R7426B,C TEMPERATURE CONTROLLER WITH REAL-TIME CLOCK. MicroniK 200 FEATURES. Order Numbers SPECIFICATION DATA GENERAL



Similar documents
Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007

HERZ-Thermal Actuators

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

TC02 Curtain heater controller

Model: DC-A2IO Advanced HVAC Controller

DCS Input/Output Relay Card Series

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

Automation System TROVIS 5100 Ventilation Controller TROVIS 5177

FX07 Field Controller

Controls for fan coil units and cassettes

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Inwall Room Temperature Unit

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

T7560A,B,C Digital Wall Module

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

CR24-.. Single room controllers

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

ABB i-bus KNX Fan Coil Controller FC/S 1.1

WHITE-RODGERS COMFORT-SET 90 SERIES

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

HVAC Processes. Lecture 7

RZAHUC program version 1.1 Regulation for Reznor Air Handling Units

Heating Controller. Building Technologies HVAC Products

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

CONTROL STRATEGIES FOR HVAC SYSTEMS

IntesisBox KNX LG Air Conditioning

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

COMPTROL 5000 INDEX 52. Issue 5.99 AIR CONDITIONING MICROPROCESSOR OPERATING INSTRUCTIONS. STULZ GmbH, Hamburg

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Duct Humidity Transmitter

RESOL DELTA Sol. universal temperature differential. regulator for solar- and heating systems Mounting instructions. page 1/11

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

T5000 T000 LCD Digital Fan Coil Thermostat

Variable Air Volume - VAV

OPERATING INSTRUCTIONS (TRANSLATION OF THE ORIGINAL) SUPPLEMENTARY OPERATING INSTRUCTIONS FOR YOUR AIR CURTAIN SYSTEM. Serial number: Year: --- Page 1

J TB/TW Temperature limiter, temperature monitor


sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

ECL Comfort 110 Application 130. Weather compensated flow temperature control of heating and boiler systems. Instructions

TR21, TR22, TR23, and TR24 Wall Modules

Workshop 7 PC Software - Tracker

Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E.

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Dyeing Programmer DP - 01

ABNORMAL OPERATION Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target

HCE80/HCC80/HCE80R/HCC80R

EBS852 (Contrac) Power Electronic Unit

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

KNX Panasonic Air Conditioners

Rev 0 25-AUG ipro HVAC and Lighting Installation and Operation Manual

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

T-100-R Installation Guide

DDC Controls Package Manual

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Technical Support Bulletin Nr. 20 Special AC Functions

Smile. The All-In-One Heating Controller

Thermostat with display

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

FX07 Field Controller

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

EC3-D72 Superheat & Digital Scroll Controller Technical Data

PB-600 series. 600W Single Output Battery Charger SPECIFICATION MODEL PB PB PB V 28.8V 57.6V 13.8V

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Configuring Alarms & Relays in the Enhanced Transformer Advantage

NX Series Inverters. HVAC Pocket Programming Guide

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

Telefon (+45) Telefax (+45) Installation and operating manual

RRV934. Multi-controller. Synco living

Communicating Thermostats. Add More Flexibility to Building Automation with New. Communicating Thermostats

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

AIR CONDITIONER WALL CONTROLLER

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

User manual Rev 1.3 Contents

T775U Series 2000 Electronic Stand-Alone Controller

MP-4000 Alarm List (Software version or later)

+ A B V B NO NC V COM PV PV

english OEM Solutions Systems for energy-efficient ventilation control

S & P COIL PRODUCTS LTD SPC HOUSE, EVINGTON VALLEY ROAD, LEICESTER. LE5 5LU. Electrical layouts for EC Motors in Fan Convector units

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

Failure code manual. content

Transcription:

MicriK 2 Fig. 1. Temperature ctroller R7426B,C TEMPERATURE CONTROLLER WITH REAL-TIME CLOCK SPECIFICATION DATA GENERAL The R7426B,C temperature ctrollers cover all space and/or discharge air temperature applicatis within the specified ctrol range of...5 C (LOw range) requiring sequence operati of heating, mixed air damper or energy recovery system and cooling with optial outside air temperature compensati reset of the main setpoint. The ctrollers can be cfigured to perform space or discharge air or spacedischarge air temperature cascade ctrol with limit ctrol. For special higher temperature ctrol applicatis, the ctrol range...13 C (HI range) can be selected. FEATURES Weekly time schedule with up to six switching points per day Automatic daylight saving time change Four different operating modes: Comfort, Standby, Night, and OFF Yearly holiday programming in advance Three types of holiday schedules Self-adaptive optimum start program for room ctrol system Night cycle program Order Numbers Fig. 2. LC Display Order-No. R7426B212 R7426C21 Ctroller Descripti Temperature ctroller with integrated real time clock (RTC), Plant/System ON/OFF output, and three 3-positi floating outputs. The ctroller ers the choice of selectable different output sequence operatis and output signals suitable to drive solid-state relays or step relays. Temperature ctroller with integrated real time clock (RTC), Plant/System ON/OFF output, and three analog outputs. The ctroller ers selecti of different output sequence operatis. ENB-31GE51 R14

TECHNICAL DATA General Electric 8-bit microctroller, 1-bit A/D cverter, EEPROM, and LC display Power supply 24 Vac +1...-15%, 5/6 Hz Power csumpti 3 VA + Actuator power requirements Ctrol range...5 C Battery Type CR232 (life time 8 years) Temperature T1 Main temperature sensor Inputs T2 Cascade temperature sensor T3 Compensati temperature sensor Sensor type 1) Automatic identificati of sensor type Temperature range Characteristics 2) accuracy.5 K excluding sensor Pt 1-3...+13 C 1 τ at C BALCO 5-3...+13 C 5 τ at 23.3 C NTC 2kτ -3...+85 C / -3...+13 C 1) 2 kτ at 25 C CPA/SPA-Input 1) CPA/SPA range Sensor & CPA/SPA types CPATYP CPA: 5 K internal CPATYP 1 (953...153 τ) CPA: 5 K T7412B116 (Pt 1) CPATYP 2 (...1 kτ) CPA: 5 K T7412B157 (Pt 1) T7412C13 (Pt 1) T7412B18 (NTC 2kτ) T7412C16 (NTC 2kτ) CPATYP 3 (1...2 kτ) SPA: 15...3 C T7412B124 (BALCO 5) T7412B14 (Pt 1) CPATYP 4 (...1 kτ) CPA: 5 K HCW 23 (setpoint wheel printed with +/- 5 K) CPATYP 5 (...1 kτ) SPA: 15...3 C 43193982-1 CPATYP 6 (...1 kτ) SPA:...5 C or...13 C 43193982-1 Analog input Humidity deviati (X wrh) -5...+5 Vdc, 2 mv / %rh Digital inputs Mode Potential free ctact Occupancy Freeze protecti input unoccupied occupied freeze protecti operati normal operati Outputs ON/OFF output OFF / ON TRIAC outputs Floating 1) 2, 3, 4, 6 or 15-stage 1) ON (24 Vac) / OFF ( Vac) Pulse-width modulati 1)...1% based run time Analog outputs ctroller R7426C Ctrol range 1) /2...1 Vdc (...1%) full range...12 Vdc Ambient limits Operating temperature...5 C (...122 F) Transport and storage temperature -35...+7 C (-31...+158 F) Relative humidity 5...95%rh n-cdensing open > 4 kτ closed < 1 τ open > 4 kτ closed < 1 τ max. load 45 ma at 24 Vac per output max. load 1.2 ma at 12 Vdc Safety Protecti class II as per EN673-1 Protecti standard IP3 or IP4 (frt panel mounting) as per EN6529 Housing Dimensis (H x W x D) 15 x 152 x 37 mm Weight 25 g Mounting Frt door, back panel, wall, or rail Cnectis Cnecti terminal terminals max. 1 x 1.5 mm 2 1) Selectable 2) same sensor type must be used for T1, T2, and T3 ENB-31GE51 R14 2

