1 2006 International Building Code, International Code Council, Country Club Hills, IL, p. 23



Similar documents
Chapter 3: Use and Occupancy Classification

SECTION 903 AUTOMATIC SPRINKLER SYSTEMS

Code Requirements for Existing Buildings

Errata has been identified as follows:

M E M O R A N D U M. To: Partnership for Safer Buildings Date: 21 March 2003

CITY OF CHICAGO DEPARTMENT OF BUILDINGS RULES AND REGULATIONS for CERTIFICATES OF OCCUPANCY

City of Riverside Building & Safety Division Phone: (951)

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT

PROJECT SUMMARY. Scope of work details: (If phased construction, please see plan submittal guidelines.)

2006 IBC BUILDING CODE CHECKLIST FOR COMMERCIAL PROJECTS

Executive Summary Inclusion of Current Firewall Requirements in NBCC

contents 1. Introduction 7. Types of Construction IBC - Chapter 6 NFPA Section Analysis & Recommendations

NC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02

REGULATIONS for INSTALLATION, MAINTENANCE, and TESTING APPLICATION PACKET

Indiana Building Rehabilitation Standard

2012 Michigan Rehabilitation Code for Existing Buildings ISBN:


GENERAL BUILDING HEIGHTS AND AREAS; SEPARATION OF OCCUPANCIES

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

The New Life Safety Chapter What It Applies to and How Organizations Can Comply with It

2012 IBC & 2012 NFPA 101 Significant Means of Egress Changes. Questions Design Occupant Load Means of Egress Capacity Determination

Massachusetts State Building Code 8 th Edition

Certification: Building Plans Examiner. Exam ID: B3

The Accord on Fire and Building Safety in Bangladesh Building Standard

SWAN POINT YACHT & COUNTRY CLUB

NFPA FAQs. 3. Can plastic pipe be used on a sprinkler system complying with NFPA 13?

Understanding the Life Safety Code

Comparison of the Structural Provisions in the International Existing Building Code 2012 versus the Rhode Island State Rehabilitation Code

New York City Department of Buildings

Type IIB, Type IIIB (Unprotected Construction) Story Comparison (w/ NFPA 13 Sprinklers)

COMMON FOR ARCHITECTS AND ENGINEERS Excerpts from HB 2284, 82 nd R

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES (Adopted by the State of Oregon)

Fire Alarm Systems Requirements by Occupancy Type

The 60 minute Fire Rated Application Explained

New York City Department of Buildings

2012 Changes of the International Building Code Compared to the National Fire Protection Association- 101

UL Fire Door Inspection Service. UL Fire Alarm Certification Program. A valuable but misunderstood resource for jurisdictions

FIRE LOSS STATISTICAL CONSIDERATIONS IN RELATING FAILURE AND BUILDING DAMAGE TO THE BUILDING CODE OBJECTIVES

Fire-Retardant-Treated (FRT) Plywood

Healthcare Engineering. Code Summary Report

How To Calculate Fixture Counts For A Building

Classroom Door Security & Locking Hardware

Inspection, Testing and Maintenance

It is also an integral component of the Municipal Fire Protection Information Survey (MFPISS).

Fire-Rated Glass and Glazing START

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

Solar America Board for Codes and Standards

February 2011 Meeting. Friday, 02/18/2011. Jefferson County Fairgrounds Exhibit Hall West 6 th Avenue Golden, CO 80401

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

Building Code Clarifications - 7. Fire Resistance

Design Development Quality Management Phase Checklist Project Phase Checklist Series

Building Permit, Fire Inspection and Operating Permit Fee Schedule

CHILD CARE CENTER INFORMATION SHEET

Florida Advanced Building Code Course# FLBC11

Dollars & Sense of Compliance!

Commercial Fee estimate The Building department will provide the actual fees at the time the permit is issued.

CHAPTER 29 PLUMBING SYSTEMS. [P] TABLE MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES a (See Sections and ) 1 per 40 for the

ADA Design Guide Washrooms & Showers

SCHEDULE A BY-LAW B-6 CLASSES OF PERMITS AND FEES

SECTION THREE CONSTRUCTION CODES

Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces

Health Chapter ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE

* Any required illumination shall be arranged so that the failure of any single lighting unit shall not leave any area in darkness.

