Eastman plasticizers. Bulk storage guidelines. Storage equipment. Tank components and materials. Piping. Pumps. Valves. Gaskets



Similar documents
PBX Series Quick Fit Connector Bimetallic Steam Traps

OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES

Western Plant Health Association DOT MC 330 & 331 NH3 Cargo Tank Inspection Checklist Form

IMPORTANT SAFETY NOTICE

SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN

UNIVERSITY OF WISCONSIN MADISON

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

Freedom to Create In-Store Fixtures and Point-of-Purchase Displays

Air Eliminators and Combination Air Eliminators Strainers

Waste Oil Collection / Storage

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

Chemical Handling : Bulk Liquid Chemical Unloading. Northern Michigan Wastewater Operators Seminar September 23, 2008

IAC 7/2/08 Agriculture and Land Stewardship[21] Ch 44, p.1

15GAL STEEL OIL DRAIN WITH 110V PUMP

University of Tennessee Safety Guidelines

Float and Thermostatic Traps Series H, C and X

Cooling system components, removing and installing

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

Assembly overview - fuel tank

Cooling system components, removing and installing

Quik Lining Systems Heater Owners Guide

Facility Support Services

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

ENGINE COOLING SYSTEM

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Overview. Eastman Aviation Solutions academy. excellence through training.

OREGON FIRE CODE Interpretations and Technical Advisories

Oil and Coolant Circulating Heating System. Model - OCSM

FUEL SYSTEMS OUR PARTS PUT YOU IN THE PASSING LANE. Protect your fuel system. velvac.com

Inspections Standard Operating Procedure 5 Aboveground Storage Tanks

Energy Saving Fact Sheet Boilers

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

Installation, Maintenance, & Repair Series 4000B/LF4000B

CHEMICAL CLEANING UNIT Product number:

Pressure Vessels (Air Compressors) and LPG Tanks

Grade Level Spill Containment Manholes

Intermodal Containers Presented by Bill Hand Training Coordinator Hazardous Materials Response Team Harris County, Texas

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

BP WIND ENERGY POLICIES AND PROCEDURES

TANKER - SHORE SAFETY CHECK-LIST

Stilling Well Recommendations

James M. Pleasants Company

HYDRAULIC TABLE CART 500-LB.

Ethanol Vehicle and Infrastructure Codes and Standards Citations

Waste Oil Handling, Spill Containment & Lighting

NFPA31FuelOilPiping 1 Revised

Compressed Gas Cylinder Program

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

VOYAGER 570G. 744A Sprayer Control

FLASH TANK ECONOMIZER PRODUCT GUIDE

Voltmaster Trash Pumps Model TSP2, TSP3 and TSP4

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

Operation & Maintenance Manual

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250 Single Wheel 4WD Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

Flushing and Cleaning the A/C System

CODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping

Boiler & Pressure Vessel Inspection discrepancies and failures

HYDRAULIC LIFT TABLE CART 2200-LB.

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

MODEL G300 BRAKE BLEEDER


COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS NOT FOR OXYGEN OR OTHER OXIDIZING GASES

Guidelines for Use and Handling of HFO-1234yf

Below Grade Spill Containment Manholes Gallon Gallon Gallon. Installation Instructions

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks

Compressed Gas Cylinder Storage and Handling Guide

MAGB HEALTH, SAFETY AND ENVIRONMENT GROUP POLLUTION INCIDENT RESPONSE PLAN

Installation of Underground LP-Gas Systems

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

Storage. Drum Storage

ALLEGANY WIND POWER PROJECT CONSTRUCTION SPILL PREVENTION PLAN

Outdoor Storage of Raw Materials SC-33

The First Line of Safety

BELZONA KNOW-HOW VALVES, PIPES AND FITTINGS BELZONA VPF SYSTEM SELECTOR BELZONA KNOW-HOW FOR VALVES, PIPES AND FITTINGS

Section 20 TABLE OF CONTENTS Pressurized Equipment and Systems. 20.A General B Compressed Air and Gas Systems

