Integrated Home Networks



Similar documents
Enterphone Solo. User/Installation Manual Part No

FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc rd Street San Francisco, CA Phone:

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

Telephone Line Distribution Module

PHONE WIRE PHONE JACKS & PHONE PLUGS. Modular plugs are made in three sizes:

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

Installation Manual For Support Call or

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

3 KRONE s 25-Pair FT Block is the perfect replacement

CABLE TERMINATION BEST PRACTICES A guide to improved cable performance through proper termination and installation.

Square D Multi-Link Structured Wiring System Increase Your Home s Value and Convenience

USB Rover port USB m Cat 5 Extender. User Guide

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

47611-GB4. Quick-Start Guide 10/100/1000 Mbps 4-Port Gigabit Router IMPORTANT INSTRUCTIONS SAFETY INFORMATION PRE-INSTALLATION CHECKLIST

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

Welcome. Digital Phone. Digital Phone. Digital Phone

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

Catalog Issued 8-00

3M Quick Connect System (QCS) 2810 Models 2810A and 2810B

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

Ethernet Cat 5e & Cat 6 Patch Panels

QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000

SQUARE D Multi-Link Structured Wiring System

e-ask electronic Access Security Keyless-entry

OWNERS MANUAL CONTENTS: Introduction.. 2. Definitions.. 2. Smartwire.. 4. Computing Network 7. Working diagram. 8. Television Antennas 9

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

Part No. P Business Communications Manager 2.5. BIX Box Wiring Guide

hello. welcome to smart watering.

Terminating 25-Pair Cable and 4-Pair Cross Connects

TAC1 Telephone Entry System Installation and Programming Manual

How To Install A Doorbell Fon Unit

Comtrol Cable User Guide

Zetron Desktop Microphone Manual F

KVM - DVI, USB 2.0, Cat 5 Extender

Vertical Phone System Upgrades Scope of Work

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

CONSOLE REMOTE I /O AC 9V

ReadyNet Easy Jack 2 Voice/Data and Data Only Owner s Manual PX-211d and PX-211v

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

TCB-2 Auto Answer Coupler Product Manual

E Series. E Series. Category 6 and 5e. Features

I Click on a link tab to jump to that page. Cover Page

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

ChargePoint Home. Installation Guide. ATTENTION: Please read thoroughly and keep this installation guide.

BroadBand PowerShield. User Manual

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

LIEBERT VNSA Installation Sheet

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range

Category 6 UTP - Cabling System

ATTACHMENT F 050R CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

Color Mark Sensor with Red or Green LED E3S-VS

Mounting Plate / Screwdriver. Alignment Stickers Screws / Desiccant Bag / Double-sided Tape / Rubber Seal Plug / Rubber Washer

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

PC Tab INSTALLATION MANUAL SECURE-IT, INC. EAST LONGMEADOW, MA / (fax)

Advantium 2 Plus Alarm

Lightning Protection Guide. PTP 400 and 600 SERIES

TELEPHONE CABLING TECHNOLOGY INFINITY CABLING

Take-2 by Nel-Tech Labs, Inc. Installation & User Manual

Innovative DOOR STATION Solutions

Testing, Repairing & Installing Home Telephone Wiring Disclaimer

=============================== WARNING

Model SRMD Setra Remote Monitoring Display

16/32 Channel 1U Rack Mount CCTV Power Supply

Anthro Tablet Charging Cabinets

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide

GSD 22 Sounder Module. installation instructions

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

Product Manual. Precision Inbound Call Routing Fast Outbound Line Hunting Streamlined Telecommunications

T-Extender E-Extender

A guide to connecting to fibre optic networks for homeowners, architects, builders and developers.