2. Farm buildings located outside the building rules jurisdiction of any municipality.

Residential Plan Review Emergency Vehicle Access and Water Supply Permit Information Packet

Single Family Residential Building Permit Questions & Answers

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

FIRE PROTECTION IN THE 2008 NEW YORK CITY BUILDING CODE

Glass and Building Regulations Impact Safety

DEPARTMENT OF BUILDINGS

APPLICATION FOR NEW CONSTRUCTION

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Requirements for Hydrogen Storage and Use

County of San Diego, Planning & Development Services SECOND DWELLING UNIT

GENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA)

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

CITIZENS TELEPHONE COOPERATIVE SECTION 301

CHAPTER 9 FIRE PROTECTION SYSTEMS

Fire Barriers & Fire Stopping

780 CMR: MASSACHUSETTS AMENDMENTS TO THE INTERNATIONAL EXISTING BUILDING CODE 2009

A history of shaping the

Fire Alarm Submittal Requirements and Acceptance Testing

THE CORPORATION OF THE TOWNSHIP OF SEVERN BY-LAW NO

Schedule B to By-law

BUILDERS RISK APPLICATION

Pyroguard Wired Glass

NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINEERING TECHNOLOGIES. Level III Content Outline

Guide for Opening Child Care and Day Care Facilities

INFORMED MECHANICAL DESIGN THROUGH TESTED AIR LEAKAGE RATES. Jeff Speert, AIA MAIBC LEED AP

In accordance with NFPA 30, these containers are not to store Class I flammable liquids.

CHAPTER 6 CONSTRUCTION TYPES

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

RESIDENTIAL SPRINKLER INSTALLATION GUIDE

ATTACHMENT A SUMMARY OF THE NFIP PROGRAM CHANGES EFFECTIVE APRIL 1, 2016

Title: FIXED ASSET ACCOUNTING Code: B0108

Section 6. Off-street Bicycle Space Regulations

Transcription:

APPLYING MIXED USE, ACCESSORY USE AND INCIDENTAL PROVIONS OF THE 2006 INTERNAITONAL BUILDING CODE By: Carroll Lee Pruitt, FAIA, NCARB, ICC William Rakatansky, AIA, CSI, LEED AP Just when you thought that you had the provisions of mixed use and occupancy down pat, the requirements have completely changed in the 2006 edition of the International Building Code (IBC). While this happens to be the case in the 2006 IBC, many of the requirements have simply been relocated from Chapter 3 to Chapter 5 of the code. One significant change is Table 508.3.3, Required Separation of Occupancies (Hours), which is former Table 302.3.2 in the 2000 & 2003 editions of the code. If one compares the Tables, the 2006 Table is significantly different than the previous editions. This table will be discussed further in the paper. Another significant difference applies to Accessory Occupancies. Occupancy classifications are covered in Chapter 3, Use and Occupancy Classification. Chapter 3 is a scoping chapter. It provides the basis for determining the character of use of a building and thus it s appropriate occupancy classification. In some cases, a building may be of multiple occupancies depending on the use of the building. Section 302.1 requires such building or portion thereof to comply with all of the applicable requirements for the different uses or occupancy. The occupancy classifications in the 2006 IBC are as follows: 1. Assembly (see Section 303): Groups A-1, A-2, A-3, A-4 and A-5 2. Business (see Section 304): Group B 3. Educational (see Section 305): Group E 4. Factory and Industrial (see Section 306): Groups F-1 and F-2 5. High Hazard (see Section 307): Groups H-1, H-2, H-3, H-4 and H-5 6. Institutional (see Section 308): Groups I-1, I-2, I-3 and I-4 7. Mercantile (see Section 309): Group M 8. Residential (see Section 310): Groups R-1, R-2, R-3 and R-4 9. Storage (see Section 311): Groups S-1 and S-2 10. Utility and Miscellaneous (see Section 312): Group U 1 Mixed use and occupancy covers a variety of options open to the designer in these buildings. It is important to understand that Section 508 deals not only with mixed use and occupancy, but also Incidental Uses and Accessory Uses. The requirements for Incidental Uses and Accessory Uses are applicable to single use occupancy buildings as well. Incidental or Accessory Uses must comply with their applicable provisions; otherwise the building must be classified as a mixed use or occupancy building. Mixed use classification applies to a building or portion thereof that is generally of a particular occupancy category such as Group A, but contains various sub-categories of the group such as Group A-1 and A-3. Mixed occupancy classification applies to 1 2006 International Building Code, International Code Council, Country Club Hills, IL, p. 23

buildings or portions of buildings that contain different occupancy classifications such as Group B and Group S-2. INCIDENTAL USES: Incidental uses, as the name implies, are incidental to the main use of the building. They contain hazards that are found in most buildings but do not contribute significantly to the overall fire hazard of the building. A list of incidental uses and their required separation/protection is found in Table 508.2, Incidental Use Areas. These uses must be either separated and/or protected in accordance with the Table. Separation requirements could be 1- or 2-hour and/or protected by an approved automatic fire-extinguishing system. Construction separation requirements are outlined in Section 508.2.2.1. When fire-extinguishing protection is required or permitted, the system is required only in the Incidental Use area unless the entire building is required to be protected with such a system by other provisions of the code. MIXED OCCUPANCIES: Section 508.3 applies to mixed occupancies and or mixed uses. It should be noted that Section titles do not necessarily determine the scoping of the code requirements of the section. Thus, Section 508.3 applies to both mixed uses and mixed occupancies. Section 508.3 Mixed Occupancies contains provisions for accessory occupancies, nonseparated occupancies and separated occupancies.

