MAGNETOSTICTIVE TRANSDUCER



Similar documents
LVDT. Inductive Position Transducer. SM Series. Key-Features:

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

- 1 - Eddy Current. Eddy current distance and displacement transducer

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Conductive Level Switch FK 2 Technical Data:

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

D. PARAMETER SPECIFICATION Measured Variable: Displacement

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Givare NC-SRS 280 och 880

Inductive sensor NI10-M18-Y1X-H1141

How To Power A Schen

ABSOLUTE ROTARY ENCODER ETHERNET/IP

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Electronic Pressure Switch EDS 300

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Pressure transmitter For general industrial applications Model A-10

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Magnetic Proximity Switches Series CST - CSV and CSH

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

Magnetic proximity switches

maxon sensor maxon sensor

Absolute Rotary Encoder E6CP

TECHNICAL DATASHEET Incremental Encoder RI 58-H

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Relative and absolute pressure switch type 529

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Combi switchbox with integrated 3/2 way pilot valve

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Electronic Pressure Switch EDS 3000

Cable Plug acc. to DIN EN , Form A

W150: Miniature photoelectric switch series with completely integrated electronics

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

Industrial Bar Code Scanners

BTL5-S1 -M -HB/WB-FA /F -C Micropulse Linear Transducer - Rod Style

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Cross-beam scanning system to detect slim objects. 100 mm in

BTL5-P1 _-M -HB/WB-FA /F -C Micropulse Linear Transducer - Rod Style

How To Use A Flowmeter

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

KA/8000/M, KA/8000, ISO cylinder (Stainless steel) Magnetic & Non-magnetic piston, double acting

Relative pressure transmitter type 520

QR12 (1.22 ) Diameter Optical Encoder

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Liquid Level Limit Switch liquiphant T FTL 20

Multifunction devices

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Encoders. the incremental encoders format such as relective optical technology, transmissive optical technology

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

RM/55401/M, Roundline cylinder Magnetic piston, double acting

LED...A Q Series Sealed High-Intensity

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

Adjustment functions for both span and shift have been incorporated

Digital display DA 48

Thermal-Magnetic Circuit Breaker M1-..

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

Pressure and flow control system

HF series Hall effect joysticks

FASTON Terminals and Connectors

INTMOD485-LH Protocol Converter

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensor Accessories

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

+ Incremental interface

Series 6000 Torque measured metal bellow coupling

PAJ GROUP DEVELOPMENT OF ADVANCED MECHATRONICS

REGTRONIC OPERATING INSTRUCTIONS

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Product Information. HMC 6 Hybrid Motor Cable

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

OEM-EP Pressure Controllers

Reaction Torque Sensor

Transcription:

MGNETOSTICTIVE TRNSDUCER MZ Series Key-Features: Content: Technical Data...2 Technical Drawing...3 Electrical Connection...5 Order Code...7 Options & ccessories...8 - vailable measurement ranges from 50-4000 mm - Distance and speed (with CNopen) measurement - Displacement speed up to 10 m/s - Linearity up to ±0.02 % - Working pressure up to 350 bar - Working temperature -30...+75 C - Magnetic cursor, or floating cursor for liquids - Protection class IP67 - Output signals: nalog, SSI, CNopen 15.07.13

- 2 - TECHNICL DT Model MZ- MZ-C MZ-S Measurement range [mm] 50/ 100/ 130/ 150/ 200/ 225/ 300/ 400/ 450/ 500/ 600/ 700/ 750/ 800/ 900 1000/ 1250/ 1500/ 1750/ 2000/ 2250/ 2500/ 2750/ 3000/ 3250/ 3500/ 3750/ 4000 Measured dimension position position / speed position Measurement range speed [m/s] - depending on the scale - ccuracy of the speed output [%] - <2 - Protection class IP67 Displacement speed [m/s] 10 Displacement force [N] <1 Maximum acceleration [m/s²] 100 Working pressure [bar] 350 (peek max. 500) Linearity [%] ±0,02 (min. ±0,06 mm) ±0,02 (max. 0,04) ±0,02 (min. ±0,06 mm) * Resolution 16 bit (max. noise 5 mvpp) 5 µm (2 µm on request) 5 µm (2 µm on request) Repeatability [mm] <0,01 Hysteresis <0,01 mm <±0,005 % MR Shock test DIN IEC68T2-27 100 g, 11 ms Vibrations DIN IEC68T2-6 12 g, 10...2000 Hz Position read sampling time (see table below) [ms] 0,5 to 3 1 to 4 1 Max. output value 12 V (at 0...10 V), 30 m (at 4...20 m) Max. current consumption [m] 70 (at 0...10 V), 90 (at 4...20 m) 100 50 Coefficient of temperature [ppm/ C] 100 20 20 Max. output load [kohm] 5 (at 0...10 V), <0,5 (at 4...20 m) RS422/485 Standard Protection against polarity inversion yes Working temperature [ C] -30...+75-30...+75-30...+90 Storage temperature [ C] -40...+100-40...+100-40...+100 Power supply [V] 24, ±20 % Output signal 0...10V, 4...20 m CNopen DS 301 SSI: inär, Gray, 24 bit, 25 bit Electrical connection M12-, M16-connector, cable output M12-, M16-connector, cable output M16-connector, cable output Housing material high grade steel ISI 316 * With option additional linearisation: ±0.005 (min. ±0.015 mm) DIMENSIONS ND SMPLING TIME Sampling time MZ- [ms] 0.5, MR 50...300 mm 1, MR 350...1100 mm 1.5, MR 1200...2000 mm 2, MR 2250...3000 mm 3, MR 3250...4000 mm Sampling time MZ-C [ms] 1, MR 50...1200 mm 2, MR 1200...2400 mm 4, MR >2400 mm Sampling time MZ-S [ms] 1, MR 50...1000 mm 2, MR 1100...2000 mm 4, MR >2000 mm Dimension MZ- [mm] Measurement range + 176.2 Measurement range + 181.2 Dimension MZ-C [mm] Measurement range + 187.2 Dimension MZ-S [mm] Measurement range + 187.2

