with VMware Fusion

Cloud Catcher TM Software

VirtualXP Users Guide

Elo 1725L 17 Touch Screen Monitor Installation Guide. Product Name: Elo 1725L 17- inch Monitor

PCLinq2 Hi-Speed USB Bridge-Network Cable. Quick Network Setup Guide

Supporting Users and Troubleshooting a Microsoft Windows XP Operating System Q&A. DEMO Version

Guide to SATA Hard Disks Installation and RAID Configuration

Contents. Hardware Configuration Uninstalling Shortcuts Black...29

Topaz Installation Sheet

Xactimate v.27 Network Installation


Serial ATA RAID PCI Card

AMD RAID Installation Guide

SATA150 TX2PLUS, TX4 QUICK START GUIDE. Version 1.2

Installing SATA Drivers on HP EliteBook Notebook PCs

USB Driver Installation for Windows XP

Copyrights, Legal Notices, Trademarks and Servicemarks

Transcription:

Guide to Intel Rapid Storage Overview I ntel Rapid Storage Technology provides new levels of protection, perform ance, and expandability for desktop and m obile platform s. Whether using one or m ultiple hard drives, users can take advantage of enhanced perform ance and lower power consum ption. When using m ore than one drive, the user can have additional protection against data loss in the event of a hard drive failure. Starting with version 9.5, a brand new user interface m akes creating and m anaging your storage sim ple and intuitive. Com bined with I ntel Rapid Recover Technology, setting up data protection can be accom plished easily with an external drive. I ntel Rapid Storage Technology can also im prove the perform ance of disk intensive retrieval applications such as editing hom e video. By com bining from two to six drives in a RAI D 0 configuration, data can be accessed on each drive sim ultaneously, speeding up response tim e on data-intensive applications. Also, due to drive load balancing, even system s with RAI D 1 can take advantage of faster boot tim es and data reads. I ntel Rapid Storage Technology provides benefits to users of a single drive as well. Through AHCI, storage perform ance is im proved through Native Com m and Queuing (NCQ). AHCI also delivers longer battery life with Link Power Managem ent (LPM), which can reduce the power consum ption of the chipset and Serial ATA (SATA) hard drive. 1

I nstallation I nstructions 1. Download the I ntel Rapid Storage Technology software from I ntel website. Save the file to a known location on your com puter's hard drive. 2. Locate the file on your hard drive and double-click it. 3. Click Continue (if needed) to launch the installation program. 4. Click Next at the Welcom e screen. 5. Click Next. 2

6. Read the license agreem ent and click Yes to accept the term s and continue. 7. Click Next. The application files will now be installed. 3

8. Click Next. 9. Click Yes to the restart option and then click Finish to restart your com puter. 4

10. Restart your system. You will find the I ntel Rapid Storage Technology icon on the Windows task bar. 5

Create a RAI D Array 1. Double-click I ntel Rapid Storage Technology icon, then below m ain screen appears. 2. Click the Create icon to create a RAI D array. Here we take RAI D 1 for exam ple. 3. I n Select Volum e Type, click Real-tim e data protection (RAI D 1). Click Next. 6

4. I n Configure Volum e, you need to key-in the Volum e Nam e with 1-16 letters, select the RAI D disks, and then specify the volum e size. Click Next. 5. I n Confirm Volum e Creation, you m ay review the selected configuration. Then click Create Volum e. 7

6. The volum e is created successfully. But you still need to partition your new volum e by using Windows Desk Managem ent before adding any data. Click OK. 7. You will see the current status. 8

8. I n Windows Desk Managem ent, you need to initialize a disk before Logical Disk Managem ent can access it. Click OK. 9. Right-click on Disk 0, click New Sim ple Volum e. 9

10. Then follow the instructions on the New Sim ple Volum e Wizard. 11. Finally you can start to use RAI D 1 function. 10

Delete a RAI D Array You can also use this utility to delete the RAI D array or configure other RAI D functions. 11

