Installing SATA Drivers on HP EliteBook Notebook PCs
|
|
|
- Hector Malone
- 9 years ago
- Views:
Transcription
1 Installing SATA Drivers on HP EliteBook Notebook PCs Introduction... 2 Purpose... 2 Audience... 2 Benefits of SATA... 2 System Requirements and Prerequisites... 2 System requirements... 2 System prerequisites... 2 Transitioning a Sysprep image from IDE to SATA... 3 Where these guidelines are applicable... 3 Steps to add SATA support to the original image...3 Adding SATA drivers to RIS Installation Points... 5 Where these guidelines are applicable... 5 Steps to add SATA drivers to the distribution point... 5 Adding SATA Drivers to an Installation CD... 7 Where these guidelines are applicable... 7 Steps to add SATA drivers to the CD... 7 Using OSCDIMG (or CDIMAGE) and CDBURN (command line utilities from Microsoft)... 9 Adding SATA Drivers to WinPE Where these guidelines are applicable Steps to add SATA drivers to WinPE Modifying a Windows XP installation to support SATA Native Mode Where these guidelines are applicable Steps to modify a Windows XP image to support SATA Native Mode How to Obtain SATA Device IDs Where these guidelines are applicable Steps to obtain the SATA Device ID from a Windows XP image Steps to obtain the SATA Device ID from a Windows Vista image For more information... 20
2 Page 2 Introduction Purpose This white paper provides instructions on how to successfully incorporate SATA drivers into a Windows XP installation on HP EliteBook Notebook PC models. The following guidelines provide procedures for adding SATA drivers to RIS (Remote Installation Service) installation points; adding SATA drivers to installation CDs; building an image and switching to SATA AHCI mode; using Sysprep with SATA in AHCI or NATIVE mode; and adding SATA drivers using WinPE. Audience This white paper is for use by HP personnel and customers. Benefits of SATA SATA Native Mode is a storage interface technology that provides up to 150MB/Sec transfer rate for disk traffic, and provides link power management with Intel Application Accelerator drivers. Intel Matrix Storage Manager Driver provides support for the SATA Advanced Host Controller (AHCI) Interface. System Requirements and Prerequisites System requirements Information regarding minimum hardware requirements for installing XP Professional is available at This document applies to all systems using Intel Matrix SATA AHCI Storage controllers. System prerequisites You will need the following items before installing SATA drivers: Microsoft Windows XP Professional Service Pack 2, Certificate of Authenticity and documentation. Necessary drivers, especially Intel SATA AHCI Controller Driver. Proper OS License for each PC IMPORTANT: Make sure you have the latest compatible version of Microsoft Windows XP drivers and enhancements. In addition, you must have a Microsoft OS license for each system on which you install Windows XP Professional. Note: You can also download HP drivers and utilities, including the most current available ROM for the platform, from the HP website
3 Page 3 Transitioning a Sysprep image from IDE to SATA Where these guidelines are applicable IMPORTANT: Follow the installation instructions in the order provided. Failure to complete these steps in the proper order can result in an unsuccessful or unstable installation. This section provides guidelines for customers who need to add SATA support to a sysprep image. Sysprep images with no SATA support will display a blue screen and reboot very quickly in an infinite loop. Adding SATA drivers to the image will allow XP to access the disk and finish booting. Note: PCI IDs for current HP desktop and workstation Intel SATA controllers are included in step 5. Although this whitepaper is intended to cover HP Notebook PCs, this section should also be applicable to HP desktop and workstation PCs. Steps to add SATA support to the original image 1) Download and save the "Intel Matrix Storage Manager" softpaq that is available for your platform at 2) Unpack all the files from the SoftPaq. Unpacking a Softpaq file uses this command line: Sp#####.exe -e -f<path> -s Where o SP####.exe is the Softpaq to unpack. o -e is a run time switch that overrides installation of the component inside the softpaq. o -f<path> is a run time switch that overrides the default path set at build time. o -s instructs the package to unpack in silent mode skipping the welcome, license and directory screens. Example: C:\tmp\sp99999.exe -e -fc:\sp s This will unpack the files needed to c:\sp ) Browse to the location of the Intel storage drivers on your system. Using the example above that would be c:\sp99999\winall\driver (for XP32) or c:\sp99999\winall\driver64 (for XP64). Copy the files in that directory to removable media (i.e. floppy disk, usb key). a. iaahci.cat b. iaahci.inf c. iastor.cat d. iastor.inf e. iastor.sys f. txtsetup.oem
4 Page 4 4) On the system you intend to Sysprep, add the first 5 files (a through e, from above) to the PnP drivers store (example: c:\drivers\sata). 5) Obtain the SATA Device ID as described in the section How to Obtain SATA Device IDs of this document and insert them where [SATA Device ID] is seen below. Add the following section to your c:\sysprep\sysprep.inf file: [SysprepMassStorage] [SATA Device ID] = %systemdrive%\drivers\sata\iaahci.inf ; [optional description] [SATA Device ID]= %systemdrive%\drivers\sata\iastor.inf ; [optional description] Please note that each line to be added starts with PCI\. These lines are continued over to a second row in this paper due to space limitations. In addition, the text displayed after the semicolon (;) is an example of optional text that can be used to identify which SATA Device ID is being inserted. This is entirely optional text which can be modified or completely removed at the customer s discretion. 6) Add or edit the following section of sysprep.inf to add the SATA drivers to the PnP drivers path. [Unattended] OemSkipEula=Yes OemPnPDriversPath=drivers\sata;<your driver list will come here> ConfirmHardware=No OverwriteOemFilesOnupgrade=No DriverSigningPolicy = Ignore oempreinstall=yes updateinstalleddrivers=yes 7) At this point, the Windows installation is ready for deployment. Run Sysprep on the updated OS, capture an image, and deploy the image to systems using SATA hardware set to the default AHCI SATA Native mode.
