Setting for component replacement alert for PRIMEQUEST



Similar documents
Secure Agent Quick Start for Windows

Practice Fusion API Client Installation Guide for Windows

Setting up VMware ESXi for 2X VirtualDesktopServer Manual

How to Connect to Berkeley College Virtual Lab Using Windows

Overview of ServerView Windows Agent This chapter explains overview of ServerView Windows Agent, and system requirements.

Aventail Connect Client with Smart Tunneling

TSM for Windows Installation Instructions: Download the latest TSM Client Using the following link:

Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

OrgPublisher for PeopleSoft HCM. Scheduler

Syslog Monitoring Feature Pack

Technical Bulletin. SQL Express Backup Utility

Sophos Anti-Virus standalone startup guide. For Windows and Mac OS X

Easy Setup Guide for the Sony Network Camera

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

NetIQ Sentinel Quick Start Guide

MAC OS X 10.5 Mail Setup

IBM Sterling Control Center

How schedule AccuTRConsole to run every hour

Windows 7 Hula POS Server Installation Guide

Understanding Task Scheduler FIGURE Task Scheduler. The error reporting screen.

QUANTIFY INSTALLATION GUIDE

FUJITSU Cloud IaaS Trusted Public S5 Connecting to a Virtual Machine (VM)

PaperClip. em4 Cloud Client. Setup Guide

VPS Remote Computing. Connecting to a Windows Server for the first time. 1 Your Server has been installed. 2 Finding the login details for your Server

ReadyNAS Setup Manual

DS License Server. Installation and Configuration Guide. 3DEXPERIENCE R2014x

Virtual Office Remote Installation Guide

Enabling Backups for Windows and MAC OS X

How to install and use the File Sharing Outlook Plugin

DS License Server V6R2013x

StarWind iscsi SAN Software: Using StarWind with VMware ESX Server

DOCUMENTATION MICROSOFT SQL BACKUP & RESTORE OPERATIONS

Integrating with IBM Tivoli TSOM

A-AUTO 50 for Windows Setup Guide

RSA Security Analytics

1 Intel Smart Connect Technology Installation Guide:

Connecting to LRDC Fileserver Remotely Using Windows Vista/7 & SRemote VPN

PACK'N DEPLOY GUIDE. Version 2.58

WNMS Mobile Application

QUICK START. GO-Global Cloud 4.1 SETTING UP A LINUX CLOUD SERVER AND HOST INSTALL THE CLOUD SERVER ON LINUX

AXIS 1440 Print Server For EPSON Printers: Product Update. Important Information for Windows

Windows Live Mail Setup Guide

HELP DOCUMENTATION E-SSOM BACKUP AND RESTORE GUIDE

MANUFACTURER RamSoft Incorporated 243 College St, Suite 100 Toronto, ON M5T 1R5 CANADA

Print Audit 6 - SQL Server 2005 Express Edition

WINDOWS 64-BIT INSTALLATION NOTES ORACLE VIRTUALBOX Micro Planner X-Pert V3.5.1 Digital Download Edition

ThinkServer RD540 and RD640 Operating System Installation Guide

PRIMEQUEST Integration

READYNAS INSTANT STORAGE. Quick Installation Guide

Changing Your Cameleon Server IP

Video Administration Backup and Restore Procedures

Remote Access VPN SSL VPN Access via Internet Explorer

Dial Up Config & Connecting Instructions with Graphics

This tutorial provides detailed instructions to help you download and configure Internet Explorer 6.0 for use with Web Commerce application.

Authorware Install Directions for IE in Windows Vista, Windows 7, and Windows 8

CIMHT_006 How to Configure the Database Logger Proficy HMI/SCADA CIMPLICITY

VMware Horizon FLEX User Guide

SAS 9.3 Foundation for Microsoft Windows

AUTOCUE IVR. User Guide Updated: 06/18/15 Document Number: 36UG

Sophos Anti-Virus for NetApp Storage Systems startup guide

ESET NOD32 Antivirus 4 for Linux Desktop. Quick Start Guide

Sophos UTM. Remote Access via PPTP Configuring Remote Client

HELP DOCUMENTATION E-SSOM BACKUP AND RESTORE GUIDE

Bloomfield Hills Schools VPN and Viewconnect Instructions

ThinkServer RD350 and RD450 Operating System Installation Guide

FTP Server Configuration

Hyperoo 2.0 A (Very) Quick Start

A. BACK UP YOUR CURRENT DATA. QuickBooks Business Accounting Software for Windows Account Conversion Instructions

Interact for Microsoft Office

User Manual. 3CX VOIP client / Soft phone Version 6.0

Configuration Manual. Version October 2012 File Transfer Daemon. Archive Digitization & Exploitation

