Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.



Similar documents
Basic principles and mechanisms of NSOM; Different scanning modes and systems of NSOM; General applications and advantages of NSOM.

5. Scanning Near-Field Optical Microscopy 5.1. Resolution of conventional optical microscopy

Applications of confocal fluorescence microscopy in biological sciences

Near-field scanning optical microscopy (SNOM)

Confocal Microscopy and Atomic Force Microscopy (AFM) A very brief primer...

Chapter 12 Filters for FISH Imaging

Preface Light Microscopy X-ray Diffraction Methods

Chapter 13 Confocal Laser Scanning Microscopy C. Robert Bagnell, Jr., Ph.D., 2012

Zeiss 780 Training Notes

Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications

CREOL, College of Optics & Photonics, University of Central Florida

DOE Solar Energy Technologies Program Peer Review. Denver, Colorado April 17-19, 2007

Acousto-optic modulator

Raman spectroscopy Lecture

It has long been a goal to achieve higher spatial resolution in optical imaging and

PHYSICAL METHODS, INSTRUMENTS AND MEASUREMENTS Vol. IV Femtosecond Measurements Combined With Near-Field Optical Microscopy - Artyom A.

CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL

Scanning Near-Field Optical Microscopy for Measuring Materials Properties at the Nanoscale

Nano-Spectroscopy. Solutions AFM-Raman, TERS, NSOM Chemical imaging at the nanoscale

Fiber Optics: Fiber Basics

Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff

Lecture 4 Scanning Probe Microscopy (SPM)

Raman Spectroscopy Basics

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

Recording the Instrument Response Function of a Multiphoton FLIM System

Molecular Spectroscopy

Module 13 : Measurements on Fiber Optic Systems

Time out states and transitions

Principles of Microscopy and Confocal and Fluorescence Microscopy

Introduction to flow cytometry

Optical laser beam scanner lens relay system

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Physics 441/2: Transmission Electron Microscope

Confocal Microscopy. Chapter 2

NEAR FIELD OPTICAL MICROSCOPY AND SPECTROSCOPY WITH STM AND AFM PROBES

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

Experiment 5. Lasers and laser mode structure

Confocal Fluorescence Microscopy

Introduction to Fourier Transform Infrared Spectrometry

Synthetic Sensing: Proximity / Distance Sensors

Advanced Research Raman System Raman Spectroscopy Systems

Introduction to Flow Cytometry

Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012

Infrared Viewers. Manual

LabRAM HR. Research Raman Made Easy! Raman Spectroscopy Systems. Spectroscopy Suite. Powered by:

LabRAM HR Evolution. Research Raman Made Easy!

Using light scattering method to find The surface tension of water

The Basics of Scanning Electron Microscopy

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University

Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES

Microscopy: Principles and Advances

Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014

Automatic and Objective Measurement of Residual Stress and Cord in Glass

Neuro imaging: looking with lasers in the brain

Copyright by Mark Brandt, Ph.D. 12

Holographically corrected microscope with a large working distance (as appears in Applied Optics, Vol. 37, No. 10, , 1 April 1998)

Ion Beam Sputtering: Practical Applications to Electron Microscopy

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Components for Infrared Spectroscopy. Dispersive IR Spectroscopy

ZEISS Microscopy Course Catalog

X-Rays and Magnetism From Fundamentals to Nanoscale Dynamics

MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as:

Physics 10. Lecture 29A. "There are two ways of spreading light: to be the candle or the mirror that reflects it." --Edith Wharton

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

h e l p s y o u C O N T R O L

FTIR Instrumentation

Taking the Confusion out of Confocal Microscopy

Flow cytometry basics fluidics, optics, electronics...

A Brief History of the Microscope and its Significance in the Advancement of Biology and Medicine

3D Raman Imaging Nearfield-Raman TERS. Solutions for High-Resolution Confocal Raman Microscopy.

View of ΣIGMA TM (Ref. 1)

Zeiss Axioimager M2 microscope for stereoscopic analysis.

Webex-based remote instrument control guide

COMPENSATION MIT Flow Cytometry Core Facility

Interference. Physics 102 Workshop #3. General Instructions

A VERYbrief history of the confocal microscope 1950s

Lenses and Apertures of A TEM

RAY TRACING UNIFIED FIELD TRACING

Optical Communications

The excitation in Raman spectroscopy is usually. Practical Group Theory and Raman Spectroscopy, Part II: Application of Polarization

Zecotek S Light Projection Network Marketing

These particles have something in common

Near-Field Scanning Optical Microscopy: a Brief Overview

Nano Optics: Overview of Research Activities. Sergey I. Bozhevolnyi SENSE, University of Southern Denmark, Odense, DENMARK

Reflectance Measurements of Materials Used in the Solar Industry. Selecting the Appropriate Accessories for UV/Vis/NIR Measurements.