5 Page 5 Adding SATA drivers to RIS Installation Points Where these guidelines are applicable IMPORTANT: Follow the installation instructions in the order provided. Failure to complete these steps in the proper order can result in an unsuccessful or unstable installation. This section provides guidelines for customers who need to add SATA support to a Remote Installation Service distribution point. Steps to add SATA drivers to the distribution point 1) Download and save the "Intel Matrix Storage Manager" softpaq that is available for your platform at 2) Unpack all the files from the SoftPaq. Unpacking a Softpaq file uses this command line: Sp#####.exe -e -f<path> -s Where o SP####.exe is the Softpaq to unpack. o -e is a run time switch that overrides installation of the component inside the softpaq. o -f<path> is a run time switch that overrides the default path set at build time. o -s instructs the package to unpack in silent mode skipping the welcome, license and directory screens. Example: C:\tmp\sp99999.exe -e -fc:\sp s This will unpack the files needed to c:\sp ) Browse to the location of the Intel storage drivers on your system. Using the example above that would be c:\sp99999\winall\driver (for XP32) or c:\sp99999\winall\driver64 (for XP64). Copy the files in that directory to removable media (i.e. floppy disk, usbkey). a. iaahci.cat b. iaahci.inf c. iastor.cat d. iastor.inf e. iastor.sys f. txtsetup.oem 4) Copy all the files above to the following path on the distribution point (on the RIS server): RemoteInstall\Setup\<Language>\Images\<Dir_name>\i386 5) Also copy the same files (from step 3, above) to RemoteInstall\Setup\<Language>\Images\<Dir_name>\$oem$\$1\drivers\s ata
6 Page 6 6) Open RemoteInstall\Setup\<Language>\Images\<Dir_name>\i386 \txtsetup.sif in Notepad. 7) Go to the end of the file. There will be several blank lines. 8) Move the cursor up a few lines. This is necessary because there is a hidden marker at the end of the file. 9) Add the following lines to the txtsetup.sif file. For the HardwareIdsDatabase, multiple device IDs can be added here using any of the SATA Device IDs obtained from the section of this document titled How to Obtain SATA Device IDs. Simply replace the [SATA Device IDs] with the Device ID you received from the system. Only one is needed, but multiple IDs can be inserted for additional support of multiple SATA Device Controllers. [SourceDisksFiles] iastor.sys= 1,,,,,,4_,4,1,,,1,4 iaahci.cat=1,,,,,,,20,0,0 iaahci.inf=1,,,,,,,20,0,0 iastor.cat=1,,,,,,,20,0,0 iastor.inf=1,,,,,,,20,0,0 [HardwareIdsDatabase] [SATA Device ID1] = "iastor" [SATA Device ID2] = "iastor" [SATA Device ID3] = "iastor" [SATA Device ID4] = "iastor" [SATA Device ID...] = "iastor" [SCSI.Load] iastor = iastor.sys,4 [SCSI] iastor = "Intel(R) SATA RAID/AHCI Controller (ICH5,6,7)" 10) Save the file and exit notepad. 11) Open any other.sif file(s) in the path: RemoteInstall\Setup\<Language>\Images\<Dir_name>\i386\xxxx.sif with notepad 12) In these files, under the section [Unattended], add the following lines: OemPreinstall=yes OemPnPDriversPath=drivers\sata DriverSigningPolicy = Ignore 13) Save all your edited.sif file(s), and close notepad 14) Restart the Remote Installation Service (binlsvc).
7 Page 7 Adding SATA Drivers to an Installation CD Where these guidelines are applicable IMPORTANT: Follow the installation instructions in the order provided. Failure to complete these steps in the proper order can result in an unsuccessful or unstable installation. This section provides guidelines for customers who need to add SATA support by creating a custom Windows XP Service Pack 2 Installation CD. Steps to add SATA drivers to the CD 1) Copy all the directories and files from the Windows XP CD to a temporary folder (these guidelines will use c:\xpcd) 2) Download and save the "Intel Matrix Storage Manager" softpaq that is available for your platform at 3) Unpack all the files from the SoftPaq. Unpacking a Softpaq file uses this command line: Sp#####.exe -e -f<path> -s Where o SP####.exe is the Softpaq to unpack. o -e is a run time switch that overrides installation of the component inside the softpaq. o -f<path> is a run time switch that overrides the default path set at build time. o -s instructs the package to unpack in silent mode skipping the welcome, license and directory screens. Example: C:\tmp\sp99999.exe -e -fc:\sp s This will unpack the files needed to c:\sp ) Browse to the location of the Intel storage drivers on your system. Using the example above that would be c:\sp99999\winall\driver (for XP32) or c:\sp99999\winall\driver64 (for XP64). Copy the files in that directory to removable media (i.e. floppy disk, usb key). a. iaahci.cat b. iaahci.inf c. iastor.cat d. iastor.inf e. iastor.sys f. txtsetup.oem 5) Create the following path in the temporary folder: c:\xpcd\$oem$\$1\drivers\sata 6) Copy all the files from step 4 to the c:\xpcd\i386 folder. 7) Also copy all the files from step 4 to the c:\xpcd\$oem$\$1\drivers\sata folder.
