High Vacuum Transformer Oil Purification Systems (HVTOPS) & Dielectric Oil Purification Systems (DOPS)



Similar documents
Vacuum Dehydration Oil Purification System (VDOPS)

Medical Air Systems: Scroll

CSD WATER REMOVAL FILTERS FOR DIESEL

DIESEL FUEL CONDITIONING

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

SMR Series Submicronic Removal Fluid Purifi cation Systems

What is Oil Filtration By Dennis Morgan, Filtration Consultant and President of AMS Filtration April 8, 2008

DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications:

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

PVS Series - Models 185, 600, 1200, 1800 and 2700

Kompressoren. Adsorption Dryer AD

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Standard Hydraulic Piping Flushing Procedure

Oil and Coolant Circulating Heating System. Model - OCSM

300 Series PA Pump and Cooler Assemblies

Pumping Fuel & Fuel Oil

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Rexroth Hydraulic Pump A10VO Series User Manual

Magnum Mobile Generator MMG55 Specifications

Model 1210C Battery Powered Pump Shown. Description

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

Rotary screw compressors kw 5,5 7, , bar MODULO

NORMAN FILTER COMPANY PRODUCT OVERVIEW

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: w.tecni-ar.com.br

Stack Sampling Stack sampling or source sampling

US VACUUM CP SERIES MANUAL. Oil Lubricated, Rotary Vane Vacuum Pumps INSTALLATION OPERATION. Models CPS-5B & CPS-8B WARNING

Power consumption (kw)

Electronic Flow Switches

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

MAC-120HE-01 Air-Cooled Chiller

Your oil can be saved!! Even when water is mixed

Atlas Copco Quality Air Solutions. Compressed Air Filters

Atlas Copco Generators

Sterile ReadyToProcess Hollow Fiber Cartridges Instructions for Use

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Cooking at the Speed of light!

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Training Syllabus to Instruct/Prepare for the ASE Transit Bus HVAC Test

Energy Recovery Device isave 21-40

Portable Purification Systems Models PVS 185, 600, 1200, 1800, 2700

Diesel Engine Driven Generators Page 1 of 6

ROTARY SCREW COMPRESSOR. RMD kw

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Bulk Storage the OIL SAFE Way. Three System Types. Establish Best Practice

Technical Specification. Generating Set with Waukesha engine burning natural gas

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

ECOCIAT. Domestic hot water heat recovery unit

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Modular Glovebox Systems Gas Purifier Units Antechambers Accessories

Installation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG

INDUSTRIAL POWER GENERATION EQUIPMENT Typhoon SGT MW / 5340 KVA 50Hz 11KV Duel Fuel Power Station

MEMBRANE VACUUM MINI PUMPS

SWIMMING POOL HEAT PUMP Owners Manual

1. Conductivity < 15 micro ohms/cm 2. ph of 6.0 to Nonvolatile TOC content < 1.0 ppm

ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric energy and heat -

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

A Guide to Trouble-Free Cooling Towers

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

In-Line Electronic Flow Switches

RMF TANDEM 900 OFF-LINE FILTER SYSTEMS

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY

Air Eliminators and Combination Air Eliminators Strainers

ice 3 FLUID TO FLUID HEAT PUMP

Adsorption air dryers ADS 1 215

Desiccant Air Dryers Heatless, Heated and Heated Blower

Competency Framework for Marine Engineer Class 6. Competency Framework for Marine Engineer Class 6

This chapter is devided into two sections:

DESIGN STANDARDS SECTION

CARING FOR YOUR WATER HEATER

Backflush filter R8-30W

ASME Packaged Indirect Fired Water Heater

SIOUX HYBRID WATER HEATER

ON-VEHICLE INSPECTION

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

WINDOW ROOM AIR CONDITIONER

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

Brownie s. Tankfill. and. NitroxMakers

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN

400B SERIES DIAPHRAGM PUMP

Quiz On Information Learned From Chapter 1

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

Commercial Electric Water Heater

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

Automatic Back-Flushing Filter AutoFilt RF9.

