Light Source User Guide



Similar documents
ORLAND FOLLOW PR-1211

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

19 LED Tube Controller ORDERCODE 41003

DP-DMX20L 4 CHANNEL DMX DIMMER PACK MODE MENU DISPLAY. OUTPUT: 10A/CH, TOTAL 20A Max. DMX CHANNEL RECEIVE TOTAL DMX CHANNEL DIMMER / SWITCH

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

LED Cube Direct Control 30 ORDERCODE 41131

MAINTENANCE & TROUBLESHOOTING

Universal Fibre Optics L E D L I G H T S O U R C E S

ComPar KIT 1 & 2 DMX LED light set

MAINTENANCE & TROUBLESHOOTING

Acrobat. user manual

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

INFRARED QUARTZ WALL HEATER

Portable Air Conditioner

VK-250 WARRANTY REGISTRATION FORM

Bubble King. User Manual

HP UPS R1500 Generation 3

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

TABLE OF CONTENTS. 6. Technical Specifications Page 2 of 20 COLORband PiX User Manual (Rev. 02)

LED BAR 126 / 252 RGB. Owner s Manual LED BAR RGB

TABLE OF CONTENTS. Returns Contact Us... 20

FG MOISTURE MONITOR Installation & Operation Manual

PART 1 PRODUCT (GENERAL)...1.

Operating Instructions Bedienungsanleitung Mode d emploi

LED Par 56 Ultra Bright RGB Black ORDERCODE Polished ORDERCODE 42451

ORDER DIRECTLY TODAY AT: or CALL TOLL FREE Foglio di Istruzioni Owner s manual IMPERIAL. GR 0035 Xenon 4000

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

Moving Head - One Signal Cable - One Omega Clamp One Power Cable - One Safety

LEDPAR64 USER MANUAL

LED Par 56 Short DMX ORDERCODE 42421

Fixture One Power Cord One User Manual One Omega Bracket One DMX Cable - One

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

K E E P E TH T I H S I MA M N A U N A U L A FO F R

Instruction manual for Firstline FCS12000CH

Shogun Blue Laser Head ORDERCODE 30972

3 WATT LED SPOTLIGHT Model No. SLM

PDS-375-TR Touring CB Power/Data Supply Operator s Manual Rev 1.2

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Operating Instructions Air Conditioner

Sunstrip Active DMX ORDERCODE 30710

LED Matrix Blinder 5x5 DMX blinder. user manual

Hegel H1 High End Integrated Amplifier

CB-100 LED Color Beam LED spotlight. user manual

DDP-405 USER'S MANUAL

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

USER MANUAL PLEASE KEEP THIS FOR FUTURE USE

HID H4 BI-XENON FITTING GUIDE. Carefully read the following notes before starting work.

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

6x 54w SuperZoo T5 HIGH FREQUENCY ELECTRONIC CONTROLLER LUMINAIRE

PDS-750-TR Touring Power Supply Operator s Manual

FT-100 Fire Training Fog Machine User Manual English

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

MultiDim MKII V.2 ORDERCODE 50386

user guide Meridian 558 Multi Channel Power Amplifier

Ref. Nr LCP-288 LED COLOR PANEL 288X LED 5MM MANUAL

TABLE OF CONTENTS. Hurricane 1300 User Manual 2 Rev. 4

VX 2400 Dimmer User's Manual

V94 BULK TAPE DEGAUSSER

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Drayton Digistat +2RF/+3RF

Digi-Motor Installation Guide

Snapshot. LEDrain 38 USER MANUAL. Ok on Dimmer. Outdoor OK. Sound Activated. DMX/Master/Slave. 115V/230V Switch. Replaceable Fuse.

INSTALLATION & USER INSTRUCTIONS

NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS

Fading Red Tones on Color LaserJet 2600s

ATS Overhead Table Shelf System INSTRUCTION MANUAL

MCR1900 Media Converter 19-Slot Chassis

Battery Power Inverters

User s Manual Before using the inverter, you need to read and save the safety instructions.

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

Warning! To prevent or reduce the risk of electrical shock or fire, do. Caution! There are no user serviceable parts inside this unit.

The Foundation User Manual LED Battery Slim Par Fixture (RGBA, DMX 7Ch/4CH)

PART 1 PRODUCT (GENERAL)...1.