CONTROL AND CONFIGURATION PARAMETER Ctrol Parameter No. Name Parameter Descripti Setting Low High Default Resoluti P.1 W1 Main setpoint for input T1 5 21.5 C P.2 Wlim Limit setpoint (low or high) for input T2 5 5 16 1 C P.3 Wcomp Compensati changeover point for input T3-5 4 2 1 C P.4 Wi Winter compensati authority -35 +35 2 % P.5 Su Summer compensati authority -1 +1 1 % P.6 Wcas Submaster or cascade setpoint OFF, 5 2.5 C P.7 Rcas Cascade reset span adjustment 4 1.5 K P.8 Xp1 Throttling range (main ctrol loop) T1.5 4 2.5 K P.9 Xp2 Throttling range (cascade ctrol loop) T2.5 4 1.5 K P.1 throttling range for sequence ctrol OFF, 1 4 3.5 K P.11 throttling range for sequence ctrol 1 4 6.5 K P.12 tr1 1) Reset time (main ctrol loop) T1 OFF, 2 s 2min OFF 1/.5 sec/min P.13 tr2 1) Reset time (cascade ctrol loop) T2 OFF, 2 s 2min OFF 1/.5 sec/min P.14 MINPOS Minimal pos. for air damper actuators 5 2 1 % P.15 Ystart Start point for mid range shift of output -2 +2.5 K P.16 SOFFS Offset of main setpoint in Standby mode 1 2.1 K P.17 T1Cal Calibrati of temperature sensor T1-2 +2.1 K P.18 T2Cal Calibrati of temperature sensor T2-2 +2.1 K P.19 T3Cal Calibrati of temperature sensor T3-2 +2.1 K P.2 RetOffs Return air set to simulate exhaust air cd. OFF, 5 OFF.1 K P.21 Runtime Actuator run time for output 6 18 6 1 sec P.22 Runtime Actuator run time for output 6 18 6 1 sec P.23 Runtime Actuator run time for output 6 18 6 1 sec P.24 NightLow Night low limit against temperature extremes OFF, 8 19 OFF 1 C P.25 NightHigh Night high limit against temperature extremes OFF, 21 4 OFF 1 C P.26 NOFFS Offset of main setpoint in Night mode 3 5.1 K Cfig. Parameter No. Name Unit Values Default Unit C.1 DIR/REV Dir C.2 DIR/REV Dir, Rev (R7426C, ly) Dir C.3 DIR/REV Dir C.4 Ctrltyp 2) Lo =...5 C (factory preset), Hi1 =...13 C, Hi2 =...13 C C.5 CPATYP = internal (default), 1 = 5 K (953...153 τ), 2 = 5 K ( τ...1kτ), 3 = 15 3 C (1...2 kτ), 4 = 5 K (...1 kτ), 5 = 15 3 C (...1 kτ), 6 =...5 C or...13 C (...1 kτ) C.6 YRange = 2 1 Vdc, 1 = 1 Vdc (R7426C, ly) 1 C.8 Mode 4 = floating, 1= 2 stage ON/OFF, 2= 3 stage ON/OFF, 3 = pwm, 4 = uncfig. C.9 Mode (safe state is cfigured prior to ctroller's start-up) (R7426B, ly) 4 C.1 Mode 4 : = D, = C, = H 1: /2/1 = H or C C.11 YMode 2: /1 = H, = C 3: /1 = C, = H 4: = 2Pos D, = C, = H 5: /1 = 15H, = C C.12 T2ext = T2 installed 1 = T1 signal used for T2 C.13 LimTyp = Low limit 1 = High limit C.14 Senstyp = Auto detecti 1 = NTC sensor type C.15 CTRF Output used for: = mixed air damper 1= energy recovery C.16 AddHour Adjusts the mth for winter/summer time change: (disabled) = Min. 12 = Max. 3 mth C.17 SubHour Adjusts the mth for summer/winter time change: (disabled) = Min. 12 = Max. 1 mth 3 ENB-31GE51 R14

