Fire Suppression Systems for Your Home



Similar documents
Fighting Fire in Sprinklered Buildings. Student Guide

WHAT YOU NEED TO KNOW ABOUT INSURING A HOME WITH FIRE SPRINKLERS

AT&T Internet Data Center Site Specification San Diego Koll (San Diego, CA)

MARKETING HOMES PROTECTED BY FIRE SPRINKLER SYSTEMS

H O M E F I R E S P R I N K L E R S S A V E L I V E S, M O N E Y A N D W A T E R A G U I D E F O R W A T E R P U R V E Y O R S

F.Y.I. Specifying Fire Protection Systems Using Division 13

Fire Protection of Data Centres

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

FIVE YEAR CERTIFICATION REPORT

AT&T Internet Data Center Site Specification - Phoenix Area (Mesa, AZ)

Mission-critical fire protection HI-FOG for data centres

Appendix B Forms for Inspection, Testing, and Maintenance

Watermist fire suppression systems for commercial low hazard occupancies

Risk Control Bulletin Inspection, Testing & Maintenance (ITM) of Water-Based Fire Protection Systems

All about. insurance and. water damage

later damage - Loss ControL

Mission-critical fire protection HI-FOG for large data centres

Supplying water to: HYDRANTS on Water Utility Mains BUILDING FIRE SERVICES

Inspection and Testing of Water-Based Systems

Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009

AT&T Internet Data Center Site Specification Chicago Area (Lisle, IL)

Fire detection, alarm, and suppression systems are installed to:

Firefighter Review. Instructor Guide

SEVERE WINTER WEATHER PROPERTY RISK CONTROL

Public Safety Advisory On Potential Roof Collapses

Ontario Association of Fire Chiefs Position Paper Residential Fire Sprinklers

FIRE-FIGHTING DESIGN BRIEF REPORT

Fire Safety Risk Assessment Checklist for Residential Care Premises

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D

Maintaining Fire Protection Systems

FIRE INSURANCE CLAUSES

MOTOR FUEL DISPENSING SAFETY

Sprinkler and Fire Alarm Systems for the Building Official

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

FPS4 APPENDIX A (INTERIM) SPECIFICATION FOR THE INSPECTION AND TESTING OF AUTOMATIC FIRE SPRINKLER SYSTEMS

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS

Home Fire Sprinkler Facts vs. Myths

EFSN Training i Module Minutes

SITE INSPECTION CHECKLIST

san francisco//usa data center specifications tel: fax: internet + intellectual property + intelligence

Risk Management Guidelines

Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1

Fire Detection, Protection, and Suppression Systems. Objectives (1 of 5) Objectives (2 of 5) Chapter 36

NeuStar Ultra Services Physical Security Overview

GET READY FOR A BUSH FIRE FOUR SIMPLE STEPS TO MAKING YOUR BUSH FIRE SURVIVAL PLAN

IFE Level 4 Certificate in Fire Science and Fire Safety (HL)

Risk Guidance Note 03. Management of In-Rack Automatic Sprinklers (IRAS)

Transformer Deluge Systems

Fire and Security Products and Services

SPECIAL PROVISIONS ñ NEW YORK

Risk Management Report

Building Services Engineering Technician

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

EXHIBIT A SCOPE OF WORK

HSE information sheet. Fire and explosion hazards in offshore gas turbines. Offshore Information Sheet No. 10/2008

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description

Name Of Occupancy Date. Yes No Describe

Your Pressure Sewerage System Guide

C I T Y O F S E L M A F I R E D E P A R T M E N T

Cost Evaluation of Black Steel Pipe and Galvanized Pipe When Using a Nitrogen Generator

- Save lives and reduce material damage

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS

AT&T Internet Data Center Site Specification New York III (Secaucus, NJ)

Winter freeze protection for buildings

Protect your pipes. Keep the water cycle running smoothly and be prepared in winter. Heat, insulate and protect your home.

AFS Center. Data Center Info. Arizona Facility Services 2331 West Alameda Dr Tempe, AZ (602) Main (602) Fax

SPRINKLER RULES & STANDARDS IN EUROPE CEA 4001 & EN 12845

Sprinkler Systems in Hospitals. Lisbon 6 November 2008

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No

contractors, etc. and establish relationships with lease and rental companies.

Vacant properties. Understanding the risks and the solutions

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

Fire Sprinkler System Maintenance and Testing Page 1 MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

Australian/New Zealand Standard

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description.

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

FIREFIGHTER SAFETY. Stay safe during substation fires

Veterans Memorial Coliseum Options Study Appendix A - Deconstruction Scope of Work and Cost Estimate August 31, 2015

How To Visit An Internet Data Center

Fire-Rated Glass and Glazing START

LCT 1025 (08/08) Copyright 2008 Harleysville Mutual Insurance Company Page 1 of 5 All rights reserved

Viking Residential Sprinkler Installation Guide

Liberty Mutual Insurance RISK ENGINEERING PROCEDURE. REP 07 Incident Planning For external use

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.