Apple Mail Setup Guide (POP3)

A L ERT. Quick Start With

How to Use Remote Access Using Internet Explorer

ReadyNAS Duo Setup Manual

AppleShare Client User s Manual

How to connect to VUWiFi

Setting up VMware Server v1 for 2X VirtualDesktopServer Manual

BrightStor ARCserve Backup for Linux

Yale Software Library

Windows Server Update Services 3.0 SP2 Step By Step Guide

Parallels Desktop Enterprise Edition

Managing Linux Servers with System Center 2012 R2

Remote Desktop Services

Using MioNet Senvid Inc. User Manual Version 1.07

Parallels Transporter Agent

? Index. Introduction. 1 of 38 About the QMS Network Print Monitor for Windows NT

Aspera Connect User Guide

USB PORT NETWORK HUB. User Manual DA DA

HP Device Manager 4.6

Dell Statistica Statistica Enterprise Installation Instructions

Configuring IBM Cognos Controller 8 to use Single Sign- On

StarWind iscsi SAN Software: Installing StarWind on Windows Server 2008 R2 Server Core

PRODUCT WHITE PAPER LABEL ARCHIVE. Adding and Configuring Active Directory Users in LABEL ARCHIVE

Setting up Hyper-V for 2X VirtualDesktopServer Manual

Hallpass Instructions for Connecting to Mac with a Mac

Transcription:

Setting for component replacement alert for PRIMEQUEST 2014/06 FUJITSU LIMITED This manual describes the method of preliminary for the and the of the including components which life is determined (such as UPS BBU and RAID BBU) by using a standard function of each OS. RAS Support Service is used to monitor the including components which life is determined for PRIMEQUEST. But when VMware ESXi 5, OracleVM, Oracle Linux, SUSE Linux or Windows Server 2012(include R2) is used, RAS Support Service cannot be used. Therefore, please configure the notification of of the including components which life is determined that uses a standard function of each OS referring to the following example. 1 Setting example in "VMware" Here, it explains the setting example of the notification in VMware. Please set it for VMware on guest OS (Windows Server 2003/2008/2012(include R2) or Red Hat Enterprise Linux). Please refer to the setting example in the following each OS for a detailed setting method. * Notes 1) When you will move guest OS under the control of other physical servers by using VMware VMotion, please set the host name etc. beforehand in the notification message with a physical server as you understand whether the including components which life is determined to be notified is installed on which physical server. - Example of setting message in VMware <HostName> It is 365 days till the operating life of RAID BBU x <HostName>: Host name of physical server in which the components to be notified is installed * Notes 2) As for the message output by this setting, remote notification (REMCS/Mail/Trap) is not done. Please contact Support staff for PRIMEQUEST when you confirm the message output by this setting. 2 Setting example in "OracleVM" Here, it explains the setting example of the notification in OracleVM. Please set it for OracleVM on guest OS (Windows Server 2003/2008/2012(include R2) or Linux). Please refer to the setting example in the following each OS for the details. * Notes 1) When you will move guest OS under the control of other physical servers, please set the host name etc. beforehand in the notification message with a physical server as you understand whether the including components which life is determined to be notified is installed on which physical server. - Example of setting message in OracleVM <HostName> It is 365 days till the operating life of RAID BBU x <HostName>: Host name of physical server in which the components to be notified is installed * Notes 2) - 1 -

As for the message output by this setting, remote notification (REMCS/Mail/Trap) is not done. Please contact Support staff for PRIMEQUEST when you confirm the message output by this setting. 3 Setting example in "Oracle Linux" Here, it explains the setting example of the notification in Oracle Linux 6.4. Please set it for Oracle Linux referring to the following "8 Setting example when guest OS is "Red Hat Enterprise Linux"" for the details. 4 Setting example in "SUSE Linux" Here, it explains the setting example of the notification in SUSE Linux 11. Please set it for SUSE Linux referring to the following "8 Setting example when guest OS is "Red Hat Enterprise Linux"" after executing the following "Preparation before the setting". [Preparation before the setting] 1. Start the terminal with root privileges. 2. Confirm the "at daemon" is operating by the following commands. # service atd status - The following messages are displayed when operating. Checking for at daemon: running Start the "at daemon" of the following commands when not operating. # service atd start 3. Set for the "at daemon" to start by the automatic operation in the following commands. # chkconfig atd on 5 Setting example in "Windows Server 2012(include R2)" Here, it explains the setting example of the notification in Windows Server 2012(include R2). Please set it for Windows Server 2012(include R2) referring to the following "6 Setting example when guest OS is " Windows Server 2008/2012(include R2)"". 6 Setting example when guest OS is "Windows Server 2008/2012(include R2)" Here, it explains the setting example of the notification in the following way in Windows Server 2008/2012(include R2). - Record in event log - Notification of pop up message The following functions of Windows are used. - Task Scheduler - EVENTCREATE command - MSG command [Setting example] 1. Windows is logged on with Administrator. 2. Click the [Start] button, click [Control Panel]-[System and Maintenance]-[Administrative Tools], and double-click [Task Scheduler] to run Task Scheduler. 3. Select [Task Scheduler Library], and click [Create Task] from the menu displayed by right-clicking. - 2 -