VAD. Variable Area Desuperheaters

AIR LINE VALVES AND GAUGES

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

Standard Hydraulic Piping Flushing Procedure

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100

VAD Variable Area Desuperheaters

HYDRAULIC TABLE CART

A Job Safety Execution Plan is required. mixtures of the above called, natural gas liquids (NGL's) refined products and their components

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL

Midwest Industrial Tanks

List of Frequently Utilized Storage Tank Standards and Practices

Installation, Operation and Maintenance Manual for Pilot Operated Valves

Steam System Best Practices Condensate System Piping

Spill Kits and Incidental Spill Response

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:

ROUGHNECK II Pumpless Drain

How To Make A Pressure Relief Valve

Transcription:

Eastman plasticizers Bulk storage guidelines This publication contains general information on the bulk storage of Eastman plasticizers, including guidelines for tank components and materials, as well as unloading tank cars and tank trucks. Eastman assumes no liability or responsibility for any use or misuse, or the results of such use or misuse, of any information, procedure, conclusion, opinion, product, or process provided in this publication. Users of this information must be guided by the specific requirements of their company, personnel, technology, and manufacturing operations. All persons involved in using, handling, storing, transporting, and disposing of Eastman products have an independent obligation to ensure that their actions are in compliance with current federal, state, and local laws and regulations and should consult with their technical and regulatory experts concerning such matters. For specific health and safety information, users of Eastman products should thoroughly review the pertinent Safety Data Sheets (SDS). Storage equipment Tank components, construction materials, and facilities for tank car and tank truck handling of these materials are discussed in this publication. See Figure 1 for an example of a typical storage tank for Eastman plasticizers. For the location, fabrication, installation, inspection, and testing of plasticizer storage tanks, the designer should refer to appropriate standards including: ASME Boiler Pressure Vessel Code, Section VIII, Division I NFPA Standard No. 30 National Fire Codes, Volume 1 API No. 620 Rules for Design and Construction of Large, Welded, Low-Pressure Storage Tanks Tank components and materials Stainless steel, carbon steel, or 5454 aluminum is suggested for tank construction to store Eastman monomeric and polymeric plasticizers. When using such materials for tank construction, a coating between the tank and the foundation may be necessary to reduce corrosion of the tank bottom. Piping The piping used for transferring plasticizer into and away from the tank can be steel except where corrosion or rust contamination is a concern, in which case stainless steel or aluminum can be used. Where sections of piping can be isolated between two closed valves, provisions for pressure relief should be in place, as plasticizers will expand on heating. Pumps For plasticizer transfer, centrifugal or positive-displacement pumps are suggested, using similar construction materials as with the associated piping. The pumps should have mechanical seals instead of packing glands. Careful attention should be given to pump selection when suction lift is needed. Valves Metal plug valves with PTFE (polytetrafluoroethylene) sleeves or ball valves with PTFE seats, seals, and packing should be considered. The choice of metal should be guided by the same considerations as for piping. Gaskets Gaskets made of PTFE or similar materials should be considered for use with Eastman plasticizers. Proper application of torque control or other bolt tensioning practices should be used to ensure a leak-free, reliable seal. API No. 650 Welded Steel Tanks for Oil Storage PIP INEG1000 Insulation Design and Type Codes

