Sanitary Type Electronic Flow Switches



Similar documents
Electronic Flow Switches

In-Line Electronic Flow Switches

In-Line Electronic Flow Switches

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

For Multi-Parameter Meters see mvx

Reliability Accuracy Performance

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Thermatel Model TA1 Mass Flow Transmitter

The Unique Accelabar Flow Meter

FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

T7079A,B Solid State Remote Temperature Controllers

Interface Level And Point Level Analyzers & Sensors

Galvanic Parts Per Million Dissolved Oxygen Systems

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Uncompromising Customer Service. Baumann TM Sanitary and Aseptic Process Valves

B-Series Temperature Switches

TC-9102 Series Surface Mount Temperature Controllers

Centro-Matic Automatic Lubrication Systems System Controls

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

COMBIMASS. Technical Data COMBIMASS eco-bio +

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

PRODUCT PROFILE FEATURES

O C M III. Open Channel Flow Monitor

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

General Purpose ph/orp Sensors

B-Series Switches Pressure, Differential Pressure & Hydraulic

Morrison Bros. Co. General Product Specifications

THERMAL MANAGEMENT SOLUTIONS

PIEZOMETER AIRFLOW MEASURING RING

Electronic, Digital and Mechanical Vibration Switches

VIBRATION SWITCHES SOLID STATE

SERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR WARNING VDC

MP-4000 Alarm List (Software version or later)

HL Series - Commercial Heaters Tankless Water Heating Solutions

Thermatel Enhanced Model TA2 Thermal Mass Flow Meter

FCI ST75 Series Flow Meters

Explosion-Proof Electric Unit Heaters

Thermal Mass Flow Meter (Series MST)

PART 1 - INTRODUCTION...

Powers Controls TH 192 S Single Temperature Room Thermostat

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Research RF Sputtering Packages

How To Clean Up A Reactor Water Cleanup

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

! WARNING. Before using product, read and understand instructions.

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Thermatel Model TD1/TD2 Thermal Dispersion Flow/Level/Interface Switch

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Sanitary and CIP Toroidal Sensor

Mono-Block II Installation & Operation Manual

Typical Aluminum GFM Mass Flow Meter

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MG Transmitter with Digital Output.

Baumann Flexsleev Sanitary Control Valve

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Water Leak Detection System

Micro Motion Model D and DL Coriolis Flow and Density Meters

Table of Contents. TransformerIQ FAQs 1

4 Posiflow Proportional Solenoid Valves

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Excellence through Versatility

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS

Technical Specification. Generating Set with Waukesha engine burning natural gas

System 350 A350E Electronic Cooling Control

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

A99B Series Temperature Sensors

DigitalFlow GF868. Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range. GE Sensing & Inspection Technologies.

TECHNICAL BROCHURE BAQUABII. * Available up to 100 GPM systems. Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

Flow Monitoring System

300 Series PA Pump and Cooler Assemblies

Thermal Dispersion Mass Flow

Toroidal Conductivity Sensor

B.D.I. The B.D.I. (Burst Disc Indicator) Alarm System is designed for use with Continental Disc

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

DPI 260 SERIES: Digital Pressure Indicators

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

INSTALLATION INSTRUCTIONS GEO-BOOSTER TM

DeltaSpan Submersible Pressure Level Transmitter Manual LD31 Series 22 AUG 08 Rev A

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

Oil and Coolant Circulating Heating System. Model - OCSM

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

OPTIMASS 6000 Technical Datasheet

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

REGULATORS 175/153 Series

Echotel Model 910. Installation and Operating Manual. Ultrasonic Level Switch

Ozone Sensor. Model 499A OZ CAUTION CAUTION. Instruction Sheet PN 51A-499AOZ/rev.F January 2007

Transcription:

Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls

Features No Moving Parts 36L Stainless Steel Temperatures to +350F Simple and Easy Field Calibration Explosion Proof Nema 4 Enclosure Low Flow Rate Detection Sanitary Process Connections 3A Sanitary Design Field Programmable Relay Energization Special Ra Polish & Electropolishing Optional Remote Mounted Electronics S-005 with /2 Short Leg Tee Specifications Sensor Head Material of 36L Stainless Steel Standard Construction: Option Electropolished to 5Ra Operating -50 to +350F (-46 to +77C) Standard Temperature: Operating Vacuum to 2000 PSIG (207 Bar) Pressure: Response Time: From 3 Seconds Repeatability: ± 0.5% of Range at Constant Conditions Process ½, 2 Tri-Clamp Cap Standard Connection: Option 3, 4 Tri-Clamp Cap Probe Length:.8,.0 ; Option Customer Specified 2 Electronics Housing: Temperature: Power Input: Output: S-005-.0 with Instrument Tee Electrical Connection: Shipping Weight: Powder Coated Explosion Proof, Nema 4, UL/CSA Rated to Class, Div. & 2, Group B,C,D; Class II, Div. & 2, Group E,F,G; Class III. Option FM and Cenelec/ATE -50 to +50F (-46 to +65C) 20 VAC, 50/60 Hz, 4 Watts; Options: 24 VDC/VAC, 240VAC SPDT 3 Amps Resistive Standard See page 4 for options FNPT 5 lbs

Operation The S sanitary series flow switch has been designed to meet the most critical flow detection applications in the food, pharmaceutical, biotechnology, and water treatment industries. Quick disconnect tri-clamp caps are standard with special finishes for 3A applications and polished/ electropolished for biotechnology and pharmaceutical use. The thermal dispersion principle of operation features no moving parts exposed to the process. The instrument operates by measuring a temperature differential between a heated and a reference temperature sensor (see figure ). An extremely low power heating element is attached to a temperature sensor and a second temperature sensor is isolated from the heater to provide compensation for changing process temperature. The electronics measure the differential and can be adjusted to switch at any flow listed in the flow switch set-point range chart. Extremely low flow rates such as.04 GPM in a line can be detected with rangeability up to 300:. These flow switches can be used in virtually all liquids, gases, and slurries. Flow Switch Set-Point Range The electronics are available with single or dual switch points. Temperature monitoring is also available with either a switch output or a linear 4-20 ma output. Relay outputs are standard and are offered with several different configurations and contact ratings. Remote mounting of the electronics is also available. Heater and Temperature Sensor # Temperature Sensor #2 Temperature Differential = Temperature Sensor # Minus Temperature Sensor #2 Figure WATER/ AQUEOUS SYRUP AIR/GAS VELOCITY FPS (FEET PER SECOND) Conversion Table Volumetric (GPM or CFM) to Velocity (Feet per Second - FPS) Pipe Size Liquid Air Tube Size Liquid Air 0.05..5.0 5 0 50 00 500 SET-POINT RANGE STANDARD /8 /4 3/8 /2 3/4.25.5 2 2.5 3 3.5 4 5 6 5.65 3.08.68.06.602.37.25.58.096.067.0434.0325.0252.060.0 42.9 23.06 2.57 7.9 4.50 2.78.6.8.76.502.325.243.88.20.083 /2 3/4.5 2 3 4 6 2.2.884.473.200.086.0476.0265.062 6.5 6.6 3.53.49.82.356.98.0869 3 NORMAL FLOW Examples: ) 00 CFM in 3 Tube = 00 x.356 = 35.6 FPS 2) 0 GPM in 3 Tube = 0 x.0476 =.476 FPS

Circuit Board Options Standard Single Switch Point Electronics SPDT relay output with 3 or 0 amp contacts DPDT relay option with 3 or 0 amp contacts Wide selection of power inputs including 24 VAC or VDC, 20 VAC, or 240 VAC This circuit board is the standard used in the S series flow switches. The electronics offer constant current sensor excitation, precision signal amplification, and highly repeatable switching circuitry for reliable operation in even the most demanding applications. Optional Dual Switch point Electronics Two separately adjustable switch points SPDT relay output for each set point with 3 or 0 amp contacts Power inputs include 24 VAC or VDC, 20 VAC, or 240 VAC The optional dual switch point electronics provide two independently adjustable switch points that can be used to detect any two combinations of decreasing and/or increasing flow. Single Switch Point Electronics with Additional Temperature Transmitter Temperature transmitter (3 wire 00 Ohm platinum RTD sensor) with loop powered 4-20 ma output SPDT relay output for flow switch with 3 or 0 amp contact rating Flow switch power inputs include 24 VAC or VDC, 20 VAC, or 240 VAC This option provides the user with a highly reliable flow switch with an accurate temperature transmitter. The temperature transmitter provides a industry standard linearized 4-20 ma signal. The temperature output is loop powered and can operate from 8-36 VDC. Single Switch Point Electronics with Additional Temperature Switch Temperature switch point available from -50F to +350F SPDT relay output for flow and temperature with 3 or 0 amp contact rating Customer specified power inputs include 24 VAC or VDC, 20 VAC, or 240 VAC This optional circuit board monitors two process variables, flow and temperature, with one instrument. Cost savings are realized by the user since the instrument has only one process connection and one conduit run. Applications include monitoring cooling water and all other applications shown on page 5 of this brochure. 4