4. Select [General] tab. Input an arbitrary name to the task name, and select [Run whether user is logged on or not] and [Do not store password] in task security options. 5. Select [Triggers] tab, and click [New...] button. 6. Select [One ] radio button, and choose a date and to trigger the task. * Please refer to the notification schedule of Table-1 for a specified part of the notified. Please specify zone that the server is operating at the to trigger the task. Moreover, check [Enabled]. Click [OK] when the setting is completed. 7. Select [Actions] tab, and click [New...] button. Here, what action you cause at the scheduled is specified. [Setting example when log is recorded in event log] Please set it like the following examples when you record the log in the event log (application). Action : Start a program Program/script : EVENTCREATE Add arguments : 1) When you notify the level of the event as an Error /SO F5EP50 /ID 123 /L APPLICATION /T ERROR /D "<message>" /SO F5EP50 /ID 123 /L APPLICATION /T ERROR /D "<message>" - of RAID BBU 2) When you notify the level of the event for preliminary as Warning and for as Error. /SO F5EP50 /ID 123 /L APPLICATION /T WARNING /D "<message>" /SO F5EP50 /ID 123 /L APPLICATION /T WARNING /D "<message>" - of RAID BBU Click [OK] when the setting is completed. [Setting example when pop up message is notified] Please set it as follows when you display the pop up message on the screen of Administrator. Action : Start a program Program/script : MSG Add arguments : Administrator /TIME:0 "<message>" - 3 -

Click [OK] when the setting is completed. 8. Select [Conditions] tab. If [Stop if the computer ceases to be idle condition] and [Restart if idle state resumes] are selected, remove these checks. 9. Select [Settings] tab. Select [Allow task to be run on demand] and [Run task as soon as possible after a scheduled start is missed]. 10. Click [OK] when the setting is completed. 11. Confirms the operation of the task. Select the task that you want to run. Right-click the task and click [Run]. Please confirm whether the task of setting it is correctly executed. The log recorded in the event log (application) is actually shown in Table-2. [Table-1] Notification schedule and message in Windows Server including components notification which life type notification schedule notification message is determined UPS BBU preliminary in 1 year and 9 months It is 90 days till the operating life of UPS BBU. (635 days) UPS BBU exceeded the operating life. in 2 years (730 days) RAID BBU preliminary It is 365 days till the operating life of RAID in 2 years (730days) BBU x. RAID BBU x exceeded the operating life. in 3 years (1095 days) [Table-2] Log recorded in event log (Application) in Windows Server source event ID level message Note F5EP50 Error It is 90 days till the operating life of UPS preliminary 123 (or Warning) BBU. of UPS BBU 124 Error UPS BBU exceeded the operating life. of UPS BBU 123 Error It is 365 days till the operating life of preliminary (or Warning) RAID BBU x. of RAID BBU 124 Error RAID BBU x exceeded the operating life. of RAID BBU 7 Setting example when guest OS is "Windows Server 2003/2003 R2" Here, it explains the setting example of the notification in the following way in Windows Server 2003/2003 R2. - Record in event log - Notification of pop up message - 4 -

The following functions of Windows are used. - Task Scheduler - EVENTCREATE command - MSG command [Setting example] 1. Windows is logged on with Administrator. 2. Click on the [Start] Button, Select [Programs] (or [All Programs]) - [Accessories] - [System Tools] - [Scheduled Tasks]. 3. In the Scheduled Tasks window, click [File] - [New] - [Scheduled Task]. A New Task icon appears. The title is in Edit mode so that you can immediately enter a name for the new task. 4. Double-click new task to open the task's Properties dialog box. 5. Select [Task] tab. Here, what action you cause at the scheduled is specified. [Setting example when log is recorded in event log] Please set it like the following examples when you record the log in the event log (application). Run: 1) When you notify the level of the event as an Error EVENTCREATE /SO F5EP50 /ID 123 /L APPLICATION /T ERROR /D "<message>" EVENTCREATE EVENTCREATE /SO F5EP50 /ID 123 /L APPLICATION /T ERROR /D "<message>" - of RAID BBU EVENTCREATE 2) When you notify the level of the event for preliminary as Warning and for as Error. EVENTCREATE /SO F5EP50 /ID 123 /L APPLICATION /T WARNING /D "<message>" EVENTCREATE EVENTCREATE /SO F5EP50 /ID 123 /L APPLICATION /T WARNING /D "<message>" - of RAID BBU EVENTCREATE Confirm the Enabled (scheduled task runs at specified ) check box is selected. [Setting example when pop up message is notified] Please set it as follows when you display the pop up message on the screen of Administrator. Run: MSG Administrator /TIME:0 "<message>" - 5 -