Vents Assuming federal, state, and local regulations permit it, tank vents may be open to the atmosphere and turned downward to prevent entry of rain, dust, etc. However, it is recommended that plasticizer storage tanks be provided with a blanket of inert gas or nitrogen and equipped with a pressure/vacuum conservation vent valve. The blanket generally is not required for fire prevention, but it will help prevent contamination of the product. Tank fill line/well pipe To inhibit the accumulation of static charges, it is suggested that the tank fill line/well pipe extend to within 2 to 3 in. (5 to 8 cm) of the bottom of the tank. The construction standard used to design the tank will determine the maximum fill level. Heating systems for plasticizer storage Outdoor tanks may be insulated with a blanket of fiberglass or similar material approximately 2 in. (5 cm) thick. The following suggested heating systems can be adapted to individual outdoor tanks for plasticizer storage. The heating system should be designed to maintain the temperature designated and to prevent overheating. Electrically heated system This type of system consists of electrical heating pads attached to the outside surface of the storage tank as shown in Figure 2. A temperature controller is used to maintain the temperature between 60 and 120 F (15 to 50 C), depending on which plasticizer is being stored. The piping for this system should be electrically heat traced. Special care should be taken to ensure aluminum tanks are not overheated as structural damage may occur. Figure 1 Storage tank base detail Measuring nozzle Pressure/vacuum relief Nitrogen or inert gas Vent to atmosphere or conservation vent Liquid level gauge or level transmitter Tank holddown lug 1 /2-in. (13-mm) antisiphon hole manhole Fill line Fill and recirculate line To process From tank car or tank trailer Sloped bottom Pump Ground cable 2

Figure 2 Heating by electrical pads Insulate entire tank Electrical heating pads Storage tank Thermowell Plasticizer temperature controller Steam-heated system This method uses a pump to circulate the plasticizer through a heat exchanger. The exchanger is heated by low-pressure steam, which is controlled by a temperature controller as shown in Figure 3. The pump used for circulation can also be used for transferring plasticizer to feed tanks. To prevent overheating and degradation of product inside the heat exchanger, this system should be activated only when the product temperature must be increased and shut down when no heating is required. The piping for this system should be sandwich heat-traced with low-pressure steam. Sandwich heat tracing involves inserting a pad or full layer of insulation between the steam tubing and the pipe to prevent hot spots and overheating. Additional layers of insulation can be installed around the tubing/pipe assembly. Low-pressure steam is used to further reduce the risk of overheating the product, compared to the use of higher-pressure steam. Low pressure in this case generally includes steam below 100 psia (7 bar), though pressure below 30 psia (2 bar) is better if available. Figure 3 Heating by heat exchanger Insulate entire tank To process Storage tank Steam Plasticizer temperature controller To condensate recovery Heat exchanger Capitalize pump Piping sandwich heattraced and insulated 3

Repurposed tanks If a tank used previously in another service is being repurposed to store Eastman plasticizer, it should be thoroughly cleaned and decontaminated. A tank that is improperly cleaned can contaminate the plasticizer and cause undesirable issues. Bulk delivery and unloading The following pages outline suggested procedures for unloading tank cars and tank trailers and are general guidelines only. The comprehensive Department of Transportation (DOT) regulations should be consulted and observed. It is the user s responsibility to comply with all laws and regulations governing the unloading of tank cars and tank trucks. Eastman plasticizers are shipped in steel tank cars (rail) and stainless steel tank trailers (road). The usual tank car size is 20,000 gallons (76,000 liters). Tank trailer sizes vary upward from 4,000 to 6,000 gallons (15,000 to 22,700 liters). The unloading area should be provided with an emergency containment and drainage system to direct the contents of the vehicle to a safe location other than the sanitary sewer or surface waters if a spill occurs. Also, a vapor return line can be used to comply with EPA venting requirements. Tank car unloading Unloading operations must be performed only by personnel properly trained in unloading hazardous materials in accordance with 49 CFR 174.67. It is recommended that tank cars be unloaded from the top, making it easier to shut off the flow if a transfer line leaks or ruptures. This helps reduce the volume of an accidental discharge. Figures 4 through 6 show several unloading arrangements for tank cars. In Figures 4 and 5, the unloading lines are connected to the fixed well line in the tank car. This arrangement provides a nearly closed system and minimizes personnel exposure. The unloading method shown in Figure 6 involves lowering a well pipe through the open manway of the car. For top unloading, an access platform is suggested. Figure 4 Tank car top unloading/fixed piping with swivel joints Steel tank car Swivel joint Flexible metal hose Flanged ball valves (on car) 3 in. (76 mm) and 2 in. (51 mm) for 20,000-gal car, 2 in. (51 mm) and 1 in. (25 mm) for 10,000-gal car Open vent valve to atmosphere or to vapor return line Swivel joint Safety warning sign Wheel chocks Fixed well line in car To storage tank Self-priming centrifugal or positive-displacement pump 4

