Significance of Glazing Thermal Conductivity for MAC Indirect Emissions and EV Battery Performance



Similar documents
TEACHING SUSTAINABLE ENERGY SYSTEMS A CASE STUDY

Sino-Italian Environment & Energy Building S I E E B

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.

Computational Fluid Dynamic Investigation of Liquid Rack Cooling in Data Centres

Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro

Sea Water Heat Pump Project

A Roof Integrated Solar Heating System Without Storage

Solar Aquaponics Designing a 100% Solar Aquaponics Greenhouse

Selecting Energy Efficient New Windows in Arizona

Selecting Energy Efficient New Windows in Florida

Selecting Energy Efficient New Windows in Texas

SELECTIVE GLAZING FOR SUN CONTROL

The heat is on: Don t leave your chocolate candy, kids or pets in a parked car

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

CFD Analysis of Application of Phase Change Material in Automotive Climate Control Systems

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design

Energy Efficiency in Buildings

Selecting Energy Efficient Replacement Windows in Nevada

Selecting Energy Efficient New Windows in Georgia

HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

Subtropical Cities September Design for Energy Efficiency in Commercial Buildings in Queensland

Air Conditioning System

Challenges for air conditioning and heating solutions in electrobuses

Professional Report. Map section. Location of the system. Valkkinen Longitude: Latitude: Elevation: 89 m

AT&T Global Network Client for Windows Product Support Matrix January 29, 2015

Solar Energy Utilisation in Buildings

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS

Exemplary Retrofitting of an Old School in Stuttgart - EROS -

Pilkington Activ. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories.

CHP Plant based on a Hybrid Biomass and Solar System of the Next Generation EU project No. ENER/FP7/249800/"SUNSTORE 4" Dipl.-Ing. Alfred Hammerschmid

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

Greenhouse Glazing Effects on Heat Transfer for Winter Heating and Summer Cooling

THERMAL LOSSES Thermal Losses Calculations

Pilkington Activ self-cleaning glass. The clear choice for your conservatory.

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems

Battery Thermal Management System Design Modeling

2.1 The performance of bus air conditioning system is evaluated in the following operating conditions

Case Study 13 Schools of Architecture and Design, Wellington tertiary education institute, New Zealand

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

ETA-FEP 001. Fleet Test And Evaluation Procedure

BPC Green Builders. Green building for new and existing homes. Health Comfort Energy

Comments on How Exterior Paints and Interior Paints Can Play Roles in Conserving Energy. For Tech Traders Inc. By H. F. Poppendiek

Modelling of fire spread in car parks

Awnings in Residential Buildings The Impact on Energy Use and Peak Demand in Twelve U.S. Cities

Passive Solar Design and Concepts

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

CO2 Emissions. Indirect CO 2. Emissions Electricity and Heat Production 25 % Direct Emissions AFOLU 24 % Energy 1,4% Buildings 6,4 % Industry 11 %

Comparison between Decentralised and Centralised Air Conditioning Systems

Self-Cleaning. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories.

EN Insulating glass units, intended to be used in buildings and construction works

Variable Capacity Compressors, a new dimension for refrigeration engineers to explore

Energy Efficiency: Integrated Design and HVAC Systems HEALTHCARE - TOP 5 GREEN BUILDING STRATEGIES

The Watergy greenhouse: Improved productivity and water use efficiency using a closed greenhouse

Solar Absorption Cooling / Heating System for the Intelligent Workplace

Condensing Boiler Efficiency

Direct Fresh Air Free Cooling of Data Centres

Opening the Bonnet. Prof Darren Woolf WYSINWYG 1

Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial

Benefits of. Air Flow Management. Data Center

BEST 3, Atlanta, April 2012 Grahame E. Maisey, P.E.

THE ROOFPOINT ENERGY AND CARBON CALCULATOR A NEW MODELING TOOL FOR ROOFING PROFESSIONALS

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

Introduction to DEAP for Professionals DWELLING ENERGY ASSESSMENT PROCEDURE (DEAP)

AIR CONDITIONERS ROOF TOP & UNDERBUNK INSPIRED BY COMFORT NEW RELEASE DOMETIC FRESHJET

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

ResearcH JournaL 2009 / VOL

Ecofys VII U-Values for Better Energy Performance of Buildings

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

Auburn University s Solar Photovoltaic Array Tilt Angle and Tracking Performance Experiment

Residential HVAC System Sizing

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

3-D Modeller Rendered Visualisations

Module 1 : Conduction. Lecture 5 : 1D conduction example problems. 2D conduction

Professional Report. US Solar Network Evanston residential DHW. 1 Gobi Helio-Pak 2-4 persons. Map section. Location of the system

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

Efficient use of energy simulation in the early design phase

A. Hunter Fanney Kenneth R. Henderson Eric R. Weise

HDA

PERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING

8ah: 2xBlue-B ST300L 2.919MW SF56.5% 225L/D. 2,391.9 kwh

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Climatography of the United States No

Impact of Vehicle Air- Conditioning on Fuel Economy, Tailpipe Emissions, and Electric Vehicle Range

