APC Step-Down Transformer. User s Manual



Similar documents
Triple Expansion Chassis

How To Install A Power Supply (Uplast) With A Battery Pack

BroadBand PowerShield. User Manual

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Out-of-Band Management Card

HP UPS R1500 Generation 3

Installation Guide Smart-UPS X External Battery Pack SMX120BP

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

750VA/1000VA/1500VA 100/120/230VAC 2U

User Manual. English. APC Smart-UPS VA 120/230 Vac VA 100/120/208/230 Vac. 2U Rack Mount Uninterruptible Power Supply

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

Installation Guide Smart-UPS X Tower/Rack-Mount 2U 2000/2200/3000 VA

APC Smart-UPS 2400/3000 VA 100/ VAC 3U. Uninterruptible Power Supply

User Manual. English. APC Smart-UPS RT. 3000/5000/6000 VA VAC Tower/Rack Mount 3U Uninterruptible Power Supply

User Manual. English. APC Smart-UPS RT. 8000/10000 VA Vac Tower/Rack-Mount 6U Uninterruptible Power Supply

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

Installation and Operation

Installation. Basic Rack Power Distribution Unit AP9559

, User s Manual

HP R12000 and R18000 DirectFlow UPS User Guide

Advantium 2 Plus Alarm

QuickSpecs. HP Modular Power Distribution Units (Zero-U/1U Modular PDUs) Overview

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

User Manual. Smart-UPS. Uninterruptible Power Supply 750/1000/1500 VA. 100/120/230 Vac. Rack Mount 2U

CAUTION. CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or moderate injury.

User Manual. Smart-UPS TM C. Uninterruptible Power Supply SRC250 SRC /120/230 Vac. Tower/Rack-Mount 1U

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

12-Volt 10-Amp Regulated Power Supply

Metered Rack Power Distribution Unit

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

MCR1900 Media Converter 19-Slot Chassis

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

QuickSpecs. HP 480/277 Volt Solutions. Overview

Refer installation of power supplies to qualified service personnel.

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

Unpacking, Installation, and Customization

Installation and Operation Guide PD4600 Series Converter Replacement

PEDAL POWER. User s Manual

HP SATA/SAS hard drive and Solid State Drive installation

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

ATS Overhead Table Shelf System INSTRUCTION MANUAL

42U/45U 28" Wide Rack Installation & Service Guide

Back-UPS Pro 1300/1500 Installation and Operation

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

Installation and Operation Back-UPS 1250, 1300, 1500

Powerware Relay-Serial Card User s Guide

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion

Rack Installation Instructions

How To Test A Power Distribution Unit

16/32 Channel 1U Rack Mount CCTV Power Supply

3-4 SAS/SATA II HDD Canister Deluxe version

About the HotWire Slot Standalone Shelf

HP Port Switches Quick Setup Guide

PS6500 Storage Arrays Rack Mount Instructions

i410/i1010 AC/DC Current Clamp

StorTrends 3400 Hardware Guide for Onsite Support

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

esata External Storage

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

HotSwap MBP Maintenance Bypass

Remote Alarm Monitoring System

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

INSTRUCTION MANUAL MODEL PCD-88

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

P O W E R S U P P L Y M A N U A L

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

Smart-UPS On-Line 230 V

How to Set Up Your NSM4000 Appliance

Ceiling Mount Air Handler Manual

QNAP RAID Expansion Enclosure Hardware User Manual QNAP Systems, Inc. All Rights Reserved.

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

EKOS Cart. Instructions for Use

About Your NetBotz 4-20mA Sensor Pod

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Installation and Operation

Operation Manual. Smart-UPS UPS. 750/1000/1500/2200 VA Rack-mount 2U 120/230 VAC VA Rack-mount 2U 120/208/230 VAC

Installation and Operation Guide for PD5100 Automatic Transfer Switch

Architect/Contractor Information Package

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

Model #: SMART2200CRMXL

AXIS T81B22 DC 30W Midspan

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

POWER GEAR SLIDE OUT MANUAL

Bubble King. User Manual

Rack installation instructions

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

±15 V Current-Limited Power Supply

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

User s Manual Before using the inverter, you need to read and save the safety instructions.

