ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.



Similar documents
Three-phase monitoring relay CM-PFE

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Analog signal converters CC-E I/I Current / current isolators

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF19 and EF45

Thermistor motor protection

Three-phase monitoring relays Product group picture

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

RM4TG20 three-phase network control relay RM4-T - range V

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Catalog. Modular DIN rail components Installation contactors

Technical catalogue. Modular DIN rail components Installation contactors

Manual motor starter MS116

Pluggable interface relays CR-P Pcb relays

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

48 SERIES Relay interface modules 10 A

EMR measuring and monitoring relays

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Safety technique. Emergency stop module BO 5988 safemaster

49 Series - Relay interface modules A. Features

Grid feeding monitoring according to VDE-AR-N 4105 and BDEW CM-UFD.M31

38 Series - Relay interface modules A

Signal converters Index

System pro M compact Miniature Circuit Breaker S 200/S 200 M

PHOENIX CONTACT Features

38 Series - Relay interface modules A

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Type: DILM32 10(24V50HZ) Article No.:

Relés e Contatores de Estado Sólido SIRIUS

Type: DILM9 10(24VDC) Article No.:

80 Series - Modular timers 16 A. Features

Signal converters Index

MasterINTERFACE 39 Series - Relay interface modules

15 Series - Electronic step relay and dimmer. Features SERIE

80 Series - Modular timers 16 A. Features

MasterINTERFACE 39 Series - Relay interface modules

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

40 Series - Miniature PCB/Plug-in relays A. Features

Technicaldata General

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

ZS25 Screw Clamp Terminal Blocks Feed-through

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

STRATO LED Drivers 70W, Single output

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

mecotron Safety relay ESTOP-2 For emergency stop monitoring

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

ABB i-bus KNX SA/S Switch Actuators Product Manual

Digital input modules

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Power Supplies 3. SDN-P DIN Rail Series

Bimetallic Overload Relay Specifications

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

Soft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D E 0 VD00

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Energy Management Energy Meter Type EM23 DIN

ZS10 Screw Clamp Terminal Block

Voltage Regulator SPAU 341 C. Product Guide

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

PSR The compact range Description

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Manual Motor Starter MS 116 up to 16 A Technical Data

Thermal-Magnetic Circuit Breaker M1-..

ABB i-bus KNX Switch Actuators SA/S Product Information

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

CompactLogix Power Supplies Specifications

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

R.C.C.B. s two-pole LEXIC

Waveguide Access Point WGA631. Product Guide

Transcription:

1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay status 2 Marker label A C D K E L UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC RMRS Marks a b CE C-Tick Order data Type Rated control supply voltage = measuring voltage Order code 3 x 0-500 AC 1SR 430 824 R9300 Order data - Accessories Type Description Order code ADP.01 Adapter for screw mounting 1SR 430 029 R0100 MAR.01 Marker label 1SR 366 017 R0100 CO.01 Sealable transparent cover 1SR 430 005 R0100 Application The is used to monitor three-phase mains for incorrect phase sequence and phase failure. Operating mode Signalling is made by means of the front-face LED. LED Function Output contact closed R: yellow LED ABB 1

Function descriptions/diagrams Function diagram legend G Control supply voltage not applied / Output contact open / LED off B Control supply voltage applied / Output contact closed / LED glowing Phase sequence and phase failure monitoring If all phases are present with the correct phase sequence, the output relays energize after the start-up delay t s is complete. If a phase failure or a phase sequence error occurs, the output relays de-energize instantaneously. The LED R glows when the output relays are energized. In case of motors which continue running with only two phases, the detects phase failure if the reverse fed voltage is less than 60 % of the originally applied voltage. L1, L2, L3 Measuring value 11-14 11-12 21-24 21-22 R: yellow LED t s L1, L2, L3 L1, L3, L2 L1, L2, L3 L1, L2 L1, L2, L3 L1 L1, L2, L3 t s = start-up delay fixed 500 ms L3 L2, L3 2CDC 252 013 F08 Connection diagram L1 L2 L3 L1 L2 L3 1115 2125 1216 1418 2226 2428 2226 2125 2428 1216 1115 1418 1SC 110 000 F0118 L1, L2, L3 Control supply voltage = measuring voltage 11 15-12 16 /14 18 Output contacts - 21 25-22 26 /24 28 closed-circuit principle 2 ABB

Data at T a = 25 C and rated values, unless otherwise indicated Type Supply circuit = measuring circuit L1, L2, L3 Rated control supply voltage U S = measuring voltage 3 x 0-500 AC Power consumption approx. 15 A Rated control supply voltage U S tolerance -15...+10 % Rated frequency 50/60 Hz Duty time 100 % Measuring circuit L1, L2, L3 Monitoring functions phase failure J phase sequence J Measuring ranges 3 x 0-500 AC Thresholds U min 0.6 x UN Hysteresis related to the threshold value Measuring voltage frequency 50/60 Hz Response time 500 ms Accuracy within the rated control supply voltage tolerance iu m 0.5 % Accuracy within the temperature range iu m 0.06 % / C Timing circuit Start-up delay t S fixed 500 ms Tripping t - Indication of operational states Relay status R: yellow LED Output relay energized Output circuits 11(15)-12(16)/14(18), 21(25)-22(26)/24(28) Kind of output 2 c/o (SPDT) contacts Operating principle 1) closed-circuit principle Contact material AgNi Rated operational voltage U e (IEC/EN 60947-1) 250 Minimum switching voltage / Minimum switching current - / - Maximum switching voltage 250 AC, 250 DC Rated operational current I e AC12 (resistive) 230 4 A (IEC 60947-5-1) AC15 (inductive) 230 3 A DC12 (resistive) 24 4 A DC13 (inductive) 24 2 A Mechanical lifetime 30 x 10 6 switching cycles Electrical lifetime (AC12, 230, 4 A) 0.1 x 10 6 switching cycles Max. fuse rating to achieve n/c contact 4 A fast-acting short-circuit protection n/o contact 6 A fast-acting AC rating Utilization category (Control Circuit Rating Code) B 300 (UL 508) max. rated operational voltage 300 AC max. continuous thermal current at B 300 5 A max. making/breaking apparent power at B 300 3600/360 A General data Dimensions (W x H x D) 22.5 x 78 x 100 mm (0.89 x 3.07 x 3.94 inch) Mounting DIN rail (IEC/EN 60715) Mounting position any Minimum distance to other units horizontal / vertical M 10 mm if the control supply voltage is higher than 415 Degree of protection enclosure / terminals IP50 / IP Electrical connection Wire size fine-strand with wire end ferrule 2 x 0.75-2.5 mm² (2 x 18-14 AWG) fine-strand without wire end ferrule 2 x 0.75-2.5 mm² (2 x 18-14 AWG) rigid 2 x 0.5-4mm² (2 x -12 AWG) Stripping length 7 mm (0.28 inch) Tightening torque 0.6-0.8 mm Environmental data Ambient temperature range operation / storage -..+60 C / -40...+85 C Environmental testing (IEC 68-2-30) 24 h cycle time, 55 C, 93 % rel., 96 h Operational reliability (IEC 68-2-6) 4 g Mechanical resistance (IEC 68-2-6) 6 g Umax ABB 3

Data at T a = 25 C and rated values, unless otherwise indicated Type Isolation data Rated insulation volt. between supply, measuring and output circuits (DE 0110, IEC 60947-1) 500 Rated impulse withstand voltage U imp between all isolated circuits (DE 0110, IEC 664) 4 k / 1.2-50 µs Test voltage between all isolated circuits (routine test) 2.5 k, 50 Hz, 1 min. Pollution category (DE 0110, IEC 664, IEC 255-5) 3 Overvoltage category (DE 0110, IEC 664, IEC 255-5) III Standards Product standard IEC/EN 60255-6 Low oltage Directive 06/95/EC EMC Directive 04/108/EC Electromagnetic compatibility Interference emission to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 k/ 8 k) radiated, radio-frequency, electro- IEC/EN 61000-4-3 magnetic field Level 3 (10 /m) electrical fast transient (burst) IEC/EN 61000-4-4 Level 3 (2 k / 5 khz) surge IEC/EN 61000-4-5 Level 4 (2 k L-L) conducted disturbances, induced IEC/EN 61000-4-6 by radio-frequency fields Level 3 (10 ) Interference emission IEC/EN 61000-6-4 1) Closed-circuit principle: Output relay is de-energized if the measured value exceeds/drops below the adjusted threshold. Technical diagrams Load limit curves AC load (resistive) DC load (resistive) 300 0 100 80 60 50 40 30 2CDC 252 194 F05 300 0 100 80 60 50 40 30 2CDC 252 193 F05 10 0.1 0.2 0.5 1 2 4 6 10 I A 10 0.1 0.2 0.5 1 2 4 6 10 I A Derating factor F Contact lifetime at inductive AC load F 1.0 0.9 0.8 0.7 0.6 0.5 2CDC 252 192 F05 Switching cycles 250 resistive load 2CDC 252 148 F06 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos ϕ Switching current [A] 4 ABB

Dimensions in mm 109.5 4.31 102 4.02 22.5 0.886 78 3.07 1 0.039 100 3.94 5.5 0.216 2CDC 252 031 F0003 Dimensions - Accessories in mm 6.5 0.256 62.5 2.461 60 2.362 70 2.756 10 11.5 0.394 0.453 0.787 2CDC 252 008 F0010 3A11 0.787 8 0.315 2CDC 252 186 F0005 ADP.01 - Adapter for screw mounting MAR.01 - Marker label 22.5 0.886 7 0.275 3.5 0.138 2.70 68.5 front-to-back size 107 2CDC 252 185 F0005 CO.01 - Sealable transparent cover Further documentation Document title Document type Document number Electronic Products and Relays Technical catalogue 2CDC 110 004 C0x CM-PAS,, CM-PSS, CM-PS Instruction manual 1SC 630 510 M0000 You can find the documentation online at www.abb.com/lowvoltage -> Control Products -> Electronic Relays and Controls -> Three phase monitors. CAD system files You can find the CAD files for CAD systems at http://abb-control-products.partcommunity.com/partcommunity/portal/abb-control-products -> Low oltage Products & Systems -> Control Products -> Electronic Relays and Controls -> Three Phase Monitors -> CM-PFx - Three Phase Monitors. ABB 5

Contact us ABB STOTZ-KONTAKT GmbH P. O. Box 10 16 80 69006 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-mail: info.desto@de.abb.com You can find the address of your local sales organisation on the ABB home page http://www.abb.com/contacts -> Low oltage Products and Systems Document number. 2CDC 112 135 D01 (07/12) Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 12 ABB All rights reserved