REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion
|
|
|
- Edward Wright
- 9 years ago
- Views:
Transcription
1 REDI-LINE ELECTRIC GENERATORS USER'S GUIDE Rugged, Reliable, DC to AC Power Conversion
2 REDI-LINE ELECTRIC GENERATOR MODEL INPUT ACTUAL OUTPUT ACTUAL OUTPUT WATTS SERIAL NO. PACIFIC SCIENTIFIC MOTOR PRODUCTS DIVISION ROCKFORD, IL Fill in Data for your permanent records. The model and electrical data will be found on the body nameplate. Due to certain mounting applications, this data may become obstructed. You should record information and keep in a safe place for future reference. Table of Contents Page Function... 2 Features... 2 Specifications... 2 Unpacking & Insertions... 3 Installation Requirements Wiring Installation Maintenance Service Warranty Mounting Templates Kishwaukee Street P.O. Box 106 Rockford, IL (815) Fax (815)
3 User s Guide REDI-LINE Electric Generator CAUTION The is a quality product, designed to be rugged, reliable and safe when installed properly. Improper installation can cause damage to the unit and/or result in serious personal injury. Read this entire manual before starting installation. If you have questions on installation or operation of the generator, contact your REDI-LINE distributor for assistance. If you do not have a distributor contact, call Pacific Scientific direct at (815) Function The is an electromechanical device that converts DC to AC. The DC supply is one or more deep cycle batteries that are typically added to the electrical system of your vehicle. Convenient, remote operation of most tools, appliances and lighting is assured as long as their power consumption is within the nameplate rating of the generator. Your REDI-LINE generator is designed to supply true sine-wave electrical power for years of trouble free service. 2. Features Built rugged and reliable with sturdy steel housing. Two year warranty. Patented Demand Start Circuitry extends battery life. Easily delivers peak output currents up to 1.5 times the continuous output rating for extra starting power. Conveniently mounts in any position in a minimum of space. True sine-wave output. Optional GFI outlet. Operates in ambient temperatures from -30 F to 130 F. 3. Specifications DA12L-1600A Models DA12A-500A DA12L-1600A-GFI DA24A-800A DA24L-1600A DA36A-900A DA36L-1600A Input Voltage (DC) Nominal Input Voltage (DC) Continuous Output Watts Surge Output Watts Output Voltage* (AC) Output Frequency (Hz) Continuous Output Current Surge Output Current (Amps) Wave Shape Sine Sine Sine Sine Sine Sine Length (inches) Height (inches) Diameter (inches) Weight (lbs.) Ambient Temperature Range, all models: -30 to 130 F (-34 to 54 C) Models DA3179 DA3252 DA3272 DA3444 Input Voltage (DC) Nominal Input Voltage (DC) Continuous Output Watts Surge Output Watts Output Voltage* (AC) Output Frequency (Hz) Continuous Output Current Surge Output Current (Amps) Wave Shape Sine Sine Sine Sine Length (cm) Height (cm) Diameter (cm) Weight (kg) Ambient Temperature Range, all models: -30 to 130 F (-34 to 54 C) * Variance from output voltage and frequency is dependent on load size and the DC input voltage. Typical voltage tolerance is ±15%. Typical frequency tolerance is ±5%. Carefully monitor any equipment that is sensitive to fluctuations in either voltage or frequency. 2
4 4. Unpacking and Inspection Open the top of the box and lift the Generator and the CAUTION insert out. This generator is a heavy piece of equipment. Removing it from the box may require more than one person to avoid dropping the generator and prevent personal injury. Inspect the unit for any damage that may have been sustained during shipment. If you find damage, contact the shipper immediately to file a claim. 5. Installation Requirements Most REDI-LINE service requests result from improperly installed units. Improper installation will affect generator performance and may damage the unit. Generator damage caused by improper installation is not covered under warranty. Selection Standard automotive batteries are designed to supply 300 to 500 amps of current over a relatively short period, therefore, they are not the best power source for generator operation. Deep cycle or marine batteries are designed to deliver lower current levels for a longer time and are capable of taking deep discharges without battery damage. For this reason, a deep cycle battery is recommended for REDI-LINE operation. Batteries are rated in cold cranking amps (CCA). In general, the higher the CCA the longer the battery will operate a generator load. Length of run time depends on the battery capacity, the size of the load (tool or appliance connected to the generator), and how frequent the load is operated. Use the following formula to estimate how long a fully charged deep cycle battery will keep the REDI-LINE operating continuously before the battery needs recharging: Hours = Cold Cranking Amps (CCA) 180 x AC Load Amps Cold Cranking Amps are equal to the total of all batteries. AC Load Amps is the AC current rating listed on the nameplate of the tool or appliance. For Example: Two batteries with a CCA rating of 675 are used to operate a Generator. An AC load of 4 amps is required by the tool being operated. Continuous run time is: Hours = = 1.87 Hours 180 x 4 further