1) 2) 3) Cfig. Parameter No. Name Values Default Unit C.18 PSTG_H 3) Prestart gradient for heating: (disabled) = Min. 2 = Max. K/min C.19 PSTG_C 3) Prestart gradient for cooling: (disabled) = Min. 2 = Max K/min C.2 tvd Use damper before comfort time: (normal ctrol) = Min. 9 = Max. 15 min C.21 Adapt Optimum Start Self Adapti speed: = Min. 1 = Max. 5 % C.22 Adr 2) Serial communicati address: = Min. 255 = Max. 254 C.23 DefProg = No Default programming 1 = Initiates Default programming for tr > 2 min resoluti =.5 min, for tr < 2 min resoluti = 1 sec actual value will not be changed during reset to default parameter can be overwritten by ctroller for self-adapti purposes, resoluti =.1 K/min FUNCTIONS Real-Time Clock The time clock performs automatic change of the ctroller mode to OFF, Night, Standby, or Comfort in accordance with the programmed time schedule. In Standby or Night mode, the SOFFS or NOFFS is added (cooling) to and subtracted (heating) from the calculated ctrol point. Schedules for e week and up to six switching points per day can be programmed in advance and repeated week after week. In additi, three different holiday schedule types H1, H2 and H3 can be programmed. One of these holiday types can be assigned to each holiday date of the year (1.1.... 31.12.). Holiday type H1 and H2 is valid ly for this specific day and is reset to normal time schedule at midnight of that day. H3 is valid for every year and repeated year after year for fixed holiday dates. H1 can be programmed to be in OFF mode the whole day and H2 to be ON for a short period of time the last day of a lger holiday period to preheat or precool the space in advance before the first occupied day. Optimum Start Program The optimum start program s objective is to minimize total energy csumpti by calculating in room ctrol applicatis the start time for heating and cooling mode which will bring its respective space temperature to the boundary of the comfort ze at the time of occupancy start. The program will start the ventilati system at the calculated start time with forced return air recirculati mixed air damper positi or full energy recovery valve positi to minimize energy csumpti during the start-up period. At a programmable time before occupancy start, the ctroller will switch the output signal to normal and will supply fresh air to the space in mixed air applicatis. The optimum start program uses historical data for self-adaptive adjustment. Night Cycle Program The night cycle program ers not ly energy cservati, but also the ability to assign OFF mode night low or high limits with 1 K hysteresis for the protecti of a space and its ctents against temperature extremes. It automatically cycles between the user selected upper and lower limits and turns full heating or cooling whenever the limits are reached. APPLICATION The R7426B,C ctrollers can be used for sequence ctrol applicatis of heating, mixed air damper or energy recovery system, and cooling. NOTE: All diagrams show proportial ctrol acti, ly. If P+I ctrol is in operati, the slopes for heating and cooling are not defined. Temperature Sequence Ctrol with, Mixed Air Dampers, and This applicati will be active with the R7426B,C ctrollers when T2 is not cnected. It can be used for sequence ctrol of a heating valve, a mixed air damper, and a cooling valve. The characteristic of each output the R7426C ctroller can be selected via the ctrol parameters DIR/REVx (x =,, or ). The diagram shows Dir characteristic for all outputs. Within the range Xp1, the damper signal is ctrolled as shown in the diagram below. If no cooling actuator is available, the ctrol parameter can be set to OFF and the damper output is maintained at 1% above ctrol point (CTRP1). If the damper output should be decreased to MINPOS level above ctrol point (CTRP1) as shown in the diagram, the ctrol parameter has to be adjusted to any value between 1 and 4 K, also if no cooling actuator is available. 1 MINPOS NOTE: 1/4 Xp1 if = Off Damper CTRPH CTRP1 Xp1 CTRPC if = Off Xwh / Xwc / Xwd If the R7426B ctroller with floating output is used for mixed air damper ctrol, you must ensure that the output load of maximum 45 ma is not exceeded. T2 ENB-31GE51 R14 4