CSCI 4974 / 6974 Hardware Reverse Engineering. Lecture 8: Microscopy and Imaging

Robert G. Hunsperger. Integrated Optics. Theory and Technology. Fourth Edition. With 195 Figures and 17 Tables. Springer

Observing a nanomachine at work: Single-molecule imaging or spectroscopy (SMI or SMS)

Polarization Dependence in X-ray Spectroscopy and Scattering. S P Collins et al Diamond Light Source UK

Characterizing Quantum Dots and Color Centers in Nanodiamonds as Single Emitters

Diffraction of a Circular Aperture

Two-photon FCS Tutorial. Berland Lab Department of Physics Emory University

Christine E. Hatch University of Nevada, Reno

LASER SCANNING CONFOCAL MICROSCOPY

Leica TCS SP5 Confocal Laser Scanning Microscope User Guide 1. BASIC IMAGE ACQUISITION

Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory

UNIT I: INTRFERENCE & DIFFRACTION Div. B Div. D Div. F INTRFERENCE

Bio 321 Lightmicroscopy Electronmicrosopy Image Processing

Raman Spectroscopy. 1. Introduction. 2. More on Raman Scattering. " scattered. " incident

Transcription:

Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.

Some limitations (disadvantages) of NSOM A trade-off of high spatial resolution of NSOM Practically zero working distance (for objective) and an extremely small depth of field (for tip). Draw NSOM scheme on board. Extremely long scan times for high resolution images or large specimen areas. Very low transmisivity of apertures smaller than the incident light wavelength --- low intensity of incident light for excitation, a problem for weak fluorescent molecules (challenging for molecules with fluorescence yield < 10%). Only surface features can be imaged and studied --- limiting the application for sandwiched materials or devices (double layer thin films, particles or molecules covered with insulating polymers). Draw a scheme on board. Fiber optic probes are somewhat problematic for imaging soft materials due to their high spring constants, especially in shear-force mode. Feedback system is hard to maintain in liquid. Tips are expensive and hard to reproduce (the aperture size and shape of the apex) --- each time a new tip is used, the whole optical system (e.g. APD) has to be re-adjusted and optimized --- time consuming.

NSOM vs. SCM

NSOM vs. SCM

Optical paths of Scanning Confocal Microscope Co-focus

Confocal: removing scattering light (noise)

A good review on scanning confocal based single-molecule imaging Page 3597

THE 2008 WOLF PRIZE IN CHEMISTRY The Prize Committee for Chemistry has unanimously decided that the 2008 Wolf Prize be jointly awarded to William E. Moerner Stanford University Stanford, California, USA Allen J. Bard University of Texas Austin, Texas, USA for the ingenious creation of a new field of science, single molecule spectroscopy and electrochemistry, with impact at the nanoscopic regime, from the molecular and cellular domain to complex material systems.

Operation modes of SCM 1. Stage (sample) scanning --- tunable from a NSOM set up. Highly desirable for manufacturers of NSOM to compete with SCM optical manufacturers. Installation of a NSOM means an option of SCM. Major advantages: high resolution for scanning (0.1 nm). Slide. 2. Laser scanning --- sample not moving, scanning the laser beam with mirrors. Major advantages: large area scanning and multiple laser excitation for biological systems. Slide. 3. Nipkow disk --- maintaining both the stage and light source stationary, scanning the specimen with an array of light points transmitted through apertures in a spinning. Advantages: selective imaging, minimum damage to sample, no laser required. It is not as common as the first two. Slide.

Laser scanning and Nipkow disk imaging

Mechanism of laser scanning confocal small tilt of laser beam leads to out-of-focus

Laser scanning control system coincident moving of laser beam and optical accessories (e.g. pin holes)

Small illumination volume provides higher spatial resolution.

Fluorescently stained human medulla Fluorescently stained rabbit muscle fibers sunflower pollen grain From Olympus

Resolution and contrast of SCM imaging

3-D imaging by Laser Scanning Confocal Microscopy Only the emission from the focal plane is detected through a pinhole. Synchronized scanning control of the laser beam enables the specimen to be optically sectioned along the z axis. Thus, 3-D imaging is allowable. See slide.