SUMP PUMP DISCHARGES INFORMATIONAL PACKET

We look forward to working with you. Worldwide Headquarters 1400 Pennbrook Parkway Lansdale, PA

Static Spark Ignites Flammable Liquid during Portable Tank Filling Operation

DEPARTMENT OF CONSUMER AND INDUSTRY SERVICES DIRECTOR'S OFFICE

Iron Hill Corporate Center Newark, DE

TEXAS STATE BOARD OF PLUMBING EXAMINERS EXAMINATION AND REGISTRATION Endorsement Training Programs

How To Fix A Gutter Clog

COMMON MYTHS ABOUT FIRE SPRINKLER PROTECTION

The Smarter Way of Fire Fighting Fire Fighting with Water Mist

Location. Central Business District. Ataturk Airport IFC. Sabiha Gökçen Airport

NFPA FAQs. 3. Can plastic pipe be used on a sprinkler system complying with NFPA 13?

BUILD FOR QUALITY BUILD FOR VALUE BUILD FOR LIFE

Why Insurance Cost are Rising for Biogas Power Generation Plants

ENVIRONMENTAL HEALTH AND SAFETY. Fire Protection System Impairment Procedure

Transcription:

ABN 64 127 735 433 PO Box 395 Mundaring. 6073. Phone/fax 9295 6263. Mob 0439 971 213 office@waterinstallations.com 18 Wandeara Cres, Mundaring. 6073. Fire Suppression Systems for Your Home Hills residents are only too familiar with bush fire risk. Every summer is a concern for FESA due to often low winter rainfall and rising accumulation of leaf litter. There are many strategies that households can undertake to make the fire risk to their property as low as possible. Installing some sort of watering system to suppress fire is an obvious no-brainer said Ross Mars from local water specialist Water Installations. Either a roof-mounted sprinkler system and/or a perimeter spray network may enable householders to better protect their home. In extreme conditions these systems may not be enough, but it should still be an essential part of the homeowner s fire strategy. Water Installations have installed a number of different types of home-protection systems, typically linked to petrol or diesel driven pumps that use tank rainwater or draw from a backyard pool. You need at least 25,000 to 30,000 L storage if you wanted enough water to help fight a fire for about 30 minutes Ross said. Wet Sprinkler Systems The sprinklers in these systems are attached to pipes containing pressurized water at all times. When one or more sprinkler heads open, water is automatically discharged. Heat melts or shatters the glass bulb or a soft metal link which then allows water to flow. Wet-pipe systems are used wherever temperatures are high enough to prevent freezing. Water expands when it freezes, this causes water filled pipes to burst and become ineffective. Burst pipes decrease your fire suppression capabilities and can cause significant water damage. Most common in public buildings. Typically, there is a network of overhead sprinklers with the pipework throughout ceiling or roof space. Dry Sprinkler Systems In a dry-pipe system, sprinklers are attached to pipes that contain pressurised air. When heat activates the sprinklers to open, the air pressure is reduced, allowing the dry pipe valve to open and water to flow from the sprinkler. Dry-pipe systems are usually used only when temperatures are not high enough to prevent freezing. A special valve blocks the entry of water into the piping, and as you need a compressor this system is not common in houses, but mainly used in some types of larger buildings. 1

Pre-action Sprinkler Systems These systems contain an additional fire-detection device that will recognise a fire before the sprinklers are activated. The sprinklers are attached to a pipe containing air that may or may not be pressurised. When the detection device senses a fire, it opens the main valve, allowing water to flow through the pipes before the sprinklers are set off. When the heat activates the sprinklers, water flows through immediately, as in a wet-pipe system. Pre-action systems are usually employed in areas that are at risk for serious water damage due to damaged sprinklers and/or piping, such as computer rooms or where valuable equipment is stored. They operate faster than dry systems, but tend to be significantly more expensive as you need both a fire detection system (smoke, heat detectors) wired to the pre-action valve which is opened only when fire detection system is activated and a sprinkler head opening before water is released. Deluge Sprinkler Systems These are the most common for houses. In these systems, sprinklers are open at all times. They are connected to a dry pipe that is connected to a water supply a rainwater tank, dam, pool or mains water. Operation can be manual (person opens valve to activate) or a fire detection device controls the main valve. When it is activated, the valve opens, allowing large amounts of water to flow through all of the sprinklers. The purpose of a deluge system is to quickly wet down an entire hazardous area to prevent a fire from spreading. They can be installed inside rooms but typically are sprinklers on roof areas and around the perimeter of a house. These ensure good coverage of walls, windows and surrounding grounds to thoroughly wet the area. Misting sprays are sometimes used but they will have little effect on an intense fire and are not recommended for bush areas. (R) Perimeter sprinkler high impact with a throw radius of about 10m. (below) Brass sprinklers and steel pipework are best for fire suppression systems. Poly pipe and fittings will easily melt under intense heat. 2

(Above and below). An isolated house during the Margaret River bushfires in November, 2011. It was saved as there was a perimeter sprinkler system which was automatically activated by heat. 3