ACCESSORY OCCUPANCIES: Section 508.3.1 defines Accessory occupancies as those that are ancillary and accessory to the main occupancy of the building or portion thereof. The area of accessory occupancies is limited to 10% of the area of the story in which they are located and are not permitted to exceed the base occupancy tabular area in Table 503. Accessory uses are not allowed to utilize area, height or story increases. There are three exceptions to the accessory occupancy requirements. Except for Group H-2, H-3, H-4 or H-5 occupancies, no separation is required for accessory uses. The allowable area, height and number of stories are based on the primary occupancy. Accessory Occupancies are classified the same as the main use/occupancy. The more restrictive applicable provisions of Section 409 and Chapter 9 apply to the entire building similar to the requirements for nonseparated occupancies. In the graphic below, the Group B might be considered to be an Accessory occupancy. Group S-2 Group B NONSEPARATED OCCUPANCIES: All occupancies except Group H occupancies are permitted to be in nonseparated occupancy buildings. Nonseparated occupancies are literally those in which there is no fire barrier between the various occupancies. As a side note, Group H-1 are always required to be in single occupancy buildings and in some cases, Group H-2 and H-3 occupancies must also be in separate buildings. When using the nonseparated occupancy provisions, the more restrictive occupancy based on the provisions of Table 503 controls including height, number of stories and area. Additionally, the more restrictive provisions of Section 403 and Chapter 9 apply to the entire building. In applying the fire area provisions of Chapter 9, the area of all nonseparated occupancies is used to determine fire sprinkler requirements. The individual occupancies must also comply with any specific occupancy requirements related to their use.

SEPARATED OCCUPANCIES: In contrast to nonseparated occupancies, separated occupancies are those that are provided with the appropriate fire barrier in accordance with Table 508.3.3. Each separate occupancy is classified in accordance to its particular use and each fire area must comply with the code based on each portion of the building. When using the separated occupancy provisions, each occupancy must be separated with fire barriers or horizontal assemblies in accordance with Table 508.3.3.

Don t be confused by Table 508.3.3. Even though certain occupancies are grouped together and do not require separation from one another, they must still be considered separated occupancies unless the building will comply with the nonseparated occupancy building provisions. In the case of separated occupancies the allowable area within each story must be such that the sum of the ratios of the actual floor area of each occupancy divided by the allowable area of each occupancy must be less than or equal to one. The ratio of one is equivalent to 100% of the area that a building is permitted. Group B Group S-2 Group A-3 Actual Group B Actual Group S-2 Actual Group A-3 + + 1 Allowable Group B Allowable Group S-2 Allowable Group A-3 In multiple story buildings, this ratio per floor must be combined with Section 506.4. In a single occupancy building the area of a two story buildings is permitted to be twice the area of a single story building or 200% (x2) of the calculated area, provided the area does not exceed the maximum allowable area per story (100% or x1). Three or more story single occupancy buildings are permitted to be three times the area of a single story

building or 300% (x3) of the calculated area provided the area does not exceed the maximum allowable area per story (100% or x 1). Thus in separated mixed occupancy buildings the ratio per floor may not exceed 1 on any story, but the total of the stories may not exceed 2 (200% or x2) in two story buildings or 3 (300% or x3) in three or more story buildings. See the example below..25.5.25 1.75.25 1.5.5 1.75.25 1 1 1.25.75 1.25.25.33.34.33 1.50.25.75.25.75 1 2 3 3 There are different options to allow a separated mixed occupancy building to comply as follows: 1: Modify the configuration of the different occupancies, or 2. Increase the construction type, or 3. Provide a fire sprinkler system for the building, or 4. Provide a Fire Wall to reduce the Building s total area into multiple buildings. In the example above, a given occupancy may not be in a story higher than that permitted by Table 508.3.3. including permitted increases based on a fire sprinkler system. Following the illustrations in this article should make it easier to correctly apply the complex occupancy provisions when determining type of construction and allowable area.