IT-12M IT-12D Ver_2.0 INTERPRETATION SYSTEM. User s Manual

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

Antenna Splitter ASA 1. Instruction manual

2-SLICE COOL TOUCH TOASTER

Please read and keep these instructions. Run water through your machine before first use

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

16/32 Channel 1U Rack Mount CCTV Power Supply

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Bullet Camera. Installation Guide. Hangzhou Hikvision Digital Technology Co., Ltd.

FLEXIT S4 R S6 R S7 R

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Installation and User Guide

BSE Geluid en Licht Pagina 1 van 5. Description

USER S MANUAL HSC-24A

MBSAW. Meat Cutting Band Saw With Meat Grinder Assembly & Operating Instructions

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Manual for Fire Suppression & Methane Detection System

BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716

HP 22-in-1 Media Card Reader

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

OPL BASIC. Dosing System for Professional Laundry machines. Contents

WB/WBS 3, 4, 5, 7, 8, 11, 14, 30

3000W Power Inverter

Transcription:

Light Source User Guide Compact DMX Light Source Models covered by this manual: UFO 150 CDMXG Glass, DMX - 240V UFO 150 CDMXP Plastic, DMX - 240V Universal Fibre Optics Issue 2 Revised: 23092013 Universal Fibre Optics Home Place Coldstream TD12 4DT United Kingdom Tel: +44 (0)1890 883416 Fax: +44 (0)1890 883062 www.fibreopticlighting.com

INTRODUCTION Thank you for purchasing this UFO Light Source. Please read these instructions fully before connecting your unit to the electrical supply, and keep them for future reference. The UFO Compact DMX are a range of low profile light sources which use 150W metal halide discharge lamps to give much greater brightness than those powered by halogen lamps. These models have a fast re-lamping feature (the lamp is mounted on a pull out hatch at the rear) and are fitted with a DMX controller allowing a range of in-built effects or control via a standalone controller. We do not recommend that the light source be left on for 24 hours a day, 7 days a week as lamp life will be impaired. A switch off of 30mins per day is recommended. IMPORTANT THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED Do not operate without complete lamp enclosure in place or if lens is damaged. KEEP HARNESS IN PLACE WHEN IN OPERATION. CAUTION: Hot surface. Keep away from curtains and other combustible materials. WARNING: RISK OF FIRE/INJURY TO PERSONS. Keep away from combustibles. Unplug to change lamp. Do not touch lamp. WARNING: RISK OF FIRE. Do not place lamp where the overhead surface is closer than 0.2m to the light source. 1 Compact DMX Light Source Range

IMPORTANT SAFETY INFORMATION INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS IMPORTANT SAFETY INSTRUCTIONS Lighted Lamp is HOT: WARNING To reduce the risk of FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS: 1. Unplug and allow to cool before replacing lamp. 2. Lamp gets HOT quickly! Only contact plug when turning on. 3. Do not touch hot lens, guard, or enclosure. 4. Do not remain in light if skin feels warm. 5. Do not look directly at lighted lamp. 6. Keep lamp away from materials that may burn. 7. Use only the correct lamp wattage as detailed on the serial label. Failure to adhere to this will cause damage to the unit. 8. Do not touch the lamp at any time. Use a soft cloth. Oil from skin may damage lamp. 9. Do not operate product with missing or damaged guard, lamp containment barrier, lens or fibre-optic harness. 10. WARNING - Lamp types are matched to the ballast and different wattages/types cannot be used. SAVE THESE INSTRUCTIONS Always disconnect the unit from the power supply before opening or attempting to perform any work on it. UNIT MAY GET HOT - always allow unit to cool down before handling or moving it. Do not touch or attempt to remove the lamp while it is hot. Ensure that the power supply is correct for the unit before powering it up. Always ensure that the unit is properly EARTHED. Do not expose the unit to rain or moisture. Keep away from all combustible materials. Never attempt to tamper with the wiring or other internal components. Keep the unit away from gas, oil and any other flammable or explosive materials. Indoor use only. Universal Fibre Optics 2

LIGHTSOURCE LAYOUT Item Description 1 Fibre port connector 2 Control button 3 Control button 4 Display 5 Microphone 6 Cooling fan grille 7 XLR socket 8 XLR socket 9 Lamp holder 10 Mains input socket & fuse holder and power LED 11 Hole with cover to access fibre optic connector retaining screw 3 Compact DMX Light Source Range

