The space saving solution.



Similar documents
IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

Industrial infrared heater IR For premises with large volumes and high ceilings

Brochure EX

Fan Convector Technical Specifications January 2006 Rev A

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

1. Geo Vertical 2. Geo Horizontal

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

Itho Products for Hot and Boiling water. product-

Installation, operation and maintenance manual TX 35A

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

ECOCIAT. Domestic hot water heat recovery unit

1. Description. 2. List of Accessories included A B C F G H

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Brochure EX

Drayton Digistat +2RF/+3RF

Operators manual Basic water heater

ELECTRIC CENTRAL HEATING FLOW BOILER

Technical data. Danfoss DHP-A

Decorative Metal Wiring Accessories in Assorted Plate Finishes

ELECTRIC I FIRES. CW036_Electric_brochure_art.indd 1

HERZ-Thermal Actuators

1. Taboe Sani 2. Taboe 3. Taboe Freestanding

SLIEVE - HORIZONTAL. Slieve featured in White RAL9016

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Invisidor STYLE Air Curtain

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Technical catalogue convectors POLAND 2012

Endless Hot Water 24/7

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

REDRING POWERSTREAM-ECO UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

S & P COIL PRODUCTS LTD SPC HOUSE, EVINGTON VALLEY ROAD, LEICESTER. LE5 5LU. Electrical layouts for EC Motors in Fan Convector units

Adjustable room thermostat for heating only or cooling only systems

NOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS

SF15K SF05KSS, SF10KSS

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

CHAPTER CONTENT PAGE. Hybrid: The perfect solution for all systems. Explanation of the - Heat Exchanger 4. Finishes 12

3Aftermarket Systems. Air Conditioners and Kombos Heater/Pressurizer System Matrix Aftermarket System Requirements...

INSTANTANEOUS GAS FIRED

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

The most comfortable air-conditioning systems for yachts and superyachts

new Twine & Pinch A tribute to the traditional column radiator Eyecatchers From design to art 2009 Ex

How To Buy A Designo Grille

Commercial Gas Furnace Upflow

DCS Input/Output Relay Card Series

Electric Rotary Actuator - On/Off or programmable control actuator

CADB and CADT-D / DI / DC Series

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

PROFESSIONAL AUDIO VISUAL. the ultimate in luxury, waterproof and in-wall televisions

Shower Handbook (Also covers 650 chrome variant)

Solar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS

Light Duty Commercial Electric Water Heater

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Morgue refrigeration unit

squrboxbox heat recovery squrboxbox I technical information

WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING:

INSTALLATION & USER INSTRUCTIONS

Local Dealer:

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

SERVER ROOM CABINET INSTALLATION CONCEPTS

RPV - RP - RA air handling units

Flexit Central Vacuum Cleaner

How To Design A Gas Dryer

Flexit Central Vacuum Cleaner

BB-18 Black Body High Vacuum System Technical Description

HEAVY DUTY STORAGE GAS

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move

We have been working in an ideal climate for thirty years.

KONRAD. Hybrid Fancoil Series

CRAC Precision climate control units for data centres

User's Instructions. Alpha HE CB25/33 and HE SY25

UDSA - UDSBD unit heater

Complete units. Complete underfloor box for one Modul 45 socket and two data connection sockets. Complete service outlets

Series 8146/5-V37 and Series 8150/5-V37

BROWACOM PRODUCTS. Our web-pages can be found from:

Solar hot water systems that give energy efficiency a whole new meaning

Electric Flow Boiler

Midland Combustion Electric Line Heaters with Integral Panels

HDA

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

PS1800 Centrifugal Pumping Systems

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

FIREDEX Conventional Fire Panels

Medical Lighting. XL4 Patient Light

8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient!

HL Series - Commercial Heaters Tankless Water Heating Solutions

SWIMMING POOL HEAT PUMP

LIGHTING FOR KITCHENS / UTILITY ROOMS / WORKSHOPS / KITCHEN CABINETS / GLASS CABINETS / FURNITURE

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

Installation Guide for Hive Active Heating

Heating Solutions Space and Water Heating

Transcription:

10 KICKSPACE KICKSPACE. Over 70% of people think that they would benefit from additional kitchen space (ICM Research 2012) Kitchen kindly supplied by Second Nature kitchens - www.sncollection.co.uk The space saving solution. A classic space saving solution. Clever by design, the KICKSPACE unit fits neatly within a unit plinth or floor cavity providing a fresh thinking, innovative heating solution. Where traditional radiators take up precious wall space and restrict design possibilities, the KICKSPACE heater allows freedom to tailor your home around your lifestyle. Central heating, electric and duo models available.

