Description ELGO PNO 1 SSI/ Profibus - Converter



Similar documents
Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Modular I/O System Analog and Digital Interface Modules

Multi-Protocol decoder with Load regulation

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

RS - SPM. Serial parallel translator module

Model 201 Wiegand Touchpad Reader Installation Guide

Duct Humidity Transmitter

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

Series 7500 Torque Sensor

GV- RK1352 Card Reader

TECHNICAL DATASHEET Incremental Encoder RI 80-E

Original instructions Tina 3A/Aps Adaptor unit

Addendum to the Operating Instructions

PROXIMITY CARD READERS C-10, C-20, C60, C70

+ Incremental interface

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Advantium 2 Plus Alarm

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

Temp. & humidity Transmitter Instructions

Electro-pneumatic control valves

Magnetic Length Measuring System

Description. Dimensions. Features. precision works better

GAE953 Electrical Alarm Unit 19" with Indicator

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

6 mm (Synchronus flange) 10 mm (Clamp flange) 10 / 12 mm (Plug shaft) axial 40 N, radial 60 N (10, 12 mm Shaft) Operating speed min -1

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Series 6000 Torque measured metal bellow coupling

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

Digital Keypad Use s Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Tina 2A/B Adaptor unit

Absolute Rotary Encoder E6CP

Cable Plug acc. to DIN EN , Form A

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

ABSOLUTE ROTARY ENCODER ETHERNET/IP

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

2. Remove rear cover of head lamp if bulbs are covered/sealed within the housings, and remove halogen bulb carefully.

Inductive sensor NI10-M18-Y1X-H1141

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

Hardware Manual CAN-IB130/PCIe CAN-IB230/PCIe PCIe/104 CAN Interface

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

HIPERDRIVE HRA71 and HIPER- DRIVE -HUB: Integrated positioning system with absolute distance measurement for format adjustment

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

IMR 6000/10../20../30

ABB Drives. User s Manual HTL Encoder Interface FEN-31

WEB log. Device connection plans

Multifunction devices

Technical definitions of A to Z

Liquid Level Limit Switch liquiphant T FTL 20

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

Reaction Torque Sensor

NC-12 Modbus Application

KNX R. Rain Sensor. Installation and Adjustment

MILE Encoder for EC 90 flat

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Proximity Switches RS (Reed Switch)

Digital input modules

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual

TX OPEN RS232/485 module

Proportional pressure regulators VPPE

L5354 ControlNet Communications Interface

WEB log. Device connection plans

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

PCS0100en Persy Control Services B.V. Netherlands

Smart Sensing Solutions Since 1954

USER MANUAL V5.0 ST100

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Installation Instructions. Thermo Call TC3

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

3x cinch/s-video socket Order no.: xx. USB/3.5 mm audio socket Order no.: xx. VGA socket Order no.: xx

PD 100A. Printing data system

IRT Eurocard. Type DAX Audio Extractor for 270 Mb/s SDI

AR-721U/721K/661U User s Guide

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0

Operation Manual. Plasma torch height controller. Model: Compact THC Controller 150

DeviceNet Bus Software Help for Programming an Allen Bradley Control System

CQM1-SF200/CS1W-SF200

Vibration Monitoring System Adash 3600

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Combi switchbox with integrated 3/2 way pilot valve

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

HERZ-Thermal Actuators

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

MANUAL PC1000R

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Barcode Reader Series BCL 31, BCL 32, BCL 34

Transcription:

Description ELGO PNO 1 SSI/ Profibus - Converter GSD- file is provided on cd-rom or disk also for not ELGO products applicable Profibus - interface after IEC61158/IEC61784 SSI interface 24Bit binär codiert + 1PFB supply voltage +19 to +27 VDC simple assembly intensitive to contamination PNO 1 Profibus-Converter-E_41-06

1. GENERAL 3 2. SECURITY 3 2.1 screening measures 3 3. ASSEMBLY OF THE CONVERTER 4 4. OPERATING PARAMENTER 4 4.1 Attitudes 5 5. EXTERNAL DIMENSIONS 6 6. INTERFACES AND MINUTES 7 6.1 SSI - interface 7 6.2 Profi-Bus interface 8 7. TECHNICAL DATA 9 8. MODEL CODE 9 9. ACCESSORIES 10 10. NON- LIABILITY/WARRANTY 11 page 2 of 11