8 Page 8 8) Open the c:\xpcd\i386\txtsetup.sif file in Notepad. 9) Go to the end of the file. There will be several blank lines. 10) Move the cursor up a few lines. This is necessary because there is a hidden marker at the end of the file. 11) Add the following lines. For the HardwareIdsDatabase, multiple device IDs can be added here using any of the SATA Device IDs obtained from the section of this document titled How to Obtain SATA Device IDs. Simply replace the [SATA Device IDs] with the Device ID you received from the system. Only one is needed, but multiple IDs can be inserted for additional support of multiple SATA Device Controllers. [SourceDisksFiles] iastor.sys= 1,,,,,,4_,4,1,,,1,4 iaahci.cat=1,,,,,,,20,0,0 iaahci.inf=1,,,,,,,20,0,0 iastor.cat=1,,,,,,,20,0,0 iastor.inf=1,,,,,,,20,0,0 [HardwareIdsDatabase] [SATA Device ID1] = "iastor" [SATA Device ID2] = "iastor" [SATA Device ID3] = "iastor" [SATA Device ID4] = "iastor" [SATA Device ID...] = "iastor" [SCSI.Load] iastor = iastor.sys,4 [SCSI] iastor = "Intel(R) SATA RAID/AHCI Controller (ICH5,6,7)" 12) Save the file and exit notepad. 13) Extract the files from c:\xpcd\support\tools\deploy.cab to c:\deploytools 14) Create a new winnt.sif: a. Execute setupmgr.exe (extracted from deploy.cab in step 13). b. Select Create new answer file c. Select Unattended Setup d. Select Windows XP Pro e. Select User Interaction desired f. Select Set up from a CD g. Enter desired information under each of the following Settings sections h. Save the file as c:\xpcd\i386\winnt.sif 15) Open the c:\xpcd\i386\winnt.sif in notepad 16) Under the section [Unattended], add the following lines: OemPreinstall=yes OemPnPDriversPath=drivers\sata DriverSigningPolicy = Ignore 17) Save winnt.sif and close notepad
9 Page 9 18) Burn the custom XPCD from the c:\xpcd folder. a. Note that the volume label of the CD must be the same as from the original XP CD b. The custom XPCD must be bootable (with the Microsoft bootblock). There are various 3 rd party utilities which can accomplish this. Utilities from Microsoft are available, as detailed in the following section. Using OSCDIMG (or CDIMAGE) and CDBURN (command line utilities from Microsoft) Note: You will need the OSCDIMG and CDBURN utilities. OSCDIMG is found in the WinPE toolkit folder or the OPK. CDBURN is included in the Windows Resource Kits. 1) To create the.iso, use oscdimg l <your XP cd label> -b ETFSBOOT.COM -n c:\xpcd c:\xpcd.iso 2) To create the CD, use Cdburn <cd-drive-letter:> c:\xpcd.iso
10 Page 10 Adding SATA Drivers to WinPE 2005 Where these guidelines are applicable IMPORTANT: Follow the installation instructions in the order provided. Failure to complete these steps in the proper order can result in an unsuccessful or unstable installation. This section provides guidelines for customers who need to add SATA support to a WinPE ISO or DOK. Steps to add SATA drivers to WinPE ) Create the WinPE folder (these guidelines will use c:\winpe) 2) Download and save the "Intel Matrix Storage Manager" softpaq that is available for your platform at 3) Unpack all the files from the SoftPaq. Unpacking a Softpaq file uses this command line: Sp#####.exe -e -f<path> -s Where o SP####.exe is the Softpaq to unpack. o -e is a run time switch that overrides installation of the component inside the softpaq. o -f<path> is a run time switch that overrides the default path set at build time. o -s instructs the package to unpack in silent mode skipping the welcome, license and directory screens. Example: C:\tmp\sp99999.exe -e -fc:\sp s This will unpack the files needed to c:\sp ) Browse to the location of the Intel storage drivers on your system. Using the example above that would be c:\sp99999\winall\driver (for XP32) or c:\sp99999\winall\driver64 (for XP64). Copy the files in that directory to removable media (i.e. floppy disk, usbkey). a. iaahci.cat b. iaahci.inf c. iastor.cat d. iastor.inf e. iastor.sys f. txtsetup.oem 5) Copy the iaahci.inf and iastor.inf files from the floppy to the c:\winpe\i386\inf folder. 6) Copy the other files to the c:\winpe\i386\system32\drivers folder. 7) Open c:\winpe\i386\txtsetup.sif in Notepad.
11 Page 11 8) Go to the end of the file. There will be several blank lines 9) Move the cursor up a few lines. This is necessary because there is a hidden marker at the end of the file. 10) Add the following lines to the txtsetup.sif. For the HardwareIdsDatabase, multiple device IDs can be added here using any of the SATA Device IDs obtained from the section of this document titled How to Obtain SATA Device IDs. Simply replace the [SATA Device IDs] with the Device ID you received from the system. Only one is needed, but multiple IDs can be inserted for additional support of multiple SATA Device Controllers. [SourceDisksFiles] iastor.sys= 1,,,,,,4_,4,1,,,1,4 iaahci.cat=1,,,,,,,20,0,0 iaahci.inf=1,,,,,,,20,0,0 iastor.cat=1,,,,,,,20,0,0 iastor.inf=1,,,,,,,20,0,0 [HardwareIdsDatabase] [SATA Device ID1] = "iastor" [SATA Device ID2] = "iastor" [SATA Device ID3] = "iastor" [SATA Device ID4] = "iastor" [SATA Device ID...] = "iastor" [SCSI.Load] iastor = iastor.sys,4 [SCSI] iastor = "Intel(R) SATA RAID/AHCI Controller (ICH5,6,7)" 11) Save the file and exit Notepad. 12) Create the WinPE.ISO file or DOK from c:\winpe. This is done in the usual manner.
12 Page 12 Modifying a Windows XP installation to support SATA Native Mode Where these guidelines are applicable IMPORTANT: Follow the installation instructions in the order provided. Failure to complete these steps in the proper order can result in an unsuccessful or unstable installation. This section provides guidelines for customers who have built an image with SATA AHCI Native Mode disabled in F10 Setup, and need to modify the image to support SATA AHCI Native Mode enabled (the default mode). This section is intended for customers who have not yet modified their overall process using one of the previous methods, and need an expedient method of imaging a system. This section provides guidelines for disabling SATA native mode in F10 setup, building the image, adding the drivers for SATA AHCI to the image, and re-enabling SATA native mode in F10 setup. Steps to modify a Windows XP image to support SATA Native Mode 1) Enter F10 Setup, and go to System Configuration/Device Configurations/SATA Native Mode to Disable. 2) Install Windows XP Service Pack 2 in whatever manner is typical for your organization. 3) Download and save the "Intel Matrix Storage Manager" softpaq that is available for your platform at 4) Unpack all the files from the SoftPaq. Unpacking a Softpaq file uses this command line: Sp#####.exe -e -f<path> -s Where o SP####.exe is the Softpaq to unpack. o -e is a run time switch that overrides installation of the component inside the softpaq. o -f<path> is a run time switch that overrides the default path set at build time. o -s instructs the package to unpack in silent mode skipping the welcome, license and directory screens. Example: C:\tmp\sp99999.exe -e -fc:\sp s This will unpack the files needed to c:\sp ) Browse to the location of the Intel storage drivers on your system. Using the example above that would be c:\sp99999\winall\driver (for XP32) or c:\sp99999\winall\driver64 (for XP64). Copy the files in that directory to removable media (i.e. floppy disk, usbkey). a. iaahci.cat b. iaahci.inf c. iastor.cat d. iastor.inf e. iastor.sys
13 Page 13 f. txtsetup.oem a. 6) Download and run the Intel Chipset Installation Utility for ICH9 for Microsoft Windows 2000 and XP for your models from 7) In Device Manager, right-click the IDE ATA/ATAPI controllers/intel ICH9M Serial ATA Storage Controller and select Update Driver. If more than one Intel ICH9M Serial ATA Storage Controller is listed this process only needs to be done once. 8) Follow these steps to complete the Hardware Update Wizard: a. At the first dialog, select No, not this time when prompted to connect to Windows Update. b. At the next dialog, select Install from a list or specific location (Advanced). c. At the next dialog, select Don t search. I will choose the driver to install. d. When prompted to select the device driver you want to install for this hardware, choose the first one in the list: Intel ICH9M Serial ATA Storage Controller. e. When prompted to insert the manufacturer s installation disk, select Have Disk and when prompted, browse to the location of the Intel Matrix Storage Manager files extracted from the softpaq on your removable media. f. Select iaahci.inf and click Open, then OK. g. When prompted to select the device driver you want to install for this hardware, select the Intel ICH9M-E/M SATA AHCI Controller. h. A warning that Windows cannot verify that the device is compatible with your hardware will appear. When asked if you want to continue installing the driver, select Yes, then Finish. i. The installation will complete. 9) Shut down Windows and restart the computer. Enter F10 setup when prompted during the boot. 10) Go to System Configuration/Device Configurations/SATA Native Mode and change it to Enable, then save settings and exit F10 Setup. 11) After Windows restarts, the additional SATA components will be updated. A System Settings Change will appear. When asked Do you want to restart your computer now? click Yes. 12) When Windows restarts, the SATA AHCI drivers will be completely installed.