How to check for Sync at the NID

Expanding a 40-Type Cabinet

USER MANUAL QUATTRO 3 CONFERENCE SPEAKERPHONE MODEL 302

How To Service A Paper Shredder

Operation and Installation Manual

16-Port and 24-Port 10/100 Switches

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Network Cabling Guide

TCTC Cabling Specifications

ANT1750F Multi-Directional Slim Digital Antenna / Antena multidireccional plana para interiores / Antenne numérique mince multidirectionnelle

How To Set Up A Minipatch System For A Small Office Or Home Use

This Document Contains:

Cat7/Class F New Installation Concept New infrastructure. Handbook

Ethernet Patch Cord Wiring

Christopher Rathgeb ECE 453 Dr. Qi 9/19/2006. Task 1: Make an Ethernet cable yourself.

Juice Box Stages 1&2 135&335 Installation Guide 5/10/08

Terayon DOCSIS Modem Installation. Guide

Transcription:

Integrated Home Networks 8050 Series elephone/data Hubs Instruction Manual & Structured Wiring Guide 8053 8051 8052 8052 multiplex technology, inc. 3001 Enterprise Street, Brea, CA 92821-6213, U.S.A. 714-996-4100 * 800-999-5225 * FAX_714-996-4900 www.channelplus.com

Data/elephone Hub applications POS (Plain Old elephone Service) 8053 o distribute POS, use either an 8051 or an 8053. All connectors are bridged ( wired in parallel ). Use a model 8053 to distribute telephone service. A single model 8053 can handle up to 9 telephones. For more phones, add one 8053 for every 8 telephones. All connectors are bridged (wired in parallel.) From elco Central Office lines (CO) CO1, CO2, CO3, CO4 8051 Expansion connector 8051 Use a model 8051 to distribute telephone service if you prefer to use modular connectors. he model 8051 also provides loopthrough on pair 1 for a security system or a Doorel front door intercom. All connectors are bridged (wired in parallel.) In a structured wiring system, a model 8051 is used to provide selective telephone service. (See the section on Structured Wiring Systems.) Jacks accept 6 position J-25 Or 8 position J-45 plugs o phone jacks 110 punch-down blocks Do not punch-down more than one wire per connector. 8053 8052 In a structured wiring system, a model 8052 is used to provide a termination point for all internal house wiring. (See the section on Structured Wiring Systems.) Each modular connector is individually connected to the 110 punch-down block behind it. ie wrap mounting holes From elco Central Office lines (CO) CO1, CO2, CO3, CO4

Wire Color Codes elephone ermination Band -Stripe wisted-pair Wire Cat5 4 pair UP pair 1 pair 2 blue/white blue orange/white orange Solid Color wisted-pair Wire green IP red ING black IP yellow ING Option 1 - old style Dual Jack elephone Wallplate Orange White/Orange Blue White/Blue Black Yellow ed Brown Pairs 1&2 pair 3 green/white IP white White/Brown pair 4 green brown/white brown ING IP ING blue White/ Black Yellow ed Quad Wire* pair 1 green red IP ING CAUION: Quad wire is no longer acceptable for installations in multi-line environments. etrofit with UP if possible. Pairs 3&4 pair 2 black yellow ACCESSOY GOUND Option 2 - new style Quickport wallplate Cable Color Pin # Connector Color Pin 1 N/C White/Orange Pin 2 White/Orange Blue Pin 3 Blue White/Blue Pin 4 White/Blue Orange Pin 5 Orange Pin 6 N/C Modular connector designations Pairs 1&2 6 position connectors P1 P2 P1 P3 P2 P1 8010 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 Pairs 3&4 8011 J-11 Single line telephones, answering machines 8 position connectors P2 P3 P1 P4 1 2 3 4 5 6 7 8 J-14 J-25 Dual line telephones are & answering 3 line KSU hookups machines J-45 (wired to IA 568A standard) Ethernet (both 10Base and 100Base) Structured wiring of phones and data lines (here are other wiring standards. For residential use, w e recommend that J-45 jacks are wired to the 568A standard.) Cable Color Pin # Connector Color Pin 1 N/C White/Brown Pin 2 White/Orange Pin 3 Blue White/ Pin 4 White/Blue Brown Pin 5 Orange Pin 6 N/C J-14 Voice Grade Jacks 8072