KICKSPACE 11 Before How KICKSPACE works. KICKSPACE works by drawing room air over the heated fins of the unit heat exchanger and projecting warm air back into the room. Controls are situated on the front grille, with the unit having a choice of heating fan speeds (winter setting) as well as a fan-only (summer setting) operation. After The kitchen is often where space is most at a premium and the KICKSPACE can deliver the most benefits but equally, the bathroom or hallway can be alternative applications. All versions are designed to be installed horizontally into recessed locations. They require an adequate supply of inlet air and the axis of the motor must remain horizontal.

12 KICKSPACE Hydronic KICKSPACE 500, 600 & 800. Our most popular range of KICKSPACE models, they fit neatly within kitchen plinths to save valuable space. The hydronic range connects to the central heating system like a radiator, but also requires an electrical connection to power the fan. KICKSPACE HYDRONIC. Available as a low voltage model for use in bathrooms KICKSPACE 600-12V. Perfect for bathrooms or areas of high humidity. The low voltage KICKSPACE still connects to a heating system, but comes with a transformer that will reduce the input voltage from 230V to 12V. Kitchens kindly supplied by Second Nature kitchens - www.sncollection.co.uk

KICKSPACE Duo & Electric 13 KICKSPACE DUO & ELECTRIC. KICKSPACE 500 Duo. The Duo model delivers the best of both worlds. Instant heat from the electrical element, and then, when the central heating is up to temperature, simply switch over to central heating mode. KICKSPACE 500E. 500 Duo This electric fan convector is ideal for homes that either do not have central heating, or where routing pipework to an area could be difficult. The electrical element provides instant heat. KICKSPACE 600E. 500E Another electrical fan convector, the 600E is able to provide larger outputs up to 3kW. Unlike the other products in the range, the 600E comes with a fixed grille and has the option of White, Brown or the popular Brushed Stainless Steel. 600E Brown 600E Brushed Stainless Steel 600E White

14 KICKSPACE Accessories KICKSPACE ACCESSORIES. KICKSPACE Grilles. The unit grilles can be customised to suit any room or décor with a variety of metallic and colour finish options. Painted grilles come in White (supplied), Brown and Black with metallic options in Brushed Stainless Steel, Chrome and Aluminium. KICKSPACE Thermostat. The building regulations part L (Conservation of fuel and power) recommends that every room should be thermostatically controlled. The KICKSPACE room thermostat will sense the room temperature and, if required, will activate the unit to provide additional heat. KICKSPACE Wall Switches. The remote wall switch can be customised to suit any room décor with a variety of metallic and colour finish options. Kitchen kindly supplied by Second Nature kitchens - www.sncollection.co.uk

KICKSPACE Technical Information 15 KICKSPACE Product Range Hydronic Product Range Flexible Hoses* Isolating Valves (15mm) Electric Cable Transformer Fan Only Option KICKSPACE 500 Supplied Supplied 2 metres KICKSPACE 600 Supplied Supplied 2 metres KICKSPACE 800 Supplied Supplied 2 metres Low Voltage Hydronic Product Range Flexible Hoses* Isolating Valves (15mm) Electric Cable Transformer Fan Only Option 1 metre KICKSPACE (low voltage fitted) Supplied Supplied Supplied 600-12V 1 metre (external from product) Yes Duo (Hydronic-Electric) Product Range Flexible Hoses* Isolating Valves (15mm) Electric Cable Transformer Fan Only Option KICKSPACE 500 Duo Supplied Supplied 2 metres Electric Product Range Flexible Hoses* Isolating Valves (15mm) Electric Cable Transformer Fan Only Option KICKSPACE 500E N/A N/A 2 metres KICKSPACE 600E N/A N/A 2 1 /2 metres *750mm x 10mm bore, EPDM hoses, sheathed in AISI 304 stainless steel braid. Please note that KICKSPACE 600E grilles are an integral part of the product and can not be changed. KICKSPACE Controls Hydronic (KICKSPACE 500, 600, 800, 600-12V) Fan Speed - Normal/off/boost. Summer/Winter - Fan only/heating option. Hydronic Electric (KICKSPACE 500 Duo) Summer/Off/Winter - Fan only/off/heating options. System Selector - Central heating/electric heating. Fan Speed - Normal/boost. Electric (KICKSPACE 500E) Summer/Off/Winter - Fan only/off/heating option. Power Selector - 1kW or 2kW. Fan Speed - Normal/boost. Electric (KICKSPACE 600E) Summer/Winter/Output.