14 Page 14 How to Obtain SATA Device IDs Where these guidelines are applicable This section provides guidelines for customers who need the SATA Device ID from an HP system to enable SATA AHCI support in custom images. Steps are provided for both Windows XP and Windows Vista. Steps to obtain the SATA Device ID from a Windows XP image 1) Begin by taking a Windows XP system with the HP image already on it. Turn on the system and boot into the Operating System. 2) Once the Operating System is loaded, select the Start Button and choose Run. 3) When the Run dialogue box appears, type the following command: devmgmt.msc Press the OK button to launch the Device Manager console. Refer to the screenshot below for this step.
15 Page 15 4) When the Device Manager Console opens, scroll down to locate & expand the category for IDE ATA/ATAPI controllers as seen in the screenshot below: 5) Double click on the listed SATA AHCI Controller to bring up the device s property window.
16 Page 16 6) In the device property window, select the Details tab and choose Hardware Ids from the drop-down menu as seen in the screenshot below. The Device ID needed from the list is the one with the simple Class Code Hardware ID (identified with a CC string in the name). In the example below, the Device ID needed is PCI\VEN_8086&DEV_2929&CC_0106.
17 Page 17 Steps to obtain the SATA Device ID from a Windows Vista image 1) Begin by taking a Windows Vista system with the HP image already on it. Turn on the system and boot into the Operating System. 2) Once the Operating System is loaded, select the Start Button and type the following command: devmgmt.msc Pressing the Enter key after typing the above command will launch the Device Manager console. Refer to the screenshot below for this step.
18 Page 18 3) When the Device Manager Console opens, scroll down to locate & expand the category for IDE ATA/ATAPI controllers as seen in the screenshot below: 4) Double click on the listed SATA AHCI Controller to bring up the device s property window.
19 5) In the device property window, select the Details tab and choose Hardware Ids from the drop-down menu as seen in the screenshot below. The Device ID needed from the list is the one with the simple Class Code Hardware ID (identified with a CC string in the name). In the example below, the Device ID needed is PCI\VEN_8086&DEV_2929&CC_0106. Page 19
20 Page 20 For more information To learn more about HP business notebooks, contact your local HP sales representative or visit our Web site at: Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation. Intel and Pentium are U.S. registered trademarks of Intel Corporation. c ,11/2008
Installing Microsoft Windows on an HP ProBook or EliteBook Notebook PC and creating an image
Installing Microsoft Windows on an HP ProBook or EliteBook Notebook PC and creating an image 2011 Business Notebook Models Technical white paper Table of contents Executive summary... 2 System requirements
Installing Windows XP Professional x64 on the HP Compaq 8510w and 8710w Mobile Workstation
Installing Windows XP Professional x64 on the HP Compaq 8510w and 8710w Mobile Workstation Introduction... 2 System Requirements and Prerequisites... 2 Installing the operating system and system hardware...
HP Compaq notebook common image white paper
HP Compaq notebook common image white paper Introduction... 2 System requirements and prerequisites... 2 Common image preparation using factory preinstalled Windows Vista images... 4 Configuring the Windows
Installing Microsoft Windows on HP Compaq and EliteBook Notebook PCs
Installing Microsoft Windows on HP Compaq and EliteBook Notebook PCs Executive summary... 2 Purpose... 2 Audience... 2 System requirements and prerequisites... 2 Installing the operating system and system
HP dx5150 RAID Installation and Setup Guide Version 1.10. Document Part Number: 403571-001
HP dx5150 RAID Installation and Setup Guide Version 1.10 Document Part Number: 403571-001 July 2005 Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject
HP Thin Client Imaging Tool
HP Thin Client Imaging Tool Table of Contents: Abstract... 1 Introduction... 1 System Requirements... 1 Software... 1 Hardware... 1 Getting Started... 2 Formatting a USB Flash Device... 3 Unpacking the
HP Softpaq Download Manager and HP System Software Manager
Technical white paper HP Softpaq Download Manager and HP System Software Manager A Powerful Combination Table of contents Executive summary... 2 Overview of HP SDM and HP SSM... 2 Use case for HP SDM and
WHITE PAPER. HP Guide to System Recovery and Restore
WHITE PAPER January 2003 Prepared By PSG Product Software Engineering Hewlett-Packard Company CONTENTS Purpose3 Using Safe Mode To Diagnose And Correct Problems 4 Using the Recovery Console To Repair Damaged
installing UEFi-based Microsoft Windows Vista SP1 (x64) on HP EliteBook and Compaq Notebook PCs
installing UEFi-based Microsoft Windows Vista SP1 (x64) on HP EliteBook and Compaq Notebook PCs Table of Contents: Introduction... 1 Step 1... 2 Step 2... 3 Step 3... 5 Step 4... 6 For more information...
