Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC 30 40 B 1 200 S E C W



Similar documents
Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC B S E C W. [previous page #: 2-18; 2-22]

Equipment. Metering. Metering Equipment 1. Contents

Temporary Power Outlet Panels. Selection and Application Guide.

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents

Temporary Power Outlet Panels

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

Distribution Dry Type Transformers

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

Step 1: Application Instructions

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Electrical Service Guidelines

8146/5 Series Breaker Panelboards

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

UNDERGROUND ELECTRIC TEMPORARY SERVICE PANEL

Section 10 Electric Switchboards: 0 Through 600 Volts

TYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Secondary Unit Substations

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

LP Dimming Panels. GRAFIK Systems. Power Equipment. LP Dimming Panels

Retail Reference Guide Answers for infrastructure.

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

TS93 EMR T/PT/TDE. Surface applied door closer

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

Description. Lugs for NEMA Stud Kits a. (2) #6-350 kcmil SUK350TA (1) #2-600 kcmil SUK600TA. (2) # kcmil SUK1000TA.

FLB Series Circuit Breakers and Enclosures

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Introduction. Upon completion of Basics of Load Centers you should be able to: Explain the role of a load center in residential power distribution

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

Electrical Code Regulation

MCC Ratings. Voltage Rating

Guideline for Fire Safety Elements of Solar Photovoltaic Systems July 17, 2008 Rev: 1/1/10

Remote Power Panels with Breakers

Type 1, 3, & 3R Enclosures

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

NEW SERVICE INSTALLATION STEPS. Common Slow Downs. Other Necessary Steps

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Customer Purchased Meter Sockets & Metering Equipment

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE

Please check with your local inspection authority for any additional requirements before installation.

Argus Technologies Pathfinder10kW to Cordex3.6kW Shelf Replacement Procedure

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

LIEBERT VNSA Installation Sheet

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Approved Meter Sockets and Cabinets

The complete range of consumer switchboards and switchgear

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

Flextec 450 PARTS LIST FOR RETURN TO MAIN INDEX

ASCO SERIES 185 Power Transfer Switches

INSTALLATION INSTRUCTIONS 24" (61.0 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

Circuit Breakers. NRC Series. NRC Series

EDS / EFS Series Control Stations

Section 5 Meters and Service Entrance Equipment

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

SERVICE - GENERAL Residential, Commercial, Industrial

PERMIT APPLICATION REQUIREMENTS FOR RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEMS

Power Distribution & Terminal Blocks

Contractors Guide Central Inverter System Installation

Listed are common requirements that apply to existing solar installations when altered, added to or reconfigured.

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

LOXONE 12 Channel Amplifier

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

LCP Coordination Panel Operations & Maintenance Manual Table of Contents

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

GUE, GUB Junction Boxes

INSTALLATION INSTRUCTIONS

Distribution Dry Type Transformers

APC 3Phase Power Distribution

Transformers from 25va to 500kva. Standard despatch in days not weeks

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

Terminal Blocks 9080LBA Power Distribution Blocks Copper or Aluminum Wire

The Ultimate Load Center Features INSTA-WIRE neutrals and grounds provide quick and easy neutral conductor installation 2

Mini Power-Zone Unit Substation

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

PX100 MBP with Configurable Distribution

Fabrication Illustration Part No. Description Door Frame. P092 Mortised Butt Hinge P092D P092F (includes P2092 $ 48 $ 21 frame/door reinforcing)

METERING INSTALLATION REQUIREMENTS

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

ELECTRICAL INSPECTION BULLETIN (Effective )

Zenith Series MDU & RDU. Critical Power Distribution Units

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Duke Energy Carolinas. Inverter Based Generation Interconnection

Crown Jewel Telephone entry system

HM-W536 Install Guide

HMI display Installation Guide

COLOR VIDEO DOOR PHONE CDV-71BE/D

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Transcription:

Centers Combination Catalog Number Logic Combination Sockets MC 30 40 B 1 00 S E C W ere (max. circuits) (max. 1" breakers) MM = MC = Load Center Combination 1 = 1-Phase 3 = 3-Phase ML or L = Lug MB or B = F/S = Flush / Surface Mounting R = (blank = ring type) E = Approved D/C = UG Feed Only / feed J = B = A = Aluminum Enclosure H = Double L = Lever Socket M = Field Addable Sub Feed N = OH Only Lug T = Feed Thru Lugs W = Wide Load Center Design X = Larger Section Z = OH Feed, Load out Bottom Only Special Suffixes: GA = Georgia Power Compliant CS = Comb. Feed with Test Block DS = UG only Feed with Test Block E = Back-to-back with External Disconnect and Internal Load Center EY = Commercial Test Block with OH only Feed CEY = Commercial Test Block with OH and UG Feed -0