extend the operating time of the generator, the generator's battery system should be connected to the vehicle charging system. With the vehicle running, the alternator charges the generator battery bank which provides a longer run time. If you plan to use the generator continuously, you may need to install a larger alternator in your vehicle. Consult your REDI-LINE distributor for more 3 information. NOTE: Installation and wiring must conform to all applicable codes, including the National Electric Code, state and local, or other codes in effect at the time of installation. CAUTION Automotive and marine type batteries produce dangerous current levels. Protect yourself when working around these batteries and electrical systems. This includes the use of safety goggles. Mounting Guidelines After reviewing your generator usage and selecting the battery size and number of batteries, determine the best location to mount your generator and its power supply. When choosing a location, observe these guidelines: Keep the generator as close to the battery as possible to reduce the length of the power cables. Long power cables will reduce the amount of voltage to the generator and decrease performance. Allow at least 2 inches of free air space around the generator. Do not obstruct the ventilation as it can cause the CAUTION generator to overheat. Do not install the generator in areas with direct exposure to water, or compartments containing batteries CAUTION or explosive fumes. Do not install in unventilated areas where ignitable fumes can collect. Mounting the Generator The generator is not position sensitive and may be mounted in whatever orientation best suits your application. Place the unit in the desired position or use the templates on pages to mark the location of the mounting holes. Remove the generator or template. At the marked location, drill 1/4" holes and fasten the generator using four 1/4 flat washers, lock washers, bolts, and nuts through the holes in the base flange. Installation Wiring Install additional batteries, fuses, and, if required, a battery isolator. See Installation Illustrations (pages 5-11) for specific instructions. Cable, connectors, fuses and isolators may be available from your authorized REDI-LINE distributor. Many also provide complete installation services. Pacific Scientific recommends that the REDI-LINE Generator always be installed using proper fuses or circuit breakers. See the Installation Illustrations for suggested fuse sizes and location. Place fuses no farther than 18 from the battery. WARNING It is important that the polarity ( & -) be correctly connected to the generator. Note polarity indications on Installation Diagrams shown in this guide.
5 The connection between the supply battery and the REDI- LINE Generator is one of the most critical installation steps. Choose the correct supply cable size from the following table. Using the wrong supply cable size will damage the generator. Do not ground the negative (-) REDI-LINE supply terminal to the vehicle chassis. The negative REDI-LINE terminal must be connected directly to the supply battery using the proper size supply cable. Recommended Supply Cable Size For Cable Length in Feet Generator up to 3 3 to 8 8 to & over DA3179 DA12A-500A #6 #4 #4 #4 DA24A-800A DA3272 #6 #6 #6 #4 DA36A-900A DA12L-1600A* & DA32526 #2* #2* #2* #0* DA24L-1600A DA3444 & #6 #6 #6 #4 DA A Between and Less than 10 ft. #0 AWG Cable. More than 10 ft. #00 AWG Cable. *Recommended minimum wire gauge for DA12L-1600A & DA3252 with one battery. NOTE: Damage caused by incorrectly installing your REDI-LINE generator is not covered by warranty. Carefully plan the power supply cable route. Do not allow the cables to rub against sharp surfaces which could cut the cable insulation and cause a short against the vehicle frame. NOTE: When attaching the power cables to the generator, a spark at the connection may occur. This is normal and does not mean the generator is defective. The REDI-LINE generator will not run until the demand start circuit senses a load. turn on the generator plug a load into the generator receptacle and turn on the device switch. The generator should start. After the AC load is removed the generator will stop in 2 to 10 seconds. If the generator does not start, or cycles on and off, the AC load may be too small or the AC device may not be turned on. Verify the device is turned on or try adding more load to the generator. 4
6 Recommended Wiring Installation DA12A-500A and DA3179 Infrequent Use with Varying Loads If the load requirement is not heavy (intermittent hand tool use or light loads for a long period of time) the vehicle battery and charging system should handle both vehicle and additional generator demand. 75 Amp Vehicle Frequent Use with Varying Loads 75 Amp If the load requirements are heavy (constant use of hand tools or large loads) install one or more auxiliary deep cycle batteries. The auxiliary battery should be isolated from the vehicle battery using a battery isolator. The battery isolator is a one way path so both batteries are charged by the vehicle but one battery cannot discharge the other. This will ensure the vehicle battery is always charged and you will be able to start your vehicle. Isolator* Auxiliary Vehicle 5 Isolator The Alternator *Use fuse size recommended by isolator manufacturer
