Optical media converter Introduction s The use of fiber optics is advisable when reliability demands are high or there are long distances to cover. One simple and inexpensive solution is the Weidmuller media converter, which can convert an RJ45 port to an optical port with an SC or ST glass fiber connection. The supply voltage can be designed as a redundant system and therefore provides users with high fail-safe security. The conversion of RJ45 copper ports to SC or ST fiber optic ports can be set transparently. Weidmuller Industrial Ethernet media converters provide a solution for industrial applications that require a highly reliable, robust data exchange between copper and glass fiber media. s are cost-effective devices and give users the option of integrating fiber optics into their networks. The Weidmuller media converters are real-time-compatible and remain transparent in the network. Single-mode long-distance cabling Transparent link Pump station 20 km Long-distance cabling of up to 60 km is possible in single-mode with our media converters. Our standard converter features a max. 2-km transmission path in multi-mode and a max. 20-km transmission path in single-mode. The required connection cables can be found in Chapter D.
Optical media converter in RapidRing, with transparent link PLC FO Managed Switch Production facility Managed Switch RapidRing FO FO Managed Switch ecause of their transparent network links, our media converters are well suited for use within a redundant connection in a ring topology. Clearwater.64 Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Optical media converter WaveLine Media Converter Transparent in network For mounting on TS35 Transmission distances up to 60 km Multimode or singlemode 108 22,5 129 % \ " WaveLine Media Converter Weidmuller s media converters can be switched between half duplex and full duplex by means of a small switch. This means they can be used in demanding real-time applications. Thus RapidRing transparency is no problem! The multi-mode version can transmit with no interference for up to 2 km. The single-mode version can transmit up to 20/60 km. Longer transmission capabilities are available on request. Ordering data Number of ports 1 x RJ45 MDI/MDI-X, 1 x SC multi-mode 1 x RJ45 MDI/MDI-X, 1 x SC single-mode 1 x RJ45 MDI/MDI-X, 1 x SC single-mode 60 1 x RJ45 MDI/MDI-X, 1 x ST multi-mode 1 x RJ45 MDI/MDI-X, 1x ST-Singlemode Accessories RJ45 dust-protection plug markers Note Technical data IE-MC-SC-WAVE 8916300000 IE-MC-SC-SM-WAVE 8916290000 IE-MC-SC-SM60-WAVE 8963430000 IE-MC-ST-WAVE 8916310000 IE-MC-ST-SM-WAVE 8958520000 Singlemode design up to 120 km on request IE-DPC 8813490000 WS 15/5 MC NEUTRAL 1609880000 Cables and connection elements are found starting at Chapter C. Housing Plastic V0 Length / Width / Height 108 mm / 22.5 mm / 127.8 mm AC input voltage, min.-max. 10-24 V AC DC input voltage, min.-max. 10-35 V DC AC input power / DC 4 VA AC / 4 Watt DC Input frequency 47-63 Hz Operating temperature, min.-max. 0 C-60 C Storage temperature, min.-max. -40 C-85 C Installation TS 35 Protection class IP 20 Standard IEEE 802.3; 802.3u; 802.3x Data rate RJ45/100m: 100ASE-TX Fiber-optic connection: 100ASE-FX (1310 nm) Multi-mode to 2 km Single-mode to 20/60 km Transparent Segment length Copper 100 m; fiber (multi-mode) 2 km; fiber (single-mode) 20/60 km Status indication Power/data rate, Connection/Activity Approvals culus, Class I, Division 2, CE, EN55024, EN 55022, Gost R Optical budget 8 d for 62.5/125 µm multimode cable 4 d for 50/125 µm multimode cable 13 d for 9/125 µm singlemode cable Supported protocols Profinet RT, Modbus TCP, TCP/IP, EthernetIP Note:
The WaveLine ComServer connects your serial interfaces to your existing network infrastructure in the simplest way possible. An Internet browser is used for the installation of serial and network parameters. Similarly carried out over the Ethernet interface, the configuration is simple and user-friendly. The can be configured directly via the RS232 interface or via the network. With web-based management, a remote configuration is also possible. The IE-CS-1SERIAL-WAVE WaveLine ComServer is available with an RS232 port (not electrically isolated). The IE-CS-2SERIAL-WAVE WaveLine ComServer comes with two RS232 ports ( RS232 and RS-232/422/485 electrically isolated). oth types of WaveLine ComServers feature auto-negotiation and auto-crossing (RJ45) functions as well as redundant power supplies. The ComServer supports the following protocols: TCP/IP, UDP/IP, DHCP, OOTP, HTTP and AutoIP. The Weidmuller WaveLine ComServer comes optionally with the