Electromagnetic Compatibility (EMC) Low-Frequency Standards. Standards on Low-Frequency Emission: IEC 61000-3-2



Similar documents
UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES

Product Data Bulletin

Introduction. Harmonics and IEEE 519 Page 1 of 19

HARMONICS AND HOW THEY RELATE TO POWER FACTOR. W. Mack Grady The University of Texas at Austin Austin, Texas 78712

CERN Accelerator School. Electrical Network and Power Converters. Hans Ulrich Boksberger Paul Scherrer Institute 5232 Villigen PSI Switzerland

Power Quality Centre VOLTAGE FLUCTUATIONS IN THE ELECTRIC SUPPLY SYSTEM. Technical Note No. 7 August 2003

POWER SYSTEM HARMONICS. A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS

Chapter 4 AC to AC Converters ( AC Controllers and Frequency Converters )

Laboratory and field measurements of the power factor and the harmonic emission from energy-efficient lamps

Chapter 4 Using Line Power Analysis

High Frequency Power Quality

Chapter 4: Power Factor Correction

Interpreting IEEE Std 519 and Meeting its Harmonic Limits in VFD Applications

Power System Harmonics

STRATO LED Drivers 70W, Single output

Fundamentals of Power Electronics. Robert W. Erickson University of Colorado, Boulder

How To Limit Voltage Unbalance

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

The Importance of the X/R Ratio in Low-Voltage Short Circuit Studies

HARMONIC DISTORTION IN THE ELECTRIC SUPPLY SYSTEM

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Analysis of AC-DC Converter Based on Power Factor and THD

Harmonic components: electrical network polluters. LV and MV networks are becoming increasingly polluted by current and voltage harmonics. Harmonics a

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC x

GUIDE FOR TESTING POWER TRANSFORMERS

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Testing of Power Transformers. Routine tests, Type tests and Special tests

Diode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off.

Application Guide. Power Factor Correction (PFC) Basics

Energy Management Energy Meter Type EM23 DIN

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Digital Clamp-on DMMs with uncompromising performance

INTEGRATED CIRCUITS DATA SHEET. TDA7000 FM radio circuit. Product specification File under Integrated Circuits, IC01

Quick Connect. quick - simple - efficient.

Three-phase monitoring relay CM-PFE

Power Meter Series 700

Smart Grid and Renewable Energy Grid Integration. Jian Sun, Professor and Director Department of ECSE & Center for Future Energy Systems

Harmonics in your electrical system

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

Improvements of Reliability of Micro Hydro Power Plants in Sri Lanka

Chapter 24. Three-Phase Voltage Generation

Impedance Matching and Matching Networks. Valentin Todorow, December, 2009

APPLICATION NOTE TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION. Abstract.

Survey of Harmonics Measurements in Electrical Distribution System of a Technical Institution

15 Series - Electronic step relay and dimmer. Features SERIE

FREQUENCY CONTROLLED AC MOTOR DRIVE

IEC and CISPR Standards

BXR 300C BXR 300R. Owner, s Manual P/N

Session 10: General Overview of Interconnection Standards & Grid Codes for High Penetration PV October 21, 2015 Santiago, Chile

DS 600. A contact free flux gate based current measurement sensor 600A rms

Mathematical Modeling and Dynamic Simulation of a Class of Drive Systems with Permanent Magnet Synchronous Motors

Power Quality Standards for Electric Service

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Simulation and Analysis of PWM Inverter Fed Induction Motor Drive

C Standard AC Motors

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

DC TRANSMISSION BASED ON VOLTAGE SOURCE CONVERTERS

7-41 POWER FACTOR CORRECTION

INTEGRATED CIRCUITS DATA SHEET. TDA W BTL mono audio amplifier. Product specification File under Integrated Circuits, IC01

CONSTRUCTING A VARIABLE POWER SUPPLY UNIT

Harmonic Distortion and Variable Frequency Drives

Power Quality in Isolated Systems, Requirements and Examples Analysis.