How to wire a new house he Internet, multiple phone lines, cable television, satellite systems, and high speed data links are bringing more and more information to your home. he communication wiring in most houses is overwhelmed by these requirements. It doesn t have to be that way. During construction, providing modern cabling is surprisingly inexpensive. un all wires to a network enclosure. In a typical house, an in-wall cabinet located at the media center will be a good choice. (Large houses may need two or more cabinets to service all of the wires. Since these large cabinets can be unsightly, they are usually placed in a garage, basement, or service room.) Home-run CA-5 and coax cables from each location 2 G-6 to location of satellite dish ypical wallplates Phone only V only When wiring a new house: 1) Establish a distribution point for all data, telephone and coax cables. 2) When possible, have a network enclosure at this location. 3) un cables from each wall outlet back to the network enclosure. his is called home run or star wiring. 4) When in doubt, add the extra wires. When a house is being built, running extra cables is easy. Once the wall board is up, that extra cable will cost 10 times as much. Family room Media center Living room Master suite Determine the wiring scheme that is right for you: Standard: 1 Cat-5 cable to all possible telephone and computer modem locations. 1 G-6 coax to all possible V locations (except the media niche). 3 G-6 coax cables to the media niche (to satellite receiver, to V, from modulator). 2 Cat-5 cables to telephone company entry location. 1 G-6 coax cable to CAV entry point (2 if you have a dual coax cable.) 2 G-6 coax cables to location of satellite dish. Options to the above, add any or all of the following: 1 Cat-5 cable to all computer or printer locations for a home network. nd 2 G-6 coax to all V locations for modulator inputs or satellite feed. 1 G-6 coax + 1 Cat-5 cable to front door for CCV camera and Doorel intercom. 1 G-6 coax and bell wire to any other possible CCV camera locations (swimming pool, side yard, driveway.) he ultimate where cost is no object, solution: Conduit to all locations. emember to install pull cords in conduit. Kitchen 1 G-6 and 1 Cat-5 to front door for intercom and camera. Utility access cabinet Phone lines from elco Coax from cable company Wallplates 8072-2 holes 8074-4 holes 8078-8 holes, dbl gang 8060-2 holes Decora Bedroom Bedroom Home office Home office wallplate has 4 telephone lines, data line, & CAV Jacks 8010-6 conductor J-25 white 8011-6 conductor J-25 gray 8013-8 conductor J-45 blue 8030 - F connector white 8031 - F connector gray 8040 - blank white Consult the ChannelPlus dealer catalog for other wallplate and connector options.

Wiring the 8051 and 8400 he Doorel system allows you to answer your front door from any telephone in the house. When the doorbell rings, pick up the nearest extension and press #. Now you may have a two-way conversation with the person ringing the bell. Doorel Front Door model 8400 Speaker/microphone model 8410 Structured wiring basics: Phones today, data or KSU tomorrow From elco Center Office lines (CO) 8051 CO1 - CO4 he 8051 connects incoming telco wires to 8 J-45 connectors. (he connectors are wired to the IA 568A standard.) he 8051 has a loop-through on pair 1 for a security system, or Doorel front door intercom. power supply model 350-071 Standard Cat-5 jumper cables (8091-1 foot, 8092-2 foot) Switch on 8051 to bypass Doorel Connect with 4 wires elco In to elco In elco In to elco In elco Out to elco Out elco Out to elco Out CA-5 cables o wallplates located throughout ChannelPlus model 8051 8052 Each J-45 jack has its own 8-position 110-type punchdown connector wired to it. he most versatile phone/data systems use structured wiring concepts. he phone/data jacks located throughout the house are each connected to a unique jack on a model 8052 hub. Jumper cables are then used to connect phone, data, or a KSU port to that jack. In this basic system, ordinary telephone service is provided to eight jacks in a house. (o expand, just add another 8051 and 8052 for every eight jacks.)