How to install an operating system onto a RAI D volum e ( F6 install m ethod) I n order to install an operating system onto a RAI D volum e, the RAI D option m ust be enabled in the system BI OS, a RAI D volum e m ust be created, and the F6 installation m ethod m ust be used to load the I ntel Rapid Storage Technology driver during operating system setup. Note The F6 installation m ethod is not required for Microsoft Windows Vista* or Microsoft Windows 7*. Enable RAI D in System BI OS Use the instructions included with your m otherboard to enable RAI D in the system BI OS. 1. Click F2 or Delete to enter the BI OS Setup program after the Power-On-Self-Test (POST) m em ory test begins. 2. Enetr the Advanced m enu. 3. Click the Storage Configuration m enu. 4. Switch the SATA Operation Mode option to RAI D. 5. Click F1 0 to save the BI OS settings and exit the BI OS Setup program. Create a RAI D Volum e Use the following steps to create a RAI D volum e. 1. When the I ntel Rapid Storage Technology option ROM status screen appears during POST, press Ctrl and i at the sam e tim e to enter the option ROM user interface. 2. Select 1 : Create RAI D Volum e and press Enter. 3. Use the up or down arrow keys to select the RAI D level and press Enter. 4. Unless you have selected RAI D 1, use the up or down arrow keys to select the strip size and press Enter. 5. Press Enter to select the physical disks. 6. Select the appropriate num ber of hard drives by using the up or down arrow keys to scroll through the list of hard drives and press Space to select the drive. When finished press Enter. 12

7. Select the volum e size and press Ent er. 8. Press Enter to create the volum e. 9. At the prom pt press Y to confirm volum e creation. 10. Select 4 : Exit and press Enter. 11. Press Y to confirm your exit. I nst all the RAI D Driver Using the F6 I nstallation Method Perform the following steps to install the I ntel Rapid Storage Technology driver during operating system setup: 1. Press F6 when you see a m essage in the status line that says, Press F6 if you need to install a third party SCSI or RAI D driver. This m essage appears at the beginning of Windows XP* setup (during text-m ode phase). Note Nothing will happen im m ediately after pressing F6. Setup will tem porarily continue loading drivers. You will then be prom pted with a screen asking you to load support for m ass storage device(s). 2. Press S to Specify Additional Device. 3. When you see a prom pt that says, Please insert the disk labeled Manufacturer-supplied hardware support disk into Drive A:, insert ; a floppy disk containing the following files: I AAHCI.I NF, I AAHCI.CAT, I ASTOR.I NF, I ASTOR.CAT, I ASTOR.SYS, and TXTSETUP.OEM. Note Use the Floppy Configuration Utility to create a floppy disk with the necessary files. 4. Press Enter. 5. Select your controller from the list of available SCSI adapters. Use the up and down arrow keys to scroll through the list as all controllers m ay not be visible. 6. Press Enter to confirm your controller and continue. At this point, you have successfully installed the driver and Windows setup should continue. Leave 13

the floppy disk in the floppy drive until the system reboots. Windows setup will need to copy the files again from the floppy to the Windows installation folders. Once Windows setup has copied these files again, rem ove the floppy disk so that Windows setup can reboot as needed. 7. During Windows setup, create a partition and file system on the RAI D volum e as you would on any physical disk. Note I f you wish to use the I ntel Rapid Storage Technology user interface in Windows, you will need to install I ntel Rapid Storage Technology by running the Setup.exe process after these steps have been com pleted and the operating system has been successfully installed. 14

W hat if I w ant to use RAI D but m y OS is already installed? I f your operating system is already installed, you can still use RAI D as long as the following conditions are m et: Your system has a RAI D I / O controller hub (I CH). Note I f your syst em does not have a RAI D I CH, you will not be able t o use RAI D without installing a third-party RAI D controller card. Your RAI D controller is enabled. W arning I f your RAI D controller is not enabled, enabling the RAI D controller is not recom m ended or supported when a SATA hard drive is the boot drive. Enabling the RAI D controller m ay cause an im m ediate blue screen with an 0x0000007b error code, followed by a reboot. I f you wish to enable it, you will need to reinstall the operating system. I f both of the above conditions are m et, use the following steps to create a RAI D volum e. 1. I nstall I ntel Rapid Storage Technology. 2. Turn off the system and install one or m ore additional hard drives. 3. Turn on the system. 4. Use the I ntel Rapid Storage Technology user interface to create a RAI D volum e. You can m igrate the data from a single hard drive on your system to a RAI D volum e that includes that hard drive plus the newly added hard drive(s). You can also create a new RAI D volum e using the newly added hard drives. 15