7 Recommended Wiring Installation DA12L-1600A and DA 3252 Infrequent Use with Varying Loads 200 Amp Jumper Cables If the load requirement is not heavy (intermittent hand tool use or light loads for a long period of time) install one or more auxiliary deep cycle batteries. The auxiliary battery should be isolated from the vehicle battery using a battery isolator. The battery isolator is a one way path so both batteries are charged by the vehicle but one battery cannot discharge the other. This will ensure the vehicle battery is always charged and you will be able to start your vehicle. Isolator* Isolator The Alternator Frequent Use with Varying Loads 100 Amp 100 Amp Jumper Cables If the load requirements are heavy (constant use of hand tools or large loads) install two or more auxiliary deep cycle batteries. The auxiliary batteries should be isolated from the vehicle battery using a battery isolator. The battery isolator is a one way path so both batteries are charged by the vehicle but one battery cannot discharge the other. This will ensure the vehicle battery is always charged and you will be able to start your vehicle. Isolator* Isolator* Isolator The Alternator *Use fuse size recommended by isolator manufacturer 6
8 Recommended Wiring Installation DA24A-800A and DA3272 Infrequent Use with Varying Loads 50 Amp If the load requirement is not heavy (intermittent hand tool use or light loads for a long period of time) the vehicle battery and charging system should handle both the vehicle and additional generator demand. Vehicle Batteries Frequent Use with Varying Loads 50 Amp If the load requirements are heavy (constant use of hand tools or large loads) install two or more deep cycle auxiliary batteries. The auxiliary battery should be isolated from the vehicle battery using a battery isolator. The battery isolator is a one way path so both batteries are charged by the vehicle but one battery cannot discharge the other. This will ensure the vehicle battery is always charged and you will be able to start your vehicle. Auxiliary Batteries Isolator* Vehicle Batteries Isolator The Alternator 7 *Use fuse size recommended by isolator manufacturer
9 Recommended Wiring Installation DA24L-1600A and DA3444 Infrequent Use with Varying Loads 100 Amp If the load requirement is not heavy (intermittent hand tool use or light loads for a long period of time) the vehicle battery and charging system should handle both the vehicle and additional generator demand. Vehicle Batteries Frequent Use with Varying Loads 100 Amp If the load requirements are heavy (constant use of hand tools or large loads) install two or more deep cycle auxiliary batteries. The auxiliary battery should be isolated from the vehicle battery using a battery isolator. The battery isolator is a one way path so both batteries are charged by the vehicle but one battery cannot discharge the other. This will ensure the vehicle battery is always charged and you will be able to start your vehicle. Auxiliary Batteries Isolator* Vehicle Batteries Isolator The Alternator *Use fuse size recommended by isolator manufacturer 8
10 Recommended Wiring Installation DA36-900A Infrequent Use with Varying Loads 50 Amp If the load requirement is not heavy (intermittent hand tool use or light loads for a long period of time) the vehicle battery and charging system should handle both the vehicle and additional generator demand. Vehicle Batteries Frequent Use with Varying Loads 50 Amp If the load requirements are heavy (constant use of hand tools or large loads) install two or more auxiliary deep cycle batteries. The auxiliary batteries should be isolated from the vehicle battery using a battery isolator. The battery isolator is a one way path so both batteries are charged by the vehicle but one battery cannot discharge the other. This will ensure the vehicle battery is always charged and you will be able to start your vehicle. Auxiliary Batteries Isolator* Vehicle Batteries Isolator The Alternator 9 *Use fuse size recommended by isolator manufacturer
11 Recommended Wiring Installation DA36L-1600A Infrequent Use with Varying Loads 100 Amp If the load requirement is not heavy (intermittent hand tool use or light loads for a long period of time) the vehicle battery and charging system should handle both the vehicle and additional generator demand. Vehicle Batteries Frequent Use with Varying Loads 100 Amp If the load requirements are heavy (constant use of hand tools or large loads) install two or more auxiliary deep cycle batteries. The auxiliary batteries should be isolated from the vehicle battery using a battery isolator. The battery isolator is a one way path so both batteries are charged by the vehicle but one battery cannot discharge the other. This will ensure the vehicle battery is always charged and you will be able to start your vehicle. Auxiliary Batteries Isolator* Vehicle Batteries Isolator The Alternator *Use fuse size recommended by isolator manufacturer 10