Centers Combination Introduction s Load Center s Siemens s are UL Listed and available from 100A to 400A services. These s utilize a cost effective construction that is preferable in non- areas. ad Center mbo Welcome to the Combination Socket Section. s This section includes 4 product categories, Load Center which each include their own set of featured products. Look for the icons below to help explain the application s and design of products on that Load page. Center Combo s s Siemens s are UL Listed and available from 100A to 400A services. These meter mains utilize designs that meet requirements. Two constructions are available. s Combo Construction Combo These Siemens s feature s a classic Load Center Construction over-under construction. Available in 100A and These Siemens s have a side-by-side 15A versions. construction that is slightly larger in order to Load Center meet requirements. Construction s These s utilize a cost effective sideby-side construction. s combine s 400A 400A Construction These Siemens s have side-by-side a socket to the left and main circuit breaker construction that meets design, and Combo section to the right. The s main breaker section Load Center provide 400A service. includes to 6 circuits. Load Center 400A Load Center s Load Center Siemens Load Center offer several Siemens Load Center offer several different configurations and include a meter socket section and different configurations to meet a variety of installer demands. a load center section. s s These combos feature a cost effective Load Center Load Center These Combo Siemens combos feature designs that meet construction that is preferable in non- areas. requirements. Load Center Load Center Combination Construction Between the Studs Construction 14 14 Full Load Center These Siemens Load Center These Combos have a full width load center 400A feature a over-under s configuration section above, and a meter socket section with a unique trough allowing service from either below, in a 14.3" wide configuration that allows ad Center overhead or underground 400A to the device. flush mounting between typical 16" on center Combo stud construction. Surface mounting options Combo Construction 14 Load Center 14 available. Full Load Center 400A 14 14 Full Load Center These Siemens Load Center feature a classic over-under Between the Studs Construction ions Load Center construction, but are for overhead feed only. These combos have a half width load center s 400A section to the right and a meter socket section Construction to the left, in a 14." wide configuration that mbo Load Center 400A These Siemens Load Center allows flush mounting between typical 16" on have a side-by-side configuration. center stud construction. Surface mounting Load Center options available. der -By-Side 400A Combo Off-set Constuction 400A These Siemens Load Full Center Load Center feature an offset meter to increase room for pulling conductors. 14 14 Load Center 400A 400A 14 14 Full Load Center 400A Full Load Center Construction These Siemens Load Center have a full width load center section to the right, and a meter socket section to the left. The overall width make this combo best suited for surface mounting. 400A 400A Side- Sid 14 14 er 14 14 e 14 Full Load Center 400A Full Load Center Full Load Center 400A 400A 400A Construction These Siemens s have side-by-side construction that meets design, and provide 400A service. Available with 16 to 4 circuits. -1 RC

s Load Center s Centers Surface Mount -s, 1-Phase, 3-Wire 10/40V AC n UL listed n bypass and jaw available as noted n Side hinged door with one screw removal where shown n Suitable for use only as service entrance equipment n AIC rated, or as noted n RX type (or) HD type hub provision on top end wall as noted n Contact local utility to confirm meter socket placement prior to installation n See end of section for dimensions and wiring diagrams s MM00B100JLX 400A Load Center Combo 00A meter main with lever bypass s Load Ce MM00B100RJBX MM0406L100H MM00B100 MM0404L1400RLM 14 14 Full Load Center 400A 14 Side-By 15, 150, and 00A meter main (factory installed), side hinge door. Catalog Number 00A meter main (field added), side hinge door 15 and 00A meter mains, side hinge door 400A meter main, side hinge door, provisions for two field installed mains - with Field, Style, 100-15amp MM00ML1100S 100 OH 18.0 7.4 4.0 QP type 10,000 RX MM00ML115H 15 17.0 16.0 5.0 QP(H) type -RX EC5J - with Factory, 15-00amp (Side-by-Side construction) MM00B1150 150 QN150H MM00B1150R 17.0 16.0 5.0 RX EMC5J MM00B100 00 QN00H MM00B100R MM00B115RJB 15 Q15H MM00B1150RJB 150 16.0 5.0 QN150H MM00B100RJB 00 QN00H 17.0 RX MM00B115RJBX 15 Q15H MM00B1150RJBX 150 18.5 5. QN150H MM00B100RJBX 00 QN00H - with Field & Subfeed up to 00amp (Side-by-Side construction) MM0406L100H 17. 5.0 MM0406L100RH EMC5J 00 4 6 19.8 1-QN or MM0406L100RGA 1.8 5.0 -QP type -RX MM0406L100RHJB 17. 5.0 - with Lever,, 00-400amp (Side-by-Side construction) MM00B100JLX 00 1.1 17. 5.3 QN00H MM0404L1400RLM HQ Lever 9.0 7.0 6.0 30 MM0404L1400SDL 40.0 30.0 6.5 Over/Under Side-by-Side () QN(R), QN(R)H, QP, QPH () s for QN or QP type HD Georgia Power approved H35815- -