LOW-E PHOTOVOLTAIC GLASS TECHNICAL GUIDE

Data center upgrade proposal. (phase one)

OPTIMAL POLYGEN COOLING CONCEPT FOR ST. OLAVS HOSPITAL IN TRONDHEIM, NORWAY

Climatography of the United States No

Automatic air conditioning system (with the Lexus Display Audio system)

CONDENSATION IN REFRIDGERATED BUILDINGS

Performance Analysis of Solar Air Heater Using CFD

Climatography of the United States No

Transcription:

Significance of Glazing Thermal Conductivity for MAC Indirect Emissions and EV Battery Performance Steve Gasworth and Triloka Tankala SABIC Innovative Plastics sgasworth@exatec.biz steven.gasworth@sabic.com (as presented)

Reduced glazing thermal conductivity reduces steady state MAC indirect emissions Outside air temperature Heat transfer coefficients: h overall h i inside surface outside surface h o T A Thermal conductivity TC d Glazing (area A) T C Cabin air temperature (steady state) Total heat transfer = Conduction + Radiation = h A (T A - T C ) + Radiation where 1/h = 1/h o + d/tc + 1/h i Fix d, Radiation to isolate TC effect Reduced thermal conductivity means reduced Total heat transfer reduced HVAC cooling load reduced MAC indirect emissions Computational Fluid Dynamics case study: Phoenix, mid-day, Apr - Oct, 100 kmph vehicle speed Reduced roof & backlite thermal conductivity from 1 W/m- K (glass) to 0.2 W/m- K (polycarbonate) 5.5% reduction HVAC load (kw) 4.5 gco 2 /mile reduction MAC indirect emissions Reduced thermal conductivity glazing materials like polycarbonate can help reduce MAC indirect emissions 5.5% load reduction achievable

Significance of Glazing Thermal Conductivity for MAC Indirect Emissions and EV Battery Performance Steve Gasworth and Triloka Tankala SABIC Innovative Plastics sgasworth@exatec.biz steven.gasworth@sabic.com (expanded version)

Approach and Scope Isolate glazing thermal conductivity (TC) effect Hot and cold climates Stationary and moving vehicles Thermal steady state CFD (Computational Fluid Dynamics) model of generic car Baseline TC: 1 W/m- K (Glass) all around Reduced TC: 0.2 W/m- K (Polycarbonate) applied to rooflite and backlite Glazing thermal conductivity HVAC Load Glazing inside temperature MAC indirect emissions EV battery performance Secondary radiation Condensation

CFD Model Vehicle/Air speed (0, 100 kmph) Temperature and radiation data, monthly, mid-day (NREL) Phoenix Minneapolis Glazing parameters Area Orientation Solar transmission Thermal transmission Thermal conductivity Thickness (5 mm) Generic car 3D air flow & heat transfer Steady state HVAC load Glazing temperature Cabin parameters Volume Non-glazing areas (doors, etc.) Interior surfaces (IP, seats) HVAC parameters Vent locations Air velocity Air mass flow rate Temperature set point (22 C)

CFD Results - Phoenix - Moving Vehicle HVAC load (kw), Apr - Oct (cooling) Baseline TC 1.193 Reduced TC 1.128 % reduction 5.45 Battery parameters EV range, Apr - Oct % increase 4.4 NREL fuel economy data MAC indirect emissions (gco 2 /mi), Apr - Oct Reduction 4.5 Roof inside temperature ( C) - Jul Baseline TC 37.7 Reduced TC* 33.8 Cabin air 22.0 Ambient 40.6 *Glazing temp. closer to cabin temp. (relevant to secondary radiation)

CFD Results - Minneapolis - Moving Vehicle HVAC load (kw) Jun - Aug (cooling) Oct - Apr (heating) Baseline TC 0.442 1.303 Reduced TC 0.421 1.217 % reduction 4.75 6.60 Battery parameters EV range, Oct - Apr % increase 5.5 NREL fuel economy data MAC indirect emissions (gco 2 /mi), Jun - Aug Reduction 3.9 Roof inside temperature ( C) - Jan Baseline TC -0.8 Reduced TC* 4.9 Cabin air 22.0 Ambient -5.2 *Glazing temp. closer to cabin air temp. (relevant to condensation)

Perspective Reductions in MAC indirect emissions (gco 2 /mile) due to Reduced glazing thermal conductivity, Phoenix, Apr - Oct 4.5 Reduced glazing thermal conductivity, Minneapolis, Jun - Aug 3.9 Weight reduction (glass polycarbonate, roof & backlite, 3960 lbs curb wt.) 4.0 Improved MAC system, large car (CARB Staff Proposal, AB 1493, 6/14/04, p64) 8.1 Thermal conductivity effect on steady state gco 2 /mile is on par with weight & MAC effects Thermal conductivity reduction decreases EV battery discharge rate, increases EV range Thermal conductivity and weight effects are additive Drive cycle should include steady state cabin temperature and air flow over car Thermal conductivity role is reduced for stationary vehicle due to reduced outside air speed Thermal conductivity reduction steady state glazing inside temperature closer to cabin temperature reduced secondary radiation (summer) & tendency for condensation (winter)