12 6. Maintenance Because the REDI-LINE generator contains long life bearings and brushes, it is virtually maintenance free. A periodic wipe down of the unit and inspection of all mounting hardware for tightness is all that is needed. Cable and battery connections should also be inspected regularly. 7. Service If your should need service, contact your nearest authorized REDI-LINE distributor. obtain the location of your nearest REDI-LINE distributor, contact Pacific Scientific at Warranty Pacific Scientific warranties its Product(s) to the original purchaser the Customer, and in the case of original equipment manufacturers or distributors to their original consumer the Customer to be free from defects in material and workmanship and to be made in accordance with Customer s specifications which have been accepted in writing by Pacific Scientific. In no event, however, shall Pacific Scientific be liable or have any responsibility under such warranty if the Products have been improperly stored, installed, used or maintained, or if Customer has permitted any unauthorized modifications, adjustments and/or repairs to such Products. Pacific Scientific s obligation is limited solely to repairing or replacing (at its option), at its approved repair facility, any Products, or parts which prove to Pacific Scientific s satisfaction to be defective as a result of defective materials or workmanship, in accordance with Pacific Scientific s stated warranty, provided, however, that written notice of claimed defects shall have been given to Pacific Scientific within two (2) years after the date of the product date code that is affixed to the Product, and within thirty (30) days from the date any such defect is first discovered. The Products or parts claimed to be defective must be returned to Pacific Scientific, or an Authorized Redi-Line distributor, transportation prepaid by customer, with written specifications of the claimed defect. Evidence acceptable to Pacific Scientific must be furnished that the claimed defects were not caused by misuse, abuse, or neglect by anyone other than Pacific Scientific. BREACH OF CONTRACT, NEGLIGENCE, STRICT LIABILITY, TORT WARRANTY, PATENT OR COPYRIGHT INFRINGEMENT, SHALL NOT EXCEED THE PRICE SPECIFIED OF THE PRODUCTS GIVING RISE TO THE CLAIM, AND IN NO EVENT SHALL PACIFIC SCIENTIFIC BE LIABLE UNDER THESE WARRANTIES OR OTHERWISE, EVEN IF PACIFIC SCIENTIFIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, DAMAGE OR LOSS RESULTING FROM INABILITY TO USE THE PRODUCTS, INCREASED OPERATING COSTS RESULTING FROM A LOSS OF THE PRODUCTS, LOSS OF ANTICIPATED PROFITS, OR OTHER SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER SIMILAR OR DISSIMILAR, OF ANY NATURE ARISING OR RESULTING FROM THE PURCHASE, INSTALLATION, REMOVAL, REPAIR, OPERATION, USE OR BREAKDOWN OF THE PRODUCTS, OR ANY OTHER CAUSE WHATSOEVER, INCLUDING PACIFIC SCIENTIFIC S NEGLIGENCE. The forgoing shall also apply to Products, or parts for the same which have been repaired or replaced pursuant to such warranty. No person,including any agent, distributor, or representative of Pacific Scientific, is authorized to make any representation or warranty on behalf of Pacific Scientific concerning any Products manufactured by Pacific Scientific, except to refer purchasers to this warranty. THE FOREGOING WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES (EXCEPT AS TO TITLE), WHETHER EXPRESSED OR IMPLIED, INCLUDING WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR ANY PARTICULAR PURPOSE, AND ARE IN LIEU OF ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF PACIFIC SCIENTIFIC. PACIFIC SCIENTIFIC S MAXIMUM LIABILITY WITH RESPECT TO THESE WARRANTIES, ARISING FROM ANY CAUSE WHATSOEVER, INCLUDING WITHOUT LIMITATION, 11
13 DAI2A, DA24A, DA36A, DA3179 and DA3272 Mounting ± X X ± All measurements in inches. 12
14 DAI2L, DA24L, DA36L, DA3252 and DA3444 Mounting All measurements in inches. 13
15 WARRANTY REGISTRATION NAME ADDRESS PHONE ( ) CITY STATE ZIP Where did you purchase your? Name of Business ADDRESS Model # Purchase date Generator application area: Medical RV Marine Construction Cable TV Agriculture Utility Co. Consumer Other How did you learn about the? magazine ad previously owned one newspaper ad salesperson friend store demonstration exhibit show other What device will the generator power primarily? Thank you for your time in filling out this warranty card. PACIFIC SCIENTIFIC MOTOR PRODUCTS DIVISION
16 4301 Kishwaukee Street P.O. Box 106 Rockford, Illinois (815) Fax (815) JL M PRINTED IN U.S.A. PK91282 LOCATIONS: Rockford, IL Wilmington, MA Ennis, Ireland
WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL
WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL CAUTION: This system is not for use with antenna in raised position while
6 & 12 Volt Battery and Systems Tester with 100 Amp Load
6 & 12 Volt Battery and Systems Tester with 100 Amp Load Form No. 841-731 -000 DESCRIPTION This Load Tester tests 6 or 12 volt automotive-size lead-acid batteries under load. It will also test 6 or 12
3000W Power Inverter
3000W Power Inverter OWNER S MANUAL Model number-4573000 TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND THIS INSTRUCTIONAL MANUAL. THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THE
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide circuit. Reverse connection will damage the module and may result in fire. CAUTIONS Solar electric modules produce DC electricity
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.
