Schedule 3(A) Room Air Conditioners



Similar documents
SASO 2663 :2014 ENERGY LABELLING AND MINIMUM ENERGY PERFORMANCE REQUIREMENTS FOR AIR-CONDITIONERS

KINGDOM OF SAUDI ARABIA SAUDI ARABIAN STANDARDS ORGANIZATION SASO. SAUDI STANDARD DRAFT No. 3457/2005

Air Conditioner Cooling Capacity Test AS/NZS :1998

SASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS

We carried out the comparative. Split Air Conditioners. More efficiency for the energy. Comparative Test

Greenhouse and Energy Minimum Standards (Air Conditioners and Heat Pumps) Determination

How To Design A Building In New Delhi

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

L.I ENERGY EFFICIENCY STANDARDS AND LABELLING (NON-DUCTED AIR CONDITIONERS AND SELF-BALLASTED FLUORESCENT LAMPS) REGULATIONS, 2005

Energy Efficiency. Energy Efficient Home Cooling:

ENERGY STAR Program Requirements for Residential Air Source Heat Pump (ASHPs) and Central Air Conditioner Equipment. Partner Commitments.

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Air Conditioners Technical Data

REFRIGERATOR AND AIR-CONDITIONER TESTING IN THE REPUBLIC OF KOREA

Research on the Air Conditioning Water Heater System

AHRI Standard 325 (Formerly ARI Standard 325) 1998 Standard for Ground Water-Source Heat Pumps

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

HVAC Efficiency Definitions

Glossary of Heating, Ventilation and Air Conditioning Terms

How to choose a heat pump and use it wisely

All the best brands all under one roof

Performance Rating of Room Fan- Coils

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Testing methods applicable to refrigeration components and systems

The natural ombination

2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units

Energy Efficiency Standards and Labeling in India

Rating Water-Source Heat Pumps Using ARI Standard 320 and ISO Standard

Lesson 36 Selection Of Air Conditioning Systems

Energy efficient room air conditioners best available technology (BAT)

To All Manufactures / Applicants. Subject: Sequence of the documents to be submitted each time for fresh applications:

Creating Efficient HVAC Systems

Split units TH with hermetic compressors

saving energy in comfort Factsheet Recair Enthalpy

By Tom Brooke PE, CEM

Florida Power & Light Company. Business Heating Ventilation & Air Conditioning ( HVAC ) Program Standards. Effective: November 9, 2015

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

Daikin Altherma hybrid heat pump. The natural combination

Understanding Heating Seasonal Performance Factors for Heat Pumps

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

Yijun Gao, Wei Wu, Zongwei Han, Xianting Li *

RESEARCH HIGHLIGHT. Performance Assessment of a Cold-Climate Air Source Heat Pump

Energy Recovery Ventilation Equipment

Outline of presentation

2010 Duct-Free Splits Line Card

Evaporative Cooling for Residential and Light-Commercial

Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER

How To Buy A Lennox Power System

Dehumidifier D 850E. - Instruction manual version 02

Energy Efficiency Testing for HVAC/R Helping you comply with energy efficiency regulatory programs

FTQ. Daikin Inverter Ducted Heat Pump

COOLING BENCHMARKING STUDY REPORT

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

NIPSCO AIR CONDITIONER (AC) CYCLING PROGRAM. Frequently Asked Questions. 1. Can I really make a difference by participating?

HVAC Systems: Overview

Defining Quality. Building Comfort. Precision. Air Conditioning

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM

HP switch LP switch Discharge thermo Comp. Surface thermo

Heating, Ventilation & Air Conditioning Equipment

HEAVY DUTY STORAGE GAS

Dehumidification Frequently Asked Questions

TWE+TTA TWE+TWA T.R.

Measurement And Application of Performance Characteristics Of A Free Piston Stirling Cooler

Final Report by Air Conditioner Evaluation Standard Subcommittee, Energy Efficiency Standards Subcommittee of the Advisory Committee for Natural

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Incubator with mechanical convection

innovative comfort solutions

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

The HVAC Service Assistant

How to Build a Data Centre Cooling Budget. Ian Cathcart

Air Conditioners. Technical Data. Wall Mounted Unit. RX-JV/GV

Daikin Altherma. hybrid heat pump. The natural combination

Wet Bulb Temperature and Its Impact on Building Performance

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

Commercial Gas Heat Pump - VRF

ARMSTRONG AIR HEAT PUMPS

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

Impacts of Refrigerant Charge on Air Conditioner and Heat Pump Performance

Selection Tips For Air-Conditioning Cooling Systems

WORKING DOCUMENT ON. Possible requirements for air heating products, cooling products and high temperature process chillers TRANSITIONAL METHODS

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

PTAC Selection Guide. Optimize your spend with the right PTAC equipment!