RECOMMENDATION ITU-R BS.704 *, ** Characteristics of FM sound broadcasting reference receivers for planning purposes

SINEAX U553 Transducer for AC Voltage

The Facts About Harmonics and Power Factor. Power Quality: Harmonics & Power Factor Correction

Power Electronics. Prof. K. Gopakumar. Centre for Electronics Design and Technology. Indian Institute of Science, Bangalore.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

DIODE CIRCUITS LABORATORY. Fig. 8.1a Fig 8.1b

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Control of a Three Phase Induction Motor using Single Phase Supply

VARIABLE FREQUENCY DRIVE OPERATION AND APPLICATION OF VARIABLE FREQUENCY DRIVE (VFD) TECHNOLOGY

Power System Harmonic Fundamental Considerations: Tips and Tools for Reducing Harmonic Distortion in Electronic Drive Applications

PCM Encoding and Decoding:

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

0.9V Boost Driver PR4403 for White LEDs in Solar Lamps

Positive Feedback and Oscillators

Application Note AN- 1095

INFO. Legally binding regulations on relating to energy efficiency and environmental protection. Eco-Design Directive and EC-Commission Regulation

SIZING THE PRIMARY POWER SYSTEM FOR RESISTANCE WELDERS

On-site Measurement of Load and No-load Losses of GSU Transformer

Chapter 6: Converter circuits

Design a Phase Interleaving PFC Buck Boost Converter to Improve the Power Factor

Neutral Currents in Three Phase Wye Systems

An Efficient AC/DC Converter with Power Factor Correction

LM1036 Dual DC Operated Tone/Volume/Balance Circuit

Current and Temperature Ratings

DATA SHEET. TDA1543 Dual 16-bit DAC (economy version) (I 2 S input format) INTEGRATED CIRCUITS

Custom Products. Magnetic Components. Vishay Dale.

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Welcome to this presentation on Driving LEDs AC-DC Power Supplies, part of OSRAM Opto Semiconductors LED Fundamentals series. In this presentation we

Engineering Sciences 151. Electromagnetic Communication Laboratory Assignment 3 Fall Term

PM734F - Technical Data Sheet Winding 28

IEC Self-ballasted compact fluorescent lamps for general lighting services - performance requirements Contents

AN ULTRA-CHEAP GRID CONNECTED INVERTER FOR SMALL SCALE GRID CONNECTION

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Dual Chamber Temporary External Pacemaker

Transcription:

Electromagnetic Compatibility (EMC) Low-Frequency Standards Summary IEC 61000-3-2: Limits for harmonic current emissions (equipment input current 16A per phase) IEC 61000-3-4: Limitation of emission of harmonic currents in low-voltage power supply systems for equipment with rated current greater than 16 A per phase Standards on Low-Frequency Emission: IEC 61000-3-2 Goal: limitation of harmonic components of the input current impressed on the public low-voltage supply system, for equipment with input current 16 A per phase Equipment to be connected to 220/380 V, 230/400 V and 240/415 V systems operating at 50 Hz or 60 Hz No limits for systems with nominal voltage less than 220 V (line-to-neutral) Four categories of equipment Absolute and/or relative limits (relative limits based on input power) Page 1

IEC 61000-3-2: Measurement Circuit Single-phase equipment Three-phase equipment Z S G M S Z M I n U EUT G G G Z S Z S Z S Z S L 1 L 2 L 3 N M Z M Z M Z M Z M I n I n I n U EUT S IEC 61000-3-2 Supply Source Requirements Test voltage U at the EUT s terminals: rated voltage of the equipment. In the case of voltage range, use 230/400 V for single-phase and three-phase supply voltage accuracy within ± 2 % of the nominal value frequency accuracy within ± 0.5 % of the nominal value displacement accuracy between each pair of phases of a three-phase source within ± 1.5 peak value of the test voltage shall be within 1.40 and 1.42 times its RMS value and shall be reached within 87 to 93 after the zero crossing (not applicable to class A and B equipment) Page 2

