ANOTEC INDUSTRIES LTD



Similar documents
Session Five: Modern XLPE Materials for Extruded Energy Cable Systems

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

The optimum material solution for Low Voltage energy cables

2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G

CABLE 101. The Basics of Wire & Cable. Copyright 2007, Belden Inc.

Type XHHW-2 or RHH/RHW-2/USE-2 GenFree II LSZH XLPO Single Conductor

Polyolefin Heat Shrink Tubing for Tight-Tolerance Medical Applications

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

A quick product finder for commercial applications JUDD WIRE INC. A member of the Sumitomo Electric Industries group of companies

Terminal Cleaning and Protection

KALPANA INDUSTRIES LTD. TECHNICAL DATA SHEET

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION

INTERNATIONAL STANDARD

)454, !,5-).)5- #!",% 3(%!4(3 #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43. )454 Recommendation,

Basic Cable Assemblies DELIVERING QUALITY SINCE 1952.

Piping Systems. From design to your turnkey partner

Automotive Wire and Cable Products

W-2. Stranding Comparison

Chlorinated polyethylene ELASLEN TM. Application for Wire and Cable

Effect of Sterilization Techniques on Polymers

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

Unit 12 Practice Test

C A B L E P R O T E C T I O N

VIPERFLEX ELECTRIC CABLE

Environmental Stress Crack Resistance Of Polyethylene

Wire and Cable Product Guide

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

L O W - S M O K E, Z E R O - H A L O G E N C A B L E S :

100% EMI Emission Containment

North American Stainless

Resistance of Plastics to Gamma Irradiation

Caledonian Submersible Pump Cables for Oil Industry >> IEEE 1018 >> IEEE 1019 >> API RP 11S5

Global cable expertise for rolling stock

Magnesium TM. Soil Anodes. High Potential Magnesium. Production - Quality Control. Laboratory- Testing. Packaging- Availability

DOW ECOLIBRIUM Bio-Based Plasticizers - Greening of PVC with Renewably Sourced Plasticizers

EVA Modification, Wire Coating

Pipe Protection Tape System

Contact Hueson Corporation for additional information or details Sutton Street Northbridge, MA

Elements of Addition Polymerization. Branching and Tacticity. The Effect of Crystallinity on Properties

CATHODIC PROTECTION SYSTEM DESIGN

International Electrotechnical Commission Standards

the quality par excellence Meghna Industries Manufacturer of : All types of fiberglass Cables

Fault location on power cables. Fault location on power cables

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.

MICRO PLASTICS MOLDED NYLON 6/6 FASTENERS MECHANICAL TEST DATA - UNC - UNF SECTION

RE-ENTERABLE SPLICE CLOSURE KITS. (For Air Core None Pressurized Cable)

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

Type FLX Freezer Floor Frost Heave Protection DESIGN GUIDE

Building Cables and Wires

COATING & WRAPPING OF UNDERGROUND PIPING

The surface roughness of the polyurethane lining is 10 times lower than cement-lined pipes.

APPLICATION ORIENTED DESIGN OF CABLES

Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes

Hook-Up and Lead Wire

Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks

B05: Cable protection and sheathing

SECTION GUARDA SECURITY WINDOW SCREENS

SPEC 55. Wire and cable. Applications. SPEC 55PC wire and cable insulation system. Features and benefits. Physical characteristics

Derakane epoxy vinyl ester resins: The Evolution of Corrosion Resistant FRP

SPECIFICATION RW-2510 Document Number RPS

Industrial Cable Solutions for Variable Frequency Drives

CONFLEX ELECTRIC CABLE

Festoon 715 P PUR cable for flexible application in festoon systems

PRODUCT / APPLICATION INFORMATION

PROCESSING OF VARIOUS MATERIALS

Flexible cables for submersible products

Instrumentation Cable Power Cable Assembly Solutions...32

Anodizing Reference Guide

MICROCABLES. A complete vision of your connectivity needs. Catalogue

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

RAIL /// WIRE & CABLE WHERE THE BEST IDEAS IN RAIL BEGIN

Commercial Coaxial Cable

SECTION POLYVINYL CHLORIDE (PVC) PIPE

TABLE OF CONTENT

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

PVC Pipe PVC SCHEDULE 40. Nominal Pipe Size (in.) 1/8. Average I.D. O.D.