Development and testing of a multi-type air conditioner without using AC inverters

PORTABLE AIR CONDITIONER

Failure code manual. content

BEC 2012 Vs BEC Summary of Major Amendments

IV. Rear Mount System

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

How to choose a heat pump and use it wisely

york air-conditioning products Residential & VRF News 2015

Supply & installation of split air conditioners

Unico Inverter. Unique and efficient.

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

Reducing the Cost of Keeping Office Data Centers Cool

Transcription:

Schedule 3(A) Room Air Conditioners Revision : 1 Date : 21/08/15 1. Scope 1.1 This Standard specifies the energy labeling requirements for single-phase split air conditioners of the vapour compression type for household/ commercial use up to a rated cooling capacity of 11 kw and that fall within the scope of IS1391 Part 2, being manufactured, imported, or sold in India including different type of Air conditioners up to 3 ton capacity and single phase shown in Annexure-I. 1.2 This Standard shall be read in conjunction with IS1391 Part 2 with all amendments 1, as applicable In particular, this voluntary scheme specifies the following: 1. Rated power (input). 2. Rated capacity (output). 3. Energy Efficiency Ratio (EER) for cooling. 4. Star rating. 5. Label validity. 6. The performance criteria for energy labeling. 7. Test report format. 8. Color scheme, Dimensions and manner of display. Exclusions: 1. Air conditioners which are not included within the scope of IS 1391 Part 1 and Part 2, pending the development of a suitable test method. 2. Multi-split systems (i.e., those having more than one indoor unit with an independent control for each indoor unit) 3. Evaporative coolers or any other cooling systems that are not of the vapour compression type. 1.3 Definition Air conditioners that are covered in this schedule are encased assembly or assemblies designed as a unit, primarily for mounting in a window, or through a wall, as a console. It is designed primarily for mounting in window, or through a wall, or as a console. It is designed primarily to provide free delivery of air conditioned air to an enclosed space, room or zone (conditioned space). It includes a prime source of refrigeration for cooling 1 Including amendments made during May 2006 meeting of BIS committee on the subject. 1

and dehumidification and may also include means for ventilating or exhausting air. Where such equipment is provided in more than one assembly, the separated assemblies (split-systems) are to be designed to be used together, and the requirements of rating outlined in this schedule are based on the use of matched assemblies. 2. Schedule of tests 2.1 Method of tests The testing code and procedure for air conditioners shall be as per IS1391 Part 2 with all amendments. Exception to IS 1391 part 2: All tests, including the Energy Consumption and Capacity tests, shall be conducted in Balanced Ambient Calorimeters for the purpose of check and challenge testing. 2.2 Parameters to be tested 2.2.1 Energy Consumption The Energy Consumption test of the air conditioner shall be conducted as per IS 1391 Part 2 with all amendments. 2.2.2 Cooling Capacity The Capacity Rating test of the air conditioner shall be conducted as per IS 1391 Part 2 with all amendments. Note : All standard ratings for equipment in which the condenser and the evaporator are two separate assemblies shall be determined with the maximum length of refrigerant tubing on each line of length specified by the manufacturer or 7.5m, whichever is shorter. Such equipment in which the interconnecting tubing is furnished as an integral part of the unit and not recommended for cutting to length should be tested with the complete length of the tubing furnished. Unless constrained by the design, at least half of the interconnecting tubing shall be exposed to the outdoor conditions. The line diameters, insulation, details of insulation, evacuation and charging shall be in accordance with the manufacturer's published recommendations. 2.3 Test Report The results of tests shall be reported as per Annexure II Section 4 of this Schedule. 3. Tolerance Limit For each unit tested, the measured capacity shall be > 0.95 of the rated value For each unit tested, the measured energy consumption shall be < 1.05 of the rated value 2