*00151* FEATURES Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate. Silicon diodes with inherent surge protection operated at a conservative
Instructions & Safety Information Models A220-20D and A220-20L Version 2
Quick 220 Voltage Converting Power Supply Instructions & Safety Information Models A220-20D and A220-20L Version 2 Quick 220 Systems LLC PO Box 47489 Phoenix, Arizona 85068-7489 800-347-0394 602-938-6057
Installation and Operation Guide for PD4100 Series Power Control Centers
Installation and Operation Guide for PD4100 Series Power Control Centers Extended warranties are available for purchase at www.progressivedyn.com Member Thank you for selecting Progressive Dynamics as
12-Volt Negative Ground Installation Instructions
12-Volt Negative Ground Installation Instructions For Part Number: 1141, 1164, 1165, 1181 CAUTION!!! Before installing, please read the following important information... 1. The Ignitor is designed for
Installation and Operation Guide for PD4000 Series Power Control Center
Extended warranties are available for purchase at www.progressivedyn.com Installation and Operation Guide for PD4000 Series Power Control Center Member Thank you for selecting Progressive Dynamics as your
Installation Instructions
520 Installation Instructions Thank you very much for purchasing PIAA product. Please read this entire manual before installation and use of this product. For Installers Please give this Installation Manual
AEROMOTIVE Part # 16302 INSTALLATION INSTRUCTIONS
AEROMOTIVE Part # 16302 INSTALLATION INSTRUCTIONS CAUTION: Installation of this product requires detailed knowledge of automotive systems and repair procedures. We recommend that this installation be carried
XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free 1 866 295 6775. www.powerbright.com
WARNING: This Unit employs Components that tend to produce arcs or sparks To prevent fire or explosion, do not install in compartments containing batteries or flammable materials - SHOCK HAZARD. DO NOT
Installation Guide Smart-UPS X External Battery Pack SMX120BP
Installation Guide Smart-UPS X External Battery Pack SMX120BP Inventory Inspect the contents upon receipt. Notify the carrier and dealer if there is damage. Two bezels Tie brackets used to secure multiple
Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1
REMOTE METER TM Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1 1098 Washington Crossing Road Washington Crossing, PA 18977 USA www.morningstarcorp.com
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
PEDAL POWER. User s Manual
PEDAL POWER AC User s Manual Copyright 2005-2008 by Digital Music Corporation. This publication is protected by copyright and all rights are reserved. No part of it may be reproduced or transmitted by
Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger
Digital echo-charge Owner s Manual Xantrex Digital echo-charge Battery Charger Thank you for purchasing a Xantrex Digital echo-charge. Xantrex Technology Inc. takes pride in manufacturing quality products
Single Station Remote Alarm
ADI 5106G Certified ISO 9001:2000 Single Station Remote Alarm 529 5106-01-120 529 5106-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation
INSTALLATION & OPERATION MANUAL LED
INSTALLATION & OPERATION MANUAL LED Duo Beam TM Introduction... 2 Lightbar Unpacking & Pre-Installation... 2 Installation & Mounting... 3 Wiring Instructions... 4 Maintenance... 4 Flash Pattern Selection...
AM/FM Emergency Weather Radio/Light With Hand Crank Back-Up Power
VEC173 ONE YEAR LIMITED WARRANTY PROGRAM This limited warranty program is the only one that applies to this product, and it sets forth all the responsibilities of Vector Manufacturing, regarding this product.
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
User and Installation Guide
Connect the AC adapter with the amplifier BEFORE plugging the AC adapter into an outlet to avoid spark generation! User and Installation Guide BlueFIDELITYTM Bluetooth Audio Amplifier Model 300 Contents
UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS
UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS CONTENTS Parts List... 2 Parts Diagram... 2 Helpful Hints... 3 Installation... 4 Operation and Troubleshooting Guide... 6 Warranty Information... 8 Form #3132,
WWW.CALIFORNIAAIRTOOLS.COM Customer Support 1-866-409-4581
sound proof AIr CoMprEssor CAbInEt owner's MAnuAl spc03 WWW.CALIFORNIAAIRTOOLS.COM Customer Support 1-866-409-4581 TAbLe OF CONTeNTS INTROduCTION IntroductIon 2 Important Safety InStructIonS 5 components
BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.
BC-5000 BATTERY CAPACITY TESTER OPERATIONS MANUAL COFKO LLC. COPYRIGHT 2010 1 UNPACKING As you unpack your new BC-5000 battery capacity tester, inspect the tester for signs of shipping damage. If shipping
Battery Power Inverters
Battery Power Inverters Renogy 500W 1000W 2000W Pure Sine Wave Inverter Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 1 Version 1.1 Important Safety Instructions Please save these instructions.
Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U
Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U SURT192RMXLBP2 SURT192RMXLBP2J English 990-2485B 02/2009 Introduction About this UPS The American Power Conversion (APC ) SURT192RMXLBP2 external
USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2
Remote Faucet Pump System USE &CARE GUIDE See Important Safeguards on page 2 An exclamation point within an equilateral triangle is intended to alert user to the presence of important operating and maintenance
Table of Contents WARNING SYMBOLS AND DEFINITIONS
Table of Contents SAFETY INSTALLATION OPERATION MAINTENANCE Safety... 2 Specifications... 4 Installation... 5 Operation... 8 WARNING SYMBOLS AND DEFINITIONS Maintenance... 9 Parts List and Assembly Diagram...