Confirm the [Enabled (scheduled task runs at specified )] check box is selected. 6. Select [Schedule] tab. Select [One ], and choose a date and to trigger the task. * Please refer to the notification schedule of Table-1 for a specified part of the notified. Please specify zone that the server is operating at the start. 7. Select [Settings] tab. If [Don t start the task if the computer is running on batteries] and [Don t start the task if the computer is running on batteries] are selected, remove these checks. 8. Click [OK] when the setting is completed. If the setting of account information window is shown, enter the password for Administrator and click [OK]. 9. Confirms the operation of the task. Select the task that you want to run. Right-click the task and click [Run]. Please confirm whether the task of setting it is correctly executed. The log recorded in the event log (application) is actually shown in Table-2. *** Reference *** - EVENTCREATE command The EVENTCREATE is a command of the Windows standard to write an arbitrary log in OS event log. The meaning of each option is as follows. /SO : The source to use it for the event is specified. /ID : Event ID is specified. Please specify an arbitrary value within the range of 1-1000. /L : The kind of the event log is specified. (ex. APPLICATION, SYSTEM) /T : The type (level) of the event log is specified. (ex. ERROR, WARNING, INFORMATION) /D : The explanation written in the event log is specified. Help can be referred to by inputting from the command prompt as "EVENTCREATE /?" for detailed use. - MSG command The MSG is a command of the Windows standard that transmits the pop up message to the random user. The 1st parameter: The user in the destination is specified. It is notified by all users who are logging it on when "*" is specified. The 2nd parameter: /TIME:0 specifies that pop up is displayed indefinitely. The 3rd parameter: The displayed message is specified. Help can be referred to by inputting from the command prompt as "MSG" for detailed use. 8 Setting example when guest OS is "Red Hat Enterprise Linux" Here, it explains the setting example of the notification in the following way in Red Hat Enterprise Linux. - Record of log in syslog (/var/log/messages) The following functions of Linux are used. - at command - logger command - syslog (/var/log/messages) [Setting example] 1. Start the terminal with root privileges. 2. Time and the content where the log is recorded with "at" are set. Please execute the command like the - 6 -

following example. [Execution example] # at now + 730 days at> logger -i -p user.alert -t RASStatusCheck <message> at> <EOT> <- Please push [Ctrl]+[d] In the above example the <message> is recorded in syslog (/var/log/messages) in two years. The explanation of "at" can be referred to by the "man 1 at" command for a detailed setting method of "at". * Please refer to the notification schedule of Table-3 for a specified part of the notified. * Please refer to the notification message of Table-3 for <message> part. [Table-3] Notification schedule and message in Red Hat Enterprise Linux including components notification which life type notification schedule notification message is determined UPS BBU preliminary in 1 year and 9 months (635 days) It is 90 days till the operating life of UPS BBU. UPS BBU exceeded the operating life. in 2 years (730 days) RAID BBU preliminary It is 365 days till the operating life of RAID in 2 years (730days) BBU 1. RAID BBU 1 exceeded the operating life. in 3 years (1095 days) [Table-4] Log recorded in syslog(/var/log/messages) in Red Hat Enterprise Linux Facility priority message note User alert RASStatusCheck[%d]:It is 90 days till the operating life of UPS BBU. preliminary of UPS BBU RASStatusCheck[%d]:UPS BBU exceeded the operating life. of UPS BBU RASStatusCheck[%d]:It is 365 days till the operating life of RAID BBU x. preliminary of RAID BBU RASStatusCheck[%d]:RAID BBU x exceeded the of RAID operating life. BBU * [%d] : Process ID of execution command (logger). Microsoft, Windows, and Windows Server are registered trademarks or trademarks of Microsoft Corporation in the United States and other countries. All other product names are registered trademarks or trademarks of their respective manufacturers. All other products are copyrighted works of their respective manufacturers. Copyright FUJITSU LIMITED 2014-7 -