Electrophoresis, cleaning up on spin-columns, labeling of PCR products and preparation extended products for sequencing

Similar documents
PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System) 50 preps Product #60200

1/12 Dideoxy DNA Sequencing

ZR DNA Sequencing Clean-up Kit

ZR-96 DNA Sequencing Clean-up Kit Catalog Nos. D4052 & D4053

ISOLATE II PCR and Gel Kit. Product Manual

- In , Allan Maxam and walter Gilbert devised the first method for sequencing DNA fragments containing up to ~ 500 nucleotides.

DNA SEQUENCING (using an ABI automated sequencer)

TIANquick Mini Purification Kit

The Techniques of Molecular Biology: Forensic DNA Fingerprinting

Sanger Sequencing and Quality Assurance. Zbigniew Rudzki Department of Pathology University of Melbourne

Sanger Sequencing: Sample Preparation Guide

Wizard DNA Clean-Up System INSTRUCTIONS FOR USE OF PRODUCT A7280.

Troubleshooting Sequencing Data

ID kit. imegen Anchovies II. and E. japonicus) DNA detection by. User manual. Anchovies species (E. encrasicolus. sequencing.

Southern Blot Analysis (from Baker lab, university of Florida)

Troubleshooting Guide for DNA Electrophoresis

DNA Separation Methods. Chapter 12

MinElute Handbook. Sample & Assay Technologies. March 2008

Objectives: Vocabulary:

Genomic DNA Clean & Concentrator Catalog Nos. D4010 & D4011

The Biotechnology Education Company

Introduction. Preparation of Template DNA

UltraClean Soil DNA Isolation Kit

Plant Genomic DNA Extraction using CTAB

Sequencing Guidelines Adapted from ABI BigDye Terminator v3.1 Cycle Sequencing Kit and Roswell Park Cancer Institute Core Laboratory website

EZ Load Molecular Rulers. Catalog Numbers bp bp bp PCR bp kb Precision Mass

Lab 5: DNA Fingerprinting

PyroPhage 3173 DNA Polymerase, Exonuclease Minus (Exo-)

50 g 650 L. *Average yields will vary depending upon a number of factors including type of phage, growth conditions used and developmental stage.

HiPer RT-PCR Teaching Kit

In vitro analysis of pri-mirna processing. by Drosha-DGCR8 complex. (Narry Kim s lab)

DNA: A Person s Ultimate Fingerprint

GENOTYPING ASSAYS AT ZIRC

Wizard SV Gel and PCR Clean-Up System

Protocol v001 Page 1 of 1 AGENCOURT RNACLEAN XP IN VITRO PRODUCED RNA AND CDNA PURIFICATION

UltraClean PCR Clean-Up Kit

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Aurora Forensic Sample Clean-up Protocol

Genolution Pharmaceuticals, Inc. Life Science and Molecular Diagnostic Products

HiPer Ion Exchange Chromatography Teaching Kit

Procedures For DNA Sequencing

MICB ABI PRISM 310 SEQUENCING GUIDE SEQUENCING OF PLASMID DNA

Automated High Throughput Purification of BigDye TM Terminator Fluorescent DNA Sequencing Reactions Using Wizard MagneSil TM Paramagnetic Particles

Genomic DNA Extraction Kit INSTRUCTION MANUAL

Preparing Samples for Sequencing Genomic DNA

ab Hi-Fi cdna Synthesis Kit

FOR REFERENCE PURPOSES

How To Make A Tri Reagent

Running protein gels and detection of proteins

ExpressArt Bacterial H-TR cdna synthesis kit. With extreme selectivity against rrnas

AxyPrep TM Mag PCR Clean-up Protocol

LAB 11 PLASMID DNA MINIPREP

VLLM0421c Medical Microbiology I, practical sessions. Protocol to topic J10

Classic Immunoprecipitation

ABI PRISM BigDye Primer Cycle Sequencing Ready Reaction Kit With AmpliTaq DNA Polymerase, FS

Application Guide... 2

Real-time monitoring of rolling circle amplification using aggregation-induced emission: applications for biological detection

RNA Fragment DeepSeq Library Preparation Protocol

Northern blot analysis for microrna. (Narry Kim s lab)

DNA SPOOLING 1 ISOLATION OF DNA FROM ONION

RAINBOW ELECTROPHORESIS 1 An Introduction to Gel Electrophoresis

RT rxns. RT rxns TRANSCRIPTME Enzyme Mix (1) 40 µl 2 x 50 µl 5 x 40 µl

First Strand cdna Synthesis

GenomeLab Sequencing Chemistry Protocol

SequiTherm EXCEL II DNA Sequencing Kit-LC (for 66-cm gels)

Procedure for RNA isolation from human muscle or fat

Dye-Blob message: Example: Generally, this is due to incomplete excess dye removal of the cycle sequence reaction.

Western Blotting: Mini-gels

Terra PCR Direct Polymerase Mix User Manual

DNA Sequencing. Contents. Introduction. Maxam-Gilbert

The fastest spin-column based procedure for purifying up to 10 mg of ultra-pure endotoxin-free transfection-grade plasmid DNA.

RNA Isolation for Frozen Mouse Livers and Reverse Transcription

DNA Detection. Chapter 13

PCR Optimization. Table of Contents Fall 2012

RevertAid Premium First Strand cdna Synthesis Kit

STRUCTURES OF NUCLEIC ACIDS

Sanger Sequencing. Troubleshooting Guide. Failed sequence

NimbleGen DNA Methylation Microarrays and Services

UltraClean Forensic DNA Isolation Kit (Single Prep Format)

RESTRICTION ENZYME ANALYSIS OF DNA

PNA BRAF Mutation Detection Kit

STA DARD OPERATI G PROCEDURE FOR THE DETECTIO OF AFRICA SWI E FEVER VIRUS (ASFV) BY CO VE TIO AL POLYMERASE CHAI REACTIO (PCR)

DNA Sequencing Setup and Troubleshooting

BigDye Terminator v3.1 Cycle Sequencing Kit. Protocol. DRAFT August 27, :32 pm, A_v3.1Title.fm

MagExtractor -Genome-

DNA Sequence Analysis

How To Get Rid Of Small Dna Fragments

How To Use An Enzymatics Spark Dna Sample Prep Kit For Ion Torrent

A Brief Guide to Interpreting the DNA Sequencing Electropherogram Version 3.0

Denaturing Gradient Gel Electrophoresis (DGGE)

RNA Extraction and Quantification, Reverse Transcription, and Real-time PCR (q-pcr)

Reverse Transcription System

Lab 10: Bacterial Transformation, part 2, DNA plasmid preps, Determining DNA Concentration and Purity

7 Electrophoresis. µ proportional to Q

Optimal Conditions for F(ab ) 2 Antibody Fragment Production from Mouse IgG2a

PowerFecal DNA Isolation Kit

Paper Chromatography: Separation and Identification of Five Metal Cations

User Manual. CelluLyser Lysis and cdna Synthesis Kit. Version 1.4 Oct 2012 From cells to cdna in one tube

Biotechnology Explorer. Planning Guide

ELUTION OF DNA FROM AGAROSE GELS

Transcription:

Electrophoresis, cleaning up on spin-columns, labeling of PCR products and preparation extended products for sequencing PAGE electrophoresis Polyacrylamide gel electrophoresis (PAGE) is used for separating molecules by size (DNA or proteins). Pore size is determined by the ratio of acrylamide and bis-acrylamide concentra-tion. Care must be taken when working with acrylamide, since it is a strong neurotoxin, espe-cially in its powdered form. Polyacrylamide gels can separate DNA that differs by 0.2% in length, well beyond the resolving capabilities of agarose (2%). Another advantage of using polyacrylamide gels is that they can accommodate large amounts of DNA (up to 10 μg) without any loss in resolution. Depending upon the application, TBE gels can be prepared as denaturing or nondenaturing ones. Purification of amplicons Purification of nucleic acids using a specially selected silica membrane is a rapid, conven-ient and economical way to isolate DNA and RNA. The technique does not require time-consuming methods based on old technologies such as: use of extraction methods in the phe-nol-chloroform system, precipitation, or PEG-type polymers. Applied membrane technology allows to avoid problems with the silica particles used often as suspensions. The purification procedure removes primers, nucleotides, enzymes, mineral oils, salts, agarose, ethidium bro-mide, and other impurities from DNA samples. The Clean-Up kit is based on the DNA ability to adsorb to silica surface in the presence of high concentration of chaotropic salts [Fig.1]. Starting up the DNA recovery after enzymatic reaction, the binding solution G which contains chaotropic salt, is added to the reaction mix-ture. At high salt concentrations, sodium cations break hydrogen bonds between the hydro-gen atoms of water and the negatively charged oxygen ions in silica. Sodium serves as a cati-on bridge and interacts with negatively charged oxygen of the phosphate backbone of the DNA molecule.

During the next step the whole sample is loaded onto minicolumn with dedicated silica res-in. The DNA binds to the silica resin, while contaminants (enzymes, salts, short primers,etc.) are passing through the column freely. Leftovers of contaminants are moved away in the washing step. Pure DNA is eluted at low salt buffer or water and can be used in the following experiments without additional purification procedures (e.g. precipitation). DNA Chain Termination Sequencing The chain-terminator method (sometimes referred to as the Sanger method) is more effi-cient and uses fewer toxic chemicals and lower amounts of radioactivity than the method of Maxam and Gilbert. Generally it is method of choice for DNA sequencing. The key principle of the Sanger method was the use of dideoxynucleotides triphosphates (ddntps) as DNA chain termination [Figs 3 and 4]. The classical chain-termination method [Fig. 2.] requires a single-stranded DNA template, a DNA primer, a DNA polymerase, radioactively or fluorescently labeled nucleotides and modified nucleotides that terminate DNA strand elongation. The DNA sample is divided into four separate sequencing reactions, containing all four of the standard deoxynucleotides (datp, dgtp, dctp and dttp) and the DNA polymerase. To each reaction added is only one of the four dideoxynucleotides (ddatp, ddgtp, ddctp, or ddttp) which are the chain-terminating nucleotides, lacking a 3'-OH group required for the formation of a phosphodiester bond between two nucleotides, thus terminating DNA strand extension and providing various DNA fragments of varying length. Dye-terminator sequencing utilizes labelling of the chain terminator ddntps, which per-mits sequencing in a single reaction, rather than four reactions as in the labelled-primer meth-od [Fig. 3]. Dye-terminator sequencing requires each of the four dideoxynucleotide chain terminators to be labelled with different fluorescent dyes (different wavelengths of fluores-cence emission) [Fig. 4]. Owing to its greater expediency and speed, dye-terminator sequenc-ing is now the mainstay in automated sequencing. Its limitations include dye effects due to differences in the incorporation of the dye-labelled chain terminators into the DNA fragment, resulting in unequal peak heights and shapes in the electronic DNA sequence trace chromato-gram after capillary electrophoresis. The dye-terminator sequencing method, along with au-tomated high-throughput DNA sequence analyzers, is now being used for the vast majority of sequencing projects.

Purification of chain terminated fragments The best results are obtained when unincorporated dye terminators are completely removed prior to capillary electrophoresis. Excess dye terminators, primers, proteins in sequencing reactions obscure data in the early part of the sequence and can interfere with basecalling. When unincorporated dye is present in large amount then on sequence will be visible dye blobs. Fig. 4. Example of electropherogram with visible dye blobs This are the most popular methods used for purification: Ethanol/EDTA precipitation Ethanol/EDTA/sodium acetate precipitation Plate or spin column purification Used in this training method is based on precipitation of cycle sequencing reaction products on the surface of especially designed membrane. The addition of Mix Blue reagent to the cycle sequencing reaction mixture enables an easy control of precipitation process. In the next step the binding-washing solution is added and the whole mixture is loaded onto Exterminator spin column. During the short centrifugation step the cycle sequencing products are bound by the spin column membrane while the excess of non-incorporated nucleotide terminators and sequencing primer pass through the membrane. The remaining salts and leftovers of other impurities are removed in the washing step. Subsequently the purified cycle sequencing reaction products are eluted directly by water. Literatura: Brody, J.R., Kern, S.E. (2004) History and principles of conductive media for standard DNA electrophoresis. Anal Biochem. 333(1):1-13 Smith LM, Sanders JZ, Kaiser RJ, et al (1986). "Fluorescence detection in automated DNA sequence analysis". Nature 321 (6071): 674 9 Maxam AM, Gilbert W (1977). "A new method for sequencing DNA". Proc. Natl. Acad. Sci. U.S.A. 74 (2): 560 4. Carter, J.M. and Milton, I.D., (1993) "An inexpensive and simple method for DNA purifications on silica particles", Nucl. Acids Res.21

MATERIALS REAGENTS - EQUIPMENT thermal cycler thermoblock centrifuge vortex primers NucleoSpin Gel and PCR Clean-up kit (Macherey-Nagel) Ex-Terminator (A&A Biotechnology) BigDye Terminator v3.1 Cycle Sequencing Kit 1,5 ml tubes 10x TBE electrophoresis buffer (0,1 M Tris, 83 mm Boric acid, 1 mm EDTA) plates with 10% polyacrylamide gel gelloading buffer (0,25 % Bromophenol blue, 0,25 % Xylene cyanol and 40 % sucrose) vertical electrophoresis apparatus (Bio-Rad Mini Protean II) reagent A (EtOH, CH3COOH) reagent B (AgNO3-0,17 %) reagent C (NaOH - 10%, Formaldehyde CH2O - 2%) PROCEDURE PAGE Electrophoresis 1. Clamp your prepared gels and fill up buffer chambers with electrophoresis buffer 1x TBE. 2. Mix the DNA samples (3,5 µl) with the appropriate amount of gelloading buffer (1µl). 3. Load the mixture into the wells using a micropipette. (It is important not to take too long to complete loading the gel; otherwise, the samples will diffuse from the wells) 4. Connect the electrodes to a power pack, turn on the power, and begin the electrophoresis run (Adjust electric current to 30 ma/gel plate) 5. Run the gel until the marker dyes have migrated the desired distance. Turn off the electric power, disconnect the leads, and discard the electrophoresis buffer from the reservoirs. 6. Detach the glass plates. Lay the glass plates on the bench. Use a spacer or plastic wedge to lift a corner of the glass plate. 7. Put gels into the boxes filled with water. Silver staining 1. Wash the gel in H2O for at least 5 min. 2. Discard water and fill up the box with reagent A for 5 min. 3. Discard solution A and fill up the gel with reagent B for 10min. 4. Next rinse the gel with water 3x for 1 minute. 5. Fill up gel with reagent C and instantly discard it. Repeat this procedure until solution is no longer black. 6. Leave the gel in transparent reagent C until the fragments of DNA are visible. 7. Next fill up the gel with water and interpret results.

Clean up amplicons on spin columns

Use the obtained cleaned fragments to prepare reaction with BigDye. DNA Chain Termination Sequencing Reaction 1. Combine the following component for each reaction in a 0.2 ml tube (add BigDye at the end): Reagent Volume Concentration H 2O 3,75 µl - Sequencing buffer 3,5 µl 5x Primer 0,25 µl 10 µm BigDye Terminator v3.1 Ready Reaction Mix 0,5 µl - Clean PCR produkt 2 µl - 2. Use following primers to specific reaction: (EXI, Left primer), (EXII, Right primer), (Mitochondrial long HVR fragment, Left Primer) 3. Place tubes in a thermal cycler preheated to 95 C and start with proper times and temperature as stated below:

HVR Number of cycle 35 Initial denaturation 95ºC 5min Denaturation 95ºC 30 sec Anneling 58ºC 7 sec Extention 60ºC 4 min Hold 4ºC Purifying of extended products (ExTerminator kit) 1. Add 5 μl of Mix Blue to cycle sequencing reaction mixture. 2. Add 100 μl of bind/wash solution and mix sample by pipetting and load the whole sample onto minicolumn. 3. Spin at 1500 x g for 30 s. (the light blue colour of minicolumn membrane is a result of efficient precipitation of sequencing products.) 4. Apply on minicolumn 400 μl of bind/wash solution. 5. Spin at 6000 x g for 2 min. 6. Transfer the minicolumn to a new 1.5 ml tube 7. Apply precisely onto the membrane (center of dark blue circle) 15 μl of water. 8. Incubate at RT for 2 min. 9. Spin at 6000 x g for 2 min. (Light blue colour of eluted sample confirms proper purification of sample) 10. Dry the sample in thermoblock 55 C. 11. Dissolve dried pallet in 12µl of deionized formamide.