IEC 61000-3-2 Supply Source Requirements With EUT connected, the harmonic ratios of test voltage shall not exceed: Limits Harmonic order 0,9% 3 0,4% 5 0,3% 7 0,2% 9 0,2% even, from 2 to 10 0,1% from 11 to 40 Voltage drop on input impedance Z M shall not exceed 0.15V peak IEC 61000-3-2 Measurement Equipment Requirements Any type of wave analyzer may be used (frequency-domain instrumentation using selective amplifier, heterodyne, multiple passive filters, spectrum analyzer tuned to the frequency to be measured, and timedomain instrumentation using digital filters or Discrete- Fourier-Transform DFT) Annex B of IEC 61000-3-2 reports requirements for measurement equipment Page 3

IEC 61000-3-2 Classification of Equipment Class A: balanced 3-phase equipment (r.m.s. line currents differing less than 20 %) and all other equipment, except those in the following classes Class B: portable tools Class C: lighting equipment including dimming devices with active input power above 25 W Class D: equipment having an input current with a "special wave shape" and a fundamental active input power between 75 and 600 W. Whatever the wave shape of their input current, Class B, Class C, and provisionally motor-driven equipment are not considered as Class D equipment IEC 61000-3-2 Class D equipment: Special Wave Shape Each half cycle of input current is within the envelope for at least 95% of the time Page 4

Classification of Equipment Class B Class C Bal. 3-phase equipment? no yes Portable tool? no yes Lighting equipment? yes no Class A no Special waveshape (P 600W)? yes Class D no Motor driven? yes IEC 61000-3-2 - Harmonic Limits Class A and Class B Harmonic order n Odd harmonics 3 5 7 9 11 13 15 <= n <= 39 Even harmonics 2 4 6 8 <= n <= 40 Class A max permissible harmonic current A 2.30 1.14 0.77 0.40 0.33 0.21 2.25/n 1.08 0.43 0.30 1.84/n Class B max permissible harmonic current A 3.45 1.71 1.155 0.60 0.495 0.315 3.375/n 1.62 0.645 0.45 2.76/n Page 5

IEC 61000-3-2 - Harmonic Limits Class C > 25 W Harmonic order n 2 3 5 7 9 11 <= n <= 39 Maximum value expressed as a percentage of the fundamental input current of the luminaries 2 30 λ* 10 7 5 3 *l is power factor IEC 61000-3-2 - Lighting Equipment Independent Dimming devices shall comply with class A. Where phase control is used on incandescent lamps, the firing angle shall not exceed 145 Built-in dimming devices for incandescent lamp class A limits shall be satisfied. Where phase control is used, the firing angle shall not exceed 145 for discharge lamps class D limits apply Page 6

IEC 61000-3-2 - Harmonic Limits Class D (Rated load condition) Harmonic order n 3 5 7 9 11 13 15 <= n <= 391 75 W < P < 600 W ma/w 3.4 1.9 1.0 0.5 0.35 0.296 3.85/n P > 600 W A 2.30 1.14 0.77 0.40 0.22 0.21 2.25/n No limits apply for equipment below 75 W input power Harmonic Current Measurements No limits apply for high power equipment (> 1 kw) for professional use (equipment for use in trades, professions, or industries not intended for sale to the general public) For harmonics of the order above 19, if the current spectrum envelope shows a monotonic decrease of the increasing order harmonics, measurement can be restricted to the first 19 harmonics Harmonic currents less than 0.6 % of the input current measured under the test conditions, or less than 5 ma, whichever is greater, are disregarded Page 7

Harmonic Current Measurements The limits are applicable to steady-state harmonic currents For transitory harmonic currents the following applies: harmonic current lasting for no more than 10 s when a piece of equipment is brought into operation or is taken out of operation, manually or automatically, are disregarded the limits apply to all other transitory harmonic currents occurring during the testing of equipment or parts of equipment. For transitory even harmonic currents of order from 2 to 10 and transitory odd harmonic currents of order from 3 to 19, values up to 1.5 times the limits are allowed for each harmonic during a maximum of 10% of any observation period of 2.5 min IEC 61000-3-2: Comments High crest-factor waveforms are penalized (Class D) in order to reduce peak-clipping effect. If line-voltage distortion will not improve in the future, the lower power limit of class D will be reduced from 75 W to 50 W Even harmonics are penalized in order to reduce asymmetry Below 600 W class A limits are less severe than Class D. Consider changing the input current waveform Requirements for lamps above 25 W are severe, below 25 W there is presently no limit Page 8