LIEBERT VNSA Installation Sheet

About this Manual. Support for Your Product

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

Single Station Remote Alarm

Transcription:

APC Step-Down Transformer Models: AP9621, SURT005, SURT006, SUTF3, SYTF2, SYTF2J, SYTF3 and SYTF3J User s Manual English 990-7820D, July 2003

TABLE OF CONTENTS APC Contact Numbers and Support Visit the APC Web site for contact numbers and support at http://www.apc.com/support. Chapter 1: Safety and General Information...1 Save These Instructions... 1 Conventions Used in this Manual... 1 Handling Safety... 1 De-energizing Safety... 2 Electrical Safety... 2 Regulatory Agency Approvals... 2 Life Support Policy... 3 Limited Warranty... 3 Copyright and Trademark Information... 3 Chapter 2: Basics...5 About Your Step-Down Transformer... 5 Product Overview... 6 Front View Component Identification... 7 Rear View Component Identification... 7 Chapter 3: Installation...7 Unpacking... 8 Inspection... 8 Contents... 8 Installing the Step-Down Transformer... 8 Installing in a Four-Post Rack... 8 Wiring the Step-Down Transformer... 9 Connecting Load Equipment... 10 Turning On the Step-Down Transformer... 10 Using the Step-Down Transformer... 11 Chapter 4: Specifications... 11 Product Specifications... 12

TABLE OF CONTENTS

CHAPTER 1: SAFETY AND GENERAL INFORMATION Save These Instructions This Safety section contains important instructions that must be followed during installation and maintenance of APC equipment. Conventions Used in this Manual The following symbols are used throughout this manual. Carefully read all information boxes and abide by the instructions. The WARNING sign denotes a serious hazard. It calls attention to a procedure, practice, condition, or the like, which, if not correctly performed or adhered to, could result in injury to personnel. The CAUTION sign denotes a hazard. It calls attention to an operating procedure, practice, or the like, which, if not correctly performed or adhered to, could result in damage to or destruction of all or part of the product. The NOTE sign denotes important information. It calls attention to a procedure, practice, condition, or the like, which is essential to highlight. Handling Safety Be careful. Do not lift heavy loads without assistance. 32 55 kg (70 120 lb) This equipment is intended for installation in a temperature-controlled indoor area free of conductive contaminants. Refer to Specifications at the APC web site (www.apc.com/support/) for the actual temperature range. 1

CHAPTER 1: SAFETY AND GENERAL INFORMATION De-energizing Safety To de-energize this equipment toggle the rear input circuit breaker to the OFF position, and then disconnect the equipment from the AC power outlet. Electrical Safety The protective earth conductor carries the leakage current from the load devices (computer equipment). Therefore, the size of the conductor must be at least as large as the wire required by IEC 950. An insulated grounding conductor that is identical in size, insulation material, and thickness to the grounded and ungrounded branch-circuit supply conductors, except that it is green with or without a yellow stripe is to be installed as part of the branch. The grounding conductor described above is to be grounded to earth at the service equipment, or if supplied by a separately derived system, at the supply transformer or motorgenerator set. The attachment-plug receptacles near the unit or subsystem are all to be of a grounding type, and the grounding conductors serving these receptacles are to be connected to earth ground at the service equipment. To reduce the risk of fire, connect only to a circuit provided with 30-amp maximum branch circuit overcurrent protection in accordance with the National Electrical Code, ANSI/NFPA. Regulatory Agency Approvals Regulatory Agency Symbols LISTED 42C2 E95463 LR63938 2

CHAPTER 1: SAFETY AND GENERAL INFORMATION Life Support Policy As a general policy, American Power Conversion (APC) does not recommend the use of any of its products in life support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness. APC does not recommend the use of any of its products in direct patient care. APC will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC that (a) the risks of injury or damage have been minimized, (b) the customer assumes all such risks, and (c) the liability of American Power Conversion is adequately protected under the circumstances. Examples of devices considered to be life support devices are neonatal oxygen analyzers, nerve stimulators (whether used for anesthesia, pain relief, or other purposes), autotransfusion devices, blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, hemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators for both adults and infants, anesthesia ventilators, infusion pumps, and any other device designated as critical by the U.S.F.D.A. Hospital grade wiring devices and reduced leakage currents that meet medical safety standards may be ordered as options on many APC UPS systems. APC does not claim that units with these modifications are certified or listed as such by APC or any other organization, therefore these units do not meet the requirements for use in direct patient care. Limited Warranty American Power Conversion (APC) warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase, except in India where the period is one year for battery module(s). Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. To obtain service under warranty you must obtain a returned material authorization (RMA) number from customer support. Products must be returned with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase. This warranty does not apply to equipment that has been damaged by accident, negligence, or misapplication or has been altered or modified in any way. This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase. EXCEPT AS PROVIDED HEREIN, AMERICAN POWER CONVERSION MAKES NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser. EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL APC BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, APC is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise. This warranty gives you specific legal rights and you may have other rights that vary from state to state. Copyright and Trademark Information Entire contents copyright 2003 by American Power Conversion Corporation. All rights reserved. Reproduction in whole or in part without permission is prohibited. APC, Symmetra, Smart-UPS, Smart-UPS RT, NetShelter, InfraStruXure and PowerChute are registered trademarks of American Power Conversion Corporation. All other trademarks are the property of their respective owners 3