Optional Calibrator Flow Switch Calibrator Model MC-5 Displays mv output which is proportional to flow Induces signal to electronics for setting specified switch point Allows periodic switch point verification This tool is not needed for a vast majority of users. It is useful when a user has large quantity of units and requires periodic verification of switch point calibrations. This easy to use hand held, self powered instrument can be used in conjunction with all single or dual switch point circuit boards. By simply plugging this instrument into the circuit board, the user can interrogate all functions of the flow switch. Flow Switch Applications Suitable for CIP systems Pump Protection: Automatic shut down on low or no flow Control Rooms: Verifies flow when fans, pumps or valves are energized Reliably used in extremely viscous fluids Electropolished sensors available Relief Valve/Rupture Disks: Alarms on flow or leakage of safety relief valves or rupture disks Spray Nozzles: Detects nozzle blockage in coating applications Purge Air: Detects loss of flow for process or plant safety Chiller Lines: Automatic shut down of chillers on low or no flow Heater Burnout Prevention: Heater shutdown on loss of flow to prevent overheating of elements Drain Line Sensor: Capable of detecting flow in partially filled lines Deionized/ Ultrapure Water Flow Sensor Agitation Monitor: Positive indication of agitation in tanks 5

PART NUMBER/ ORDER ENTRY SPECIFICATION S SERIES SANITARY FLOW SWITCH PROCESS CONNECTION OPTIONS - NO ENTRY REQUIRED FOR BOES WITH S- - ½ Tri-Clamp Cap 0 0 5 2 Tri-Clamp Cap 2 0 0 5 3 Tri-Clamp Cap 3 0 0 5 4 Tri-Clamp Cap 4 0 0 5 INSERTION LENGTH.8 STANDARD.0 OPTIONAL. 0 SPECIAL - SPECIFY LENGTH IN INCHES POWER INPUT 7 VAC (90-32VAC) 24 VDC or VAC (+/- 0%) D 200-240 VAC A PROCESS TEMPERATURE -50F TO +350F LOCAL ELECTRONICS REMOTE ELECTRONICS R CABLE TYPE PVC (200F) H CABLE TEFLON (500F) I CABLE LENGTH FT. RELAY OUTPUTS SPDT 3 AMP RESISTIVE SPDT 0 AMP RESISTIVE J DPDT 3 AMP RESISTIVE K DPDT 0 AMP RESISTIVE L DUAL SWITCH POINTS SPDT 3 AMP RESISTIVE M SPDT 0 AMP RESISTIVE N Ameritrol, Inc. 85L Park Center Drive Vista CA 9208 760-727-7273 Phone 760-727-75 Fax -800-90-6689 Visit our website at www.ameritrol.com ADDITIONAL TEMPERATURE SWITCH SPDT 3 AMP RESISTIVE T SPDT 0 AMP RESISTIVE T 2 ADDITIONAL TEMPERATURE TRANSMITTER MEASURED TEMPERATURE RANGE T T - FAHRENHEIT (F) OR CELSIUS (C) SENSOR HEAD MATERIAL 36L STAINLESS STEEL HOUSINGS UL/CSA APPROVED P/NEMA 4 FM APPROVED P/NEMA 4 P CENELEC/ATE APPROVED P/NEMA 4 Q STAINLESS STEEL TAG T MILLIVOLT OUTPUT m V Special Electropolishing (5 Ra) E P Note Only one of these options can be selected. Example: S-005 S Series flow switch with ½ triclamp cap process connection,.8 insertion length, 7 VAC power input, -50 to +350 F process temperature, single switch point with SPDT 3 amp contact rating, UL/CSA approved explosion proof (P)/ NEMA 4 housing. Example: S-2005-DJTT0-00CEP S Series flow switch with 2 tri-clamp cap process connection,.8 insertion length, 24 VDC or VAC power input, -50 to +350F process temperature, single switch point with SPDT 0 amp contact rating, additional temperature transmitter with range 0 to 00C, UL/CSA approved explosion proof (P)/NEMA 4 housing, 36L stainless steel sensor head, with all wetted parts electropolished. Bulletin S3-02 6