For each unit tested, the EER shall be > 0.95 of the tested EER There is no tolerance for Star Rating Band, the average of products tested must be at par or better than the Label threshold 4. Rating Plan Rating plan will be as per Annexure II Section 2 (CALCULATIONS FOR THE ENERGY LABEL) of this schedule. 5. Sampling The samples for the check testing will be picked up by Bureau of Energy Efficiency (BEE) or its designated agency for testing at NABL accredited independent laboratory. Three units of each type shall be picked up for each test. The tests shall be conducted on two of the three units, the third shall be kept as an alternative in case one of the units is damaged or can not be tested properly for any other reason. 6. Qualification Maximum Operating Conditions Test The Maximum Operating Conditions Test shall be conducted as per IS 1391 Part 2 with all amendments. 7. Label Design, manner of display The label design and manner of display will be as per Annexure II - Section 3 (LABEL DESIGN AND MANNER OF DISPLAY) of this schedule. 8. Fees a) Security deposit of INR1,00,000 is required to be paid against the labeling fee for the appliances mentioned in the schedule. b) Registration fee is payable on application for assignment of authority is Rs.1000/- (One thousand only). c) Registration fee is payable on application for renewal of authority to affix labels is Rs. 500/- (Five hundred only). d) Labelling fee for affixation of label on each piece of air conditioners is Rs. 30/- (Thirty only). 3

4

1 Definitions Annexure II to Schedule 3(A) SECTION 1 DEFINITIONS For the purposes of this schedule, the definitions given in IS 1391 Part 2 with all amendments and those below apply. The definitions below take preference over the ones in the above mentioned standards. 1.1. Star Rating The number of stars displayed on the energy label. The available stars are between a minimum of one and a maximum of five shown in one star interval. The star rating is calculated from the Star Rating Band (refer 2.2 of this Annexure) 1.2. Star Rating Band The Star Rating Band is a range of energy efficiency ratio (W/W) which is arrived by calculations (refer 2.2 of this annexure), and is used for determining the number of stars displayed on the energy label. 1.3. Family of models Family of models is the range of models of one particular brand, to which a single set of test reports is applicable and where each of the models has the same relevant physical characteristics, comparative energy consumption, and energy efficiency rating and performance characteristics. The term model is synonymous with family of models. 5

SECTION 2 CALCULATIONS FOR THE ENERGY LABEL 2.1 NUMBER OF TEST AND PROCESSING OF DATA 2.1.1 Number of units required For the purpose of determining the Energy Efficiency Ratio (EER) of a model for labeling, two separate units of the nominated model shall be tested for capacity and energy consumption 2.1.2 Number of tests per unit Each unit shall be tested with sufficient test runs to enable a valid EER to be determined for that unit. This determination shall be documented in a test report containing the test result for all test runs used to derive EER. 2.1.3 Rounding Unless otherwise stated, number shall be rounded and recorded to five significant figures. The values of Capacity (kw), shall be rounded and recorded to three significant figures. The values of Energy Consumption (W) shall be rounded of (< 0.5 to lower whole number and 0.5 to higher whole number) to the nearest whole number. The values of EER (W/W) shall be rounded and recorded to two significant figures. 2.2 STAR RATING The star rating parameters EER shall be obtained from TABLE 2.1 / 2.2 / 2.3/2.4, depending on the year of manufacturing/import/assembling SL. No. Product Manufactured/Imported/Assembled Table to be used 1 From 07 January 2010 to 31 December 2011 2.1 2 From 01 January 2012 to 31 December 2013 2.2 3 From 01 January 2014 to 31 December 2015 2.3 4 From 01 January 2016 to 31 December 2017 2.4 6

TABLE 2.1: Star Rating Band valid from 01 May 2011 to 31 December 2011. EER (W/W) Star Rating Min Max 1 Star * 2.30 2.49 2 Star ** 2.50 2.69 3 Star *** 2.70 2.89 4 Star **** 2.90 3.09 5 Star ***** 3.10 TABLE 2.2: Star Rating Band valid from 01 January 2012 to 31 December 2013. EER (W/W) Star Rating Min Max 1 Star * 2.50 2.69 2 Star ** 2.70 2.89 3 Star *** 2.90 3.09 4 Star **** 3.10 3.29 5 Star ***** 3.30 TABLE 2.3: Star Rating Band valid from 01 January 2014 to 31 December 2015. EER (W/W) Star Rating Min Max 1 Star * 2.70 2.89 2 Star ** 2.90 3.09 3 Star *** 3.10 3.29 4 Star **** 3.30 3.49 5 Star ***** 3.50 TABLE 2.4: Star Rating Band valid from 01 January 2016 to 31 December 2017. EER (W/W) Star Rating Min Max 1 Star * 2.70 2.89 2 Star ** 2.90 3.09 3 Star *** 3.10 3.29 4 Star **** 3.30 3.49 5 Star ***** 3.50 The above equation provides for the value of the various Star Rating Bands for a particular model. The Star Rating chosen for the model will be based on the lower and the upper limits of each Star Rating Band. 7

There is no tolerance for the Star Rating Bands. All tested products must meet the minimum threshold for each Star Rating Band. The scope for manufacturing tolerance and other variations shall be accounted for when determining the Star Rating. 8

SECTION 3 LABEL DESIGN AND MANNER OF DISPLAY 3.1 PLACEMENT All air conditioners must display the label at the point of sale. The label shall be adhered, or attached as a swing tag, on the front of the unit or display front. For units not on display, the label may be attached to the exterior of the packaging. The label may be attached to the unit when the unit is removed from its packaging or the label may be included as a part of the documentation given to the customer/user. 3.2 MATERIAL AND SHAPE The label shall be of durable cardboard, if it is to be attached as a swing tag, or be self adhesive and shall be cut to one of the outlines shown in Figure 3.1 as applicable 3.3 COLOURS The label shall be printed as per the specification given in Figure 3.2 3.4 SAMPLE LABEL An example of a printed energy label for air conditioner is shown in Figure 3.3. The label shall display declared values for the following: 1. Appliance/Type: 2. Brand/Model Name/Number/Year of Manufacturing 3. Rated Capacity (kw) 4. Rated Power (Watts) 5. Rated EER (W/W) 6. Variable Output Compressor (Yes/No) 7. Heat Pump (Yes/No) 9

Figure 3.1: Design Scheme for the Label (Sample). 10

Figure 3.2: Colour Scheme for the Label (Sample). 11

Figure 3.3: Sample Label 12

13

SECTION 4 FORMAT OF TEST RESULTS NOTE: A separate form should be prepared for each unit tested. Airconditioner details Brand: Model name: (if applicable) Model number: (of package unit or indoor unit if split system) Model number: (of outdoor unit if split system) A/C Configuration 1 Air distribution non-ducted A/C Configuration 2 Type Cooling only/heating only/cooling and heating Non-ducted split system indoor unit mounting: Wall-hung/Under ceiling/floor mounted/cassette/floor/ceiling Serial number(s) of unit tested: (of package unit or indoor unit if split system) Serial number(s) of unit tested: (of outdoor unit if split system) Rated voltage: V (of package unit or indoor unit if split system) Rated voltage: V (of outdoor unit if split system) Rated frequency: Rated cooling capacity: Rated effective power input, cooling: Length of the Tubing Test summary Complete a separate copy of this page for each test type, as applicable Date of test: Test officer: Test mode: Cooling only Test type: Cooling capacity/maximum operating condition test/all applicable tests Nominal test condition:, Test room type indoor equipment: Calorimeter/Enthalpy test room Test room type outdoor equipment: Calorimeter/Enthalpy test room/water loop Test Standard: IS 1391 Part 2 Test mode: Cooling/ Supply voltage: V (of package unit or indoor unit if split system) 14

Supply voltage: V (of outdoor unit if split system) Supply frequency: Hz Average current (amps): (Single-phase) Stabilization period (minutes): Test period (minutes): Indoor condition mean dry bulb ( C): Indoor condition maximum variation dry bulb (max min) ( C): Indoor condition mean wet bulb ( C): (where applicable) Indoor condition maximum variation wet bulb (max min) ( C): (where applicable) Indoor Fan speed setting: Average air flow volume (m 3 /hour): (if test by air enthalpy method): Outdoor condition mean dry bulb ( C): Outdoor condition maximum variation dry bulb (max min) ( C): Outdoor condition mean wet bulb ( C): Outdoor condition maximum variation wet bulb (max min) ( C): Reading frequency (minutes): Cooling capacity results Measured sensible cooling capacity (W): Measured latent cooling capacity (W): Measured total cooling capacity (W): Measured effective power input (W): Measured EER cooling (W/W): Maximum Operating Conditions Test results Did the unit pass the Maximum Operating Test 110% of rated Voltage? Yes/No Did the unit pass the Maximum Operating Test 90% of rated Voltage? Yes/No 15