How to load the driver during OS installation using F6 w hen in AHCI / RAI D m ode I n order to install an operating system onto a single Serial ATA hard drive when the syst em is in RAI D m ode or AHCI m ode, t he F6 inst allat ion m et hod m ust be used t o load the I ntel Rapid Storage Technology driver during operating system installation. You do not need to use the F6 installation m ethod to install a RAI D Note driver on Microsoft Windows Vista* and Microsoft Windows 7* because I ntel provided a RAI D driver as part of the final package. Use the following steps to install the I ntel Rapid Storage Technology driver using the F6 installation m ethod. 1. Press F6 when you see a m essage in the status line that says, Press F6 if you need to install a third party SCSI or RAI D driver. This m essage appears at the beginning of Windows XP* setup (during text-m ode phase). Nothing will happen im m ediately after pressing F6. Setup will Note tem porarily continue loading drivers. You will then be prom pted with a screen asking you to load support for m ass storage device(s). 2. Press S to Specify Additional Device. 3. When you see a prom pt that says, Please insert the disk labeled Manufacturer-supplied hardware support disk into Drive A:, insert a floppy disk containing the following files: I AAHCI.I NF, I AAHCI.CAT, I ASTOR.I NF, I ASTOR.CAT, I ASTOR.SYS, and TXTSETUP.OEM. Note You can use the Floppy Configuration Utility to create a floppy disk with the necessary files. I f you do not have a floppy drive on your system, you can use a USB floppy drive or create a slipstream version of the operating system. 16

4. Press Enter. 5. Select your controller from the list of available SCSI adapters. Use the up and down arrow keys to scroll through the list as all controllers m ay not be visible. 6. Press Enter to confirm your controller and continue. At this point, you have successfully installed the I ntel Rapid Storage Technology driver and Windows setup should continue. Leave the floppy disk in the floppy drive until the system reboots. Windows setup will need to copy the files again from the floppy to the Windows installation folders. Once Windows setup has copied these files again, rem ove the floppy disk so that Windows setup can reboot as needed. Note I f you wish to use the I ntel Rapid Storage Technology user interface within Windows, you will need to run Setup.exe from within Windows. 17

How to do unattended install of AHCI / RAI D driver on W indow s 2 0 0 0 / XP/ Server 2 0 0 3 * The unattended m ethod of installation is available for Microsoft Windows XP*, Windows 2000* and Windows Server 2003*. I t is used to install the RAI D or AHCI driver, as outlined in the Microsoft docum ent Deploym ent Guide Autom ating Windows NT* Setup. Perform the following steps in order to install the RAI D or AHCI driver via unattended install. 1. Extract the I AAHCI.I NF, I AAHCI.CAT, I ASTOR.I NF, I ASTOR.CAT, I ASTOR.SYS, and TXTSETUP.OEM files from the setup files. To extract these files, run the executable (e.g. I ATA88ENU.EXE for I ntel Matrix Storage Manager version 8.8) with the following com m and line options: -A -A -PC: \ < path>, as described in the Advanced I nstallation I nstructions section of the README.TXT. Does the system contain a 32-bit or 64-bit processor? o o I f the system has a 32-bit processor, the files will be located in the Drivers folder after extraction. I f the system has a 64-bit processor, the files will be located in the Drivers64 folder after extraction. 2. I nsert the lines shown below, as applicable, into the UNATTEND.TXT file: System s configured for RAI D: Note This sam e procedure can be used for system s using any supported RAI D controller hub by replacing the text within the quotation m arks. / / I nsert the lines below into the UNATTEND.TXT file [ MassStorageDrivers] "I ntel(r) 82801R/ DO/ DH SATA RAI D Controller" = OEM 18

[ OEMBootFiles] iastor.inf iastor.sys iastor.cat Txtsetup.oem System s configured for AHCI : Note This sam e procedure can be used for system s using any supported AHCI controller hub by replacing the text within the quotation m arks. / / I nsert the lines below into the UNATTEND.TXT file [ MassStorageDrivers] "I ntel(r) 82801R/ DO/ DH SATA AHCI Controller" = OEM [ OEMBootFiles] iaahci.inf iastor.sys iaahci.cat Txtsetup.oem 3. Place I AAHCI.CAT, I AAHCI.I NF, I ASTOR.CAT, I ASTOR.I NF, I ASTOR.SYS, and TXTSETUP.OEM into the following folder: < System Root> : \ i386\ $OEM$\ Textm ode Operating System : Windows* 2000, Windows* XP Professional, Windows* XP Hom e Edition, Windows Server* 2003 19