Test Conditions Particular test conditions are specified for the following equipment: Television (TV) receiver (both colour and monochrome) Audio amplifiers Video-cassette recorders Lighting equipment Incandescent lamp dimmers Vacuum cleaners Washing machines Microwave ovens Information technology equipment (ITE) Induction hobs For other equipment, user s operation controls or automatic programs shall be set to produce the maximum harmonic components under normal operating conditions for each successive harmonic component in turn Harmonic Pollution Tests Diode Rectifier supplying a Three-Phase Inverter Power: 3,500 W, Voltage: 400 V, 50 Hz, Switching frequency: 18 khz Class A A r.m.s. 4,5 4 3,5 3 2,5 2 1,5 1 0,5 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 Harmonics Limit Measurements Harmonic emission of phase A Page 9

Technical Report on Low-Frequency Emission: IEC 61000-3-4 Limitation of emission of harmonic currents in low-voltage power supply systems for equipment with rated current greater than 16 A per phase IEC 61000-3-4 IEC 61000-3-4 extends the field of application of previous standard IEC 61000-3-2, for electrical and electronic equipment with a rated input current exceeding 16 A per phase Equipment to be connected to public low-voltage a.c. distribution systems of the following types: nominal voltage up to 240 V, single-phase (two or three wires) nominal voltage up to 600 V, three-phase (three or four wires) nominal frequency 50 Hz or 60Hz Two methods for type tests are allowed: direct measurement of emission calculation of the emission by validated simulations Page 10

IEC 61000-3-2 Measurement Circuit Single-phase equipment Three-phase equipment DU L L 3 DU L Z L Source L U N Z L Z N EUT Source L 2 L 1 U Z L Z L EUT DU N N Z N DU N IEC 61000-3-2 Supply Source Requirements Test voltage U at the source s terminals: rated voltage of the equipment. In the case of voltage range, use 230 V for single-phase or three-phase supply (400V line-line) voltage accuracy within ± 2 % of the nominal value frequency accuracy within ± 0.5 % of the nominal value displacement accuracy between each pair of phases of a three-phase source within ± 1.5 peak value of the test voltage shall be within 1.40 and 1.42 times its RMS value and shall be reached within 87 to 93 after the zero crossing voltage drop DU (DU = DU L + DU N or DU = 2DU L ) shall not exceed 0.5 V peak Page 11

IEC 61000-3-2 Supply Source Requirements With EUT connected, the harmonic ratios of test voltage shall not exceed: Limits Harmonic order 0,9% 3 0,4% 5 0,3% 7 0,2% 9 0,2% even, from 2 to 10 0,1% from 11 to 40 IEC 61000-3-4: Definitions Point of common coupling (PCC): point in the public network which is closest to the consumer concerned and to which other consumers are or may be connected Partial weighted harmonic distortion (PWHD): PWHD I n Ł I Short-circuit power (S sc ): calculated from the nominal system voltage U nom and the impedance Z at the PCC S = sc = 40 n n= 14 1 ł 2 nom U Z 2 Page 12

IEC 61000-3-4: Definitions Rated apparent power (S equ ): calculated from the rated r.m.s. line current I equ of the piece of equipment and the rated voltage U p (single phase) or U i (interphase) S S S S equ equ equ equ = Up Iequ For single-phase equipment = U I = i = 3U equ 3 U I p i I equ equ_max For interphase equipment For balanced three-phase equipment For unbalanced three-phase equipment (I equ_max is the maximum of the r.m.s. currents flowing in any one of the three phases) IEC 61000-3-4: Definitions Short-circuit ratio (R sce ): R R R sce sce sc sc ( 3 Sequ) ( 2 S ) sce = Ssc For single-phase equipment = S = S S equ equ For interphase equipment For all three-phase equipment Page 13