CHAPTER 1: SAFETY AND GENERAL INFORMATION 4

CHAPTER 3: INSTALLATION About Your Step-Down Transformer Figure 1: Step-Down Transformer This Step-Down Transformer is designed for use with a UPS that provides a higher output voltage (200 or 208 VAC). It converts the output to a lower voltage (100 or 120 VAC); a common voltage level used by many computers and accessories. The Step-Down Transformer may also be used as a stand-alone device. Table 1: System Configurations and Model Numbers North America and 208V (Ø- Ø -G) Japan and 200 V (Ø- Ø -G) Complete System End Item SKU AP9621, SYTF2, SURT005 SYTF3, SUTF3 SYTF2J, SURT006 Available Power VA 4500* 5000** Nominal Input Voltage VAC Nominal Output Voltage VAC * Power cord connected units have an available power of 4500 VA with a L6-30 plug. ** Units with an available power of 5000 VA must be hardwired due to input current. *** Ensure that the pin number for T-slot receptacles is correct. Frequency Hz Power Distribution 208 120 60 Input: 3-foot cord with L6-30P or hardwired. *** Output: (2) 15-amp circuits with (4) 5-20R T-slots and (2) 15-amp circuits with (2) 5-20R T-slots, or hardwired. 4500 208 120 60 Input: 2-foot cord with L6-30P. *** Output: (4) 20-amp circuits with (4) L5-20R. 3500 200 100 50 or 60 Input: 3-foot cord with L6-30P. ***Output: (2) 15-amp circuits with (4) 5-20R T-slots and (2) 15-amp circuits with (2) 5-20R T-slots. SYTF3J 3500 200 100 50 or 60 Input: 2-foot cord with L6-30P. ***Output: (4) 20-amp circuits with (4) L5-20R. 5

CHAPTER 3: INSTALLATION Product Overview 6

Front View Component Identification CHAPTER 3: INSTALLATION Rail Cleats ❶: Two cleats (one on each side) of the Step-Down Transformer engage with the rack mounting rails to secure in the equipment rack. Figure 2: AP9621 Mounting Flanges ❷: Two mounting flanges (Figure 2 and 4) secure the Step-Down Transformer in the rack. Front Bezel ❸: A bezel covers the front of the Step- Down Transformer. The bezel is removed during the installation for the SUTF3, SYTF2, SYTF2J, SYTF3 and SYTF3J models. Fans ❹: Two fans on the front of the Step-Down transformer circulate airflow and cool the unit. The redundant fan will not operate unless the internal temperature of the unit becomes 100 F or failure of the main cooling fan. Figure 3: SUTF3 / SYTF2 / SYTF2J / SYTF3 / SYTF3J Figure 7: SUTF3 / SYTF2 / SYTF2J / SYTF3 / SYTF3J / SURT005 / SURT006 Figure 4: SURT005/ SURT006 Rear View Component Identification Figure 5: AP9621 / SYTF2 / SYTF2J / SURT005 / SURT006 Input Wiring ❶: Provides access to wiring terminal blocks for hard wiring the input (see Figure 6). Provided with an input cord for use in many applications (see Figure 7). Input Circuit Breaker ❷: The input circuit breaker protects the product and load equipment from extreme overloads. Power Distribution Unit (PDU) ❸: Power distribution receptacles for connecting load equipment. Figure 6: SUTF3 / SYTF3 / SYTF3J 7

CHAPTER 3: INSTALLATION Unpacking The Step-Down Transformer is packaged in a robust shipping carton. Carefully remove the package contents. The packaging is recyclable; save it for reuse or dispose of it properly. Inspection Inspect the equipment upon receipt. APC has designed robust packaging for your product. However, accidents and damage may occur during shipment. Notify the carrier and dealer if there is damage or missing equipment. Contents Check the packaging contents. The shipping package contains the Step-Down Transformer, mounting rails, and mounting hardware. Your package may contain a Bezel Kit. If the bezel is not already installed, snap it on to the UPS as instructed below. Installing the Step-Down Transformer This section provides information on the steps required to install and connect the Step-Down Transformer. Installing in a Four-Post Rack Follow the instructions contained in the Addendum SU Rack-Mount Rails 2U-5U sheet (990-7034G) to mount the rails in your NetShelter or 19 in (46.5 cm) rack. *It is recommended that the Step-Down Transformer is installed directly above the UPS in the rack. 1. Install the mounting rails using the instructions contained in the Rail Kit. 2. Slide the Step-Down Transformer frame into the rack. The Step-Down Transformer is heavy. Three people must support the unit. Figure 8: AP9621 / SURT005 / SURT006 3. To secure the Step-Down Transformer frame in the rack, screw the four decorative screws through the holes in the ears of the UPS and into the screw clips. 4. If the bezel has not already been attached, align the tabs on the sides of the bezel with the slots on the front of the Step-Down Transformer and gently snap it into place. Figure 9: SUTF3 / SYTF2 / SYTF2J / SYTF3 / SYTF3J Install the bezel with the rear fins facing down. 8