Condensing unit type EPSILON-ECHOS LE Technical information manual

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Bulk System Gallery. Bulk Storage Systems. OIL SAFE Bulk Storage Systems can be configured or customized to suit your application and budget.

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

FAIRBANKS NIJHUIS PACKAGED FIRE PUMP SYSTEMS.

QSV Series Vacuums an EnPro Industries company QUINCY QSV SERIES ROTARY SCREW VACUUM PUMPS 7.5 HP TO 200 HP

Electrical Maintenance Workshop

BHS CANDLE FILTER APPLICATIONS FOR CLARIFICATION / RECOVERY OF SOLIDS FROM CHEMICAL SLURRIES

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Axial and Mixed Flow Pumps for Large Volume Pumping

Element D Services Heating, Ventilating, and Air Conditioning

Transcription:

High Vacuum Transformer Oil Purification Systems (HVTOPS) & Dielectric Oil Purification Systems (DOPS) To achieve optimal dielectric strength and insulating performance inside of transformers and circuit breakers, dielectric oils must be kept absolutely clean and dry. High Vacuum Transformer Oil Purificn Satioystems can quickly and reliably process transformer oil to meet or exceed very stringent specifications. By removing all impurities from dielectric insulating oils during substation maintenance or new fill, these systems will improve and optimize: n Dielectric Strength to meet or exceed 40 Kva per ASTM D877 n Interfacial Tension to meet or exceed 40 dynes/cm per ASTM D971 n Power Factor to achieve 0.5% at 25 C or lower n Total Acid Number to achieve.05 mg KOH/gm or lower (when equipped with Fullers Earth option)

Two Methods to Quickly and Since 1999, Oil Filtration Systems, LLC has been designing and manufacturing equipment for the maintenance (dehydration and degassification) of electrical insulating oils. Whether you choose a single-pass High Vacuum Transformer Oil Purification System (HVTOPS), or a multi-pass Dielectric Oil Purifier System (DOPS), you can: n Remove 100% of free water and 99% of dissolved water to achieve overall moisture content <10 ppm n Remove all dissolved air & entrained gases to achieve overall content <0.25% n Remove all carbon and particulate contamination down to 1-micron using high efficiency pleated microglass filter elements rated Beta>1000 per ISO 16889 (absolute) n Remove acids and surfactants (when necessary) utilizing Fullers Earth or Activated Alumina cartridges Both types of systems (HVTOPS and DOPS) are available in a variety of process flow rates depending on the application, as follows: n 5 GPM (1135 LPH) n 10 GPM (2271 LPH) n 20 GPM (4542 LPH) n 30 GPM (6814 LPH) n 44 GPM (10000 LPH) Effective for use on: n Paraffin-based insulating oil n Naptha-based insulating oil n Silicone-based insulating oil n Envirotemp FR3 insulating oil 2

Reliably Optimize Your Insulating Oils 10 GPM NEMA 4 High Vacuum Transformer Oil Purification System 20 GPM NEMA 7 High Vacuum Transformer Oil Purification System (Class 1, Div 2) 30 GPM NEMA 4 High Vacuum Transformer Oil Purification System 10 GPM NEMA 4 Dielectric Oil Purification System 3

High Vacuum Transformer Oil Purification Auxiliary Flanged Ports for Freeze Trap to help diagnose and measure removed water and chemicals. Super Bright LED Tower Light permits easy monitoring of oil level and process inside tower. LED is rated for over 10 years continual use. Large Capacity Vacuum Tower Loaded with Coalescer Dispersal Elements for maximum surface area and water extraction rates. NEMA 4 Electric Control Panel with digital temperature controller, digital Torr gauge, and all alarm indicators. All Flanged or Welded Pipe and Fittings (no threaded connections) for fewer leak paths Second Stage High CFM Positive Displacement Blower Primary Stage Rotary Vane Roughing Pump provides greatly reduced DB noise level and vibration versus other systems employing piston type pumps. No external cooling system required for vacuum pump or booster NEMA 4 Electric Control Panel with VFD s for both inlet and oil discharge pumps; includes soft start for vacuum pump and blower which significantly increases motor life. High Vacuum Transformer Oil Purification System (HVTOPS) n Re-Circulates oil inside of a de-energized transformer or in a tanker truck to remove water, entrained gases, and particulate contamination. A single pass through the system yields 10 ppm or lower water content for quick turnarounds. n Dries out paper windings by pulling deep vacuum on empty transformers. Systems are equipped with a 2-stage vacuum pump and blower, operating at 0.5 Torr or lower. 4