1 Temperature Sequence Ctrol with, Energy Recovery System, and For applicatis with energy recovery system (ERS), the cfigurati parameter CTRF has to be set to 1 to perform a reverse acting output. The adjustment MINPOS is inactive in this cfigurati and the ctrol parameter has to be set to OFF if the output should be maintained at % above the ctrol point (CTRP1) for summer operati. Within the range Xp1, the energy recovery system is ctrolled as shown in the diagram below. With the R7426C ctroller, a rotary energy recovery wheel can also be ctrolled instead of a valve if the output signal of...1 Vdc or 2...1 Vdc is suitable to ctrol the rotati speed of this device. ERS 1/4 Xp1 R7426B,C TEMPERATURE CONTROLLER Low limit of CTRP2 is performed if ctrol parameter LimTyp = and high limit of CTRP2 is performed if ctrol parameter LimTyp = 1. Within the range Xp2, the damper signal is ctrolled as shown in the diagram below. If no cooling actuator is available, the ctrol parameter can be set to OFF. If ctrol parameter = OFF, the cooling signal is set to % and the damper output is maintained at 1 % above ctrol point (CTRP2). 1 MINPOS 1/4 Xp2 if = Off Damper CTRPH CTRP2 Xp2 CTRPC if = Off Xwh / Xwc / Xwd T2 = Xwh/Xwc/Xwd CTRPH CTRP1 CTRPC Xp1 T1 Temperature Cascade Ctrol with, Mixed Air Dampers, and This applicati will be active with the R7426B,C ctrollers if temperature sensor T2 is cnected and the ctrol parameter W cas is set to any value other than OFF. It can be used for sequence ctrol of a heating valve, a mixed air damper, and a cooling valve. The ctrollers provide cascade ctrol as shown below: T1 C Xp1/2 Offs Offs Xp1/2 CTRP1 MASTER NOTE: If the R7426B ctroller with floating output is used for mixed air damper ctrol, you must ensure that the output load of maximum 45 ma is not exceeded. Temperature Cascade Ctrol with, Energy Recovery System, and For applicatis with energy recovery system (ERS) the cfigurati parameter CTRF has to be set to 1 to perform a reverse acting output. The adjustment MINPOS is inactive in this cfigurati and the ctrol parameter must be set to OFF if the outputs and should be maintained at % above the ctrol point (CTRP2) for summer operati. Within the range Xp2, the energy recovery system is ctrolled as shown in the diagram below. In the case of the R7426C ctroller, a rotary energy recovery wheel can also be ctrolled instead of a valve if the output signal of...1 Vdc or 2...1 Vdc is suitable for ctrolling the rotati speed of this device. 1 ERS 1/4 Xp2 R cas R cas CTRP2 W lim W cas W lim Offs = X w Master for Comfort Mode SOFFS for Standby Mode NOFFS for Night Mode for LimTyp=1 SUBMASTER for LimTyp= X Master w = Xwh/Xwc/Xwd CTRPH CTRP2 CTRPC Xp2 T2 Ecomizer Modes The ecomizer modes are suitable for installatis where the main temperature sensor (T1) is installed in the exhaust air or in the room with a cstant set between room and exhaust air cditis. The set value is programmable within...5 K with the ctrol parameter RetOffs which will be added to the actual measured room temperature value to simulate exhaust air cditis. 5 ENB-31GE51 R14