1. General The ELGO Profibus converter has on the one hand professional bus- interface, on the other hand over 24 bits, standardized after IEC61158/IEC61784, binary coded SSI- interface with power failure bit (PFB). The converter can be thuse everywhere used, where equipment with SSI interface is to be attached to a professional bus. Der ELGO Profibus Converter bietet entscheidende Vorteile: even for older ELGO of devices with SSI - interface applicable is not suitable also for ELGO of products simple/problem-free conversion of SSI on professional bus up to 1200m conduit length transmission rate up to 12MBaud insensitive to dirt (IP50 standard) simple assembly owing to assembly slots 2. Security Note: Before first start-up this installation manual is to be read carefully and the installation hints is absolutely to be obeyed. The converter serves excluding the data conversion of SSI on professional bus. The vehicle identification plate serves for the exact identification of the converter. It is on the converter. There is about the exact type designation, the delivery date and the manufacturing number. With contacts with the company ELGO Electric GmbH is to be always used these data. Note! The company ELGO Electric GmbH is not responsible for possible machine and/or personal injuries, which can result from incorrect material at the converter and follow-up electronics. The machine manufacturer is obligated to seize and accomplish suitable safety-relevant measures. 2.1 screening measures The screen of the signal output cable should be attached only on one side to the following electronics and connected central with protective ground. The signal output cable is to be laid in principle separately from load current lines to and a safety margin from at least 0.5 m to inductive and capacitive interference sources such as contactor, relay, engines, switch power packs, clocked automatic controllers etc. is to be kept. If disturbances should arise despite adherence to all points described above, must be proceeded as follows: attach from RC elements over contactor coils of AC contactors (e.g. 0.1 µf/100 W) attach from flywheeling diodes over DC inductances. attach from RC elements over the individual engine phases and over the exhaust brake (in the terminal box of the engine). protective ground and reference potential do not connect! page 3 of 11

connect a system filter at the external power pack 3. Assembly of the converter The integrated assembly slots at the converter housing make a very simple and self-describing assembly possible from 3 sides. Here arbitrary M6 hexagonal screws can (according to DIN 933) or M6 square nuts (according to DIN 562) to be pushed in, around the system on to fasten the desired place. When a assembling at the top side. It is to be noted that the address attitude and the LED remain accessible. Top side 4. Operating paramenter At the housings top side a green LED (bus run) and a red LED (bus Fail) are attached for the announcement of the operating condition. To the address are attached likewise above two turning coding-switches adjust beside the LED's. Green LED (Bus Run) on = ready for use off = no supply voltage flashes cyclically = Slave does not have a cyclic data exchange with PROFIBUS- DP- MASTER flashes irregularly = approach: missing or incorrect configuration running time: Host-Watchdog-time-error Red LED (Bus Fail) on off flashing = not remediable converter - disturbance = no error/ bus in the cycle = Converter addressed by the master not page 4 of 11

MSD LSD LED RUN (green) ERROR (red) Address attitude: The address attitude is made with the 2 coding switches at the top side of housing. The decade with high order with the coding switch MSD and the low order decade with the coding switch LSD. 4.1 Attitudes Over a GSD file the following parameters are adjustable. (GSD file is provided on disk) Monoflop with 20... 255 µs [ 200 ] number of clocks of SSI 18... 32 [ 24 ] scaling SSI/x 1... 255 [ 1 ] Offset -1073741823... 1073741824 [ 0 ] [ default value ] page 5 of 11

5. External dimensions Plan view 156,00 126,50 48,50 30,00 16,50 13,00 40,00 41,50 27,50 13,50 8,50 40,00 37,00 27,00 10,00 5,00 Ø16,00 Ø16,00 Ø12,00 7,00 55,00 17,50 11,00 3 mm 9 mm drillings Front view Side od the connector 3,00 12,00 17,00 32,50 22,00 55,00 page 6 of 11

