SMALL GAS OPERATOR OPERATION AND MAINTENANCE PLAN



Similar documents
AT&T Global Network Client for Windows Product Support Matrix January 29, 2015

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

Underground Storage Tanks

Installation of Underground LP-Gas Systems

Enhanced Vessel Traffic Management System Booking Slots Available and Vessels Booked per Day From 12-JAN-2016 To 30-JUN-2017

Your safety and the safety of others are very important.

Analysis One Code Desc. Transaction Amount. Fiscal Period

Case 2:08-cv ABC-E Document 1-4 Filed 04/15/2008 Page 1 of 138. Exhibit 8

CHAPTER X GAS LEAKAGE CONTROL GUIDELINES FOR PETROLEUM GAS SYSTEMS

49 CFR 192 Transportation of Natural and Other Gas By Pipeline: Minimum Federal Safety Standards

ASMECourseCatalog.

Operations and Maintenance Procedures for Natural Gas Systems

Cathodic Protection Use On Tank Bottoms & Underground Piping In Power Generation Plants

Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

Tennessee Gas Association

Subpart XX Standards of Performance. Terminals. Environmental Protection Agency

SOCALGAS APROACH TO PIPELINE INTEGRITY

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.

CATHODIC PROTECTION SYSTEM DESIGN

CHAPTER VIII. completeness of the operations and maintenance procedures; omission or deficiency of an applicable portion of the plan;

Chapter 19 Purging Air from Piping and Vessels in Hydrocarbon Service


Ashley Institute of Training Schedule of VET Tuition Fees 2015

Inspections Standard Operating Procedure 5 Aboveground Storage Tanks

FIVE YEAR CERTIFICATION REPORT

Fire Sprinkler System Maintenance and Testing Page 1 MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

MAR Sincerely,

NFPA31FuelOilPiping 1 Revised

Abnormal Operating Conditions Emergency Plans and Public Awareness Plans for Natural Gas Systems

2016 Dry Cleaning Compliance Calendar

G SPECIFICATION: GAS METER AND REGULATOR INSTALLATION REQUIREMENTS. 3 and Gas Yellow Book. REVISIONS: (See ) 1/15/14 5 Years

NCCER Progress Blvd., Alachua, FL Tel: (888) Task Number Item Date(s) Recorded By

Owner-User Pressure Equipment Integrity Management Requirements

SANITARY GRAVITY SEWER LINE TESTING. B. Section CCTV Inspection of Gravity Sewer Lines

OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES

Natural Gas Wholesale Prices at PG&E Citygate as of November 7, 2006

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

A GROUNDWATER PROTECTION PLAN FOR HOME HEATING OIL TANKS

Below Grade Spill Containment Manholes Gallon Gallon Gallon. Installation Instructions

Detailed guidance for employers

NW Natural & Pipeline Safety

LIQUEFIED PETROLEUM GASES

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Anode Rods, Cathodic Protection and the Porcelain (glass) Lining

SECTION POINT REPAIRS TO SANITARY SEWERS. A. Repairs to existing sewer lines by replacing short lengths of failed pipe.

Natural Gas Emergencies

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

SANITARY SEWER SPECIFICATIONS

DRAFT REVISED Musts For USTs DRAFT. Printed on Recycled Paper. Updated June 2015

Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE

ENVIRONMENTAL HEALTH AND SAFETY. Fire Protection System Impairment Procedure

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

EXHIBIT A SCOPE OF WORK

Refrigeration Installation 101

Jeff Haby, P.E. Director Sewer System Improvements. September 15, Agenda

CHAPTER 6 - SANITARY SEWER

Multiple Meter Installation Amperes Per Position -Single Phase, Self-contained

This will also provide you with the knowledge to insure long life for your Investment

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA (7300 Short Road, Serene Lakes)

The following definitions apply with regard to requirements specified in this document:

Notes. Material 1. Appropriate Flammable Liquids

The Pipelines Regulations, 2000

District Cooling Best Practices Piping Systems

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

SFI SPECIFICATION 28.1 EFFECTIVE: SEPTEMBER 23, 2011 *

BERMAD Fire Protection

MERCER ISLAND FIRE DEPARTMENT FIRE COMMERCIAL SPRINKLER STANDARDS

A Job Safety Execution Plan is required. mixtures of the above called, natural gas liquids (NGL's) refined products and their components

OREGON FIRE CODE Interpretations and Technical Advisories

CENTERPOINT ENERGY TEXARKANA SERVICE AREA GAS SUPPLY RATE (GSR) JULY Small Commercial Service (SCS-1) GSR

Northern Region. Underground Storage Tank

DECEMBER 21, Sincerely, Jeffrey D. Wiese Associate Administrator for Pipeline Safety