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8
AGS. Owner's Manual. Xantrex Automatic Generator Start Control System
AGS Owner's Manual Xantrex Automatic Generator Start Control System TABLE OF CONTENTS INTRODUCTION...3 Main Features...3 Safety Summary...3 THINGS YOU SHOULD KNOW...4 THEORY OF OPERATION...5 System...5
Utility Distribution Systems
Utility Distribution Systems 6/2012 A0011037 1 WARRANTY This equipment is warranted to be free from defects in materials and workmanship, under normal use and service, for a period of 12 months from date
Machine Safety Switch: SI-LM40 Series Limit Switch Style
Machine Switch: SI-LM40 Series Limit Switch Style SI-LM40 Series Limit Switch Style with Flexible In-Line Actuator Positive-opening safety contacts (IEC 60947-5-1) (not dependent upon springs) Standard
12-Volt 10-Amp Regulated Power Supply
22-506.fm Page 1 Friday, August 6, 1999 12:55 PM Cat. No. 22-506 OWNER S MANUAL Please read before using this equipment. 12-Volt 10-Amp Regulated Power Supply 22-506.fm Page 2 Friday, August 6, 1999 12:55
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
Keysight N4877A Clock Data Recovery and Demultiplexer 1:2
Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 Getting Started Getting Started with the Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 You only need a few minutes to get started
POWER TO GET THE JOB DONE
52720 1.5 AMP SLOW 12 VOLT BATTERY CHARGER OWNER S MANUAL KEEPS BATTERIES FULLY CHARGED IN STORAGE Automatic over-charging protection Short circuit protection Reverse hook-up protection Overheat protection
Alarm Clock USER GUIDE
Alarm Clock USER GUIDE Jazwares, Inc. 2012 CONTENTS Please read the instructions along with the Alarm Clock carefully before you use it, so that you can operate it conveniently. WELCOME & Warnings Page
Owner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
Smile 11 AS-i Emergency stop with safe AS-i input node
Original instructions Smile 11 AS-i Emergency stop with safe AS-i input node SAFETY AT WORK ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand
OWNER'S MANUAL. Model 20-1050CUL AC Power Inverter/Charger System OM/A96283 REV. A
OWNER'S MANUAL Model 20-1050CUL AC Power Inverter/Charger System OM/A96283 REV. A Table of Contents Section 1 Introduction... 1 Section 2 Installing the 20-1050CUL... 4 Section 3 Installing the IFM1 Interface
Warranty Terms. QLogic-provided cables, optics and other accessories are warranted for ninety (90) days from date of purchase.
Warranty Terms QLogic Corporation ("QLogic") provides the following warranties to the original purchaser of QLogic products from QLogic or, in the case of resale, to the initial end user customer (the
Digital Fingerprint safe
Digital Fingerprint safe Model 96846 Operation Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product
ST Series POWER SUPPLIES USER INSTRUCTIONS
Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional
VLT Series 300 Watt True Sine Wave Inverter
VLT Series 300 Watt True Sine Wave Inverter PURE SINE WAVE INVERTER I ON 0 OFF REMOTE CONTROL AC OUTPUT POWER STATUS Vout Vin Models VLT12-300 VLT24-300 300 Watt VLT Series Inverter - 1 - TABLE OF CONTENTS
Wireless Indoor/ Outdoor Thermometer
Wireless Indoor/ Outdoor Thermometer Owner s Manual Please read before using this equipment. ˆ Contents FCC Information... 3 FCC Declaration of Conformity... 5 Preparation... 5 Installing Batteries...
750 WATT Power Inverter
HSK065_ManualEN_050906.qxd 5/12/06 11:48 AM Page 1 HSK065HD 750 WATT Power Inverter Converts 12V DC Vehicle Power to 115V AC Household Power IF YOU SHOULD EXPERIENCE A PROBLEM WITH YOUR PURCHASE CALL TOLL
DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL
DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL Service Information If service or parts are required, contact the nearest Norcold Service Center. To find an authorized Norcold Service Center
Brushless Motors Instructions
Brushless Motors Instructions Thank you for purchasing the Dynamite Fuze Brushless Motor. Fuze brushless motors are high torque motors designed for direct-drive applications. The 1/18 versions feature
K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)
SureGrip TM 80PK-24 Air Temperature Probe Instruction Sheet XWWarning To avoid electrical shock, do not use this probe when voltages exceeding 24 V ac rms or 60 V dc are present. The probe tip is electronically
i410/i1010 AC/DC Current Clamp
/i1010 AC/DC Current Clamp Instruction Sheet Safety Information XW Read First: Safety Information To ensure safe operation and service of the current clamp, follow these instructions: Read all operating
AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E
AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E SENS part no: 101314 Document revision: F DCN No. 106811 Date 8/3/15 1840 Industrial Circle Longmont, CO 80501 Fax: (303) 678-7504
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
Power Max Level 2 Charging Station en Installation and Operating Instructions This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
Owner s Manual. ULTRA-POWER II ACCU-POWER & ACCU-POWER ONBOARD Solid State Fully Automatic Chargers. Manual Number 1017361. Edition Code 0493B0101A