Figure 5 Tank car top unloading/flexible hose with flanged elbow Steel tank car Flanged ball valves (on car) 3 in. (76 mm) and 2 in. (51 mm) for 20,000-gal car, 2 in. (51 mm) and 1 in. (25 mm) for 10,000-gal car Open vent valve to atmosphere or to vapor return line Safety warning sign Wheel chocks Fixed well line in car To storage tank Self-priming centrifugal or positive-displacement pump Flexible metal hose Figure 6 Tank car top unloading/removable well pipe with swivel joints Steel tank car Swivel joint Safety warning sign Swivel joint Manway Wheel chocks Removable well pipe To storage tank Self-priming centrifugal or positive-displacement pump 5

Typical unloading procedure for tank cars 1. Read storage tank liquid level gauge, record reading, convert inventory to appropriate units, and make certain that tank will accept contents of the tank car. 2. Stop the tank car at unloading station and set hand brake. Apply chocks to wheels to help prevent movement of car in either direction. Position warning signs on each side of car along rails and, if necessary, attach derailing devices to rails or lock switch to spur track involved. 3. Attach a ground wire to tank car. 4. Read and record tank car number, numbers on metal tape seals located at various openings on car, and product identification tags on manhole and bottom outlet. If these do not agree with information in shipping papers, check with the shipper before unloading. 5. Depending on type of unloading facilities, connect a flexible stainless steel or chemical rubber hose to outlet valve on car or lower well pipe through manhole. 6. Make certain the car is vented. For top unloading through the tank car s well line, open the smaller ball valve next to unloading line. For bottom unloading, open the manway cover on tank car. 7. Open all valves in transfer line between the tank car and the bulk storage tank. Start the pump and immediately check transfer lines for leaks. 8. Check the liquid level gauge on storage tanks to ensure liquid is being transferred. 9. When the tank car is empty, stop the pump and close valves on car. Close valves in transfer line. 10. Disconnect flexible hose or raise well pipes. Ensure the flexible hose is empty and not pressurized before disconnecting and draining into proper catch containers so that no product is lost onto the ground. Collect the drained material for proper waste disposal. Return any valves or connections on the rail car to their original condition as required by DOT regulations. Remove chocks, warning signs, derails, and switch locks. 11. Record storage tank liquid levels. Tank trailer unloading A cargo tank must be attended by a qualified personnel at all times during unloading in accordance with 49 CFR 177.834(i). The tank trailer unloading diagram (Figure 7) shows the liquid being unloaded through a stationary pump. Alternatively, a pump on the tractor can be used to transfer the liquid from the trailer to the storage tank. Figure 7 Tank trailer unloading/stationary pump Stainless steel tank trailer Chocks To storage tank Flexible hose (on trailer) Unloading pump 3-in. (76-mm) female quickconnect fitting on pump outlet STOP 6