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

Central Hudson Gas & Electric

Choosing a Cell Phone Plan-Verizon

CHAPTER IV SPECIAL REGULATIONS - GAS UTILITIES ONLY. Records. Each gas utility shall maintain and keep the following records:

EXHIBIT A SCOPE OF SERVICES WATER SERVICE REPLACEMENT PROJECT. BROWARD OPERATIONS CENTER 5548 NW 9 th AVENUE FORT LAUDERDALE, FLORIDA 33309

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

List of Frequently Utilized Storage Tank Standards and Practices

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)

ACS.VESLP1.LIMITED SCOPE SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC.LPG GAS STORAGE VESSELS

SAFETY AND HEALTH PROGRAM

Beacon Hill Sewer District Standard Specifications

Inspection, Testing and Maintenance

Create Stoplight charts using Milestones Professional

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

P/T 2B: 2 nd Half of Term (8 weeks) Start: 25-AUG-2014 End: 19-OCT-2014 Start: 20-OCT-2014 End: 14-DEC-2014

P/T 2B: 2 nd Half of Term (8 weeks) Start: 26-AUG-2013 End: 20-OCT-2013 Start: 21-OCT-2013 End: 15-DEC-2013

Rental Services Temporary Cooling - Flexible Water Hose

P/T 2B: 2 nd Half of Term (8 weeks) Start: 24-AUG-2015 End: 18-OCT-2015 Start: 19-OCT-2015 End: 13-DEC-2015

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR THE CONTROL OF HAZARDOUS ENERGY (LOCKOUT / TAGOUT) SECTION: 2400

Transcription:

SMALL GAS OPERATOR OPERATION AND MAINTENANCE PLAN Facility Name: Address: QUALIFIED PERSONNEL All tasks shall be completed by a person that is qualified to that task (see operators qualification of individuals and record of qualifications) record shall be maintained for a period of five (5) years. This is per CFR 192.801, Sub Part N. OPERATING PROCEDURE The personnel responsible for the operation and maintenance of the gas system must be trained in the use of the procedures contained in this Operation and Maintenance Plan. The plan will be reviewed once each calendar year not to exceed 15 months by all applicable personnel. A record of review will be maintained (See attachment 2). DISTRIBUTION SYSTEM The distribution system consists of the following: Pipe Section 1 Pipe Section 2 Type Material Diameter of Pipe Ft Above ground Ft Below ground Total feet Date Installed ODORIZATION Gas odorant will be verified through a written statement of odorization from the gas supplier. LEAKAGE SURVEYS There shall be a gas detector leak survey conducted on all exterior portions of the operator s gas distribution system at intervals not exceeding 15 months, but at least once each calendar year or once every 5 calendar years not exceeding 63 months, depending on the location of the operator. All leaks will be repaired promptly. A record will be made of all leaks and repairs (See attachment 2). VALVE MAINTENANCE ON DISTRIBUTION SYSTEMS Exterior key valves in the distribution systems shall be inspected, operated, and lubricated (if necessary) at intervals not exceeding 15 months, but at least once each calendar year (See attachment 2). CORROSION CONTROL Metal piping systems will be protected from the effects of rust (corrosion). Above ground piping and below ground piping must be electrically separated by the use of isolation unions (unions that have a non-conductive electrical gasket separating the two parts). Above ground piping will be protected by the use of coatings (painting) of the pipe. This will place a barrier between the pipe and the outside elements. This protection must be suitable to prevent corrosion caused by moisture, i.e.: rain, fog, sprinklers, coolers, or any other source of water. Below ground metal piping will be protected from the effects of rust through the use of cathodic protection. Cathodic protection is a procedure in which underground metal piping is protected from corrosion by either sacrificial anodes or the use of special anodes and an electrical rectifier. To achieve

