Case Studies of Successful Code for Sustainable Homes Projects



Similar documents
THE CODE FOR SUSTAINABLE HOMES. Case studies

D 4.4 Activity Report Technical support during the planning phase of new buildings

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

Energy Company Obligation (ECO): Technical Monitoring Questions

SCHEDULE OF FINISHES AMBLE RIDGE RETIREMENT VILLAGE

BER Assessors Dwellings Technical Bulletin

Rainwater Harvesting

Proposal to achieve Code for Sustainable Homes Level 3 for a development of 7 detached dwellings

main heating: pre1998 ducted warm air system main heating fuel: mains gas main heating SAP efficiency: 70.0% main heating controls: programmer

Building Control Guidance Note

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

Low Carbon Domestic Refurbishment

Timber Frame Walls Rethinking Construction

RESPONSIBILITY FOR REPAIRS AND MAINTENANCE FAIR FUNDING: April 2002

Achieving Code Level Five with Concrete and Masonry

Garden Bothy, Cumnock

Module 3.7. Thermal bridging

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: MPRN:

Energy Performance Certificate

STEP-BY-STEP. construction guide. Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet.

Energy Performance Certificate

Delivering on innovation and market uptake. Best-in-cases of nzeb. Ramon Pascual Bucharest May 8th, 2015

FABRIC ENERGY EFFICIENCY FOR PART L 2013


BER Assessors Dwellings Technical Bulletin

Rosslare Case Study Passive House Cost Analysis. Seamus Mullins Quantity Surveyor Michael Bennett Group

14 October Home Ownership Services Islington Council Highbury House 4-5 Highbury Crescent London N5 1RN

Valuation Report. Property Address: Bristol. Date Inspected: 14 August 2013 CHARTERED SURVEYORS AUCTIONEERS VALUERS ESTATE AGENTS

HANLO The WELCOME HOME Experience.!! Simply better homes!!

Case Study: Wood Gasification Boiler Heating for an Exposed Rural Family Home Fuel cost assessment following thirty six months of operation

Multi-layer Insulation Blanket for Roofs

1..GENERAL DATA 2. CLIMATIC DATA. Location

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

Guide for home buyers

Dealing with damp and mould growth

Standards Committee T echnical Technical Conference

Rockwool Flexi Insulation Application Guide

TechPractices: Home Front Homes:

Council s energy efficiency upgrades benefit community

Capital Expenditure. The common definition of capital expenditure is

Sports Buildings: budget costs for the Flood Relief Fund

Energy Performance Certificate

Modular Accommodation Solutions. Flexibility, efficiency and quality in one complete package

Skanska Residential UK

HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS

Saint Cloud Business Center

Squash Court Design general points

IEA SHC Task 47 Renovation of Non-Residential Buildings towards Sustainable Standards

Site Survey Questionnaire

- 1 - Element Type. 9 mm gypsum board, 50 mm mineral wool (glued) 9 mm gypsum board, 50 mm mineral wool (on wooden studs, at 300 mm centres)

Building Condition Assessment: North Howard Street Baltimore, Maryland

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

School in Schwanenstadt, Austria

Post-insulation of cellar ceiling and cellar walls

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)

Extra Low Energy Housing in Ireland How far should we go to the Passive House? Jonathan Jennings Head of R&D Kingspan Century Homes

Code for Sustainable Homes Guidelines

Solving Persistent Moisture Problems and Moisture Damage

CASH SAVING BEATS ECO CONCERNS AS MAIN REASON TO GREEN YOUR HOME

Welcome to a warmer home. You could qualify for: Your guide to a gas supply and central heating system

New York, Dean. Price 182,500

Norwegian Tax Authority - Oslo Norway

rationel WINDOWS WITH VISION

Fall in love with your heating again. Reduce your heating bills with

St Andrews House. www. sowerbys.com. Guide Price 525,000

Build Back Smarter: House performance improvements at the time of earthquake repairs

London Borough of Redbridge

Park View Place. Compass. House. Royal Wharf Gardens Endeavour. House. Thameside. Sienna. House. House. Apartments Townhouses.

Building your Energy Efficient New Home

Building Condition Assessment Report

Prelease Schedule of Condition and Want of Repairs at Milton Keynes for May

Archant London Environmental Awards

Estimated Cost of Repair

2014 British Columbia Building Code Changes

Condensation. Some Causes, Some Advice

We care about. Environmentally-Friendly Building Products from Renewable Resources. natural building products. Product range overview

BYG DTU. Thermal properties of window frame Type 1 Sheet: 1. Type: Side, top and bottom profile. Source file: Format: dwg/dxf bmp

Challenging the possibilities

Asbestos in your home

Killeen Castle Gate Lodge Killeen Castle, Dunsany, Co Meath. For Sale by Private Treaty

PRESTRESSED CONCRETE FLOORING BEAMS

MEMORANDUM. General: Foundation:

MODERN HOME EXTENSIONS

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION

A Guide to... Home Renovation Incentive (HRI)

SIP (STRUCTURAL INSULATED PANEL)

Personal Tax Planning - What is a Resiliant or Resistance Measurement?