Owner s Manual ULTRA-POWER II ACCU-POWER & ACCU-POWER ONBOARD Solid State Fully Automatic Chargers Manual Number 1017361 Edition Code 0493B0101A General Information This instruction manual should be read
OWNER S MANUAL. Model AE150/AE300/AE500 1.5AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT
Model AE150/AE300/AE500 MULTI-USE SMART BATTERY CHARGER Certified by Californiia BCS Regulations AE300E AE500E 5AMP MULTI-USE AUTOMOTIVE BATTERY CHARGER 3AMP MULTI-USE SMART BATTERY CHARGER AE500E 5AMP
Installation and Operation Guide PD4600 Series Converter Replacement
Installation and Operation Guide PD4600 Series Converter Replacement Extended warranties are available for purchase at www.progressivedyn.com Member Thank you for selecting Progressive Dynamics as your
APC Step-Down Transformer. User s Manual
APC Step-Down Transformer Models: AP9621, SURT005, SURT006, SUTF3, SYTF2, SYTF2J, SYTF3 and SYTF3J User s Manual English 990-7820D, July 2003 TABLE OF CONTENTS APC Contact Numbers and Support Visit the
DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL 854060
DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL 854060 (FOR DUSTTRAK II AND DRX AEROSOL MONITOR MODELS 8540 AND 8543) OPERATION AND MAINTENANCE MANUAL P/N 6008416, REVISION A MAY 2015 Copyright TSI Incorporated
GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)
FEATURES & APPLICATIONS Inexpensive 2 wire to 3 wire start controller for electric start high speed gas generators. Optimized for use with Outback Invertors. Supports three types of 3 wire generator control
12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
Installation and Operation Guide for PD5100 Automatic Transfer Switch
Installation and Operation Guide for PD5100 Automatic Transfer Switch Member P r o gr e ssive Dynamics, Inc. 507 Industrial Rd Marshall, MI 49068 www.progressivedyn.com 2012 Progressive Dynamics, Inc.
Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps
Model Name Total Output Amps Per Bank Battery System Pro XL Dual Pro XL Pro SE Dual Pro SE Three Bank Pro SE Four Bank Pro SE Pro Charger Dual Pro Charger Three Bank Pro Charger 6 amps 12 amps 10 amps
Universal Vehicle Power Supply 9007AX01. Installation Instructions
Universal Vehicle Power Supply 9007AX01 Installation Instructions Disclaimer Honeywell International Inc. ( HII ) reserves the right to make changes in specifications and other information contained in
OAK WORKBENCH WITH 2 DRAWERS
OAK WORKBENCH WITH 2 DRAWERS Model 93991 ASSEMBLY Instructions Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result in serious injury.
INSTRUCTION MANUAL MODEL PCD-88
INSTRUCTION MANUAL MODEL PCD-88 CLOSED CAPTION DECODER LINK ELECTRONICS, INC. 2137 Rust Avenue Cape Girardeau, Missouri 63703 Phone: 573-334-4433 Fax: 573-334-9255 e-mail: sales @ linkelectronics.com website:
Installation & Operation Manual
GET CONNECTED Installation & Operation Manual DEVICE INTEGRATION AND CHARGING KIT TranzIt USB IS32 Note to Readers, The information contained within the following documentation is subject to change without
user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4
user s manual model #: SPB3200 Charger for Samsung Galaxy S 4 What s Included Unpack the battery case and make sure all accessories are put aside so they will not be lost. hello. USB to Micro USB Cable
Nest Learning Thermostat Installation Guide. Installation step-by-step
Nest Learning Thermostat Installation Guide Installation step-by-step Contents Compatibility. 3 In the box. 4 Before you start. 5 Choose an installation method. 6 Replacing an existing wired thermostat.
Battery Charger. Instruction Manual 309502G
Instruction Manual Battery Charger 309502G EN Part No. 117427, Single Bay Charger, Series B, North America (N.A.) Part No. 120110, Single Bay Charger, Series B, Australia Part No. 117429, Four Bay Charger,
16/32 Channel 1U Rack Mount CCTV Power Supply
16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel
Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P
Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P Distributed in the U.S.A. and Canada by CHENG USA, INC. Sales (574) 294-8997 Warranty Service (877) 294-8997
SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE
SP4LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE INSTALLATION AND OPERATION MANUAL MASS NOTIFICATION SYSTEM Part Number: P84767 Rev. A Copyright 2006 Cooper Wheelock, Inc. All rights reserved.
VK-250 WARRANTY REGISTRATION FORM
VK-250 WARRANTY REGISTRATION FORM Unit Serial Number: Customer Name: Address: Date of Purchase: Purchased From: Dealer Name: Address: IMPORTANT NOTE: In order to receive the full five year product warranty,
LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL 16350 TYPE 12/24EL40-10ET
LESTRONIC DV AUTOMATIC 12 OR 2 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL 16350 TYPE 12/2EL0-10ET PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS For correct operation of the equipment,
SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions
SBC90 Abrasive Blast Cabinet Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. This manual provides important
Unpacking, Installation, and Customization
Unpacking, Installation, and Customization NetShelter WX Enclosure AR100 AR100HD Contents Unpacking... 1 How to Unpack the Enclosure............................... 1 Please Recycle..........................................
