Incorporating V2.3. Product spec >>> > Series ECG - Egg Crate Grilles. > Series ECG45-45 Egg Crate Grilles



Similar documents
Grilles & Diffusers Series LFP Incorporating

Laminar Flow Panel. Type LFP 2/2.4/B/2. Telephone +44(0) Telefax +44(0)

SERIES L. Fineline & Broadline. Linear Strip Grilles GRILLES 12

INDEX. Chapter8. air master. Perforated Ceiling Diffusers

K17.11 DOOR BOLTS K17 DOORS

Plaster In Grilles 1/1.5/B/1. AHP Plaster-in Linear Bar Grille ADMP Plaster-in Linear Diffuser ALSP Plaster-in Linear Slot Diffuser

PLASTIC VOLUME CONTROL DAMPERS OVERVIEW TYPE: GGB

Part H DIFFUSERS section 2 SEPT Publication. Air Diffusers. supply and exhaust ventilation systems. plenum boxes

2013 product line. Grilles Diffusers External Louvres Dampers

WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings

DSRQ - DSRSQ - DSRSQ-THERM

security products metric sizes Redefine your comfort zone.

How To Make A Supply Air Ceiling

Original Assembly Guide

Rollers. from the UK s largest roller manufacturer. Quality Performance Reliability

Lift-off hinge. Rising hinge. Standard hinge. Heavy duty hinge. Parliament hinge. Spring hinge. Double action spring hinge. Concealed mortise hinge...

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

STORAGE DESIGN LIMITED

AIR CONDITIONING PRODUCTS COMPANY

Supply air diffuser ROKA/RPKA

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Industrial Linergy LED

Swirl diffuser VSKA. Product facts. Quick selection. Swirl diffuser VSKA. Connection box ATTB. Product code example:

K17.12 Door closers K17. Doors

Huwilift DUO, Huwilift DUO Forte Seite 4 3. Huwilift MAXI. Huwilift MAXI UP. Huwilift Senso, Huwilift E-Senso Page 4 17

Basic Selection & Proper Application of Overhead Air Distribution Devices

Modular Locomotive System Instruction Manual for HBK8 George Body Kit

SECTION 6. Glass Storefront Doors:

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

Installation Window Building In Details

FIRE DAMPER APPLICATION GUIDE

Integral Kit Instructions

EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

plenum slot diffusers

Hürriyet Mah. Dr. Cemil Bengü Cad. No.27/A Çağlayan / Istanbul

Tel: Sales: STORAGE CABINETS. PREMIERSHIELD anti-bacterial powder coating system. quality products made in the UK

Düz Kanatlý Kare Tavan Anemostad

POWERS Controls No. 4 Pneumatic Damper Actuator

BSK BSK DÜZ KANATLI KARE TAVAN ANEMOSTAD (BSCD) FLAT BLADE SQUARE CEILING DIFFUSER

PB accessories. PB accessories. Labelling option. Order Information B Printed board handle A BZA42727 BZA42724.

Fire Resistant Systems

UNIVERSAL RAILING, STEEL

Compactus Freetrack 2 Compactus mekdrive 2 Compactus Side2Side 2. Mobile Storage Systems. Design Manual

plumbing products guide

Lathe Milling Attachment

Colonnade Security Pipe

IKG Bar Grating: Anchoring

CELO5. User & Installation Manual.

Installation Detailed installation instructions are provided which should be strictly followed.

Partitioning & Ceiling Product Information

SECTION AIR INLETS AND OUTLETS

TARIFF CODE and updates standard

KIRÁLY TRADING KFT H-1151 Budapest Mogyoród útja tel: Clamps Clamping devices

Fire Collars For Plastic Pipe Penetration

19 DYNAmax Free Standing Server C A B I N E T s

DE Frame with C Series Sidelight

19 DYNAmax Free Standing Server C A B I N E T s

Sliding and Folding Door Fittings Sliding Door Accessories

Product Information 19 / 45HU Data-Center-Rack (Cabinet)

The complete range. Shower Hardware Doors & Partitions Balustrades Post Railings Glass Windscreens Glass Canopies

Plaisance 50. Windows and doors. Sapa Building System

Rose Door Handles. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

Saferand easierinstallation

The Plastic Injection Moulders. Furniture Fittings & Tube Inserts

INSTRUCTIONS: LocknCharge Laptop Carts

Important Information for Installer & Homeowner

Weather Resistant Louvres

SHOP NOTES METAL SHAPER FOR YOUR SHOP

Slides and Drawers. The right collection

CDW Systems Ltd Contemporary Doors & Windows

HDA

information information

SERVER ROOM CABINET INSTALLATION CONCEPTS

CLEAR-DIVISIONS CENTERFOLD

B.TECH. (AEROSPACE ENGINEERING) PROGRAMME (BTAE) Term-End Examination December, 2011 BAS-010 : MACHINE DESIGN

Flamco Stainless steel mountings

Installation instruction do88 Intercooler for Volvo S40 / V50 / C30

CI/SfB. (31.59) X NOVEMBER 2003 Coburn Interior Sliding Systems

Owner's Manual & Assembly Instructions

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.