16 KICKSPACE Technical Information KICKSPACE Performance Data Hydronic s It is preferable to select the model with an output capable of maintaining the calculated heat losses of the room when operating at normal speed. This will enable the boost fan speed and the higher temperature differences to be used to greater advantage for rapid warming of the room from cold in excessive conditions. When establishing the temperature difference, i.e. mean water to room temperature, allowance should be made for temperature drop in the system. It is the water temperature at the convector which dictates the output. Hydronic Heating Performance Data 500 600 800 Fan Speed Temperature Difference ( C) Heat Output (Watts) Heat Output (Btu/h) 20 30 40 50 60 20 30 40 50 60 Normal 393 566 733 896 1056 1340 1930 2501 3057 3603 Boost 447 683 923 1166 1412 1524 2331 3150 3980 4817 Normal 467 729 1000 1278 1562 1592 2486 3412 4361 5330 Boost 607 939 1279 1625 1977 2072 3203 4363 5545 6744 Normal 747 1077 1396 1707 2012 2550 3675 4763 5824 6864 Boost 845 1289 1738 2192 2649 2885 4397 5930 7478 9039 Heat outputs tested in accordance with BS 4856 Part 1. Low Voltage Hydronic Heating Performance Data 600-12V Fan Speed Temperature Difference ( C) Heat Output (Watts) Heat Output (Btu/h) 20 30 40 50 60 20 30 40 50 60 Normal 467 729 1000 1278 1562 1592 2486 3412 4361 5330 Boost 607 939 1279 1625 1977 2072 3203 4363 5545 6744 Heat outputs tested in accordance with BS 4856 Part 1. Duo (Hydronic/Electric) Heating Performance Data - Electric Mode The unit will operate on either fan speed to provide 1kW of heating. Duo (Hydronic/Electric) Heating Performance Data - Hydronic Mode 500 Duo Fan Speed Temperature Difference ( C) Heat Output (Watts) Heat Output (Btu/h) 20 30 40 50 60 20 30 40 50 60 Normal 273 447 636 835 1043 930 1527 2169 2849 3560 Boost 372 597 835 1083 1340 1269 2037 2849 3696 4571 Heat outputs tested in accordance with BS 4856 Part 1. Flow Rate: 340 ltr/h (75 gal/h). Approximate Hydraulic Resistance ltr/h Flow Rate Correction Factors: 455 ltr/h (100 gal/h) multiply output by 1.03. 227 ltr/h (50 gal/h) multiply output by 0.96. 113 ltr/h (25 gal/h) multiply output by 0.85. mm wg kpa 500 600 800 600-12V 500 Duo 500 600 800 600-12V 500 Duo 455 788 1046 911 1046 652 7.7 10.3 8.9 10.3 6.4 340 488 625 544 625 380 4.8 6.1 5.3 6.1 3.7 227 231 326 258 326 204 2.3 3.2 2.5 3.2 2.0 113 82 95 82 95 68 0.8 0.9 0.8 0.9 0.7