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Flygt flexible cables

4. Cryogenic gloves are generally designed to protect the hands from intense cold or heat.

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

Contents. All Rights Reserved

Native InDesign 2890 SaniTite Brochure 1/8" CMYK April 17, 07

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute

MaxCell Technical Manual Design Parameters

UGVCL/SP/591/11KV HT AB CABLE

Environmental Stress Crack Resistance of Polyethylene Pipe Materials

Pipes and Fittings for Gravity Sewer Mains. SewerMAX

HEAT SHRINK RAYCHEM PRODUCT TECHNOLOGY A PROVEN TRACK RECORD OF SOLVING THE WORLD S HARSHEST CHALLENGES

LIFTING WIRE FOR HOT-DIP GALVANIZING BY THOMAS LANGILL, Ph.D.

PAAM COMMERCIAL PRIVATE LIMITED

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

INDEX. Sec. No. Items Page Nos.

Simple, Comprehensive Tubing Solutions. Alpha Wire Company

Transcription:

ANOTEC INDUSTRIES LTD ELECTRICAL CABLES FOR CATHODIC PROTECTION Rev 0.0 06 Dec 2005 This article is intended to familiarize the reader with types of cathodic protection cable commonly used in North America to connect High Silicon Cast Iron Anodes to Direct Current power sources. The reader is cautioned that this presentation is not exhaustive or comprehensive, and that it is intended as an introduction to the subject. Note: dimensions listed are nominal, and have been abbreviated for convenience Copper Conductors CP cable always consists of copper conductor insulated from the surrounding soil or electrolyte. In North America, Anode Lead Cables usually contain one of the following conductor options: TABLE 1: NORTH AMERICAN COPPER CONDUCTORS for CP Cables Size Nominal OD Nominal Area Resistance 25C Nominal Strength AWG Stranding inch mm sqin sqmm ohms/kft ohms/km lb kg 8 7-0.0486 0.15 3.8 0.013 8.37 0.41 1.35 480 220 6 7-0.0612 0.19 4.8 0.206 13.3 0.26 0.85 760 345 4 7-0.0772 0.23 5.8 0.033 21.2 0.16 0.53 1200 545 2 7-0.0974 0.30 7.6 0.052 33.6 0.13 0.42 1900 860 Note: Manufacturers may compress conductors, resulting in a smaller than tabulated Nominal OD. TABLE 2: STANDARDS AND OPTIONS FOR AMERICAN CATHODIC PROTECTION CABLE CONDUCTOR (Details have been omitted for simplicity) CONDUCTOR Standard: Typical Specification: Cautions: Characteristics: COPPER WIRES ASTM B-3 Soft or Annealed STRANDS, ASTM B-8 Concentric Lay Copper conductors shall be Class B stranded, compressed, annealed, uncoated copper in accordance with ASTM B-8 latest edition. Some specifications for conductors may require "flexible" cable with many small strands (i.e. Class C = 19), or with "tinned" wires Common Wire Sizes Area CLASS C CLASS B Note 1. sqmm sqin 19 STRANDS 7 STRANDS 8 8.3 0.013 (for flexibility) (most common) 6 13.3 0.0206 4 21.1 0.033 2 33.7 0.052 NOTE 1: Wire Size: Wire diameters conform to various gauging systems. Typical North American CP cable bulletins refer to cable sizes by "Gauge" without defining the gauging system used, and "Stranding" which references the number of (wire) strands and the inch decimal diameter of the wires. Some refer to the acronym "AWG" which has become widely used to mean "wire size" in the CP trade, but technically, the wire may be manufactured to a different gage system. This difference has virtually no practical significance to CP performance. It is also usual for manufacturers to reference Standards ASTM B-3 (wire) and B-8 (strands). In fact ASTM B-3 references ASTM B258 Specification for AWG Sizes of wires. Table 3 on page 2 compares nominal conductor sizes for Metric American and British Gauges. Electrical Cables for Cathodic Protection.doc Last printed 1/24/2006 11:45 AM Page 1 of 6