Can you design a frameless shower enclosure that doesn't leak?

TECHNICAL INFORMATION

Nightscape High performance floodlights and spotlights for discharge lamps

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

DÜZ KANATLI KARE TAVAN ANEMOSTAD (BSCD) FLAT BLADE SQUARE CEILING DIFFUSER

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.

and Mounting options NEW Additional Profiles HepcoMotion MCS aluminium frame and machine construction system including MFS fencing system

CLEAR-DIVISIONS VARIOFOLD

INSTALLATION OF A BAY WINDOW

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

Aluminium Standard. Technical Data. Included in delivery

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

Cable Runways & Accessories

GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS PHILLIP STREET, SYDNEY

PART 1 GENERAL 1.1 SECTION INCLUDES

lindab duct suspension & support system Duct suspensions & Support systems

EVEN FOR SMALL QUANTITIES WE GET STARTED RIGHT AWAY...

CEILING SYSTEMS. CI/SfB (35) Xy April [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design

Transcription:

Incorporating V2.3 Product spec >>> > Series ECG - Egg Crate Grilles > Series ECG45-45 Egg Crate Grilles

Grilles Egg crate Recommended for: Wall, ceiling & duct Extract Overview Industry standard extract grille Plastic egg crate core optional Capable of handling huge air volumes, egg crate grilles are perfect as intakes into air handling units, and for areas where high changeover rates are needed, paint booths, restaurant kitchens etc. Free area: Mass/M sq face area: Mass/M sq face area inc OBD: 90% 7.5 kg 15.5 kg Egg crate grille, 37mm bevelled flange, RAL 9010 finish Specifications: Exceptional air volumes Volume control Materials: Construction: Extruded aluminium throughout. Plastic core optional. Aluminium core. Frame held together using punched in steel corners. A 90% free area makes egg crate grilles the most efficient extract terminal available from HVC. This also means large pressure drops and noise levels are avoided, where other grilles may begin to have a detrimental effect on performance. Optional rear mounted volume control dampers enable easy adjutment of airflow. The 12.7mm square hole size also enables adjustment to be done from entirely outside the grille, with a screwdriver or key. Core held in by frame design. Frame: Standard - 37mm bevelled. Optional - See page 6. Core only. Fixings: Standard - None. Optional - See page 5. Sizes: Minimum size single unit 100mm x 50mm. Maximum size single unit 2900mm x 2900mm. Mullions: Central mullion on any unit above 1200mm in any dimension. Finish: Standard - Satin anodised (AA5) frame, Mill aluminium finish core. Optional - Polyester powder coat 2 www.h-v-c.com for live UK stock levels

Series ECG A B C D 30mm flat flange (Opt) Nominal + 30mm 28mm 72mm 30mm A B C D 37mm bevelled flange (Std) Nominal + 45mm 28mm 70mm 37mm 600 x 600 ECG D FH SAA SIZE (Nominal / overall w x h [mm]) SERIES DAMPER Opposed blade... D FRAME TYPE - See page 40 32mm bevelled... 25mm flat...25f Others page 40...[#] FINISH Satin anodised... SAA Powder coat...ral/bs FIXINGS - See page 39 Countersunk face... FH Concealed fixings... CF Goalpost brackets... GB Push in clips... PC Burgess tile... BT CORE TYPE - See page 38 Fixed... Hinged... HC Fully removable... RC www.h-v-c.com 3