s s Load Center Load Center Centers Combo Combo Surface Mount, Over/Under -Load Center Combination, 1-Phase, 3-Wire 10/40V AC n UL listed n Overhead and underground feed applications n Load wires bottom or back exit only n AIC rated, or as noted MC0606L100R MC0408B1150T MC0816B100RTD Revised 1/15/11 n Side hinge doors removable by backing out only one screw n Suitable for use only as service s entrance equipment s n Contact local utility to confirm meter socket placement prior to installation n See end of section for dimensions and wiring diagrams 400A MC040B100JLC 400A Load Center Load Center Side-B 14 14 Full Load Center 400A 00A, main lug, 6 circuit (Twelve 1" spaces), for use with up to six -pole breakers 150 or 00A, main breaker, four 1" spaces, feed thru lugs provided 00A offset design with feed thru lugs 14 14 Full Load Center 00A meter load center wtih lever bypass 400A Catalog Number -Load Center Combination, 150-00amp MC0408B1150T 150 MC0408B1150RT 4 8 30.0 14.0 5.0 RX EC5J MC0408B100T 00 MC0408B100RT MC0816B1150CT 150 MC0816B100CT 00 RX EC5J MC0816B1150RCT 150 8 16 3.0 14.0 5.0 MC0816B100RCT 00 MC0816B1150RJBT 150 MC0816B100RJBT 00 MC0816B1150T 150 QN150RH MC0816B100T OH 8 16 9.0 1.0 5. QN00RH RX EMC5J 00 MC0816B100RT QN00RH MC040B1150RC 150 EC5J MC040B100RC 00 0 40 36.0 14.0 5.0 RX MC040B1150RJBC 150 MC040B100RJBC 00 MC0606L100R EC5J MC0606L100RA 7.0 14.0 5.0 00 1 6 Lug RX MC0606L100RJB MC0606L100RN 9.0 1.0 5. EC5J -Load Center Combination, 150-00amp, Sidewire (Underground Feed Only) MC0606L100RAD 00 UG 6 6 5.0 17.0 5. Lug 10,000 MC0816B100RTD 8 16 9.0 -Load Center Combination, 15-00amp, Lever MC0816B1150JLT 150 8 16 MC0816B100JLT 00 HQ Lever 3.1 14.3 5. MC14B115JLC 15 MBK15 1 4 MC14B100JLC 00 MC040B1150JLC 150 HQ Lever 0 40 36.1 MC040B100JLC 14.3 5. 00 MC304B100JLC 30 4 4.1 -Load Center Combination Approved for Georgia Power, 150-00A MC0408B1150RGA 150 4 8 33.5 MC0408B100RGA 00 MC0606L100RGA 1 6 30.5 15.0 5.1 Lug MC0816B1150RGA 150 8 16 35.5 MC0816B100RGA 00 No main breaker provided. Accepts QN or QP type or 4-pole breakers. Suitable for use as service entrance equipment when not more than six disconnecting means are provided and when not used as a lighting an appliance panel board. EC5J EC5J Due to wire space restrictions on the trough side, the left side of the interior is limited to a 60A max branch. Aluminum enclosure. Feed thru lugs included. -3

s Load Center Centers Surface Mount, Side-by-Side -Load Center Combination, 1-Phase, Combo 3-Wire 10/40V AC n n UL listed Contact local utility to confirm meter socket approval prior n AIC Rated to installation n s See end of section for dimensions and wiring diagrams n Side hinge doors removable by backing out only one screw n Suitable for use only as service entrance equipment MC0816B100TH (shown) MC0816B1XXX(R)TH MC0816B1400RLTM MC0816B1350RLTM MC304B1400SDL 400A MC44B1400SDB Load Center 00A feed, 8 circuit, with feed thru lugs. One factory installed main, provisions for up to 00A field 14 400A meter 14 load center Full Load Center installed main, 8 circuits, lever combination, 30 space/ bypass. 40 circuit lever bypass 400A 400A bolt in K4 socket with 400A main Catagory Number -Load Center Combination, 150-00amp, Full Loadcenter Width MC0816B1150TH 150 QN150RH MC0816B100TH 00 QN00RH 8 16 1.0.9 5.0 MC0816B1150RTH 150 QN150RH MC0816B100RTH 00 QN00RH MC040B1150 150 QN150RH MC040B100 00 QN00RH 0 40 18.0.9 5.0 MC040B1150R 150 QN150RH MC040B100R 00 QN00RH -Load Center Combination, 350-400amp, Lever -RX EMC5J RX EMC5J HD H35815- -Load Center Combination, 400amp, Lever, Underground Feed Only MC0408B1400RLTM HQ Lever MC0816B1350RLTM 30 4 8 8 16 9.0 7.0 6.0 QN00H QN150H MC0816B1400RLTM 8 16 QN00H MC0816B1400SDL HQ 8 16 Lever 30 UG MC304B1400SDL 30 4 39.7 30. 6.4 (1) QN & s for (1)QN or (1)QP HD H35815- -Load Center Combination, 400amp, K4 Bolt-In Socket, Underground Feed Only MC44B1400SDB 4 4 Bolt In 400 K4 UG No MC304B1400SDB 30 4 39.7 30. 6.4 Factory JXD6 Factory QN00RH Field QP(H), QNR(H) HD Feed thru lugs included. Bolt-in meter socket. This device should not be confused with class 30amp lever bypass devices. Device can not be converted to lever bypass. Installer should ensure device approval prior to installation. -4