INSTALLATION GUIDE In order for the Compact light source to function safely and efficiently it must be installed according to this user manual. Please read all sections thoroughly before switching on the light source. POWER SUPPLY REQUIREMENTS Before plugging in the unit, please make sure that the supply is correct. Failure to do so could cause the unit to malfunction. The unit requires a 240VAC 50Hz supply and it MUST BE EARTHED. The light source units are provided with a cordset fitted with a standard 3-pin plug. POSITIONING THE UNIT The light source can be mounted horizontally, vertically or upside-down on any flat surface. Keyhole slots are provided on the base of the unit to allow for securing to a surface. The light source is only suitable for use in a dry area. If the unit is being mounted at a higher than the ground level, block access below the work area before installing. Verify that any screws or bolts can safely bear the weight of the light source. Universal Fibre Optics 4

INSTALLATION GUIDE (Continued) Verify that the supporting structure can safely bear the weight of all installed units, cables and any other equipment. The minimum thickness of the mounting surface must be no less than 19mm. For horizontal mounting, it is recommended that the lightsource is secured to a solid surface using 4 x M4 or M5 screws or bolts and the keyhole slots. This is particularly important if the lightsource location is not at ground floor level. To mount the light source vertically, first securely install 4 x M4 or M5 screws or bolts at the required distances so that they will line up with the keyhole slots. The light source can then be mounted onto them and slid into position. The bolts or screws MUST then be fully tightened. To mount the light source under a surface, first securely install 4 x M4 or M5 screws or bolts at the required distances so that they will line up with the keyhole slots. The light source can then be mounted onto them and slid into position. The bolts or screws MUST then be fully tightened. CLEARANCE / VENTILATION It is imperative that a gap of 200mm (8 ) or more is left around the unit. This is to allow air to circulate and prevent overheating. The location must have free ventilation. 5 Compact DMX Light Source Range

INSTALLATION GUIDE (Continued) CONNECTION There are 3 main connections required, the fibre port, the mains power and the DMX connections. Connect and secure the fibre optic connector to the fibre port before connecting the electrical supply. Never run the light source with the fibre connector unplugged. The fibre optic connector is secured into the port by removing the small cover on the top of the light source (see item 11 on page 3), and tightening the retaining screw. The cover should then be replaced. DMX data connections are provided at the rear of the Light Source, connection details as follows Like all data networks the DMX cable should be terminated on the DMX OUT of the last Light Source on the network using a terminator plug OPERATION This light source can be operated in stand alone mode, or can be connected to a compatible DMX controller. In Standalone Mode the Compact DMX can be used as a single independent Light Source or in a Master Slave configuration with several Light Sources connected together using DMX leads. In Master Slave configuration all addresses are set the same and whatever programme is selected on the Master DMX Light Source will also be observed on the Slave Light Sources. In DMX mode the DMX controller can be programmed to control Compact DMX Light Sources either in a block (all same addresses) or independently (all different addresses). Universal Fibre Optics 6

INSTALLATION GUIDE (Continued) OPERATION (Continued) When the DMX Light Source is powered up the unit will RESET during which, the following flashing message will be displayed on the front panel display (Item 4 Page 1): When the Light Source is RESET the following message will be displayed: This indicates the Light Source has been set to address 001 by default. PROGRAMMING At any stage during programming, when changes are made the DMX may go through the RESET phase as described above this is normal. Changing Address To change the address press the 2 buttons to the left of the display (Items 2 & 3 Page 1) simultaneously once the small indicator in the bottom right of the display will go out. Scroll for the required address as follows: Once the selected address is found, there will be a short delay (may RESET) until the small indicator illuminates confirming the address is set. 7 Compact DMX Light Source Range

INSTALLATION GUIDE (Continued) PROGRAMMING (Continued) Colour Wheel Built in Programs To access the built in programmes as described in the User Guide proceed as follows. Press the 2 buttons to the left of the display (Items 2 & 3 Page 1) simultaneously twice and the following message will be displayed: After a short delay (may RESET) the small indicator will flash confirming programme mode P01 is set as shown below. The Light Source will display white light: Scroll through the Built in Programs until the desired programme is reached there will be a short delay (may RESET) until the small indicator flashes confirming the address is set. The set programme will now run. The programme will only run if left in this mode, returning to the Address Mode will stop the program running. To return to Address Mode press the 2 buttons to the left of the display (Items 2 & 3 Page 1) simultaneously three times. Note 1: There is an Auxiliary mode which may be displayed as shown below. This is not used. If in this mode press the 2 buttons simultaneously twice to return to Address mode: Note 2: In Master/Slave and Remote DMX controller operation the small indicator flashes to indicate DMX data transmission Universal Fibre Optics 8