TABLE 3 WIRE GAUGE COMPARISON METRIC - AMERICAN - BRITISH RESISTANCE OHMS/KM CABLE DIMENSIONS APPROXIMATE EQUIVALENT AMERICAN WIRE GAUGE METRIC GAUGE mm2 BRITISH STANDARD GAUGE AREA mm2 DIAMETER mm 8.3 2.1 1.6 14 16 6.9 2.5 1.8 2.5 15 5.2 3.3 2.1 12 14 4.3 4.0 2.3 4 13 3.3 5.3 2.6 10 12 2.9 6.0 2.8 6 11 2.1 8.3 3.3 8 10 1.7 10.0 3.6 10 9 1.3 13.3 4.1 6 8 1.1 16.0 4.5 16 7.83 21.1 5.2 4 5.70 25.0 5.6 25 4.52 33.7 6.5 2 3.50 35.0 6.7 35 2.41 42.3 7.3 1 1.35 50.0 8.0 50.33 53.5 8.3 1/0 1/0.26 67.5 9.3 2/0 2/0.25 70.0 9.4 70 3/0.20 85.2 10.4 3/0 4/0.18 95.0 11.0 95 5/0.16 107.2 11.7 4/0 5/0.14 120.0 12.4 120 7/0 Electrical Cables for Cathodic Protection.doc Last printed 1/24/2006 11:45 AM Page 2 of 6

CABLE INSULATIONS In North America, CP cable usually has one of the following insulation / jacket options: A single layer of Polyethylene insulation 0.11" (2.8mm) thick used in the majority of surface groundbeds, and commonly called "HMWPE" (High Molecular Weight Polyethylene) A fluorocarbon polymer insulation 0.02" (0.5mm) protected by a polyethylene jacket.06" (1.5mm) thick, primarily for deep well groundbeds where halogen gases, particularly chlorine, are evolved and concentrated around the anode and cable. These types are commonly called "KYNAR" or "HALAR". CAUTION: Although it may be convenient to use acronyms or trade names such as "HMWPE", "KYNAR" and "HALAR", these terms do not accurately define the technical differentiations found in specifications and contracts. For this reason CP practitioners should be familiar with the Standards and options for Copper Conductors and Insulations, and be aware of the sub classes and "boiler plate" within Standards. Tables 5 (page 5) and 6 (page 6) provide examples of technical differentiation between insulation types. HMWPE = HIGH MOLECULAR WEIGHT POLYETHYLENE Polyethylene (PE) is polymerized ethylene (C 2 H 4 )n, a highly crystalline, lightweight thermoplastic. Outstanding characteristics are chemical resistance, toughness (even at low temperatures), dielectric properties, water vapour impermeability, and relatively high softening temperature. The term Polyethylene usually refers to polymerized ethylene of molecular weight > 6000, commonly referred to as High Molecular Weight Polyethylene (HMWPE). Copolymers of polyethylene are also widely used and are sometimes referred to as polyethylene even though PE may comprise only 50% of the total material. PE may be "linear" or "branched", as determined largely by the pressure and temperature in the manufacturing reactor. Linear PE involves relatively low pressure / temperature compared to Branched PE. For Linear PE, density is also affected by the quantity of comonomer used with the ethylene feed stock. The proportionally more the comonomer, the lower the density. A range of density grades of High Molecular Weight Polyethylene are available. ASTM D 1248, for example, recognizes 4 distinct Types of PE according to density, whereas the Condensed Chemical Dictionary defines 3 Grades for HMWPE as Low, Medium or High. It should be noted that ASTM D1248 does not use the term High Molecular Weight anywhere in the Standard. Even though most manufacturers of PE insulated cable for the Cathodic Protection industry reference ASTM D 1248, they also include the words High Molecular Weight Polyethylene (HMWPE) in their product description. Kalas Manufacturing, for example, describes their Cathodic Protection Cable Standard insulation as Low Density High Molecular Weight Polyethylene (HMWPE), 75 o C, 600 Volt; conforms to the following Electrical Cables for Cathodic Protection.doc Last printed 1/24/2006 11:45 AM Page 3 of 6