and maintain corrosion prevention of underground metal piping, electrical readings of the pipe-to-soil must be taken once each calendar year not to exceed 15 months between tests. Electrical readings are measured with the use of a voltmeter and a reference cell (copper sulfate cell). The voltmeter has two test leads which are red and black in color. The red test lead is connected to the positive terminal of the voltmeter (indicated by red) and to the reference cell. The black test lead is connected to the common terminal of the voltmeter (indicated by black) and to the pipe. The voltmeter must be set to read, Direct Current Volts, which will be indicated on the display screen by the symbol VDC. Electrical readings indicated by the voltmeter shall be a minimum of 0.85 volt. Anytime a reading is less than 0.85 volt, investigation and repair will be completed to ensure the continued prevention of corrosion. Electrical readings must be taken at a sufficient number of locations and near mid-points between sacrificial anodes to assure steel piping is being adequately protected (See attachment 2). DAMAGE PREVENTION No person or company shall begin any excavation on the operator s properties before notifying the operator. When notified of an excavation, the operator will locate their natural gas lines as local rules require. All marks for gas lines will be yellow in color. Location requests will be documented. INVESTIGATIONS OF FAILURES Reportable failures and accidents are to be reported to the Utah Office of Pipeline Safety, by telephone, as soon as possible at (801) 530-6673. If it is determined that the location of gas facilities contributed to an accident or failure, action will be taken to minimize the possibility of recurrence. REPAIR METHODS - PLASTIC AND METAL Repairs will only be completed by persons with training and experience. If such personnel are not available, arrangements will be made with a qualified gas contractor or gas company to perform such work. All work will comply with Title 49, CFR part 192. Records should be maintained for all repairs made to the operator s natural gas system. (Records should be maintained for the life of the system) ABANDONMENT OF DISTRIBUTION GAS LINES If the gas lines are to be abandoned in place, they shall be physically disconnected from the gas system. The open ends of the lines shall be plugged or capped. Purging the abandoned lines, to prevent the development of a potentially hazardous condition, will be done by filling the line with water or an inert material. Abandoned gas lines shall be indicated on the system maps. All gas valve boxes shall be filled to grade with sand or a suitable substitute. DISCONTINUED SERVICE Whenever gas service to a unit is discontinued, one of the following will be complied with: 1) The valve that is closed to prevent the flow of gas into the unit must be provided with a locking device or other means designed to prevent the opening of the valve by persons other than those authorized by the operator. 2) A mechanical device or fitting that will prevent the flow of gas must be installed in the service line riser. 3) The unit must be physically disconnected from the gas supply and the open pipe sealed. 2 Revised, Jan 2011

PRESSURE TEST REQUIREMENTS Each new, replacement, reinstated or uprated pipe will be subjected to the pressure test required in accordance with 49 CFR 192, prior to being filled with gas and put in service. Systems operating below one (1) PSIG: (Steel and Plastic) *Steel: Test at 10 PSIG for one hour. Test gauge shall be a minimum of 30 PSIG and calibrated on 1/10 PSIG increments. *Plastic: Test at 60 PSIG for one hour. Test gauge shall be a minimum of 100 PSIG and calibrated on 1 PSIG increments. *If tests are required by local jurisdictions, tests shall be that which is more restrictive. System operating at one (1) PSIG or greater: This test consists of putting 60 PSIG or 1 1/2 times the MAOP of the system, whichever is greater on the line after it has been fabricated and placed in the trench and just prior to making the tie-in connections. The test pressure will be applied, given time to stabilize and test observed for the time duration of one hour (test gauge shall be calibrated on one (1) PSIG increments). Each pressure test will be recorded. SERVICE REGULATORS Regulators will be inspected for proper operation each time it is changed or turned on. RECORDS KEEPING PROCEDURES Records will be maintained and readily available on all new piping system installations, repairs and/or changes to existing piping systems in sufficient detail to provide historical information, physical location, design ratings, and any other pertinent data necessary for the safe and continuous operation and maintenance of the system and should be filed as a permanent record for the life of the system. SYSTEM MAPS System maps should be updated on as needed basis. Current map will be detailed enough to conduct a complete survey of the gas system. PREVENTION OF ACCIDENTAL IGNITION Each operator shall take the necessary actions to minimize and or eliminate all sources of ignition in all environments where the presence of natural gas or propane vapors may constitute a hazard of fire or explosion. Every operator must develop a procedure to address the prevention of accidental ignition covering any task on the pipeline that may result in the release of natural gas or propane including but not limited to; venting, purging, tapping, cutting, repairing and replacing pipeline, etc.

Attachment 1 PUBLIC SERVICE COMMISSION OF UTAH Pipeline Safety Section MAINTENANCE SCHEDULE TASK DESCRIPTION JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 1. Emergency Plan Review (192.605) 2. O & M Plan Review (192.605) 3. Gas Leak Survey Record (192.723 4. Gas Leak Repair Record 5. Valve Inspection Record (192.747) 6. Corrosion Control Test Data (192.465, 192.481) REQUIRED INTERVALS: Emergency Plan Review (a), O&M Plan Review (a), Gas Leak Survey (a) or (b), Corrosion Control Test (a) and/or (c),valve Inspection (a), Odorant Certification (one time), Record Repairs (d) (a) = Once each calendar year with intervals not exceeding 15 months (b) = Once every 5 calendar years at intervals not exceeding 63 months, depending on location. (c) = Once every 3 calendar years, at intervals not exceeding 39 months (d) = Whenever repairs are made, Record inspection data on appropriate forms.

Attachment 2 Year: Review Records Emergency Plan Review Record Date Name/Title Signature Title Operation & Maintenance Review Record Date Name/Title Signature Title Gas leak Survey Record Date Area Surveyed Survey By Valve Inspection Record Date Valve ID Inspected By Corrosion Control Record Date Location Pipe/Soil Reading Tested By Odorization Certification From Gas Supplier Date of Request Date of Receipt Gas Leak Repair Record Date Location Repaired By