BUILT IN PROGRAMS Program number P01 P02 P03 P04 P05 P06 P07 P08 P09 P10 P11 P12 P13 P14 P15 P16 P17 P18 P19 P20 P21 P22 Function White Yellow Green Orange Magenta Blue Cyan Jade W,Y,G,O,M,B,C,J - flash change 2 seconds W,Y,G,O,M,B,C,J - flash change 5 seconds W,Y,G,O,M,B,C,J - flash change 10 seconds W,Y,G,O,M,B,C,J - flash change 30 seconds W,Y,G,O,M,B,C,J - flash change 60 seconds W,Y,G,O,M,B,C,J - flash change 2 seconds W,Y,G,O,M,B,C,J - flash change 5 seconds W,Y,G,O,M,B,C,J - flash change 10 seconds W,Y,G,O,M,B,C,J - flash change 30 seconds W,Y,G,O,M,B,C,J - flash change 60 seconds W,Y,G- flash change 2 seconds W,Y,G- flash change 5 seconds W,Y,G- flash change 10 seconds W,Y,G- flash change 30 seconds 9 Compact DMX Light Source Range

BUILT IN PROGRAMS Program number P23 P24 P25 P26 P27 P28 P29 P30 P31 P32 P33 P34 P35 P36 P37 P38 P39 P40 PS1 PS2 PS3 PS4 Function W,Y,G- flash change 60 seconds W,Y,G,O - flash change 2 seconds W,Y,G,O - flash change 5 seconds W,Y,G,O - flash change 10 seconds W,Y,G,O - flash change 30 seconds W,Y,G,O - flash change 60 seconds 8 colours slow change (0.2 RPM) 8 colours slow change (0.5 RPM) 8 colours slow change (1.0 RPM) 8 colours slow change (2.0 RPM) 8 colours slow change (3.0 RPM) 8 colours slow change (5.0 RPM) 8 colours slow change (8.0 RPM) 8 colours slow change (12.0 RPM) 8 colours chasing slow change (1.0 RPM) 8 colours chasing slow change (2.0 RPM) 8 colours chasing slow change (3.0 RPM) 8 colours chasing slow change (5.0 RPM) W,Y,G,O,M,B,C,J - audio control W,Y,G,O,M,B,C,J - audio control W,Y,G- audio control W,Y,G,O - audio control Universal Fibre Optics 10

DMX ADDRESSES Channel No. Function Address Value Effect (Colourwheel versions) Effect (Dimmer wheel versions) 01 Snap to colour 0-15 Clear (white) Dim level 1 01 Snap to colour 16-31 Colour 1 (yellow) Dim level 2 01 Snap to colour 32-47 Colour 2 (green) Dim level 3 01 Snap to colour 48-63 Colour 3 (orange) Dim level 4 01 Snap to colour 64-79 Colour 4 (magenta) Dim level 5 01 Snap to colour 80-95 Colour 5 (blue) Dim level 6 01 Snap to colour 96-111 Colour 6 (cyan) Dim level 7 01 Snap to colour 112-127 Colour 7 (jade) Dim level 8 01 9 colour sequence 5 seconds 01 9 colour sequence 7 seconds 01 9 colour sequence 12 seconds 01 9 colour sequence 15 seconds 01 9 colour sequence 20 seconds 01 9 colour sequence 60 seconds 128-143 C,Y,G,O,M,B,C,J 5 seconds 144-159 C,Y,G,O,M,B,C,J 7 seconds 160-175 C,Y,G,O,M,B,C,J 12 seconds 176-191 C,Y,G,O,M,B,C,J 15 seconds 192-207 C,Y,G,O,M,B,C,J 20 seconds 208-223 C,Y,G,O,M,B,C,J 60 seconds N/A N/A N/A N/A N/A N/A 11 Compact DMX Light Source Range