How To Use A Cdm250 Digital Multimeter
User Manual CDM250 Digital Multimeter 070-6736-03 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this
Part I - Installation
400 Series Pressure and Differential Pressure Switches Types: H400, H402, H403, H400K, H402K, J400, J402, J403, J400K, J402K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read
Power Lift & Recline Chair
Power Lift & Recline Chair OWNER S MANUAL MAXICOMFORT MODELS The Best Power Lift and Recline Chair Made in the USA 401 Bridge Street Old Forge PA 18518 www.goldentech.com Dear Valued Customer, Thank you
INSTALLATION & OPERATION MANUAL
INSTALLATION & OPERATION MANUAL HB6PAKX & HB6PAKXX HIDE-A-BLAST STANDARD HIDE A BLAST UNIT HB6PAK-PI-X NGPI TWIST LOCK HIDE-A-BLAST LED WARNING LIGHT NGPI TWIST LOCK HIDE A BLAST UNIT IMPORTANT: 6 LED
Owner s Manual 900.4. 4 channel amplifier
Owner s Manual 900.4 4 channel amplifier THANK YOU Limited Warranty: for purchasing RE AUDIO Bluetooth amplifiers BT-900.4. With almost no sacrifice on sound quality, BT-900.4 easily plays the music from
Architect/Contractor Information Package
Architect/Contractor Information Package 3M SelfCheck System C-Series C1 Model 877 This package provides architects and contractors with the information necessary for the successful installation of the
ABR Brake Rectifier Instruction Manual
ABR Brake Rectifier Instruction Manual Part Number: 552074 Copyright 2012 Magnetek 1. Preface and Safety All rights reserved. This notice applies to all copyrighted materials included with this product,
Manual. Solar Fountain Mobile Phone Charger
EN Manual Solar Fountain Mobile Phone Charger Copyrights 2008 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose.
RT-200 HI-TEST ROPE TESTER
RT-200 HI-TEST ROPE TESTER Operating & Instruction Manual HD ELECTRIC COMPANY 1 4 7 5 L A K E S I D E D R I V E W A U K E G A N, I L L I N O I S 6 0 0 8 5 U. S. A. P H O N E 8 4 7. 4 7 3. 4 9 8 0 FA X
OWNERS MANUAL FOR CORDLESS INFLATOR AIR260
OWNERS MANUAL FOR CORDLESS INFLATOR AIR260 POWER SUPPLY OUTLET: AIR OUTPUT: BATTERY: RECHARGING TIME: WEIGHT: DIMENSIONS: FUSE: LIGHT BULB: SPECIFICATIONS DC 12V 15 AMP 180W MAX 260 PSI MAX PRESSURE SEALED
Mounting Details - Footpads & Brackets
Mounting Details - Footpads & Brackets CEMA B Details CEMA C/D Details CEMA E Details " x SLOT " x SLOT Trougher - Belts Trougher - Belts Trougher - Belts " x SLOT " x SLOT / Trougher - Belts Trougher
Anthro Tablet Charging Cabinets
Owner's Manual for Anthro Tablet Charging Cabinets Covers part numbers beginning TAB16 and TAB20. Components at a Glance The open views of the front and side of the cabinet below are for the TAB20 cabinet.
EPM3. Phase Sequence and Motor Rotation Tester. Users Manual
EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR
Remote Alarm Monitoring System
Remote Alarm Monitoring System Operation and Service Manual Model RA1 RA4 A A Version HELMER SCIENTIFIC 14400 Bergen Boulevard Noblesville, IN 46060 USA PH +1.317.773.9073 FAX +1.317.773.9082 USA and Canada
EnduraLAM 150 User Manual
EnduraLAM 150 User Manual SIGNWarehouse, Inc. 2614 Texoma Drive Denison, Texas 75020 800-699-5512 Website: www.signwarehouse.com Email: [email protected] Copyright 2014 SIGNWarehouse, Inc.
Mini-led spotlight with magnetic base
Mini-led spotlight with magnetic base Model 95799 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission
ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL
ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS: INSTALLATION USE & CARE MANUAL IMPORTANT INFORMATION Assembly Instructions 2 Wiring Instructions 2 Outdoor Installation
Owner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
Charge Regulator SCR 12 Marine
Charge Regulator SCR 12 Marine Manual Many thanks for purchasing a superwind product. The SCR 12 Marine is a charge regulator of highest quality and will perfectly and reliably charge your batteries for
Installation and Operating Instructions (for chargers shown below)
Installation and Operating Instructions (for chargers shown below) For additional information please call our Technical Support Group 800.742.2740 PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard,
OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER
OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER P110 Your battery charger has been engineered and manufactured to Ryobi s high standard for dependability, ease of operation, and operator safety. When properly