Typical unloading procedure for tank trailers 1. Read the storage tank liquid level gauge, record reading, convert inventory to appropriate units, and make certain that the tank will accept contents of the tank trailer. 2. Position the tank trailer at the unloading station and set hand brake. Apply chocks to trailer wheels to help prevent movement in either direction. Position warning signs. 3. Attach a ground wire to the tank truck. 4. Read and record the tank trailer number, numbers on seals located on various openings on trailer, and product identification tags on manhole and bottom outlet. If these do not agree with the information on shipping papers, check with the shipper before unloading. 5. Connect a flexible stainless steel or chemical rubber hose to the tank trailer outlet and to quick-connect fitting on inlet of the stationary pump (Figure 7) or to the inlet of pump on the trailer. If a trailer pump is used, connect a second flexible hose from the trailer pump outlet to a fitting on storage tank fill line. 6. Make certain flexible hose connections are connected correctly. Open valves in line between the trailer and storage tank. 7. Open the trailer manual outlet valve and hydraulic outlet valve. Start the pump. Safety precautions Safety information A Safety Data Sheet (SDS) providing toxicity information, physical and chemical data, and spill and emergency response information has been provided for each Eastman plasticizer. The user should review this publication before handling, storing, or using any Eastman plasticizer. Copies are available at www.eastman.com or through your Eastman representative. The information in this publication, along with the SDS, needs to be reviewed and understood to help ensure the safe handling of Eastman plasticizers. It is the customer s responsibility to direct and control unloading of any chemicals or materials into or from bulk storage and handling facilities. Personal protective equipment Personal protective equipment (PPE) such as gloves, goggles, face shields, boots, and aprons appropriate for the chemical being handled should be specified, readily available, and worn by persons involved in the storage operation. Materials stored or handled at temperatures above 50 C (122 F) may present a thermal burn hazard and require appropriate protective wear. It is recommended that customers evaluate their handling and use procedures and select PPE appropriate to their needs. Consult the SDS for recommended practices and hazards. 8. Check transfer lines for leaks. Check the storage tank liquid level gauge to ensure liquid is being transferred. 9. When the tank trailer is empty, stop pumping and close the hydraulic outlet valve and manual valve on the trailer. Close valves in the transfer line. For more information on the handling of Eastman plasticizers, see publication L-275 or contact your Eastman representative. 10. Before disconnecting hoses, be sure they are empty and not pressurized. Drain hoses into proper catch containers, ensuring no product is lost onto the ground. Collect the drained material for proper waste disposal. 11. Remove chocks from the trailer wheels. 12. Record the storage tank liquid level. 7

Eastman Chemical Company Corporate Headquarters P.O. Box 431 Kingsport, TN 37662-5280 U.S.A. Telephone: U.S.A. and Canada, 800-EASTMAN (800-327-8626) Other Locations, (1) 423-229-2000 Fax: (1) 423-229-1193 Eastman Chemical Latin America 9155 South Dadeland Blvd. Suite 1116 Miami, FL 33156 U.S.A. Telephone: (1) 305-671-2800 Fax: (1) 305-671-2805 Eastman Chemical B.V. Fascinatio Boulevard 602-614 2909 VA Capelle aan den IJssel The Netherlands Telephone: (31) 10 2402 111 Fax: (31) 10 2402 100 Eastman (Shanghai) Chemical Commercial Company, Ltd. Building C, No. 399 Shengxia Road, Pudong New District 201210, Shanghai, P.R. China Telephone: (86) 21 6120-8700 Fax: (86) 21 5027-9229 Eastman Chemical Japan Ltd. MetLife Aoyama Building 5F 2-11-16 Minami Aoyama Minato-ku, Tokyo 107-0062 Japan Telephone: (81) 3-3475-9510 Fax: (81) 3-3475-9515 Eastman Chemical Asia Pacific Pte. Ltd. 9 North Buona Vista Drive #05-01 The Metropolis Tower 1 Singapore 138588 Telephone: (65) 6831-3100 Fax: (65) 6732-4930 www.eastman.com Although the information and recommendations set forth herein are presented in good faith, Eastman Chemical Company makes no representations or warranties as to the completeness or accuracy thereof. You must make your own determination of their suitability and completeness for your own use, for the protection of the environment, and for the health and safety of your employees and purchasers of your products. Nothing contained herein is to be construed as a recommendation to use any product, process, equipment, or formulation in conflict with any patent, and we make no representations or warranties, express or implied, that the use thereof will not infringe any patent. NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR OF ANY OTHER NATURE ARE MADE HEREUNDER WITH RESPECT TO INFORMATION OR THE PRODUCT TO WHICH INFORMATION REFERS AND NOTHING HEREIN WAIVES ANY OF THE SELLER S CONDITIONS OF SALE. Safety Data Sheets providing safety precautions that should be observed when handling and storing our products are available online or by request. You should obtain and review available material safety information before handling our products. If any materials mentioned are not our products, appropriate industrial hygiene and other safety precautions recommended by their manufacturers should be observed. 2014 Eastman Chemical Company. Eastman and The results of insight are trademarks of Eastman Chemical Company. L-276 6/14