Systems (HVTOPS) Low Watt Density Heater with digital temperature controller, high limit process thermocouples, and multiple isolated circuits. FM approved configuration. Knock-out Pot for Blower / Vacuum Pump protection with alarm shutdown. Vacuum Rated Flanged Ball Valves Positive Displacement Gear Pump for oil inlet, speed controlled with Variable Frequency Drive (VFD). Two High Efficiency 1 Micron Pleated Microglass Elements rated Beta>1000 per ISO 16889. Rotary Gear Flow Meter and Totalizer with digital display on panel Dry-Out Connection for pulling deep vacuum on empty transformers Foam Sensor with automatic vacuum break Double Mechanical Seal Gear Pump for oil discharge, speed controlled with VFD; helps reduce cavitation. Standard features for HVTOPS n Specially designed horizontal vacuum tower loaded with high efficiency dispersal elements for optimal water extraction rates n Foam sensor with automatic vacuum break n Inlet pump positive displacement gear type n Oil discharge pump positive displacement gear type with double Viton Mechanical Seal n Variable frequency drives enables operator to effectively dial in the optimal system flow rate n Low watt density heater with high limit and process thermocouples to safely and effectively raise the oil temperature, along with digital temperature controller n 2-stage vacuum pump and blower capable of pulling 10-4 Torr at dead-head (operating at 0.5 Torr or lower) n Pre-filter and polishing filter elements (0.5 micron nominally rated, or 2.5 Micron Beta>1000 per ISO 16889) n NEMA 4 electric control panel with Siemens PLC, pushbutton on-off switches, and alarm indicator lights n Dry-out connection to pull deep vacuum on empty transformers n Connection ports for optional Fullers Earth housing n Bypass valve assembly for internal circulation and oil pre-heating n Sight flow indicator on inlet and outlet n Inline digital flow meter and totalizer n Heavy duty carbon steel skid base with spill containment lip and forklift slots For options, see back cover. 5

Dielectric Oil Purifier System (DOPS) Designed to remove all impurities from dielectric insulating oils in multi-pass. n Dielectric Strength to meet or exceed 40 Kva per ASTM D877 n Interfacial Tension to meet or exceed 40 dynes/cm per ASTM D971 n Power Factor to achieve 0.5% at 25 C or lower n Total Acid Number to achieve.05 mg KOH/gm or lower (when equipped with Fullers Earth option) This system is equipped with a single stage vacuum pump and no blower, so it does not have a dry-out port to pull deep vacuum on empty transformers. Otherwise, it has all of the same features and functions as the High Vacuum Transformer Purification System. Standard features for DOPS n Specially designed horizontal vacuum tower loaded with high efficiency dispersal elements for optimal water extraction rates n Foam sensor with automatic vacuum break n Inlet pump positive displacement gear type n Oil discharge pump positive displacement gear type with double Viton Mechanical Seal n Variable frequency drives enables operator to effectively dial in the optimal system flow rate n Low watt density heater with high limit and process thermocouples to safely and effectively raise the oil temperature, along with digital temperature controller n 1-stage vacuum pump operating down to 1 Torr n Pre-filter and polishing filter elements (0.5 micron nominally rated, or 2.5 Micron Beta>1000 per ISO 16889) n NEMA 4 electric control panel with Siemens PLC, pushbutton on-off switches, and alarm indicator lights n Connection ports for optional Fullers Earth housing n Bypass valve assembly for internal circulation and oil pre-heating n Sight flow indicator on inlet and outlet n Inline digital flow meter and totalizer n Heavy duty carbon steel skid base with spill containment lip and forklift slots For options, see back cover. 6