The ecomizer mode is disabled if the value of the ctrol parameter RetOffs is programmed to OFF, or if no outdoor air temperature sensor is cnected. By comparing the outside air cditi with the exhaust air cditi, the output for the ctroller operates as follows: Mixed Air Dampers RetOffs OFF; CTRF = AIR CONDITION Outside air temperature > Exhaust air temperature Outside air temperature < Exhaust air temperature MINPOS Included in heating sequence ctrol (direct acting) CONTROLLER FUNCTIONS Outside Air Temperature Compensati Outside air temperature compensati is performed when T3 is cnected. The ctrol parameter W comp defines the compensati changeover point for summer and winter compensati. The degree of summer and winter compensati is defined by ctrol parameters Wi and Su. Winter compensati is performed if temperature T3 < W comp. Summer compensati is performed if temperature T3 > W comp. W1 compensated C W1 Wi Su Positive Negative 1 MINPOS Xp1 T1/T2 Xp2 A fixed hysteresis of 1K is used, to switch between MINPOS and actual signal. Energy Recovery System RetOffs OFF; CTRF = 1 AIR CONDITION CTRPH Outside air temperature > Exhaust air temperature Outside air temperature < Exhaust air temperature 1 Energy Recovery CTRPH T1+RetOffs T OA < T EA T OA > T EA Damper 1K CTRP1 CTRP2 1% CTRPC Xwh / Xwc Energy Recovery System included in heating sequence ctrol. MINPOS is not active. T1+RetOffs T OA < T EA T OA > T EA 1K CTRP1 CTRP2 Xp1 Xp2 CTRPC A fixed hysteresis of 1 K is used to switch between % positi and actual signal. Xwh / Xwc T1/T2 Smoothing Filter for Outside Air Temperature Input A smoothing filter for the outside air temperature input T3 is incorporated to eliminate sudden temperature variatis. This provides more stable operati of the ctrol system. This functi will work ly if the ctroller parameters have never been changed by means of the PC tool. Occupied/Unoccupied Functi (SOFFS) A potential free ctact can be used between terminals 1 and 4 to switch the ctroller between occupied (ctact closed) or unoccupied (ctact open) mode. The input is active during Comfort and Standby mode. In occupied mode, the temperature set point W1 is used for the ctrol point calculati. In unoccupied mode, the SOFFS parameter value is added (cooling) to and subtracted (heating) from the calculated ctrol point for cooling and heating. The diagram below shows the occupied/unoccupied functi for sequence ctrol. Y % 1 Freeze Protecti SOFFS CTRPH W comp unoccupied occupied CTRPC SOFFS If the ctact cnected to the freeze protecti input is open, the heating valve () will be driven into the fully open positi. The final ctrol devices operated by the outputs ( and ) will be driven in the closed positi. T3 T C C ENB-31GE51 R14 6

In the case of ctrollers with RTC, the ON/OFF output will be switched. A closed ctact performs a frost recovery: Cditis of Outdoor Temp. T3 > 6 C or T3 not cnected < 6 C Frost Recovery Main temperature ctrol Setpoint W1 is temporarily raised by Xp1 and linearly decreased to its normal value over approx. 1min. Freeze protecti operati has the highest priority over all other ctrol operatis. Dehumidificati Ctrol by Humidity Deviati Input Dehumidificati ctrol can also be performed using a humidity ctroller. The deviati input signal X w rh received from the humidity ctroller is compared with the cooling deviati signal of the temperature ctrol (X wc). The signal with the highest cooling demand is used to ctrol the cooling output. OUTPUT SEQUENCE OPERATION The ctrollers are supplied from the factory cfigured for sequence operati of heating, mixed air, and cooling ctrol. NOTE: If a ctrol range of...13 F (C.4 = 1) is selected, then ly multi-stage heating (Ymode = 1) is applicable. The output sequence operati can be cfigured for the following ctrol applicatis in accordance with the parameter setting CTRF or YMode: Sequence ctrol for cooling with three outputs (CTRF = and YMode = 1) 1 throttling range OAID Sequence ctrol for heating with three outputs (CTRF = 1 and YMode = 1) 1 OAID throttling range Xw Xw Sequence ctrol with two outputs for heating and e output for cooling (YMode = 2) 1 OAIC Sequence ctrol with e output for heating and two outputs for cooling (YMode = 3) 1 / OAIH OAIC OUTPUT FUNCTIONS The R7426B ctrollers provide a choice of output signals suitable for operating a range of final ctrol devices according to the parameter setting of YMode and YxMode (x = 1, 2, or 3) ctrol parameters. 3-positi Output for Valve or Damper Actuators (floating mode) The ctroller cverts the deviati signal to a proportial output pulse which drives the actuators depending the Runtimex (x =,, or ) parameter value. Parameter setting for / Ctrol Outputs : YMode =, 1, 2 or 3; YxMode (x = 1, 2, or 3) =. close out1 stop An automatic synchrizati functi ensures correct positiing of the actuators. This is performed by running all actuators to the closed positi periodically. The run time for synchrizati is derived by ctrol parameter RuntimeYx (x = 1, 2, or 3) multiplied by 1.25. Synchrizati by the ctroller is initiated: after power up reset (initial start) after 25 ctrol steps as so as ctrol output is below 5 % if plant/system ON/OFF input is switched to OFF out2 open Xw T Xw T // 7 ENB-31GE51 R14