Wiring the Step-Down Transformer CHAPTER 3: INSTALLATION 1. For cord connected installations, plug the input power cord ❶ into the outlet ❷. 2. For hardwired installations: Verify that all branch circuit (mains) are de-energized and locked out before installing cables or making connections. Wiring by a licensed electrician is required. Check national and local codes before wiring. Use 10-gauge (6 mm 2 ) wire. 3. Make sure the input circuit breaker ❸ is OFF. a. Remove the input-wiring access panel ❹. b. Disconnect the power cord from terminal block ❺. c. Connect the new wires ❻ to the terminal block. d. Each terminal is labeled. The Step-Down Transformer requires a 208 VAC single-phase input from a power source with a minimum branch breaker rating of 30-amps. e. Inspect the connections. f. Attach the new access panel ❼ provided in the literature kit. 9

CHAPTER 3: INSTALLATION Connecting Load Equipment Plug all load equipment into PDU ❶ receptacles. For AP9621, SYTF2, SYTF2J, SURT005, and SURT006 models, the receptacles are divided into 4 groups; each group is protected by a 15-amp circuit breaker. A colored label identifies each circuit and its circuit breaker. For SUTF3, SYTF3 and SYTF3J models, the output is divided into 4 groups. Each group is protected by a 20-amp circuit breaker that contains one (1) receptacle. When connecting the equipment, distribute the loads evenly on the four output circuits. Turning On the Step-Down Transformer 1. Turn on the Step-Down Transformer by switching the rear panel input circuit breaker ❶ to the ON position. For AP9621, SYTF2, SYTF2J, SURT005, and SURT006 models, a colored label identifies each circuit and its circuit breaker. 2. Turn on all connected equipment. Depending on your required output power, one of the fans may not be turning because the internal temperature of the Step-Down Transformer is less than 100 F. If 100 F is reached, the redundant fan will turn on. 10

Using the Step-Down Transformer CHAPTER 3: INSTALLATION Connect the Step-Down Transformer to a UPS for continuous power during a utility power failure. The transformer has an efficiency of 90%. This requires 5500 VA for a 5000 VA load, 5000 VA for a 4500 VA load, and 3900 VA for a 3500 VA load. Be careful not to overload your branch circuit or UPS. For the AP9621, SYTF2, and SURT005 models to output the full 5000 VA, the input must be hardwired to a 5500 VA source. Operating the Step-Down Transformer below its specified input voltage range may cause it to overload and shut down to prevent it from over-heating. When connecting directly to a branch circuit, ensure that the line voltage is within specification. When connecting to a UPS, ensure that the line voltage into the UPS is within specification before transferring to bypass. Operating the Step-Down Transformer above its input voltage range may cause equipment damage. 11

CHAPTER 4: SPECIFICATIONS Product Specifications Electrical Specifications AP9621 / SUTF3 / SYTF2 / SYTF3 / SURT005 Nominal Input Voltage (VAC) 208 200 Input Voltage Range (VAC) 185 to 230* 180 to 220 Maximum Input Current (amps) Line cord Installation (L6-30) 24 22 Hardwire Installation 26** Line Frequency (Hz) 60 50 or 60 Efficiency 90 to 95% Nominal Output Voltage (VAC) 120 100 SYTF2J / SYTF3J / SURT006 Maximum Output Power (VA) Line cord Installation (L6-30) Hardwire Installation 4500* 5000* 3500 3500 * For continuous operation below Vin = 205 VAC, the output load must be reduced to limit the maximum input current to the amount specified in the table above. Continuous operation above the maximum specified input current may cause the unit to overheat and shutdown. Please contact APC for additional information. ** Not available on SUTF3 and SYTF3 models. 12

CHAPTER 4: SPECIFICATIONS Dimensions (H x W x D) (Overall) Weight Net Shipping Temperature Operating Storage Other Specifications 3.5 in x 19 in x 26 in (with bezel) (8.9 cm x 48.3 cm x 66 cm) 95 lbs (43kg) 110 lbs (50 kg) 0 to 40 C 25 to 65 C Humidity, relative Operating and storage 5 to 95% Elevation Operating 0 to +3,000 m (0 to +10,000 ft) Storage 0 to +15,000 m (0 to +50,000 ft) Agency Approvals UL 1778 (AP9621, SUTF3, SYTF2, SYTF2J, SYTF3, SYTF3J, SURT005, and SURT006 models) CSA 66 (AP9621, SUTF3, SYTF2, and SYTF3 models) 13