Confocal: layer-by-layer scanning along z-direction

Sunflower pollen grain Chinese hamster ovary (CHO) line mutated with GFP and HIV protein Mouse intestine section labeled with several fluorophores, created from stacking of 45 optical sections. From Olympus

From Olympus

Major optical components of SCM Major instrument component: scanner (stage), laser source (CW, pulsed), detector (PMT, APD, CCD (spectra, color image)). See a slide. Major optical components: 1. Objective --- focusing both excitation and emission. Large NA (numerical aperture) objectives (NA > 1.2) are normally used for efficient collection of emission. 2. Notch filter --- extremely narrow blocking of a specific wavelength (good for lasers). 3. Bandpass Filter --- A filter that transmits a defined region (or band) of wavelengths. 4. Shortpass (SP) Filter --- An optical interference or colored glass filter that attenuates longer wavelengths and transmits (passes) shorter wavelengths. 5. Longpass (LP) Filter --- An optical interference or colored glass filter that attenuates shorter wavelengths and transmits (passes) longer wavelengths. 6. Beamsplitter --- A common optical device used for separating an incident beam of light into two or more components that are subsequently projected in different directions. Beamsplitters are available in a variety of configurations to suit particular requirements. A). Prism beamsplitters, B) polarizing beamsplitters are composed of a crystalline birefringent material to produce linearly polarized light, C) dichromatic (often termed dichroic) mirrors act as beamsplitters to reflect excitation wavelengths back into the source while transmitting longer wavelength secondary fluorescence emission to the eyepieces or detector. 7. Neutral Density (ND) Filter - Extensively utilized for a variety of applications in optical microscopy, neutral density filters are neutral gray in color (resembling smoked glass) and are designed to reduce transmitted light intensity evenly across either a small number of wavelengths or the entire wavelength spectrum without altering the spectral profile of illumination. 8. Pinhole - placed near the light source and detector, enabling the microscope to produce thin optical sections of focal planes in the specimen.

A scheme of SCM Numerical Aperture (NA) of an objective and the effect on optical resolution and light collection

Two styles of SCM setup

Zeiss LSM 510

Olympus FV 1000

Many books and readings available And Google: scanning confocal + your topic

Major applications of SCM 1. Single-molecule imaging and spectroscopy (high throughput), particularly in solutions, where NSOM is hardly to be applied, and no spatial resolution required. 2. Single-molecule rotation and diffusion. 3. Protein folding and dynamic conformations. 4. In situ single-cell imaging of virus attack. 5. Nanocrystal optoelectronics. 6. Single-molecule Raman spectrometry.

SCM allows for detecting at different depths into sample Protection from oxygen and moisture is often required.

Lectures on SCM 1. Single-molecule imaging and spectroscopy, particularly in solutions, where NSOM is hardly to be applied, and no spatial resolution required. 2. Single-molecule rotation and diffusion. 3. Protein folding and dynamic conformations. 4. Cellular attack by virus. 5. Nanocrystal optoelectronics. 6. Single-molecule Raman spectrometry.

Advantages of SCM over NSOM High spatial resolution of NSOM --- critical for studying nanostructured materials, but not necessary for singlemolecule imaging, because the molecules can be dispersed such that they are far enough apart (> 300 nm) that diffraction limited optics can resolve individual ones. Historically, detection of the fluorescence from single molecules on a surface at room temperature was originally achieved with NSOM. Soon after this discovery, confocal microscopy had emerged as a more popular technique to detect single molecules. Although confocal microscopy is not capable of sub-wavelength resolution imaging, it has a number of advantages over NSOM. One representative person is Morner, slide. 1. Very high optical excitation powers are possible, whereas with NSOM, the upper limit of the excitation power is severely limited. The higher fluorescence intensities that accompany higher excitation powers raises the S/N and reduces the time integration needed for any given experiment. This is important for faster imaging rates and for looking at fluorescence signals which fluctuate on short (millisecond) time scales. 2. SCM is relatively easy to set up in comparison to NSOM, since no feedback system to be maintained. Setting up and optimizing shear force distance regulation is the most time consuming step in NSOM. 3. For NSOM, the position of the APD needs to be adjusted each time a new tip is used, and should also be optimized, or at least checked for optimization, each time a new region of the sample is imaged (i.e. when the course position of the sample is adjusted). This is because the tip, each time replaced or moved slightly, is not aligned confocal with the detector. In contrast to this, the focal spot of SCM objective does not change. Multiple samples can be imaged over days, and probably weeks, without any drifts substantial enough to require adjusting the position of the APD --- high throughput screening. 4. The excitation power of SCM is more easily measured. SCM is capable of power dependence studies, which simply cannot be done with NSOM because the high power regime is inaccessible. For NSOM, the differences in the throughput of each tip and differences in the efficiency of coupling junctions (typically, one which couples light from a free space laser beam to the single mode fiber, and another fiber-to-fiber splice to couple into the NSOM probe) prevent simply measuring the power of the input beam.