Electric Heat Current Valve (pwm output) The pulse-width modulated output is suitable for driving electric heat current valves and is ctrolled from the heating signal. The interval or total cycle time is set by the ctrol parameter Runtime. The diagram below shows as example, 6% Output Signal with Motor Runtime set to 5 sec: YMode = ; Mode = 3. out1/out2 3 5 7 8 1 sec 2-stage ON/OFF Sequence Ctrol The R7426B ctrollers cvert the output signal into a twostage ON/OFF sequence output signal suitable for operating relays. Two relays can be cnected to provide sequence ctrol of e.g. two electric heater stages. Parameter setting for Output Switching Positi: YMode = ; YxMode (x = 2 or 3) = 1 Step1 Step2 Power out2 out1 25 3 65 7 1 % / 3-stage Binary ON/OFF Sequence Ctrol The R7426B ctrollers cvert the heating signal into a three-stage binary ON/OFF sequence as shown in the following diagram. Parameter setting for Output Switching Positi: YMode = ; Mode = 2 Step1 Step2 Step3 Power out2 out1 2 25 45 5 7 75 1 % 4-stage ON/OFF Electric or For YMode = 2, the output sequence of / is ctrolled from the heating signal and the output is ctrolled from the cooling signal. For YMode = 3, the output sequence of / is ctrolled from the cooling signal and the output is ctrolled from the heating signal. The output of is operated in accordance with Mode. Parameter setting: YMode = 2 or 3, Mode and Mode = 4 Step1 Step2 Step3 Step4 Power out2 out1 out2 out1 2 25 4 45 6 65 8 85 1 % / 6-stage ON/OFF Sequence Ctrol or The output sequence of // is ctrolled from e output signal, Main Temperature Ctrol or Cascade Ctrol. Parameter setting: YMode = 1, Mode, Mode, and Mode = 4 CTRF = (cooling) or 1 (heating) Step1 Step2 Step5 6 signal sequence of // out1/out2 Step6 Power 1 15 25 3 7 75 85 9 1 % // 15-stage Binary ON/OFF Electric and The output sequence of / is ctrolled from the heating signal. The output sequence of is ctrolled from the cooling signal. The output of is operated in accordance with Mode. Parameter setting: YMode=5 Step15 Power Step14 Step1 Step2 4 signal sequence of / out1/out2 4.5 11 89 95.51 % 6.5 13 91 97.5 / ENB-31GE51 R14 8

