Proportional reducer D386 ATEX Classification according Article 3.3 of European Directive n 97/23/CE from 29/05/1997 Classification according group II, category 2 and temperature class T4 of ATEX Directive 94/9/CE du 23/03/1994 Marked Main material Threaded ports Internal diameter II 2 G - EEx d IIC T4 ou T5 - LCIE 04 ATEX 6111 (5 mn for T4, 20 mn for T5) Ø 3 mm Valve insert / seat materials Stainless steel (I) / Peek (P) Inlet / outlet integrated filter 25 µm Max inlet pressure Outlet pressures calibration ranges Internal leak tight : Min 10-3 mbar.l/s in Helium (valve / seat) External leak tight : Min 10-4 mbar.l/s in Helium Air flow by bar absolute of outlet pressure in sonic phase (P. inlet > 2 x P. outlet) : - Outlet port 1/4" : 2,8 Nm3/h 420 bar (S) 0 to 20 bar 82 0 to 40 bar 83 0 to 60 bar 87 0 to 100 bar 43 0 to 250 bar 59 0 to 400 bar 85 Main configurations: 3 ways regulator Power supply 24 VCC / 2 A Input and output 0 10 V CMS card Integrated outlet pressure sensor 3 ways regulator Power supply 24 VCC / 2 A Input and output 4 20 ma CMS card Integrated outlet pressure sensor For a flow value in subsonic phase (P. inlet <= 2 x P. outlet), please contact us. Flow correction in Nm3/h report to Air value : ρ air Q gaz = Q air ρ gaz (ρ = volume mass) Advised fittings: T1847 (1) Inlet pressure Weight : 4,8 kg (2) Outlet pressure (3) Vent 1812 1813 Complementary characteristics: Hysteresis et reliability: < 1% of the max outlet pressure range Functioning temperature: - 20 C / + 50 C Response delay: < 50 ms Flow and KV values are given as a rough guide. IMF reserves the right to modify its manufacturing without advance notice. E-mail : contact@imi-precision.fr Web: www.imf-fluidcontrol. 2015 Edition
Proportional reducer D386 ATEX Male base connector View from weld side (1) (3) (2) (1) Inlet pressure (2) Outlet pressure (3) Vent Confidential Power supply +24 Vdc Earth power supply Input signal 4 20 ma ou 0 10 V Output signal 4 20 ma ou 0 10 V Earth output signal Earth input signal
General summary Product summary Codification O-ring and diaphragm material Back Close? Codification IMF components (1) The main material means the material of the envelope (external parts) of the component (the body) Generally for a component made of stainless steel, all parts in contact with the media are made of stainless steel and others are made of Nickel plated brass. (2) The function defined the number of ports, the number of positions and the position of the valve (opened or closed) when the valve is not energized. (3) O-ring and diaphragms materials, and cleaning operating procedures are defined into the page O-ring and diaphragms materials. (4) The options define the complementary characteristics: - the "X" digits definition which are not mentioned in the table. - complementary definition of previous digits of the code. The option 1000 called "STANDARD VERSION" defines the basic version of IMF components (without any particularity). Example of codification: D 386 L S 85 N I P 1000 D = Reducer (PCV ) 386 = Type or family L = Brass construction S = Max inlet pressure (MWP) 420 b 85 = Outlet range 0 to 400 bar (as per data sheet) N = O Rings type = Nitrile O-ring / Cleaning procedure P902 I = SS 316L valve insert P = PEEK seat 1000 = Standard version (balanced valve & self venting )
General summary Reducers summary Codification O-ring and diaphragm material Back Close? Proportional reducer D366 Classification according Article 3.3 of European Directive n 97/23/CE from 29/05/1997 Main material Threaded ports *** Internal diameter Valve insert material Seat material Max inlet pressure Ø 4 mm Ntrile (N) Viton (V) EPR (E) ** 100 bar (G) ** EPR = Ethylene propylene *** IMF also propose upon request a version with base fitting Internal leak tight : Min 10-3 mbar.l/s in Helium (valve / seat) External leak tight : Min 10-4 mbar.l/s in Helium Air flow by bar absolute of outlet pressure in sonic phase (P. inlet > 2 x P. outlet) : - Outlet port 1/4" : 2,8 Nm3/h For a flow value in subsonic phase (P. inlet <= 2 x P. outlet), please contact us. Flow correction in Nm3/h report to Air value : Outlet pressures calibration ranges 0 to 1 bar 89 0 to 10 bar 88 Q gaz = Q air ρ air ρ gaz (ρ = volume mass) (1) Inlet pressure (2) Outlet pressure (3) - Vent 0 to 20 bar 82 0 to 40 bar 83 0 to 60 bar 87 0 to 100 bar 86 Complementary characteristics Advised fittings: T1847 Weight : 1,5 kg Main options : 121,5 29,5 (2) (3) (1) 42,5 Hysteresis et reliability: < 1% of the max outlet pressure range Functioning temperature: - 20 C / + 50 C Response delay: < 50 ms Consomption maxi: < 1 A 52 16,5 35 54 131 Flow and KV values are given as a rough guide. IMF reserves the right to modify its manufacturing without advance notice.
General summary Reducers summary Codification O-ring and diaphragm material Technical data sheet Close? Proportional reducer D366 Male base connector View from weld side Power supply +24 Vdc Output signal 4 20 ma ou 0 10 V Earth power supply Earth output signal Input signal 4 20 ma ou 0 10 V Earth input signal 10 35,5 30 Fixing by 3 wholes Ø 4,2