HP Personal Workstations Step-By- Step Instructions for Upgrading Windows Vista or Windows XP Systems to Windows 7
HP Personal Workstations Step-By- Step Instructions for Upgrading Windows Vista or Windows XP Systems to Windows 7 September 15, 2009 Introduction HP is committed to supporting our customer s operating
Using esata on HP Compaq dc7900 Business PCs
Using esata on HP Compaq dc7900 Business PCs Introduction............................................................ 2 Benefits of esata........................................................2 BIOS /
How to Install Windows XP on a Satellite L40 Non-OS Model. Copyright 2007 Toshiba Corporation. All rights reserved.
How to Install Windows XP on a Satellite L40 Non-OS Model Copyright 2007 Toshiba Corporation. All rights reserved. Introduction The manual installation of Windows XP on a modern TOSHIBA notebook making
Intel Matrix Storage Manager 8.x
Intel Matrix Storage Manager 8.x User's Manual January 2009 Revision 1.0 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
HP SoftPaq Download Manager and HP System Software Manager A Powerful Combination
HP SoftPaq Download Manager and HP System Software Manager A Powerful Combination Technical white paper Table of contents Executive summary... 2 Overview of HP SDM and HP SSM... 2 Use Case for SDM/SSM...
STATISTICA VERSION 10 STATISTICA ENTERPRISE SERVER INSTALLATION INSTRUCTIONS
Notes: STATISTICA VERSION 10 STATISTICA ENTERPRISE SERVER INSTALLATION INSTRUCTIONS 1. The installation of the STATISTICA Enterprise Server entails two parts: a) a server installation, and b) workstation
Instructions for installing Microsoft Windows Small Business Server 2003 R2 on HP ProLiant servers
Instructions for installing Microsoft Windows Small Business Server 2003 R2 on HP ProLiant servers integration note Abstract... 2 Installation requirements checklists... 3 HP ProLiant server checklist...
Configuring HP Elite, EliteBook, and Z220 systems for Intel Smart Response Technology
Technical white paper Configuring HP Elite, EliteBook, and Z220 systems for Intel Smart Response Technology Table of contents Overview 2 System requirements 3 How to enable Intel Smart Response Technology
Transition from PATA optical disc drives to SATA optical disc drives
Transition from PATA optical disc drives to SATA optical disc drives Transition from PATA optical disc drives to SATA optical disc drives... 1 Background... 2 Scope... 2 Definitions... 2... 2 Bootable
Serial ATA 2 Ports PCI Host
Serial ATA 2 Ports PCI Host This Manual is for the various Model of 2ports SATA HBA: Model A: Low Profile Serial ATA Internal 2 Ports Model B: Low Profile External 1 Port + Internal 1 Port Model C: Low
HP Compaq Thin Client Imaging Tool HP Compaq Thin Client t5000 Series
thin clients april 2003 instructions. HP Compaq Thin Client Imaging Tool HP Compaq Thin Client t5000 Series Table Of Contents Table Of Contents... 1 Abstract... 2 Introduction... 2 System Requirements...
Advanced Host Controller Interface (AHCI) and Redundant Array of Independent Disks (RAID) on HP Compaq dc5850 Business PCs
Advanced Host Controller Interface (AHCI) and Redundant Array of Independent Disks (RAID) on HP Compaq dc5850 Business PCs Using AMD Array Management Software (RAIDXpert) Introduction............................................................2
STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER
Notes: STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER 1. These instructions focus on installation on Windows Terminal Server (WTS), but are applicable
Installing Microsoft Windows 8 on HP ElitePad 900 G1 Tablet
Technical white paper Installing Microsoft Windows 8 on HP ElitePad 900 G1 Tablet Commercial Managed IT Table of contents Executive summary... 2 System requirements and prerequisites... 2 Installing the
HP Notebook Hard Drives & Solid State Drives. Identifying, Preventing, Diagnosing and Recovering from Drive Failures. Care and Maintenance Measures
HP Notebook Hard Drives & Solid State Drives Identifying, Preventing, Diagnosing and Recovering from Drive Failures Care and Maintenance Measures Technical White Paper Table of contents Identifying, Preventing,
Microsoft BackOffice Small Business Server 4.5 Installation Instructions for Compaq Prosignia and ProLiant Servers
Integration Note October 2000 Prepared by OS Integration Engineering Compaq Computer Corporation Contents Introduction...3 Requirements...3 Minimum Requirements...4 Required Information...5 Additional
Intel Rapid Start Technology (FFS) Guide
Intel Rapid Start Technology (FFS) Guide Technical white paper Table of contents Intel Rapid Start Technology (FFS) Guide... 2 Product Definition... 2 Requirements... 2 Enabling Intel Rapid Start Technology...
Microsoft Windows XP Service Pack 1 on Compaq Evo Notebooks
White Paper September 2002 Prepared by: PSG Notebook Software Marketing and Engineering Compaq Computer Corporation Contents Introduction... 3 Tested Systems... 3 Installation tips for Service Pack 1...
Intel Rapid Storage Technology
Intel Rapid Storage Technology User Guide August 2011 Revision 1.0 1 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
Administering Windows-based HP Thin Clients with System Center 2012 R2 Configuration Manager SP1
Technical white paper Administering Windows-based HP Thin Clients with System Center 2012 R2 Configuration Manager SP1 Table of contents Executive summary... 3 Configuration Manager features... 3 Asset
Installing Microsoft Windows
Installing Microsoft Windows on HP Workstations with Advanced Format Hard Drives Technical white paper Table of contents Introduction... 2 Identifying an Advanced Format drive... 2 Installing Windows on
Using HP System Software Manager for the mass deployment of software updates to client PCs
Using HP System Software Manager for the mass deployment of software updates to client PCs Introduction... 2 HP manageability solutions... 2 SSM overview... 3 Software updates... 3 Why not SSM-enabled?...
Iridium Extreme TM Satellite Phone. Data Services Manual
Iridium Extreme TM Satellite Phone Data Services Manual Table of Contents 1 OVERVIEW... 1 2 HOW IT WORKS... 1 3 BEFORE INSTALLING... 2 4 USB DRIVER INSTALLATION... 3 5 MODEM INSTALLATION AND CONFIGURATION...