specifications or testing methods: ASTM D 1248, Type 1, Class C, Category 5, Grade E-4 and E-5. Table 4 lists the Density ranges as defined by the specification and compares these values to plastics industry terminology. Table 5 lists Molecular Weight according to industry terminology TABLE 4: Density of PE and Plastics Industry Terminology D1248 Density Plastics Industry TYPE Range Terminology Density Acronym I 0.910 to 0.925 Low Density <0.92 LDPE II 0.926 to 0.940 Medium Density HDPE III 0.941-0.959 HDPE High Density >0.94 IV 0.960 and higher UHDPE TABLE 5: Molecular Weight of PE, and Plastics Industry Terminology MOLECULAR WEIGHT TERMINOLOGY ACRONYM 50,000 to 250,000 Low Molecular Weight 250,000 to 1,500,000 High Molecular Weight HMWPE XLPE = CROSSLINKED PE (Irradiated PE) A radiation process is used to change the physical properties of materials through ionization of atoms and molecules to create free radicals. Crosslinking of wire and cable insulation can improve stress-crack, abrasion and deformation resistance, service temperatures, and resistance to the action of fluids. Polyethylene insulation or jacketing for CP cable is not necessarily "cross linked" (XL) or "irradiated." "EXAR" (Champlain) and "CATHORAD" (Judd) are irradiated kynar insulations, with a HMWPE jacket. XLPE - PVC (insulation / jacket) cable is a commonly specified in the UK, wherein the XL prefix means "irradiated". PVC = POLYVINYL CHLORIDE The most significant commercial vinyl, made from chlorine and ethylene, with a polymerization reaction, ending up partially crystalline. PVC is sensitive to environmental salt content. History of PVC and HMWPE for CP Cable Insulation: Reference: Hugo, L.A. et al., "Advantages of HD Polyolefin for CP" Material Protection, Feb. 1962, pp 38-44. Before HMWPE became the dominant insulation for CP cable in North America, other materials experienced problems. Rubber insulated, neoprene jacketed cable failed in ground saturated with oil or gas, or when the neoprene jacket was damaged. 600V PVC cable failed at locations in or near salt water due to insulation blistering and embrittlement. Failures were reduced from salt by insulating with PE and jacketing with PVC, but in due course, failures attributed to distortion of the PVC occurred. Phillips Petroleum carried out extensive testing and development which led, in part to the wide acceptance of HMWPE insulation of 0.110" (2.8mm) thickness in North America. Eventually, due to problems in deep wells attributed to concentration of chlorine, most deep well applications in North America utilize Kynar or Halar insulated, HMWPE jacketed cables, rather than standard HMWPE. Electrical Cables for Cathodic Protection.doc Last printed 1/24/2006 11:45 AM Page 4 of 6

HMWPE in chlorine (halogen) environments: Reference: Thomas F. Lewicki, "Premature Failure of Anodes in Deep Ground Beds", Corrosion/80 Paper 243 (NACE). When HMWPE was used in deep wells where halogen gases evolved under concentrating conditions, failures were experienced in anode beds. Investigations made by Thomas Lewicki for The US Air Force in the 1970's established that the HMWPE, rather than the anode or connection seal, was the problem; and that HALAR insulation was reliable. KYNAR cables have also proven reliable in deep well applications. HALAR and KYNAR insulation: HALAR and KYNAR are trademark-registered plastics. CP cables made with HALAR and KYNAR and jacketed with HMWPE, are more costly than plain HMWPE. HALAR is a flouropolymer (Ethylene-chlorotrifluoroethylene copolymer, ECTFE) sold by Ausimont. ECTFE is resistant to most corrosive chemicals and organic solvents at room and elevated temperatures. Its dielectric constant (2.6) is low and stable over a wide temperature range. KYNAR is Polyvinylidene Fluoride (PVDF), which can be crosslinked by irradiation. It is a product of Atochem very resistant to attack or penetration by most corrosive chemicals and solvents, including inorganic acids, oxidants, alkalines, halogens and hydrocarbons. HALAR and KYNAR becomes "notch sensitive" with increasing thickness; but the 0.20" (0.5mm) thick insulation for CP cables is thin enough to functions reliably under 0.07" thick HMWPE jacketing. Caution: The CP practitioner must be aware that HALAR or KYNAR as trade names in contract documents do not precisely define the quality of material which the customer's application may require. One manufacturer's KYNAR insulated cable may not be to the same standard or grade as another manufacturer's KYNAR cable. SLEEVES: Added protection against halogen attack may be obtained by the installation of a heat shrink sleeve around the insulation in the vicinity of the anode. One customer requires 2m of radiation crosslinked adhesive coated heat shrinkable polyolefin sleeve of 2mm wall thickness minimum (epoxy) encapsulated for 130mm in the anode. INSPECTION, TESTING AND HANDLING OF CP CABLES For a cable to serve reliably it must arrive at the site and be installed without damage to its insulation. Avoid: Contact with sharp, penetrating, or highly abrasive surfaces (cable protectors for anode or epoxy) Bending or forming to tight radii (temperature sensitivity, packaging design) Contact with potentially damaging chemicals or radiation (excessive sunlight). Cable can be tested for defects in the insulation: At the Anode-Cable Assembly Plant: Holiday Detector: Tinker & Razor Model APW, Pulse Type, at (say) 18000V output to meet ARAMCO 17-SAMSS-007 requirements. At the Cable Manufacturer's Production Plant: Voltage Testing: ICEA S-61-402, NEMA WC5: Voltage and Spark Tests to verify insulation integrity. Electrical Cables for Cathodic Protection.doc Last printed 1/24/2006 11:45 AM Page 5 of 6

Other methods and equipment may be applicable, but the inspection tests described have been practically applied commercially in North America. For the UK, BS 6195 (Appendices C and D) describes Production and Manufacturer wet and spark testing for cables specified and used by CP practitioners of British persuasion. INSULATION Typical "HMWPE" Cautions: Material: Thickness (usual) 0.110" (2.8mm) TABLE 6 TYPICAL WORDING from VARIOUS NORTH AMERICAN STANDARDS, with options FOR CATHODIC PROTECTION CABLE INSULATION (Details have been omitted for simplicity) Details and Comments Insulation shall conform to ASTM D1248 Type 1, Class C, Category 5, Grades E-4 and E-5. Surface Printed "Manufacturer Name, AWG Size" Although "HMWPE" may appear to infer "High Density", this is a misinterpretation. HMWPE may be of Low, Medium or High Density. Refer to manufacturers' Specifications. POLYETHYLENE CLASS GRADE: (for example: E4 or E5) Molding and Additives and "E" for insulation, "J" for jacketing Extrusion Antioxidants "Grade" related test qualities include: Standard: ASTM D-1248 A (None) Tensile Elongation B (Some) C (Weather Crack Resistance Dielectric constant Resistivity Typical "KYNAR" Spec. for PVDF = Polyvinylidene Fluoride Comment and Caution: Typical "HALAR" Spec. for ECTFE = Ethylene Chlorotrifluoroethylene Comment and Caution: Resistant) Water Stability Primary Insulation shall be irradiated cross-linked extruded PVDF. The Outer Jacket shall be black, high density and high molecular weight polyethylene (HMWPE) conforming to ASTM D1248, Type 3, class C Category 5 of minimum density 0.941 grams per cubic centimetre. Kynar is not always irradiation cross-linked for improved resistance to flow at temperatures above normal melt point or for improved resistance to electron or gamma radiation. Grade/Density influences the efficiency of cross-linking. Manufacturers use Trade Names such as "PERMARAD" (Raychem) and "CATHORAD" (Judd), and their bulletins may not specify Grade/Density. Kynar is more costly than HMWPE. Primary Insulation shall be natural Halar 0.020" minimum thickness. The Outer Jacket shall be black High Molecular Weight Polyethylene of minimum wall thickness 0.064", conforming to ASTM D1248 Type 1, Class A, Category 5, Grades E4 and E5, Tensile Strengths J1 and J3. Halar is more costly than HMWPE. For selection, specifications and properties should be assessed. A minor point: In this instance the specification needed only to reference the Grades J4 and J5 for the HMWPE jacket over the Halar insulation. References: 1. Modern Plastics Encyclopedia 1990 2. The Condensed Chemical Dictionary Fourth Printing (1969) 3. ASTM D 1248 Polyethylene Plastics Molding and Extrusion Materials. 4. ASTM D 1351 Polyethylene Insulation for Electrical Wire and Cable 5. Lewicki T.F., "Premature Failure of Anodes in Deep Ground Beds", Corrosion/80 Paper 243 (NACE). (L24) Electrical Cables for Cathodic Protection.doc Last printed 1/24/2006 11:45 AM Page 6 of 6