USB Smart Power Sensor

Similar documents
USB Smart Power Sensor

USB Smart Power Sensor

Wideband USB Synthesized Signal Generator. Dynamic range 70 db, output power from -60dBm to +10dBm in 0.25dB steps

RC-1SP4T-A18. Key Features. Mini-Circuits P.O. Box 35166, Brooklyn, NY (718)

RCDAT The Big Deal

RUDAT Key Features. Mini-Circuits P.O. Box , Brooklyn, NY (718)

USB I/O CONTROL BOX 8 relays, 8 digital I/O lines and 8 HV inputs

Ideal for high dynamic range measurements from compression to noise floor

iva Cable & Antenna Analyzer

iva Cable & Antenna Analyzer

Impedance 50 (75 connectors via adapters)

Monolithic Amplifier PMA2-43LN+ Ultra Low Noise, High IP3. 50Ω 1.1 to 4.0 GHz. The Big Deal

NI USB-5681 RF Power Meter Specifications

Power Sensor/Meter with USB Interface Connect Directly to a PC

US-Key New generation of High performances Ultrasonic device

PL-2303 (Chip Rev H, HX, X) USB to Serial Adapter Windows Driver Installer Manual

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

QuickSpecs. Model. HP USB HD 720p v2 Business Webcam. Overview

Broadband covering primary wireless communications bands: Cellular, PCS, LTE, WiMAX

One Port Network Analyzer

DSA800 Series Spectrum Analyzer

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

OMNIYIG. .5 TO 2 GHz, 1 TO 4 GHz, 6 to 18 GHz Thin Film YIG-TUNED OSCILLATORS OUTLINE DIMESIONS MOUNTING SURFACE GND +15V + TUNE - HTR HTR

CellAdvisor. JD725A Dual-Port Cable and Antenna Analyzer

Field Calibration Software

Micro HDMI to VGA with Audio Adapter. Quick Installation Guide. Introduction. Key Features and Benefits. System Requirements.

Agilent 8753ET/8753ES Network Analyzers

Pen Drive 2.0 Specification

How To Use A Sound Card With A Subsonic Sound Card

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Broadband covering primary wireless communications bands: Cellular, PCS, LTE, WiMAX

Signal and Tracking Generator

The Universal DAQ Device. Connect and measure immediately!

Symbol Parameters Units Frequency Min. Typ. Max. 850 MHz

Name Description P/N. Programmer Programmer with calibration function SDD-AAPNP. Parameter Min. Typ. Max. Notes. (Vo+ - Vo-) - Voltage

1. SAFETY INFORMATION

Signal Conditioning Amplifier System

USB-AD16f Data acquisition system (USB)

USB to RS-422/485 Serial Adapter (ID-SC0911-S1/SC0A11-S1) User s Manual

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

USB-500 Series Low-Cost Data Loggers and Accessories

USB-Blaster Download Cable User Guide

SuperSpeed USB 7-Port Hub Quick Installation Guide

R&S ZCxxx Millimeter-Wave Converters Specifications

US-SPI New generation of High performances Ultrasonic device

Universal Form-factor. Wi Fi Troubleshooting Made Easy

Point of view HDMI Smart TV dongle Mini RF Keyboard

Transmitter Interface Program

Multi-Range Programmable DC Power Supplies 9115 Series

MADRIX NEO Quick Start Guide & User Manual

Measuring static magnetic fields

Temperature Datalogger Users Manual

Parameter Min. Typ. Max. Units. Frequency Range GHz. Minimum Insertion Loss db. Dynamic 38 GHz 26 db

Inserting the SIM card in the MobiGater device. Connecting the MobiGater Device

PicoScope 6000A/B Series

Understanding Mixers Terms Defined, and Measuring Performance

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Installing the Gerber P2C Plotter USB Driver

ELAD FDM-S1 USER MANUAL. Ver. 1.01

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

USB Port Hub Quick Installation Guide

USB DRIVER INSTALLATION GUIDE

Product Specifications

RFSPACE CLOUD-IQ #CONNECTED SOFTWARE DEFINED RADIO

Current Monitoring Kit

RF and Microwave Power Sensors/Meters Tektronix PSM3000, PSM4000, and PSM5000 Series Data Sheet

Typical Performance 1. IS-95C ACPR dbm WCDMA ACLR dbm

ViewLinker USB 2.0 Graphics Adapter

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

User's Guide. Integrating Sound Level Datalogger. Model Introduction

PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector

User Guide USB, RS232 & Ethernet Programable Attenuators

Model SL355 Noise Dosimeter/Datalogger

USB-AD14f Data Acquisition System (USB)

SB-2000 USB Radio Interface Operating Manual CG Antenna Co. Ltd.