- 3 - TECHNICL DRWING MZ- Dimension MZ- Measurement range 50 to 1000 mm Version MZ-- MZ-- X 12.2 mm 9.5 mm Measurement range 1250 to 4000 mm MZ-: mounting inside a cylinder for strokes over 1000 mm, the non-active zone (55 mm) becomes 60 mm because the tip includes a M4 threaded hole.

- 4 - TECHNICL DRWING MZ-C, MZ-S Dimension MZ-C, MZ-S Version MZ-C/S- MZ-C/S- X 12.2 mm 9.5 mm MZ-C, MZ-S: mounting inside a cylinder MZ Grounding

- 5 - MGNETIC CURSOR Magnetic cursor C D PCUR022 32.8 13.5 23.9 - PCUR023 32.8 13.5 23.9 11.0 PCUR024 25.4 13.5 - - PCUR026 (for liquids) 52.4 12.0 44.0 - PCUR027 (for liquids) 52.4 15.0 44.0 - Note: PCUR026 and PCUR027 is supplied with kit PKIT036 for floating cursor for liquids. Material PCUR026, PCUR027: high grade steel ISI 316 PCUR022 PCUR023 PCUR024 PCUR026/027 ELECTRICL CONNECTION NLOG OUTPUT Wiring diagram analog output connector output M12 MZ-- connector output M16 MZ-- cable output MZ--F Function MZ-- MZ-- MZ-F connection cable for 5 pole MZ-- 5-pole, M12 6-pole, M16 cable, 7-pole K5P..M-S/SW-M12 Output 1 (position): 0..10 V, 4..20 m 1 1 grey brown GND output 1 (0 V) 2 2 pink white Output 2 (inverse position): 10..0 V, 20..4m 3 3 yellow blue GND output 2 (0 V) 2 4 green white Supply + 5 5 blue grey Supply GND 4 6 white black

- 6 - ELECTRICL CONNECTION OUTPUT CNopen Wiring diagram output CNopen connector output M12 MZ-C- connector output M16 MZ-C- 2 x connector, 5-pole., M12 (m, f) MZ-C-Y cable output MZ-C-F Function MZ-C- MZ-C- MZ-C-Y MZ-C-F connector, 5-pole, M12 connector, 6-pole, M16 2 x connector, 5-pole, M12 (male, female) cable, 4-pole CN L 5 1 5 5 blue CN H 4 2 4 4 white CN GND (n.c.) 1 3 1 1 - n.c. - 4 - - - Supply + 2 5 2 2 red Supply GND 3 6 3 3 black ELECTRICL CONNECTION OUTPUT SSI Wiring diagram output SSI connector output M16 MZ-S- cable output MZ-S-F Function MZ-S- MZ-S-F connector, 6-pole, M16 PVC-cable, 6-pole Data - 1 orange Data + 2 orange / white Clock + 3 green / white Clock - 4 green / white Supply + 5 dark blue / white Supply GND 6 dark blue / white