Model Selection Key Custom Options: Z = Custom Equipment (Specified) HVTOPS - 30VFD - 840X - 33kW - 4PLL - DOMI - DPM - SS - ETM - 150/1800-480 - N4 - V - Z Flow Rate: 5VFD = 5 GPM Variable Flow (1200 L/Hour) 10VFD = 10 GPM Variable Flow (2300 L/Hour) 20VFD = 20 GPM Variable Flow (4600 L/Hour) 30VFD = 30 GPM Variable Flow (6800 L/Hour) 44VFD = 44 GPM Variable Flow (10,000 L/Hour) High Vacuum Transformer Oil Purification System Heater Rating: 33kW = 33 kilowatt 66kW = 66 kilowatt 96kW = 96 kilowatt 120kW = 120 kilowatt 180kW = 180 kilowatt Filtration: 820X = OFS-820X (Series) Cartridge *For 1-5 GPM 840X = OFS-840X (Series) Cartridge *For 10-44 GPM *Optional Equipment: 4PLL = 4-Point Lifting Lugs DMI = Digital Moisture Indicator DOMI = Doble Moisture Indicator DPM = Digital Particle Monitor SS = Stainless Steel Wetted Components TM = Trailer Mounted ETM = Enclosed Trailer Mounted Vacuum/Booster Rating: 70/400 = 70 CFM Roughing Pump / 400 CFM Booster 70/800 = 70 CFM Roughing Pump / 800 CFM Booster 130/1200 = 130 CFM Roughing Pump / 1200 CFM Booster 150/1800 = 150 CFM Roughing Pump / 1800 CFM Booster Electrical Requirement: 208 = 208V / 3Ph / 60Hz 220 = 220V / 3Ph / 50Hz 220V / 3Ph / 60Hz 380 = 380V / 3Ph / 50Hz 400 = 400V / 3Ph / 50Hz 415 = 415V / 3Ph / 50Hz 480 = 480V / 3Ph / 60Hz 575 = 575V / 3Ph / 60Hz Electrical Rating: N4 = NEMA 4 N7 = NEMA 7 Explosion Proof Seal Material: V = Viton B = Buna N Rental Fleet of Systems Available for Quick Shipment Oil Filtration Systems, LLC keeps a rental fleet of transformer oil purification units ready for emergency mobilization anywhere in the world. Our experienced field service technicians can either walk you through easy start-up procedures over the phone or accompany the system to your jobsite to help with start-up, commissioning, and training. 30 GPM HVTOPS 7

Employs High Efficiency Filter Elements Oil Filtration Systems, LLC manufacturers its own high-efficiency filter elements for particulate removal from all mineral-based and synthetic hydraulic, lubrication, dielectric, and fuel oils. OFS elements are constructed of the highest quality micro-fibrous glass filtration medias utilizing serial filtration technology, and the medias are layered to achieve optimal performance characteristics. OFS elements are suitable for use in the most demanding applications, and they are designed and tested to provide the highest level of efficiency with the maximum dirt holding capacity. All OFS filter elements have particulate removal efficiencies of Beta(c)>1000 (99.9% for the stated micron size), which is based on ISO 16889-1999 testing standards. They are available in a wide range of micron sizes to suit virtually any application (2.5, 5,7,12, and 22-Micron). Optional features for both HVTOPS and DOPS n Inline digital moisture indicator (Doble Domino ) n Fullers Earth Housing Assembly n All analog controls (relays and contactors) n Enclosed trailer with rear and side access doors n Fully customized tractor trailer rig with lab room, space heater, and /or air conditioner n Onboard diesel powered generator for independent operation n Hose reels on inlet and outlet n NEMA 7 explosion proof (Class 1, Division 2, Groups B, C & D) n Connection ports for optional freeze trap 111 Parkway Drive Boerne, Texas 78006 Toll Free (800) 449-0262 (830) 816-3332 Fax: (830) 816-3331 www.oilfiltrationsystems.com Viton is a registered trademark of E. I. du Pont de Nemours and Company. Domino is a registered trademark of Doble Engineering Company. Envirotemp and FR3 are trademarks of Cargill, Incorporated. 2013 The Clark-Reliance Corporation Printed in U.S.A.