Creating and Restoring Images on the HP Thin Client with Altiris Deployment Server v6.5
Creating and Restoring Images on the HP Thin Client with Altiris Deployment Server v6.5 HP thin clients running Microsoft Windows Embedded Standard 2009 (WES) and Windows XP Embedded (XPe) Table of Contents:
Using ATI Array Management Software (WebPAM)
Redundant Array of Independent Disks (RAID) on HP Compaq dc5750 Business PCs Using ATI Array Management Software (WebPAM) Introduction............................................................ 2 Mirroring
SATA+Ultra ATA RAID CONTROLLER RC212. User Manual
SATA+Ultra ATA RAID CONTROLLER RC212 Contents Feature and benefits Package contents System requirement Magic Switch introduction and jumper setting Hardware installation Important message for user RAID
Image Backup and Recovery Procedures
Image Backup and Recovery Procedures Thank you for purchasing a Fujitsu computer. Fujitsu is committed to bringing you the best computing experience with your new system. It is very important that you
HP One-Button Disaster Recovery (OBDR) Solution for ProLiant Servers
Reference guide HP One-Button Disaster Recovery (OBDR) Solution for ProLiant Servers Reference guide Contents One button disaster recovery (OBDR) 2 Requirements 2 HP tape drive and server support 2 Creating
Using Integrated and Discrete Graphics Simultaneously
Using Integrated and Discrete Graphics Simultaneously For HP Compaq 8200 Elite and 6200 Pro Series desktop models Table of contents Introduction... 2 System requirements... 2 Configuring the system...
VERITAS Backup Exec 9.1 for Windows Servers Quick Installation Guide
VERITAS Backup Exec 9.1 for Windows Servers Quick Installation Guide N109548 Disclaimer The information contained in this publication is subject to change without notice. VERITAS Software Corporation makes
HP Point of Sale (POS) Peripherals Configuration Guide 2D Imaging / Linear / Presentation Scanner
HP Point of Sale (POS) Peripherals Configuration Guide 2D Imaging / Linear / Presentation Scanner Document Version 3.42 December 2011 1 Copyright 2007-2011 Hewlett-Packard Development Company, L.P. The
RAID installation guide
RAID installation guide V1.0 Date : 2009-06-29 TWINHEAD INTERNATIONAL CORP. 10F, 550 Rueiguang Road Neihu, Taipei, Taiwan 114,ROC. TEL(886)2 5589 9999 FAX (886) 2 5555 7777 Enabling RAID in BIOS Perform
ThinkServer RS140 Operating System Installation Guide
ThinkServer RS140 Operating System Installation Guide Note: Before using this information and the product it supports, be sure to read and understand the Read Me First and Safety, Warranty, and Support
This user guide describes features that are common to most models. Some features may not be available on your computer.
RAID User Guide Copyright 2009 Hewlett-Packard Development Company, L.P. Intel is a trademark of Intel Corporation in the U.S. and other countries. Microsoft, Windows, and Windows Vista are U.S. registered
HP External Hard Disk Drive Backup Solution by Seagate User Guide. November 2004 (First Edition) Part Number 373652-001
HP External Hard Disk Drive Backup Solution by Seagate User Guide November 2004 (First Edition) Part Number 373652-001 Copyright 2004 Hewlett-Packard Development Company, L.P. The information contained
Quick start to evaluating HP Windows Embedded Standard 2009 Thin Clients. HP t5630w, HP t5730w, HP t5740, HP gt7720
Get your thin client running Right out of the box Quick start to evaluating HP Windows Embedded Standard 2009 Thin Clients HP t5630w, HP t5730w, HP t5740, HP gt7720 Get your new thin client system up and
Universal Management Service 2015
Universal Management Service 2015 UMS 2015 Help All rights reserved. No parts of this work may be reproduced in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording,
Quick Start to Evaluating. HP t5630w, HP t5730w, HP gt7720
Get your thin client Get your running thin client running Right out Right out of of the box the box Quick Start to Evaluating HP Windows Embedded Standard Thin Clients HP t5630w, HP t5730w, HP gt7720 Get
Parallels Desktop for Mac
Parallels Software International, Inc. Parallels Desktop for Mac Quick Start Guide 3.0 (c) 2005-2007 Copyright 2006-2007 by Parallels Software International, Inc. All rights reserved. Parallels and Parallels
How to Make a USB Bootable
/0/0 Ways to Make a USB Bootable - wiki How to Make a USB Bootable Five Methods: Ad Making a USB Drive to Install Any PC Operating System Making a Windows Vista or 7 Install Drive Creating a USB PC Repair
HP VMware ESXi 5.0 and Updates Getting Started Guide
HP VMware ESXi 5.0 and Updates Getting Started Guide Abstract This guide is intended to provide setup information for HP VMware ESXi. HP Part Number: 616896-002 Published: August 2011 Edition: 1 Copyright
Guide to Intel Rapid Storage
Guide to Intel Rapid Storage Overview I ntel Rapid Storage Technology provides new levels of protection, perform ance, and expandability for desktop and m obile platform s. Whether using one or m ultiple
HP ProLiant DL380 G5 High Availability Storage Server
HP ProLiant DL380 G5 High Availability Storage Server installation instructions *5697-7748* Part number: 5697 7748 First edition: November 2008 Legal and notice information Copyright 1999, 2008 Hewlett-Packard
Image Backup and Recovery Procedures
Image Backup and Recovery Procedures Thank you for purchasing a Fujitsu computer. Fujitsu is committed to bringing you the best computing experience with your new system. It is very important that you
Getting Started. rp5800, rp5700 and rp3000 Models
Getting Started rp5800, rp5700 and rp3000 Models Copyright 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and Windows
Building a Common HP Desktop Software Image Using Microsoft Deployment Toolkit (MDT)
Image Using Microsoft Deployment Toolkit (MDT) Introduction The goal of this document is to guide the IT professional through the process of creating and deploying a common HP Desktop software image utilizing
STATISTICA VERSION 11 CONCURRENT NETWORK LICENSE WITH BORROWING INSTALLATION INSTRUCTIONS
data analysis data mining quality improvement web-based analytics Notes STATISTICA VERSION 11 CONCURRENT NETWORK LICENSE WITH BORROWING INSTALLATION INSTRUCTIONS 1. The installation of the Concurrent network
This user guide describes features that are common to most models. Some features may not be available on your computer.