- 7 - ORDER CODE NLOG OUTPUT MZ nalog output Cable length output F Connector output, M12, 5-pole Connector output, M16, 6-pole Cable output, 7-pole PVC cable F 00 02 05 10 1 meter 2 meter 5 meter 10 meter Measurement range [mm] e.g. 100 Note: Magnetic cursors must be ordered separately (see accessories). nalog output 0...20 m is available on request. E 0...10 V output signal 4...20 m output signal ORDER CODE CNopen OUTPUT MZ CNopen C - 1 0.005 mm resolution (standard) 0.002 mm resolution Connector output, M12, 5-pole Connector output, M16, 6-pole Connector output, 2 x M12, 5-pole Cable output, 4-pole PVC cable Y F Measurement range [mm] e.g. 100 00 02 05 10 Cable length output F 1 meter 2 meter 5 meter 10 meter 1 500 kaud Note: Magnetic cursors must be ordered separately (see accessories). Other aud rates and resolutions are available on request dditional information, like CNopen Data Protocol available on request 1 magnetic cursor 2 magnetic cursors ORDER CODE SSI OUTPUT MZ SSI Connector output, M16, 6-pole Cable output, 6-pole PVC cable S F 00 02 05 10 Cable length output F 1 meter 2 meter 5 meter 10 meter Measurement range [mm] e.g. 100 3 4 Data length 24 it Data length 25 it G inary data code output Gray data code output Note: Magnetic cursors must be ordered separately (see accessories). Other resolutions are available on request 6 additional linearisation Linearity: ±0.005 (min. ±0.015 mm)

- 8 - OVERVIEW ase model, 0...10 V analog output, M12 connector output MZ---50-50 mm MZ---900-900 mm MZ---100-100 mm MZ---1000-1000 mm MZ---130-130 mm MZ---1250-1250 mm MZ---150-150 mm MZ---1500-1500 mm MZ---200-200 mm MZ---1750-1750 mm MZ---225-225 mm MZ---2000-2000 mm MZ---300-300 mm MZ---2250-2250 mm MZ---400-400 mm MZ---2500-2500 mm MZ---450-450 mm MZ---2750-2750 mm MZ---500-500 mm MZ---3000-3000 mm MZ---600-600 mm MZ---3250-3250 mm MZ---700-700 mm MZ---3500-3500 mm MZ---750-750 mm MZ---3750-3750 mm MZ---800-800 mm MZ---4000-4000 mm Options with additional charge on base model ccessories nalog output: PCUR022 magnetic cursor, ø 32.8 F cable output, 7-pole PVC cable, 1 meter PCUR023 magnetic cursor, ø 32.8 with 90 slit E 4...20 m output signal PCUR024 magnetic cursor, ø 25.4 02 cable length 2 meter PCUR026 f loating cursor f or liquids with hole ø 12 05 cable length 5 meter PCUR027 f loating cursor f or liquids with hole ø 15 10 cable length 10 meter CUR022 non-magnetic spacer for mounting PCUR022 cursor CNopen: C measurement range: 50 to 550 mm Connection cable analog output, 5-pole, shielded, connector M12 C measurement range: 600 to 2000 mm K5P2M-S-M12 2 m, connector, straight C measurement range: 2250 to 4000 mm K5P5M-S-M12 5 m, connector, straight Y connector output, 2 x M12, 5-pole K5P10M-S-M12 10 m, connector, straight F cable output, 4-pole PVC cable, 1 meter K5P2M-SW-M12 2 m, connector, angular 02 cable length 2 meter K5P5M-SW-M12 5 m, connector, angular 05 cable length 5 meter K5P10M-SW-M12 10 m, connector, angular 10 cable length 10 meter SSI: Cable for CNopen output, 5-pole, shielded, PUR S measurement range: 50 to 550 mm K5P2M-S-M12-CN connector M12, straight, to coupling M12 S measurement range: 600 to 2000 mm K5P2M-S-M12-CN connector M12, straight, open cable head S measurement range: 2250 to 4000 mm K5P2M--M12-CN female connector M12, straight, open cable head F cable output, 6-pole PVC cable, 1 meter 02 cable length 2 meter Connector 05 cable length 5 meter CON022 connector M16, 6-pole, straight, IP67 10 cable length 10 meter CON023 connector M16, 6-pole, angular, IP67 06 additional linearisation: D5-G-M12-S connector M12, 5-pole, straight, IP67 50 to 500 mm D5-W-M12-S connector M12, 5-pole, angular, IP67 550 to 1000 mm 1100 to 2000 mm 2250 to 4000 mm Subject to change without prior notice. WayCon Positionsmesstechnik GmbH email: info@waycon.de internet: www.waycon.de Head Office Mehlbeerenstr. 4 82024 Taufkirchen Tel. +49 (0)89 67 97 13-0 Fax +49 (0)89 67 97 13-250 Office Köln uf der Pehle 1 50321 rühl Tel. +49 (0)2232 56 79 44 Fax +49 (0)2232 56 79 45