6. Interfaces and minutes 6.1 SSI - interface Operational principle: If the clock is interrupted not for the time Tm-T/2 (expenditure of further 25 periods), clocks the shift register again the same data value out (power have error recognition in the evaluation). Some giver failure bit (PFB). Note: With the professional bus - converter should always be the PFB "LOW"! Data minutes: Selections of the data (2 times with 25 clocks) not inverted SSI - By means of at the top side of housing, under a protective plastic film, turning codingswitch present, the data format of the SSI interface between binary and Gray code can be switched. Connection allocations: position code 0 binary 1 Gray Round plug SSI plug (standard) Pin function 1 0 V / GND 2 + 24 VDC 3 Data - 4 Data + 5 Clock - 6 Clock + 7 & 8 N.C. 1 8 6 7 4 2 SSI plug 5 3 page 7 of 11

6.2 Profi-Bus interface The converter is according to standard equipped with a professional bus interface after IEC61158/IEC61784. The following parameters are given: Transmission: RS485 two-wire line conduit length: 1200m with 9,6kBaud 200m with 1,5Mbaud 100m with 12Mbaud Baud rate: 9,6kBaud to 12Mbaud (automatic recognition) clock rate max. 250kHz participant: max. 32 per segment (by Repeater on 126 expandable) mono and multi-masters of systems possible Connection allocations: Profibus IN (Flanged plug M12) Pin Function 1 N.C. 2 Data A 3 N.C. 4 Data B 5 shield Profibus OUT (Flanged box M12) Pin Function 1 N.C. 2 Data A 3 N.C. 4 Data B 5 shield Supply voltage (Flanged Plug M8) Pin color Function 1 brown +19 bis 27 VDC 2 white N.C. 3 blue 0V / GND 4 black N.C. Profibus OUT Profibus IN Supply voltage page 8 of 11

7. Technical data measuring system operating voltage 19... 27 VDC power input max. 0,2 A signal level in accordance with interface specification work temperature 0... + 60 C operating temperature - 20... + 70 C storage temperature - 40... + 85 C air humidity not condensing, max. 80 % operating hight max. 2000 m about N.N. savity class system IP 50: standard version IP 67: option V housing Aluminium (Al/Mg/Si 0,5) dimensions See dimensional drawing conduit lenghts Dependent on bit rate 8. Model code PNO1-000 - XX - X type SSI Profibus Converter SN number special unit number address Work pre-setting of the address option V = poured (IP 67) order example: 1 SSI- professional bus converter after ELGO standard preset address 6Ah, housing poured PNO1-000 - 6A - V page 9 of 11

9. Accessories Connection cable with M8 clutch, 4polig 5m lenght Art. Nr. 503000052 Profibus signal line with M12 plug, 5polig, b- coded (manufactures on one side) 5m lenght Art. Nr. 503000050 with M12 clutch, 5polig, b- coded (manufactures on one side) 5m lenght Art. Nr. 503000051 with M12 plug/ clutch (double sided convected) 5m lenght Art. Nr. 503000054 Profibus terminal resistance with M12 4polig, b- coded Art. Nr. 503000053 page 10 of 11

10. Non- liability/warranty We examined contents of this operating instructions carefully, after best knowledge and certain for agreement with the described hard and software. Nevertheless cannot be excluded errors, mistakes or deviations, so that we do not take over guarantee for the complete agreement. Necessary corrections are contained in the following editions. For suggestions and improvement suggestions we are at any time extremely grateful. Reproduction, duplication and translation, also in part, are permitted only by written permission of the company ELGO Electric GmbH. The company ELGO Electric GmbH is constantly endeavors their products to improve, therefore it reserves itself the right to technical changes without any announcement. For possible errors or mistakes ELGO Electric does not take over adhesion. The guarantee period amounts to 1 calendar year starting from delivery date and extends to the supplied equipment with all parts. They will in form carried out that defects at device/construction units, which developed as can be prove despite appropiate treatment and attention of the operating instructions, due to productions and/or material defects are free of charge exchanged or repaired after our choice. As can be prove not damage due to inappropriate treatment, caused by ELGO Electric GmbH, e.g. creation wrong tension, penetration of liquids in the equipment inside, impact, scratch of the equipment front, chemical influences etc. are from any guaranteeing excluded! Subject to change ELGO Electric GmbH 2006 page 11 of 11