Two-Positi Damper Ctrol If the value of the ctrol parameter YMode = 4, the damper output signal operates as two-positi ctrol as follows: If the ctroller mode OFF (Comfort- Standby- or Nightmode), the output signal is set to 1%. If the ctroller mode = OFF, the output signal is set to %. The output sequence of / operates as Temperature Sequence Ctrol with and. ON/OFF Output The ON/OFF output is provided to switch fans, pumps, or other MicriK 2 ctroller without RTC. If e of the following cditis occur the ctroller switches the ON/OFF output from OFF to ON after a fixed 3-minute time delay: The ctroller mode OFF (Comfort, Standby, or Night mode). The night cycle program is active. The optimum start program is active. If e of the following cditis occur, the ctroller switches the ON/OFF output from ON to OFF: The ctroller mode = OFF. The freeze protecti input is active. The following functi will be active in flow water temperature applicatis if the cfigurati parameter Ctrltyp = Hi2: The ctroller switches the ON/OFF output from ON to OFF if the outside air temperature is above 8 C and the output signal = % for more than 5 minutes during Comfort, Standby, or Night mode. Analog Outputs R7426C, ly Three output ctrol signals are provided to ctrol valve or damper actuators or E/P transducers for pneumatic actuators. The full output range is...12 Vdc. The ctrol range is comm to all outputs and is software-cfigurable using the ctrol parameter YRange to either 2...1 Vdc or...1 Vdc. Each output can be selected for direct or reverse acting. ADJUSTMENTS Ctrol Point / Setpoint Adjustment (CPATYP) The ctrol or setpoint can be adjusted via the internal or an external potentiometer cnected to the CPA/SPA input. The CPA/SPA type is selected using the ctrol parameter CPATYP (see page 2, Technical Data). Calibrati of Temperature Sensors (T1CAL, T2CAL, and T3CAL) In case of an set as a result of lg wiring lengths, the temperature sensor inputs (T1, T2 and T3) can be adjusted separately by the ctrol parameters T1CAL, T2CAL, and T3CAL. WIRING Wiring run From ctroller to all input and output devices Type of Length max. wires 1. mm 2 1.5 mm 2 local standard 1 m 15 m Offset for temperature sensors due to wire resistance per 1 m distance from sensor to ctroller: Type of wire.5mm 2 (AWG2) 1.mm 2 (AWG17) 1.5mm 2 (AWG15) Temperature set Pt 1 BALCO 5 NTC.18 C (.324 F).9 C (.162 F).6 C (.18 F).3 C (.54 F).15 C (.27 F).1 C (.18 F) negligible 9 ENB-31GE51 R14

CONNECTIONS R7426B R7426C 2mV/%rh 24 V 15 16 17 18 19 2 21 22 23 24 25 26 27 28 open/out 2 close/out 1 open/out 2 close/out1 open/out 2 XWrh close/out1 CPA/SPA T1 T2 T3 B A 1 2 3 4 5 6 7 8 9 1 11 12 13 14 * Occupancy T1 T2 T3 Freeze prot. Serial Interface for Panel Bus 2mV/%rh 24 V 15 16 17 18 19 2 21 22 23 24 25 26 27 28 XWrh /2...1V /2...1V /2...1V CPA/SPA T1 T2 T3 B A 1 2 3 4 5 6 7 8 9 1 11 12 13 14 * Occupancy T1 T2 T3 Freeze prot. Serial Interface for Panel Bus = V = V * R7426B114,C112 R7426B212,C21 ON/OFF On/Off Output 9 1 W 33 Jumper 1) State Descripti W33 2) closed open T3 supplied by this ctroller T3 supplied from another ctroller 1) Default jumper positi = closed 2) Cut (open) jumper W33 ly if the T3 input is fed from another ctroller (parallel cnecti, max. 6 devices). This discnects the T3 input from the internal power supply. CAUTION Outputs are not isolated from power supply Observe correct phasing with ac power supply Fig. 3. Cnectis and Jumper coding ENB-31GE51 R14 1

MOUNTING AND DIMENSIONS 152 43 Heywell All dimensis in mm. 15 SEL SET 121 +/-.3 = = 198 +/-.3 17 +/-.3 = = 3.5 = 87 +/-.2 = 11 +/-.3 13 +/-.3 = approx. 45 x 35 (cut-out for cables) 4.5 (when mounting DIN rail) = 3.5 18 +/-.2 wall mounting frt panel mounting Fig. 4. Mounting and dimensis 11 ENB-31GE51 R14

HONEYWELL Automati and Ctrol Solutis Heywell GmbH Böblinger Straße 17 D-7111 Schönaich Phe: (49) 731 6371 Fax: (49) 731 637493 http://europe.hbc.heywell.com Subject to change without notice. Printed in Germany Manufacturing locati certified to ENB-31GE51 R14