following ports: IE-CS-1SERIAL-WAVE with one RJ45, one RS-232 and IE-CS-2SERIAL-WAVE with one RJ45, one RS- 232, one RS-232/485/422. The operational status of the power, link activity and connection are displayed. oth ComServer types (IP20 protection) have a compact build (length: 108 mm, height: 127.8 mm, width: 22.5 mm or 45 mm). The devices are enclosed in sturdy plastic housings and can be simply snapped on to a TS35 mounting rail. They can operate in temperatures ranging from 0 C to 60 C. Integrate your serial end devices into the industrial Ethernet, using our s Production Facility Control Panel RS232 Our enables you to integrate production facilities (where, for example, only an RS232 interface is available) into the corporate network. The Configurator and the configuration software for the production facility can be installed on a remote PC. The Configurator and the Com port redirector driver allow you to configure the conveniently from a remote location. You can also setup communications with production facilities remotely. This makes it possible to operate the plant in your own network and to carry out maintenance on machinery parts. Clearwater.66 Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
The integration of serial end devices into your industrial Ethernet Inspection of incoming goods Connection to any Ethernet infrastructure It is possible to use our as an interface converter. This enables the data from an RS232 device to be forwarded to a computer on the corporate network. The illustration shows an example application of this interface. For example, a scale located in the warehouse only has a RS232 connection. The goal is to integrate it into the corporate network and allow it to access new software. For this, the can be put to use as a data-exchange interface between the scale s RS232 port and the Ethernet.
compact plastic housing 108 22.5 129 % Our WaveLine is designed to connect your serial end devices to your existing network infrastructure in the simplest way possible. The web front-end allows for user-friendly operation. The can be configured directly via the RS-232 interface of via the network. Ordering data Number of ports 1 x RJ45, 1 x RS232 Accessories markers Note IE-CS-1SERIAL-WAVE 8925640000 WS 15/5 MC NEUTRAL 1609880000 Cables and connection elements are found starting at Chapter C. 8925640000 IE-CS-1SERIAL-WAVE with a RS-232 interface, not electrically isolated Technical data Housing Plastic V0 Length / Width / Height 108 mm / 22.5 mm / 127.8 mm Ports 1x RJ45; 1x RS-232 AC input voltage, min.-max. 10-24 V AC DC input voltage, min.-max. 10-35 V DC Input power AC / DC 6 VA AC/4 Watt DC Input frequency 47-63 Hz Operating temperature, min.-max. 0 C-60 C Storage temperature, min.-max. -40 C-85 C Installation TS 35 Protection class IP 20 Data rate 10 ase-t/100ase-tx (copper); of 300 to 921.600 it/s (RS-232) Functionality Autonegotiation and Autocrossing (RJ45), redundant voltage supply Status indication Data rate, Power, Connection/Activity Transmission rate 300 up to 921600 it/s Approvals culus, Class 1, Division 2, CE, EN55024, EN 55022 Supported protocols TCP/IP, UDP/IP, DHCP, OOTP, HTTP, AutoIP Note: Clearwater.68 Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
compact plastic housing 108 45 129 % Our WaveLine is designed to connect your serial end devices to your existing network infrastructure in the simplest way possible. The web front-end allows for user-friendly operation. The can be configured directly via the RS-232 interface of via the network. Ordering data Number of ports 1 x RJ45, 1 x RS232, 1 x RS232/485/422 Accessories markers Note IE-CS-2SERIAL-WAVE 8925650000 WS 15/5 MC NEUTRAL 1609880000 Cables and connection elements are found starting at Chapter C. 8925650000 IE-CS-2SERIAL-WAVE with two RS-232 interfaces, RS-232 and RS-422/485 electrically isolated Technical data Housing Plastic V0 Length / Width / Height 108 mm / 45 mm / 127.8 mm Ports 1x RJ45; 1x RS-232; 1x RS-232/485/422 AC input voltage, min.-max. 10-24 V AC DC input voltage, min.-max. 10-35 V DC Input power AC / DC 6 VA AC/5 Watt DC Input frequency 47-63 Hz Operating temperature, min.-max. 0 C-60 C Storage temperature, min.-max. -40 C-85 C Installation TS 35 Protection class IP 20 Data rate 10 ase-t/100ase-tx (copper); of 300 to 921.600 it/s (RS-232) Functionality Autonegotiation and Autocrossing (RJ45), redundant voltage supply Status indication Data rate, Power, Connection/Activity Transmission rate 300 up to 921600 it/s Approvals culus, Class 1, Division 2, CE, EN55024, EN 55022 Supported protocols TCP/IP, UDP/IP, DHCP, OOTP, HTTP, AutoIP Note: