Intel IT Redefines the High Density Data Center: 1,100 Watts/Sq. Ft



Similar documents
Data Center 2020: Delivering high density in the Data Center; efficiently and reliably

Thermal Storage System Provides Emergency Data Center Cooling

Managing Data Centre Heat Issues

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

Dealing with Thermal Issues in Data Center Universal Aisle Containment

GREEN DATA CENTER DESIGN

How High Temperature Data Centers and Intel Technologies Decrease Operating Costs

BRUNS-PAK Presents MARK S. EVANKO, Principal

opdc Cut your data center OPEX upto 70%

Solve your IT energy crisis WITH An energy SMArT SoluTIon FroM Dell

Energy Efficient High-tech Buildings

Huawei Data Center Facility Integration Solution

Enabling an agile Data Centre in a (Fr)agile market

Building a data center. C R Srinivasan Tata Communications

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

Power and Cooling Guidelines for Deploying IT in Colocation Data Centers

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

Thermal Mass Availability for Cooling Data Centers during Power Shutdown

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria

Indirect Evaporative Cooling (IDEC) Unit for Data Centers

Data center TCO; a comparison of high-density and low-density spaces

Memory Sizing for Server Virtualization. White Paper Intel Information Technology Computer Manufacturing Server Virtualization

Increasing Data Center Efficiency through Metering and Monitoring Power Usage

Great Lakes Data Room Case Study

Fuel Cell Powered Data Centers: In-Rack DC Generation

NetApp Data Center Design

Data Center Facility Basics

The Pros and Cons of Modular Systems

World s Greenest High Performance Data Center

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

Datacenter Infrastructure Management: Orchestrating Space, Power and Cooling

Impact of Virtualization on Data Center Physical Infrastructure White Paper #27. Tom Brey, IBM Operations Work Group

THE WORLD S MOST EFFICIENT DATA CENTER

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert

How To Test A Theory Of Power Supply

FEAR Model - Review Cell Module Block

Airflow Simulation Solves Data Centre Cooling Problem

Reducing the Annual Cost of a Telecommunications Data Center

DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences

Data Center Power Consumption

Green Data Centre Design

HPC TCO: Cooling and Computer Room Efficiency

Data Center Technology: Physical Infrastructure

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

University of St Andrews. Energy Efficient Data Centre Cooling

Data center upgrade proposal. (phase one)

How To Improve Energy Efficiency In A Data Center

AIA Provider: Colorado Green Building Guild Provider Number: Speaker: Geoff Overland

Data Center Components Overview

Overload Protection in a Dual-Corded Data Center Environment

Rittal Liquid Cooling Series

Air, Fluid Flow, and Thermal Simulation of Data Centers with Autodesk Revit 2013 and Autodesk BIM 360

DataCenter 2020: first results for energy-optimization at existing data centers

Data Centers: How Does It Affect My Building s Energy Use and What Can I Do?

The Next Generation APC by Schneider Electric InfraStruxure

Specialty Environment Design Mission Critical Facilities

Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers

Data Center Equipment Power Trends

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Selecting Rack-Mount Power Distribution Units For High-Efficiency Data Centers

Data Center Infrastructure Management (DCIM) Utility Energy Efficiency Opportunities Discussion & Demos July 2, 2013

High-density modular data center making cloud easier. Frank Zheng Huawei

Sealing Gaps Under IT Racks: CFD Analysis Reveals Significant Savings Potential

Enterprise Data Centres

Ten Steps to Increasing Data Center Efficiency and Availability through Infrastructure Monitoring

Unified Physical Infrastructure (UPI) Strategies for Thermal Management

Reducing Room-Level Bypass Airflow Creates Opportunities to Improve Cooling Capacity and Operating Costs

Data Center Cooling & Air Flow Management. Arnold Murphy, CDCEP, CDCAP March 3, 2015

How green is your data center?

Alan Matzka, P.E., Senior Mechanical Engineer Bradford Consulting Engineers

Datacenter Power Delivery Architectures : Efficiency and Annual Operating Costs

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

Facilities Design for High density Data Centers

Server Technology, Inc.

How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems

Small Data / Telecommunications Room on Slab Floor

Data Centre Testing and Commissioning

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

CUSTOMER EXPERIENCE CENTER

AIRAH Presentation April 30 th 2014

DATA CENTRE DESIGN AND

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Transcription:

Intel IT Redefines the High Density Data Center: 1,100 Watts/Sq. Ft John Musilli- SR Data Center Architect Paul Vaccaro Data Center Solutions Architect

Legal Notices This presentation is for informational purposes only. INTEL MAKES NO WARRANTIES, EXPRESS OR IMPLIED, IN THIS SUMMARY. Intel and the Intel logo are trademarks of Intel Corporation in the U.S. and/or other countries The information contained in this presentation is based on results from Intel s data center design. Intel s design is specific to our environmental needs. Other data center requirements may differ. * Other names and brands may be claimed as the property of others. 2

Business Challenge Increasing Compute is key to getting new product designs Especially SoC (System on a Chip) to market. Intel IT s challenge is to deliver more compute to our design engineers, achieving industry best Cap-X, and industry best Op-X cost models. 3

Key Innovation DC 2 90nM* Key Innovation in HDDC: High density power design lowers construction cost inside the room. <22nM* New Density Model >2014 ~5MW in 43 KSF DC 3 Old Density Model 2005-2013 = HDDC 5MW 5KSF DC1 Cost Advantages/Economies of Density roughly works like Moore s Law As you put more kw into each SqFt of computer room the cost per KW goes down * New density model is the equivalent ratio of space reduction of a 90nM die as compared to a 10nM die. 4

1.1 MW in 40 Rack per Cold Aisle 240 Servers and 960 Cores per Rack 35% more EDA performance, 46% less power, 60% more density Up to 43 kw/rack (1.5x previous high density) Free air cooling (a<95f Intake, except 39 hours/yr.) 1100 W/sq. ft. Density Design PUE 1.1; Actual PUE 1.07 5

800A- 415/240vac Bus Power Distribution 575kW per bus 3 phase 60amp branch circuits Ease of use Flexibility Reliability 11

provide efficient air segregation 7

Cross section airflow and heat map 10

Exhaust air louvers 8

Exhaust to outside Top of Server rack Inside Hot Aisle 10

Reliability: Power Quality Data From June 2011 December 2013 Total Power Quality Incidents Incidents with Multi Phase Impact Longest Duration (Sec) Description Outside IT Equipment Design Specifications Within IT Equipment Designed Operating Specifications Within IT Recommended Operating Specifications SAG Voltage (VAC) 27 0 0.117 Actual Number of Incidents 145-180 6 180-200 5 200-215 16 Percentage of Power Quality Incidents by Type 59% 22% 19% Outside IT Equipment Design Specificati ons Within IT Equipment Design Operating Specificati ons Within IT Equipment Recommen ded Operating Specificati ons 11

PUE AUG/SEP/OCT 2014 12

Results/Conclusions Key Opportunity: Respond to computing demand with a retrofit of decommissioned Wafer Fab Key Innovation: High density power design lowers construction cost inside the room. o o o Inside DC Fit Up at $2,832/kw or $3,625/SqFt 43 kw/rack is 1.5 X greater than previously delivered 1,100 W/SqFt. is 10 times the industry average Key Behavior: Designed with a business appropriate level of facility hardening and redundancy (Tier 1) o o The design from the start used the local Utility power quality and reliability as a specific design assumption The utility power quality and reliability met the customer up time requirements for the intended compute for the data center PUE Trends are exceeding the Design Goal of 1.1 o Ability to rely on cost-effective 100 percent free air cooling for all but 39 hours per year 13

Sharing Intel IT Best Practices With the World Learn more about Intel IT s Initiatives at www.intel.com/it 14

More Information Contact Info john.a.musilli@intel.com paul.vaccaro@intel.com Links to Additional White Papers White Paper: Intel IT Redefines the High-Density Data Center White Paper: Date Center Efficiency and Retrofit Best Practices White Paper: Intel IT's Data Center Strategy for Business Transformation White Paper: Selecting a Data Center Site: Intel's Approach White Paper: Exploring DCIM for Intel's Data Centers 16