KICKSPACE Technical Information 17 KICKSPACE Performance Data (continued) Air Flow Air Flow (m 3 /h) Air Flow (ft 3 /h) Normal Boost Normal Boost 500 70 90 2471 3177 600 106 138 3742 4872 800 139 210 4908 7415 600-12V 106 138 3742 4872 500 Duo 70 90 2471 3117 Weight, Water Content and Motor Power Motor Power (W) Water Content (l) Unit Weight (kg) 500 25 0.26 4.3 600 40 0.30 5.0 800 40 0.34 5.5 600-12V 40 0.30 7.9* 500 Duo 25 0.26 4.5 * Includes transformer Sound Levels Sound Pressures at 2.5m (dba) Normal Boost 500 25.7 38.1 600 26.4 37.2 800 28.5 49.8 600-12V 29.4 39.0 500 Duo 25.7 38.1 Sound levels tested in accordance with EN 23741. Electric s Electric Heating Performance Data Heat Output (Watts) Low Medium High 500E 1000 N/A 2000 600E 1000 2000 3000 Weight Unit Weight (kg) 500E 3.0 600E 3.5 Air Flow Air Flow (m 3 /h) Air Flow (ft 3 /h) Low High Low High 500E 70 90 2471 3177 600E 210 N/A 7560 N/A Sound Levels Sound Pressures at 2.5m (dba) Low High 500E 27.2 40.2 600E 38.0 N/A Sound levels tested in accordance with EN 23741. KICKSPACE Remote Wall Switch (optional) KICKSPACE Remote Thermostat Available Finishes: White, Chrome, Brass, Brushed Stainless Steel. All remote wall switches are supplied with 3 metres of cable. All models are equipped to facilitate direct wiring. Suitable for uses with standard single gang surface or recessed mounting box (not supplied). The switch must only be used to operate a single KICKSPACE unit. For use on Hydronic and Hydronic-Electric (Duo) models only. Not suitable for Electric only models. N.B: When a remote wall switch is fitted, the fan speed control switch on the KICKSPACE facia grille becomes inoperable and must be disconnected. The remote room thermostat is supplied White as standard and is suitable for 500, 600 & 800 Hydronic models. KICKSPACE Grille Colour Options KICKSPACE models 500, 600, 800, 600-12V, 500 Duo and 500E are supplied with a White (RAL 9003) grille. All these models are also available in Brown (RAL 8017), Black (RAL 9011), Chrome, Brushed Stainless Steel and Aluminium. The 600E facia grille is an integral part of the product and can not be removed and is supplied with either a White or Brown grille.

18 KICKSPACE Technical Information KICKSPACE Electrical Data All KICKSPACE models require an electrical supply of 220-240V-50Hz. All models can be used in conjunction with a room thermostat, however it is essential that the thermostat used is capable of carrying the electrical load. Hydronic (KICKSPACE 500, 600 & 800) Supplied with 2 metres of cable (0.75mm²). Requires a supply fused at 3A. Low Voltage Hydronic (KICKSPACE 600-12V) Supplied with 2 metres of cable (0.75mm²). Requires a supply fused at 3A. N.B: Low voltage models comply with BS 7671 section 601 (IEE Safety Extra Low Voltage wiring regulations for bathrooms). The transformer complies with BS 3535. Where a remote switch or thermostat is used, the line voltage to both is 12 volts maximum. Hydronic Electric (KICKSPACE 500 Duo) Supplied with 2 metres of cable (0.75mm²). Requires a supply fused at 5A. Electric (KICKSPACE 500E & 600E) 500E supplied with 2 metres of cable (1.0mm²). Requires a supply fused at 10A. 600E supplied with 2½ metres of cable (1.0mm²). Requires a supply fused at 13A. KICKSPACE Dimensions KICKSPACE 500 KICKSPACE 600 KICKSPACE 800 54 24 12 Cable Entries 67 93 54 Cable Entries 93 67 24 12 54 Cable Entries 93 67 24 12 82 82 82 36 36 36 309 Cable Entry 25 309 Cable Entry 25 309 Cable Entry 25 129 129 129 322 376 447 496 5 550 603 KICKSPACE 500 Duo KICKSPACE 600-12V 15 54 15 Cable entries 70 93 54 Cable Entries 93 67 24 12 56 28 82 36 318 309 Cable Entry Cable Entry 159.5 142 177 321 376 496 550 N.B: Add 4.5mm to the chassis height of the above models to allow for rubber mountings and screws. 25 129

KICKSPACE Technical Information 19 KICKSPACE Dimensions (continued) KICKSPACE 500E KICKSPACE 600E Cable entries 93 88 120 360 120 203 177 225 175 Cable entry 321 100 496 600 N.B: KICKSPACE 500E: Add 4.5mm to the chassis height of the above models to allow for rubber mountings and screws. KICKSPACE Kickboard Dimensions Option A (Excluding 500E) Dimensions of opening to be cut in Kickboard - KICKSPACE 500, 600, 600-12V, 800, 500 Duo, 500E, 600E Option B (Excluding 600E) Dimensions (mm) A B C 500, 500 Duo, 500E 466 93 17 600, 600-12V 520 93 17 800 573 93 17 600E 540 88 N/A