RAID User Guide Copyright 2011 Hewlett-Packard Development Company, L.P. Intel is a trademark of Intel Corporation in the U.S. and other countries. Microsoft and Windows are U.S. registered trademarks
Installation Instructions for 9555 USB Driver
Prior to using the data modem features of your 9555 handset; you must first install the VCOMPORT 9555 USB Driver. This driver is compatible with: Windows XP Service Pack 2, Windows 2000 Service Pack 4,
Sage Peachtree Installation Instructions
Sage Peachtree Installation Instructions Quick Tips for Network Install Use the following tips to help you install Sage Peachtree on a network: Always install Sage Peachtree FIRST on the computer that
Chapter 3 Software Installation
Software Installation Chapter 3 Software Installation This chapter provides information on how to install the CyberSerial PCI s drivers and utilities for the following operating systems: Windows 95/98
WHITE PAPER. Installing Microsoft Windows 98 on Compaq Armada E, M, and V Portable Products CONTENTS
WHITE PAPER March 2001 Prepared By CPCG Software Product Management Compaq Computer Corporation CONTENTS INTRODUCTION3 CLEAN INSTALLING WINDOWS 983 PREPARING FOR INSTALLATION3 MODIFYING A MICROSOFT DOS
HP Embedded SATA RAID Controller
HP Embedded SATA RAID Controller User Guide Part number: 391679-002 Second Edition: August 2005 Legal notices Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is
HP LaserJet MFP Analog Fax Accessory 300 Send Fax Driver Guide
HP LaserJet MFP Analog Fax Accessory 300 Send Fax Driver Guide Copyright and License 2008 Copyright Hewlett-Packard Development Company, L.P. Reproduction, adaptation, or translation without prior written
VERIZON WIRELESS VZACCESS MANAGER QUICK START GUIDE FOR PC CARDS
VERIZON WIRELESS VZACCESS MANAGER QUICK START GUIDE FOR PC CARDS WELCOME Congratulations on purchasing VZAccess Manager the most popular data connectivity solution for wireless Internet access. This Quick
SATA1.5G/ATA133 RAID Controller Card RC215 User Manual
SATA1.5G/ATA133 RAID Controller Card RC215 Features and Benefits Compliant with Serial ATA 1.0 specification Compliant with PCI Specification, revision 2.2 Provides three independent channels to connect
HP ProLiant ML110 Server Network Operating System Installation Guide
HP ProLiant ML110 Server Network Operating System Installation Guide January 2004 (First Edition) Part Number 344-535-001 Regulatory Model Number HSTNS-3100 2004 Hewlett-Packard Development Company, L.P.
Installation Instruction STATISTICA Enterprise Small Business
Installation Instruction STATISTICA Enterprise Small Business Notes: ❶ The installation of STATISTICA Enterprise Small Business entails two parts: a) a server installation, and b) workstation installations
Intel ICH5R Serial ATA RAID. Quick User s Guide
Intel ICH5R Serial ATA RAID Quick User s Guide Quick User s Guide Version 1.0 G52-M6728X9-K01 1 Edition April 2003 Copyright 2003 MICRO-STAR INT L CO., LTD. The material in this document is the intellectual
HP RDX Continuous Data Protection Software Quickstart Guide
HP RDX Continuous Data Protection Software Quickstart Guide *5697-3351* HP Part Number: 5697-3351 Published: May 2014 Edition: Fourth Copyright 2008 2014 Hewlett-Packard Development Company, L.P. Microsoft,
Installation Instruction STATISTICA Enterprise Server
Installation Instruction STATISTICA Enterprise Server Notes: ❶ The installation of STATISTICA Enterprise Server entails two parts: a) a server installation, and b) workstation installations on each of
Portions of this product were created using LEADTOOLS 1991-2009 LEAD Technologies, Inc. ALL RIGHTS RESERVED.
Installation Guide Lenel OnGuard 2009 Installation Guide, product version 6.3. This guide is item number DOC-110, revision 1.038, May 2009 Copyright 1992-2009 Lenel Systems International, Inc. Information
Important Note Regarding Your Blu ray Drives
Important Note Regarding Your Blu ray Drives Use these supplemental instructions to complete the setup of your unit Your Disc Publisher unit uses esata to connect the Blu-ray drive(s) to the computer.
Install SQL Server 2014 Express Edition
How To Install SQL Server 2014 Express Edition Updated: 2/4/2016 2016 Shelby Systems, Inc. All Rights Reserved Other brand and product names are trademarks or registered trademarks of the respective holders.
Paragon Recovery Media Builder
PARAGON Software GmbH Heinrich-von-Stephan-Str. 5c 79100 Freiburg, Germany Tel. +49 (0) 761 59018201 Fax +49 (0) 761 59018130 Internet www.paragon-software.com E-mail [email protected] Paragon
HP ProLiant Essentials Vulnerability and Patch Management Pack Release Notes
HP ProLiant Essentials Vulnerability and Patch Management Pack Release Notes Supported platforms... 2 What s new in version 2.1... 2 What s new in version 2.0.3... 2 What s new in version 2.0.2... 2 What
User Guide Software Version 2.1.0
Intel Solid State Drive Firmware Update Tool User Guide Software Version 2.1.0 Order Number: 322570-007US Intel disclaims all express and implied warranties, including without limitation, the implied warranties
Installation / Migration Guide for Windows 2000/2003 Servers
PSQL v9 SP1 (9.1) & Installation / Migration Guide for Windows 2000/2003 Servers Ebix, Inc. Corporate Headquarters Concourse Parkway, Suite 3200 Atlanta, GA 30328 USA Phone: 678-281-2020 Fax: 678-281-2019
Team Foundation Server 2012 Installation Guide
Team Foundation Server 2012 Installation Guide Page 1 of 143 Team Foundation Server 2012 Installation Guide Benjamin Day [email protected] v1.0.0 November 15, 2012 Team Foundation Server 2012 Installation
Exchange Server Backup and Restore
WHITEPAPER BackupAssist Version 6 www.backupassist.com Cortex I.T. 2001-2007 2 Contents 1. Introduction... 3 1.1 Overview... 3 1.2 Requirements... 3 1.3 Requirements for remote backup of Exchange 2007...