Project Documentation EKTSDG Target Simulator Doppler Generator

USER GUIDE WIRELESS USB TO AUDIO KIT. Model: 29594

USB 3.0 to HDMI External Multi Monitor Graphics Adapter with 3-Port USB Hub HDMI and USB 3.0 Mini Dock 1920x1200 / 1080p

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB Plus+ RFID Reader Setup Guide

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Models HP HDMI to VGA Adapter HP EliteFolio Ethernet & VGA Adapter New! HP HDMI to DVI Adapter New! HP DisplayPort to HDMI 1.4 Adapter New!

Pano Device. Data Sheet. How It Works: Key Benefits:

KS732 Family. Rev KS732. 1/3 CCD Color USB Camera

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet

VCC1,2. H/L Lin. Bias, Enable, Detector Circuits

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

SEE2 UV150 QUICK INSTALL GUIDE

ST800K-U Optical Power Meter. User Manual V1.0

DC Electronic Loads 8500 series

FREJA 300 Relay Testing System

NEW. EVEN MORE data acquisition and test stand automation

Multi-Profile CMOS Infrared Network Camera

Agilent Test Solutions for Multiport and Balanced Devices

Compact EGC Amplifier Model 93251

DRM compatible RF Tuner Unit DRT1

Embest DSO2300 USB Oscilloscope

Transcription:

50Ω -30 dbm to +20 dbm, 9 khz to 4000 MHz The Big Deal Low cost USB HID device compatible with 32/64 Bit operating systems Includes Measurement Application GUI (Graphical User Interface) software with an API-DLL com object High speed measurement capability CASE STYLE: JL1504 Installation CD Product Overview The Mini-Circuits Smart Power Sensor is a pocket-sized, 4.89 x 1.74 x 0.95, precision test USB HID device (no driver installation required) that turns a Windows or Linux PC into a power meter. All specifications provided in the data sheet apply to continuous wave (CW) signals. Each unit is shipped with our N-to-SMA adapter and a quick-locking USB cable for reliable connectivity. Native software and detailed user guides are provided on the included CD, or can be downloaded from minicircuits.com anywhere an internet connection is available, providing a full range of data analysis options. Key Features Feature USB HID (Human Interface Device) GUI Measurement Application Software built-in Advantages Plug-and-Play (no need to install driver for the device). Enables the user to perform measurements on RF components such as Couplers, Filters, Amplifiers etc. and displays numerical data and graphs. 32/64 Bit operating systems Compatible with Windows and Linux 1 operating systems. No calibration required before taking measurement The does not require any reference signal for calibration. 1 Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Linux is a registered trademark of Linus Torvalds. Neither Mini-Circuits nor the Mini-Circuits PWR-series smart power sensors are affiliated with or endorsed by the owners of the above referenced trademarks Mini-Circuits and the Mini-Circuits logo are registered trademarks of Scientific Components Corporation. Page 1 of 5

50Ω 9 khz to 4000 MHz Product Features Wide bandwidth, 9 khz to 4000 MHz 50 db Dynamic Range, -30 to +20 dbm Good VSWR, 1.1:1 typ. Fast measurement speed, 30 msec typ. Automatic frequency calibration & temperature compensation Multi-sensor capability (up to 24) Built in Application Measurement Software Remote operation via internet Effective, easy-to-use Windows GUI Compatible with 32/64-bit Windows or Linux operating systems Supports a wide range of programming environments (See application note AN-4-001 for details) Compliant Typical Applications Turn almost any Windows or Linux PC into a Power Meter Pocket-sized portability for benchtop testing anywhere Remote location monitoring Automatic, scheduled data collection Evaluate high-power, multi-port devices with built-in virtual couplers/attenuators & other software tools Case Style: JL1504 Installation CD Model No. USB smart Power Sensor Included Accessories PWR-SEN-4GHS Power Sensor Head USB-CBL+ Data cable (USB Type-A plug) NF-SM50+ N-Type (F) to SMA(M) Adapter PWR-SEN-CD Installation CD RoHS Compliant See our web site for RoHS Compliance methodologies and qualifications Mini-Circuits Power Meter Program for Smart USB Power Sensor Rev. C M155918 EDR-10382 RAV 160501 Page 2 of 5