IEC 61000-3-4: Connection Procedures Stage 1 - Simplified Connection: equipment complying with stage 1 limits can be connected at any point of the supply system provided the short-circuit ratio R sce is 33 Stage 2 - Connection based on Network and Equipment Data : for equipment not complying with stage 1 limits, higher emission values may be allowed, provided the short-circuit ratio R sce is 33 Stage 3 - Connection based on the consumer s agreed power: if the conditions of neither stage 1 nor stage 2 are fulfilled, or if the input current of the equipment exceeds 75 A, the supply authority may accept the connection of the equipment on the basis of the agreed active power of the consumer s installation. The local requirements of the power supply authority apply in this case IEC 61000-3-4: Connection Procedures Stage 1 current emission values for simplified connection of equipment (S equ S sc / 33) Harmonic number n Admissible harmonic current I n /I 1 * % 3 21.6 5 10.7 7 7.2 9 3.8 11 3.1 13 2 15 0.7 17 1.2 19 1.1 Harmonic number n Admissible harmonic current In/I1 * % 21 0.6 23 0.9 25 0.8 27 0.6 29 0.7 31 0.7 33 0.6 Even 8/n or 0.6 * I 1 = rated fundamental current; I n = harmonic current component Page 14

IEC 61000-3-4: Connection Procedures Stage 2 current emission values for single-phase, interphase and unbalanced three-phase equipment Minimal R sce Admissible harmonic current distortion factors % Admissible individual harmonic current I n /I 1 * THD PWHD I3 I5 I7 I9 I11 I13 66 25 25 23 11 8 6 5 4 120 29 29 25 12 10 7 6 5 175 33 33 29 14 11 8 7 6 250 39 39 34 18 12 10 8 7 350 46 46 40 24 15 12 9 8 450 51 51 40 30 20 14 12 10 600 57 57 40 30 20 14 12 10 NOTE 1 The relative value of even harmonics shall not exceed 16/n % NOTE 2 Linear interpolation between successive Rsce values is permitted NOTE 3 In the case of unbalanced three-phase equipment, these values apply to each phase * I1 = rated fundamental current; In = harmonic current component % Minimal R sce Admissible harmonic current distortion factors % IEC 61000-3-4: Connection Procedures Stage 2 current emission values for balanced threephase equipment Admissible individual harmonic current I n /I 1 * THD PWHD I5 I7 I11 I13 66 16 25 14 11 10 8 120 18 29 16 12 11 8 175 25 33 20 14 12 8 250 35 39 30 18 13 8 350 48 46 40 25 15 10 450 58 51 50 35 20 15 600 70 57 60 40 25 18 NOTE 1 The relative value of even harmonics shall not exceed 16/n % NOTE 2 Linear interpolation between successive Rsce values is permitted * I1 = rated fundamental current; In = harmonic current component % Page 15

Harmonic Current Measurements Limits for equipment as specified apply to line currents for all types of power connections and load Harmonic currents below 0.6 % of the input fundamental current, are disregarded harmonic current lasting for no more than 10 s when a piece of equipment is brought into operation or is taken out of operation, manually or automatically, shall not exceed 1.5 times the limit values given for the relevant stage the limits apply to all other transitory harmonic currents occurring during the evaluation of equipment or parts of equipment. For even harmonic currents of order from 2 to 10 and odd harmonic currents of order from 3 to 19, values up to 1.5 times the limits are allowed for each harmonic during a maximum of 10% of any observation period of 2.5 min Requirements for Simulation Assessment of current emission and the corresponding R scemin value can be made by computer simulation of the equipment considered Measurement of the equipment under normal laboratory conditions (set-up as previously specified) Supply voltage U shall have individual voltage harmonics not exceeding 70% of the compatibility levels given in IEC 61000-2-2. Its spectrum, as well as supply impedance (value at the fundamental frequency), shall be recorded Page 16

Requirements for Simulation Simulation performed using measured values of voltage spectrum and supply impedance. It is considered validated if the results from measurement and simulation do not differ of the highest following value: either ± 5 % for each harmonic current measured or ± 0.6 % of the fundamental current Validation of the simulation is considered to be valid if the same type of equipment is studied and if the rated input power differs from that of the tested EUT by no more than ± 25 % Page 17