Management of Asbestos. Darren Arkins Senior Inspector Occupational Hygiene Unit Chemical Business Services Division

Green House, Hungary

Sapa Building System, first time at BAU

D Sample Notices to Property Owners, Sample Affidavits, and Other Material

Building Condition Assessment Report

PERMISSION A GUIDE FOR EXTENDING A DETACHED OR SEMI-DETACHED HOUSE

CONSTRUCTION COST GUIDE

REPAIR AND RENEW GRANT Guidelines and application form

Sub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders

Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: Purpose

Guide to Improving Your Home

Transcription:

Case Studies of Successful Code for Sustainable Homes Projects Sustainable Homes publish the Sustainable Homes Index For Tomorrow (SHIFT) and are a leading trainers of Code for Sustainable Homes assessors. These case studies are provided by members of SHIFT. www.sustainablehomes.co.uk info@sustainablehomes.co.uk

Case Study 1: Holt Road & Swans Close Norfolk Code Level 4 Developer Hastoe Housing Association A mixed development of 7, 2-3 bedroom houses and flats. This development was planned to Code Level 4 even before it was mandatory for housing associations to achieve this. Sustainable Design Features Ground source heat pump Passive solar design Low flow sanitary ware Rainwater recycling for garden Low energy lighting Internal recycling bins Positive enhancement of the site ecology www.sustainablehomes.co.uk Page 2

Technical Performance External Fabric Timber Frame with Facing Brickwork and Cavity fully insulated U-value 0.25W/m2K Roof Timber Frame with mineral wool insulation laid between & over ceiling joists U- value 0.11W/m2K Floor Proprietary Concrete Beam & Block with insulation & screed above. U value 0.16W/m2K Doors & Windows Double glazed, low-emissivity windows U-value of 1.8W/m2K and doors with a U-value of 1.20 W/m2K Air Permeability at 5.16m3/@50pa Cost and Value Additional costs were incurred in three specific areas: Landowner & Local Authority design requirements Features to achieve Code for Sustainable Homes Level 4 (absence of gas) Specific rural scheme requirements The total cost per sq metre excluding land and landowner s contribution to services was 1,619.86. Lessons Learnt As the first Code scheme for the design team, and the main contractor, some steep learning curves had to be accommodated Ensuring sub-contractors understood the requirements for Code Level 4 proved difficult especially when most were set in their ways Significant problems were encountered in obtaining responsibly sourced materials due to lack of interest from the supply chain to make it a high priority Surface water disposal proposals had to be continually re-examined to achieve compliance www.sustainablehomes.co.uk Page 3

Case Study 2: Mid Street Surrey Code Level 5 Developer Raven Housing Trust 2 Two bedroom flats located in South Nutfield. The first publicly funded social housing development in the UK to achieve Code Level 5 Sustainable Design Features Passive solar design Rainwater harvesting Environmentally friendly materials High levels of insulation low levels of air-permeability Low energy lighting Triple gazed windows MVHR Biomass pellet boiler Energy rated white goods www.sustainablehomes.co.uk Page 4

Technical Performance External Fabric Insulated panel system with 50mm external insulation value0.14w/m2k Roof Timber roof concrete tiles with 400mm mineral wood insulation U-value 0.13W/m2K Floor 75mm insulation U-value 0.14W/m2K Doors and windows U value 0.80W/m2K. Doors U-value of 1.2W/m2K Air Permeability 4.9m3/h@50pa Cost and Value Build cost excluding land costs and fees was c. 1,850 per sq metre. This was estimated to be an uplift of 20% over standard build costs. The biomass boiler presented the biggest source of problems requiring servicing every1-2 weeks significantly adding to maintenance costs. The sales value of the homes was estimated to be c. 2,857per sq metre, equal to or above sale values for equivalent properties in the area. Lessons Learnt It was important to involve an experienced code assessor before drafting initial designs Construction details need to be produced early in the design process Shared heating systems can be a practical and cost effective solution MVHR can significantly reduce energy requirements if correctly specified and installed A good relationship and understanding with the site manager is necessary for a design to be realised www.sustainablehomes.co.uk Page 5

Case Study 3: Jarvie Close - Hunstanton Code Level 4 Developer Hastoe Housing Association A development of 10 1-4 bedroom houses and flats Sustainable Design Features Ground source heat pumps Low energy light fittings Rainwater butts for garden Super insulation Passive solar design Low flow rated sanitary ware Recycling www.sustainablehomes.co.uk Page 6

Technical Performance External Fabric Cavity wall construction with facing brickwork, U- value 0.26W/m2k or 0.22W/m2k in areas finished with flint. Roof mineral wool insulation laid between and over ceiling joists U- value 0.13W/m2k Floor proprietary concrete beam & block with insulation & screed above -U-value 0.15W/m2K Doors & Windows Double glazed, low-emissivity windows U-value 1.8W/m2K and doors U-value of 1.20 W/m2K Air Permeability 3.59m3/@50pa Cost and Value Due to this scheme being classed as a Rural Exception Site there were specific design requirements that brought about additional costs. To achieve Code for Sustainable Homes Level 4 Ground Source Heat Pumps & Velfac glazed screens & windows for passive solar gain contributed 106,115 to the overall cost. The total cost per sq metre excluding land and landowner s contribution to services was 1,514.63. Lessons Leant Early consideration of Code issues enabled the design to be delivered that accommodated all of the Code requirements with relative ease An experienced contractor with a good understanding and previous experience of Code requirements further enabled easy delivery of a level 4 scheme Using a Code Assessor and working with them from the start helped to iron out problems during construction www.sustainablehomes.co.uk Page 7