Electrical Specifications (CW) 2, -30 dbm to +20 dbm, 9kHz to 4000 MHz Freq. Range (MHz) Min. Typ. Max. Units Dynamic Range 3 0.009-4000 -30 - +20 dbm VSWR 0.009-4000 - 1.1 1.4 :1 Uncertainty of Power Measurement @ 25ºC Uncertainty of Power Measurement @ 0ºC to 50ºC @ -30 to +5 dbm @ +5 to +12 dbm @ +12 to +20 dbm @ -30 to +5 dbm @ +5 to +12 dbm @ +12 to +20 dbm 0.009-1000 - ± 0.05 ± 0.35 db 1000-4000 - ± 0.05 ± 0.30 db 0.009-1000 - ± 0.05 ± 0.30 db 1000-4000 - ± 0.05 ± 0.25 db 0.009-1000 - ± 0.05 ± 0.30 db 1000-4000 - ± 0.10 ± 0.35 db Linearity @ 25ºC 0.009-4000 - ± 1.5 - % Measurement Resolution 0.009-4000 0.01 - - db Averaging Range 0.009-4000 1-999 - Measurement Speed @ Low Noise Mode - 100-0.009-4000 @ Faster Mode - 30 - msec Current (via host USB) 0.009-4000 - 40 70 ma Minimum System Requirements Interface Host operating system Hardware USB cable (supplied) USB HID Requirements Windows 32/64 Bit operating system: Windows 98, Windows XP, Windows Vista, Windows 7, Windows 8, Windows 10 Linux support: 32/64 Bit operating system Pentium II or higher, RAM 256 Mb, USB port Power sensor to be used with the supplied USB cable only Absolute Maximum Ratings Ratings Operating Temperature 0 C to 50 C Storage Temperature -30 C to 70 C DC Voltage at RF port CW Power Permanent damage may occur if any of these limits are exceeded. Operating in the range between operating power limits and absolute maximum ratings for extended periods of time may result in reduced life and reliability. 4V +25dBm 2 All specifications apply to continuous wave (CW) signals. 3 Maximum continuous safe operational power limit: +23 dbm. Performance is guaranteed up to +20 dbm. Page 3 of 5

Typical Performance Curves VSWR (:1) 1.30 1.25 1.20 1.15 1.10 1.05 0 C +25 C +50 C VSWR UNCERTAINTY (db) UNCERTAINTY (db) UNCERTAINTY OF POWER MEASUREMENT @ 25 C O C 0.30 0.15 0.00-0.15-30 dbm -10 dbm 0 dbm +5 dbm +12 dbm +15 dbm +20 dbm 1.00 0 500 1000 1500 2000 2500 3000 3500 4000 FREQUENCY (MHz) -0.30 0 1000 2000 3000 4000 FREQUENCY (MHz) Outline Drawing (JL1504) Linearity LINEARITY (%) (%) 4.0 3.0 2.0 1.0 0.0-1.0-2.0-3.0-30 to 0 dbm 0 to +20 dbm LINEARITY @ 25 C O C -4.0 0 1000 2000 3000 4000 FREQUENCY Frequency (MHz) Push-Pull Connector C Note 4,5 A E ±1.0" D N-Type Male Connector USB Type A Plug B inch Outline Dimensions ( mm ) A B C D E 4.89 1.74.95 3.50 81.9 124.2 44.2 24.1 88.9 2080 WT. GRAMS 250 4 Power sensor to be used with the supplied USB cable only. 5 Length shown for USB-CBL+. USB-CBL-2+ length is :15.2 in / 385 mm Power sensor to be used with the supplied USB cable only. Page 4 of 5

Ordering Information Model USB Smart Power Sensor Included Accessories Part No. Power Sensor Head PWR-SEN-CD Software CD USB-CBL+ 6 6.6 ft data cable with USB Type-A plug connector NF-SM50+ N-Type Female to SMA Male Adapter. 6 Power sensor to be used with the supplied control cable only. Optional Accessories USB-CBL+ (spare) USB-CBL-2+ NF-SM50+ (spare) 6.6 ft data cable with USB Type-A plug connector 15 in data cable with USB Type-A plug connector N-Type Female to SMA Male Adapter. Calibration CALSN- Calibration Service Click Here Additional Notes A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document. B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuit s applicable established test performance criteria and measurement instructions. C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, Standard Terms ); Purchasers of this part are entitled to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits website at www.minicircuits.com/mclstore/terms.jsp Page 5 of 5