Grilles Egg crate 45 Recommended for: Wall, ceiling & duct Extract & supply Overview High capacity extract or supply grille 45 core blocks sight and directs throw A new innovation on the reliable Egg Crate Grille, Series ECG45 grilles use a 45 degree core to bring the same air handling performance as standard Egg Crate Grilles, but add the desirable features of blocking sight from most angles, and giving directional throw capability when used for supply. Free area: Mass/M sq face area: Mass/M sq face area inc OBD: 90% 7.5 kg 15.5 kg Egg crate grille 45, 37mm bevelled flange, RAL 9010 finish Specifications: Exceptional air volumes Volume control Materials: Construction: Extruded aluminium throughout. Aluminium core. Frame held together using punched in steel corners. Core held in by frame design. A 90% free area makes egg crate grilles the most efficient extract terminal available from HVC. This also means large pressure drops and noise levels are avoided, where other grilles may begin to have a detrimental effect on performance. Optional rear mounted volume control dampers enable easy adjutment of airflow. The 12.7mm square hole size also enables adjustment to be done from entirely outside the grille, with a screwdriver or key. Frame: Standard - 37mm bevelled. Optional - See page 6. Core only. Fixings: Standard - None. Optional - See page 5. Sizes: Minimum size single unit 100mm x 50mm. Maximum size single unit 2900mm x 2900mm. Mullions: Central mullion on any unit above 1200mm in any dimension. Finish: Standard - Satin anodised (AA5) frame, Mill aluminium finish core. Optional - Polyester powder coat to any RAL / BS colour. 4 www.h-v-c.com for live UK stock levels

Series ECG45 A B C D 30mm flat flange (Opt) Nominal + 30mm 28mm 72mm 30mm A B C D 37mm bevelled flange (Std) Nominal + 45mm 28mm 70mm 37mm 600 x 600 ECG45 D FH SAA SIZE (Nominal / overall w x h [mm]) SERIES DAMPER Opposed blade... D FRAME TYPE 37mm bevelled... 30mm flat...25f Others page 6.....[#] FINISH Satin anodised... SAA Powder coat...ral/bs FIXINGS Countersunk face... FH Concealed fixings... CF Goalpost brackets... GB Push in clips... PC Burgess tile... BT CORE TYPE Fixed... Hinged... HC Fully removable... RC www.h-v-c.com 5

Grilles Hinged & removable cores Removable cores Enabling the whole core section to be removed allows unsurpassed access to dampers and duct internals, without having to remove the main frame, avoiding unnecessary damage to walls or ceilings. Quarter turn fasteners are the standard removable core fitting. Using a discrete clip on the main frame, and a zinc plated pin held securely by a neoprene washer in the core frame, the fasteners are completey secure when in position, but allow quick and easy core removal when needed. The bracket s slim design means grille depths are unchanged from standard, non removable core models. Wing head pins are available as an alternative to slotted head pints to allow removal by hand if required. Pins and brackets are supplied unpainted. Hinged core As with removable cores, hinged cores use a main and core frame. Zinc plated piano hinge is fitted to the full length of the hinged side, and countersunk cross headed bolts secure the core in it s closed position. Chromed cam fasteners are optional. Grille series Core type SD DD FB ECG NV CB LG LGFR CFLG RGS PSG LFP PPG LCD Hinged core x N/A N/A N/A Removable core x 6 www.h-v-c.com for live UK stock levels

Grilles Fitting options Countersunk fixing holes: Code suffix FH Countersunk fixing holes in the grille frame are the easiest fitting method. Screws in the same finish are supplied with the grille. Concealed fixings: Code suffix CF Consisting of L brackets with threaded ports, one L bracket is fixed into the ductwork or plenum, the other is riveted to the rear of the grille frame. Supplied bolts are then used to hold the grille into the supporting structure. Push-in clip method: Code suffix PC These sprung clips are compressed when the grille is pushed into place. The outward force provided then holds the grille securely in place. This method has the advantage of requiring no drilling or bolting, for maximum ease and causing no damage to walls. This fixing method is not suitable for use in ceilings. Goalpost method: Code suffix GB Normally used on linear slot diffusers, HVC has made this effective fixing method available to a wider range of grilles with the addition of a second bracket. It enables the whole grille to be fully supported by, and removable from the plenum. This method is only suitable for linear grilles with 0 blade, single / double deflection grilles, egg crate grilles, curved blade grilles, and any other grille with the removable or hinged core option specified. www.h-v-c.com 7

Grilles Frame types 1 2 3 4 5 6 7 8 9 10 11 Grille series Frame types SD DD FB ECG NV CB LG LGFR CFLG SDG PSG LFP PPG LCD 1 25mm large flat x x x x STD 2 30mm flat 1 way x x x x 3 NV angle x NV1-3 x 4 32mm small bevelled STD x STD x x STD x x x x 5 32mm large bevelled STD x x STD x x 6 37mm ECG x x x STD x x x x N/A N/A N/A STD x 7 30mm ECG x x x x x x x x 8 Slimline surface mounted x x x NV4 x x x x x 9 Large surface mounted x x x 10 36mm bevelled LG x x x x x x STD x x x x 11 31mm flat LG x x x x x x x x x x 8 www.h-v-c.com for live UK stock levels

Selection data ECG Volume (l/s) 2000 1800 1600 1400 1200 1000 900 800 700 Sound pressure leve (NC) Jet velocity (m/s) Static pressure (Pa) Grille width (mm) 100 150 200 250 Grille height (mm) 100 150 600 500 400 300 50 40 30 20 15 10 8 6 5 4 3 2 150 100 60 40 20 15 10 6 4 2 300 350 400 450 500 200 250 300 200 150 100 90 1.5 1.0 0.75 0.5 0.25 1 0.6 0.4 0.2 0.1 0 600 700 800 900 1000 1100 350 400 450 500 550 600 80 1200 70 60 www.h-v-c.com 9

Ancillaries Plenum boxes Overview Designed to facilitate the fitment of ducting to a grille or diffuser. HVC plenum boxes are available in top or side entry models with one or multiple spigots of any diameter. Fire rated models & acoustically lined variants are also available. Specifications: Materials: Construction: Galvanised steel throughout Brake press formed. Fixings: Flange: Finish: Spot welding on spigots. Sealant used on any joints. Standard - Plenum riveted (or other suitable method) to grille or diffuser on site. Optional - Fixing lugs to suit drop rod ceiling. 12.5mm outturned flange used on everything except type CD and PPD diffusers. Standard - Galvanised steel. Optional - Painted to any RAL / BS colour. Top entry plenum box, uninsulated, with 12.5mm out-turns Top entry: Series TEPB The chart below gives maximum volume in m 3 /s that shown spigot sizes can handle for a given noise level, with neck velocities in m/s. Spigot selection NC Level 25 30 35 40 45 Diameter 2.5m/s 3.0m/s 3.5m/s 4.0m/s 4.5m/s 100 0.019 0.023 0.027 0.031 0.035 125 0.03 0.037 0.043 0.049 0.055 150 0.044 0.053 0.062 0.07 0.079 160 0.05 0.06 0.07 0.08 0.09 175 0.06 0.072 0.084 0.096 0.108 200 0.078 0.094 0.11 0.125 0.14 225 0.1 0.12 0.14 0.16 0.18 250 0.12 0.147 0.17 0.196 0.22 300 0.177 0.212 0.247 0.28 0.32 315 0.195 0.23 0.27 0.31 0.35 350 0.24 0.29 0.33 0.38 0.43 400 0.31 0.38 0.44 0.5 0.56 450 0.4 0.48 0.56 0.64 0.72 500 0.49 0.59 0.68 0.78 0.88 550 0.59 0.71 0.83 0.95 1.07 600 0.7 0.85 0.99 1.13 1.27 Side entry: Series SEPB 10 www.h-v-c.com for live UK stock levels

Series TEPB / SEPB / FRTEPB / FRSEPB Fire rated: Series FRTEPB / FRSEPB Constructed from fully welded 1.22mm thick galvanised steel, and with an integrated S200 fire damper rated for a period of six hours, or an intumescent damper rated at one hour. The spring loaded damper blades of S200 fire dampers also mean that top entry boxes can be made fire rated, aswell as side entry. HVC always recommend consulting the relevant fire authority when installing fire rated HVAC equipment. Side entry: Series FRSEPB Top entry: Series FRTEPB 600 x 600 SEPB 2C 200 F SBD IN-RAL9005 SIZE (Nominal / overall w x h [mm]) SERIES SPIGOT ARRANGEMENT State number reqd n... n Double spigot opposite... 2OP Double spigot corner... 2C SPIGOT SIZE 000... Ø 000 x 000... W x H FURTHER OPTIONS Painted interior... IN-RAL Painted exterior... EX-RAL Insulated interior... IN-INS Insulated exterior... EX-INS SPIGOT DAMPER Single blade damper fitted to all spigots... SBD FLANGE 12.5mm all round If different required state size BOX DEPTH Not needed if Series = SEPB www.h-v-c.com 11

Grilles & diffusers Louvres Supplies Ltd Fire / Fire smoke dampers Volume control dampers All details within this brochure are correct at time of going to print. However HVC s policy is one of continual product development. The right is reserved to alter any details published in this brochure without any prior notice. Any changes will appear on www.h-v-c.com as soon as is practically possible. www.h-v-c.com All information in this brochure is designed to be used for informative purposes only. HVC will not be legally bound by anything contained within this publication, or any other information distributed. All references to companies not part of the HVC group of companies are used with the permission of their respective owners.