Structured wiring basics: Changing some jacks to data distribution Structured wiring basics: Connecting to a KSU From elco CO1 - CO4 8051 From elco CO-1 CO3 8051 J-14 ypical wallplate CA-5 jumper cables Jack 1... CO 1/2 Jack 2... CO 3/4 Jack 3... Ethernet Jack 4... Coax CA-5 cables o wallplates located throughout the house J-45 8074 CA-5 cables o wallplates located throughout the house J-45 8052 Standard J-14 jumper cables (2 pair) CA-5 jumper cables 8052 Ethernet Hub ISDN Jack (from elco) In this example, the house has plain old telephone service (POS) on 3 jacks, ISDN service on another, and an Ethernet network on four other jacks. Jacks can be located throughout the house. Changing from one type of service to another is as simple as moving a jumper cable. Blue White/Blue Orange White/Orange White/ J-11 J-11 J-11 CO 1 CO 2 CO 3 Create this custom cable by cutting off one end of a standard Cat-5 jumper. ypical 3x8 KSU (Panasonic KX-30819)

Structured wiring basics: Structured wiring basics: CA 5 wiring techniques Wiring a Cat-5 jack 1 Alternative Ways to Mount the 8050 series hubs. o protect the wiring, the 8050 series hubs should be in a network enclosure. ChannelPlus enclosures allow you to integrate telephone, data, and coax distribution into one convenient location. 110 punchdown tool 2 Keep sheath close to jack. Follow color code for 568A jacks. Position first pair to channel closest to end of jack. (Do not untwist conductor pairs more than 0.5" from the termination point.) Mount on 2600 enclosure... (emove metal bracket from model 8051.) 3 or hang on sheet metal (such as 2602A cabinet)... Using the 110 punch-down tool, push and trim wires into channels and repeat for subsequent pairs. When all conductor pairs are terminated, snap in strain relief caps. Wiring Modular Plug (568A) Insert wires in this order: White/ White/Orange Blue White/Blue Orange White/Brown Brown or mount on 2601 enclosure. Do not untwist more than 0.5"

Structured wiring basics: CA 5 Do's and Don'ts Do not allow cable to kink or knot. Also, do not pull the cable with excessive force. Specifications: dimensions WxHxD: 8051 6.75" x 1.2" x 1.7" (17.1 cm x 3.1 cm x 4.3 cm) 8052/8053 6.75" x 1.2" x 2.2" (17.1 cm x 3.1 cm x 5.5 cm) shipping weight: 1 lb (0.45 kg) Warranty When using tie-wraps Bundle the cables loosely. to secure cable, do not cinch cables to where crush-stress is visible. Do not allow cables to form right angles or sharp bends. Use sweeping bends with a minimum radius of 2". Multiplex echnology, Inc. warrants this products to be free from defects in materials and workmanship for a period of one year from the date of purchase or MI will repair, or at its option, replace the defective product. o obtain warranty service, call MI for a return material authorization (MA) number and return the product prepaid to Multiplex echnology, Inc., 3001 Enterprise Street, Brea, CA 92821, Attention: Customer Service. Please put the MA number on the outside of the carton. Any implied warranty arising from the sale of the product including implied warranties of merchantability and fitness for purpose are limited to the warranty stated above. MI shall not be responsible for losses or damages or expenses, whether direct, consequential or incidental arising from the use of or the inability to use this product. Some states do not allow limitations on how long the implied warranty lasts or the exclusion or limitation or incidental or consequential damages, so the above limitations and exclusions may not apply to you. his warranty gives you specific legal rights, and you may have other rights which may vary from state to state. Integrated Home Networks

multiplex technology, inc. 3001 Enterprise Street, Brea, CA 92821-6213, U.S.A. 714-996-4100 * 800-999-5225 * FAX_714-996-4900 www.channelplus.com 600-099 ev A