HP Mobile Remote Control (Select Models Only) User Guide
HP Mobile Remote Control (Select Models Only) User Guide Copyright 2008 Hewlett-Packard Development Company, L.P. Windows and Windows Vista are either trademarks or registered trademarks of Microsoft Corporation
Nexio Connectus with Nexio G-Scribe
Nexio Connectus with Nexio G-Scribe 2.1.2 3/20/2014 Edition: A 2.1.2 Publication Information 2014 Imagine Communications. Proprietary and Confidential. Imagine Communications considers this document and
Tutorial How to upgrade firmware on Phison S8 controller MyDigitalSSD using a Windows PE environment
Tutorial How to upgrade firmware on Phison S8 controller MyDigitalSSD using a Windows PE environment Version 2.0 This tutorial will walk you through how to create a bootable USB drive to enter into a WINPE
Microsoft Windows Server 2003 Compute Cluster Edition Installation Guide. For IBM Cluster 1350
Microsoft Windows Server 2003 Compute Cluster Edition Installation Guide For IBM Cluster 1350 Dan Ghidali IBM Systems and Technology Group 2 Table of Contents Introduction... 4 Windows Server 2003 Compute
Shearwater Research Dive Computer Software Manual
Shearwater Research Dive Computer Software Manual Revision 1.3 Table of Contents 1. Basic overview of components 2. O/S IrDA driver installation 2.1 USB IrDA installation for Windows XP Home/Pro editions
XConsole GUI setup communication manual September 2010.
XConsole GUI setup communication manual September 2010. XConsole is compatible with Microsoft XP, Vista and Windows 7. The software will also work if using Boot camp on a Mac. IMPORTANT NOTES: - Do NOT
UltraBac Documentation. UBDR Gold. Administrator Guide UBDR Gold v8.0
UltraBac Documentation UBDR Gold Bare Metal Disaster Recovery Administrator Guide UBDR Gold v8.0 UBDR Administrator Guide UBDR Gold v8.0 The software described in this guide is furnished under a license
FTP Server Configuration
FTP Server Configuration For HP customers who need to configure an IIS or FileZilla FTP server before using HP Device Manager Technical white paper 2 Copyright 2012 Hewlett-Packard Development Company,
Using HP Systems Insight Manager to achieve high availability for Microsoft Team Foundation Server
Using HP Systems Insight Manager to achieve high availability for Microsoft Team Foundation Server Executive summary... 2 Audience... 2 Architecture... 3 Prerequisite... 4 Deploying AT servers... 5 Configuring
SMTP PROXY SERVER INSTALLATION FOR HP QUICKPAGE
SMTP PROXY SERVER INSTALLATION FOR HP QUICKPAGE INTRODUCTION To ensure accurate billing, the HP QuickPage program requires collection of the metered information from the printers and multifunction products
Installation Guide. Your FedEx Ship Manager system number. Before you start
Installation Guide Your FedEx Ship Manager system number Installation Guide During registration, you receive a FedEx Ship Manager system number. Write the number here so you have it on hand whenever you
This user guide describes features that are common to most models. Some features may not be available on your computer.
RAID User Guide Copyright 2011 Hewlett-Packard Development Company, L.P. Intel is a trademark of Intel Corporation in the U.S. and other countries. Microsoft, Windows, and Windows Vista are U.S. registered
e-dpp 4.0.2 May 2013 Quick Installation Guide Microsoft Windows 2003 Server, XP, Vista, 7 Access Database
e-dpp 4.0.2 May 2013 Microsoft Windows 2003 Server, XP, Vista, 7 Access Database ELTECHS Engineering and Consulting Co., Ltd., Japan www.eltechs.co.jp Tel No. +81 (47) 490-1010 Fax No. +81 (47) 490-1011
Fiery E100 Color Server. Welcome
Fiery E100 Color Server Welcome 2011 Electronics For Imaging, Inc. The information in this publication is covered under Legal Notices for this product. 45098226 27 June 2011 WELCOME 3 WELCOME This Welcome
Data Lifeguard Tools. Software Manual
Data Lifeguard Tools Software Manual WD Data Lifeguard Tools User Manual Information furnished by WD is believed to be accurate and reliable; however, no responsibility is assumed by WD for its use nor
How to configure Failover Clustering for Hyper-V hosts on HP ProLiant c-class server blades with All-in-One SB600c storage blade
How to configure Failover Clustering for Hyper-V hosts on HP ProLiant c-class server blades with All-in-One SB600c storage blade Executive summary... 2 System requirements... 2 Hardware requirements...
Guidelines for using Microsoft System Center Virtual Machine Manager with HP StorageWorks Storage Mirroring
HP StorageWorks Guidelines for using Microsoft System Center Virtual Machine Manager with HP StorageWorks Storage Mirroring Application Note doc-number Part number: T2558-96337 First edition: June 2009
Installing Windows 95 Drivers and Utilities for the Cisco Aironet 340/350 Series Client Adapters
Installing Windows 95 Drivers and Utilities for the Cisco Aironet 340/350 Series Client Adapters Document ID: 12134 You need a valid Cisco.com account in order to download Cisco Aironet drivers, firmware,
SATA150 TX2PLUS, TX4 QUICK START GUIDE. Version 1.2
SATA150 TX2PLUS, TX4 QUICK START GUIDE Version 1.2 SATA150 TX2plus, TX4 Copyright 2002 Promise Technology, Inc. Copyright by Promise Technology, Inc. (Promise Technology). No part of this manual may be
ThinkServer RD550 and RD650 Operating System Installation Guide
ThinkServer RD550 and RD650 Operating System Installation Guide Note: Before using this information and the product it supports, be sure to read and understand the Read Me First and Safety, Warranty, and
VirtualXP Users Guide
VirtualXP Users Guide Contents Chapter 1: Introduction... 2 Chapter 2: Install and Uninstall VirtualXP... 3 2.1 System Requirement... 3 2.2 Installing VirtualXP... 3 2.3 Uninstalling VirtualXP... 3 Chapter