MAINTENANCE LAMP REPLACEMENT - Recommend Lamp change every 12 months for Metal Halide Lamps should not be run to the end of their life. 1) Unplug unit from electrical supply and allow to cool. 2) On the rear of the unit, unscrew the two knurled securing nuts (A) which hold the lamp holder in position. 3) Use the handle (B) to withdraw the lamp holder(c) from the light source. 4) Unplug the old lamp from its ceramic holder. 5) Plug the new lamp into the holder, making sure that you use a bulb of the same specification as to that which was removed. Also make sure not to touch the glass part of the lamp. 6) Slide the lamp holder plate back into position and tighten the two retaining nuts. FUSE REPLACEMENT 1) Unplug unit from electrical supply and allow to cool. 2) The fuse is located in a drawer under the mains input connector. There is also a spare fuse located in this drawer 3) Open the fuse drawer. 4) Withdraw fuse from its holder 5) Replace with identically specified fuse - see specification table in this manual. 6) Close the fuse drawer and power up the light source. Universal Fibre Optics 12

MAINTENANCE (Continued) CLEANING THE UNIT Disconnect unit from power supply and allow to cool before attempting any cleaning of the unit. A visual check of the unit should be completed every 12 months. However cleaning should take place as and when required. The body of the unit can be cleaned with a soft, damp cloth - do not use any abrasives on the unit. The fans and vents should be kept clear by periodically blowing them out with compressed air. Glass filter to be cleaned with soap and water then dried. Please note that a record of all maintenance MUST be kept in the table below, indicating what maintenance was undertaken and when. This must be DATED for warranty purposes. Date Maintenance Undertaken 13 Compact DMX Light Source Range

TROUBLESHOOTING Problem Probable cause(s) Remedy Main fuse blown Check and replace fuse. Unit is completely dead - Lamp and LED power indicator are not illuminated No power to unit Check that power is switched on and power supply is plugged in. LED power indicator & fan are on, but no light is output Lamp blown Thermal switch activated Lamp wires are not connected Replace lamp Allow unit to cool for 5 to 10 minutes and investigate reason for overheating Check plug connection - ensure lamp is properly seated in its holder and the pins are fully mated Lamp needs replacing Replace lamp Unit needs cleaning Clean glass lens Poor light output Lamp going on & off randomly Incorrect power supply Fibre port connector not plugged in correctly Unit is overheating Ensure power supply is 240VAC 50Hz Ensure fibre port connector is plugged in correctly, and that the screw is tightened up properly Allow unit to cool for 5 to 10 minutes and investigate reason for overheating Please complete troubleshooting procedures before returning unit to us for further investigation. Universal Fibre Optics 14

TECHNICAL SPECIFICATIONS Description Port connector size Fibre type Supply voltage Lamp power Input power Start up current Running current Min. ambient temp. 150W DMX 30mm diameter Glass / polymer 240VAC 50Hz 150W 180VA @ 240VAC 0.3A @ 240VAC 0.75A @240VAC -20 C Max. ambient temp. 40 C Thermal protection Ballast type Fan tye (polymer fibre) Fan type (glass fibre) Power cord Main fuse Lamp type Thermal switch Electronic Papst 8550N Papst 8880N IEC mains cable 4 Amp Metal halide Lamp model Philips CDM-SA/T or CDM *Lamp life c. 9000h (SA/T) c. 12000h (CDM) Lamp colour temp. 4200K (SA/T) 3000K (CDM) Lamp CRI 95 (SA/T) 88 (CDM) Control options DMX, standalone, master/slave DMX channels 1 Protocol DMX 512 Colour wheel 7 colours plus white Standard colours Green, blue, yellow, magenta, jade, cyan, orange Acoustic rating (polymer fibre) 38.0dB(A) Acoustic rating (glass fibre) 23.0dB(A) Operating environment Indoor / dry Protection rating IP20 Material Sheet steel Colour Black Size 298x232x144 mm Weight 4.4kg * lamp life as stated by manufacturer in optimum conditions 15 Compact DMX Light Source Range

NOTES Universal Fibre Optics 16

NOTES 17 Compact DMX Light Source Range

NOTES Universal Fibre Optics 18

Universal Fibre Optics Home Place Coldstream TD12 4DT United Kingdom Tel: +44 (0)1890 883416 Fax: +44 (0)1890 883062 www.fibreopticlighting.com