Printing and Publishing Energy Savings Guide



Similar documents
HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

Energy Saving Ideas for Your Box Plant

Energy Efficiency in Industrial HVAC Systems

Data Center. Ultra-Efficient chilled water system optimization. White paper. File No: Date: december 03, 2015 Supersedes: new Date: new

3/29/2012 INTRODUCTION HVAC BASICS

Example Retrocommissioning Measure: Opening Throttled Discharge Valves

ALUMINUM. BestPractices Assessment Case Study. Alcoa North American Extrusions Implements Energy Use Assessments at Multiple Facilities.

Natural Gas Energy Efficiency Opportunities for Commercial & Industrial Customers. Michael Pace Lead Engineer C & I Efficiency Programs

Commissioning - Construction Documents (Page 1 of 6)

Impact of Control System Technologies on Industrial Energy Savings

Xcel Business Customers: Program and Rebate Summary

Energy Efficiency in Steam Systems

Training for Building Technicians: Energy Efficiency & Sustainability (BEST) Program. Seminar Outline & Sample BEST Exam Questions

Compressed Air Systems

Boiler NOx Emissions and Energy Efficiency

Efficiency Options for Thermal & Catalytic Oxidizers

HVAC Processes. Lecture 7

Energy Saving Fact Sheet Boilers


Product Data Bulletin

Ener.co & Viridian Energy & Env. Using Data Loggers to Improve Chilled Water Plant Efficiency. Randy Mead, C.E.M, CMVP

Building Energy Systems. - HVAC: Heating, Distribution -

Action Plan Template HVAC Page 1

Energy Efficiency Tips for Businesses

HEATING, VENTILATION & AIR CONDITIONING

Energy Efficient Operations and Maintenance Strategies for Boilers

How to Reduce Energy Costs in Your Commercial Building

State of the Art Energy Efficient Data Centre Air Conditioning

Large Energy Savings Per Installation VFDs for Large Chillers

The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.

CHAPTER 8 HVAC (Heating, Ventilation, and Air-Conditioning)

Small Business Energy Efficiency and Specialty Equipment

Retrofitting for Optimum HVAC Performance by Greg Jourdan Wenatchee Valley College

Scope of Work. See for resources available

Condensing Boiler Efficiency

Saving energy in your business

Glossary of Heating, Ventilation and Air Conditioning Terms

GAS HEATING IN COMMERCIAL PREMISES

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

B.C. Buildings Corporation. Mandatory Preventive Maintenance Standard. To Meet Section 4.78 of the WCB OH & S Regulation

REAL OPERATING COST SAVINGS FROM RETRO- COMMISSIONING OPPORTUNITIES FOR SAVINGS IN ACADEMIC MEDICAL CENTERS

HEAT RECOVERY FROM CHILLED WATER SYSTEMS. Applications for Heat Reclaim Chillers

Consumers Energy Business Solutions. Commercial and Industrial Energy Efficiency Program April 18, 2013

HVAC System Optimization

The Only GUY To Call. Why are my utility bills so high? What can I do to lower my energy expenses?

Commercial/Office Space

Evaluate, Clean, and Tune Guidance

DIABLO VALLEY COLLEGE CATALOG

Continuous Energy Management at UC San Diego. Anna Levitt, P.E. Assistant Energy Manager June 13, 2013

Center for Energy Education Laboratory

Industrial Green Building Retrofit 101 Opportunities and Challenges. Light Industrial Green Building Retrofits. Why Green Retrofit?

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT

Advanced Energy Design Guide LEED Strategies for Schools. and High Performance Buildings

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Creating Efficient HVAC Systems

In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil

Tips on Saving Energy in Your Business

Steam System Efficiency. Bill Lumsden Leidos Engineering

A Cover HVAC ENERGY EFFICIENT

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

Preventive Maintenance. State Energy Assessment Workshop By: DTE Energy Partnership & Services

Heat Recovery and Compressed Air Systems

Overview of Waste Heat Recovery for Power and Heat

HVAC Systems: Overview

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

Chilled Water HVAC Systems

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP

SAVE MONEY NOW. SAVE ENERGY AND MONEY FOR YEARS TO COME.

Description of Thermal Oxidizers

3. Which of the following are benefits of Energy Management Systems? Energy Management Systems:

Top 10 Energy Efficiency Opportunities

National Grid Your Partner in Energy Solutions

HVAC Checklist - Long Form

Heating, Ventilation and Air Conditioning Rebate Catalog Saving energy for a brighter future

Efficiency on a large scale CFB Steam Boilers

Greenhouse Gas Implications of HVAC Upgrades in Multi-Unit Residential Buildings

steam centre of excellence Steam Boiler System Optimization

A. The Commissioning Authority (CxA) has been contracted or will be contracted directly with the Owner for this project.

Energy Efficiency HOSPITALITY.

ENERGY EFFICIENCY ENERGY EFFICIENCY: Saving Dollars While Clearing the Air

Boiler Blowdown. Boiler Blowdown Benefits. Best Operating Practices for Boiler Blowdown

Drives and motors. A guide to using variable-speed drives and motors in data centres

Mechanical, Plumbing, and Fire Protection Conditions

V. ENERGY SAVINGS IN INDUSTRY

Energy Efficiency Workshops For Commercial Customers

UA-NJ Air Conditioning & Refrigeration Division Training Curriculum

Energy Action Plan 2015

Water Efficiency. Water Management Options. Boilers. for Commercial, Industrial and Institutional Facilities. Boiler Water Impurities

Enclosed Football Stadium Design History and Lessons Learned

ASTACEA4 Inspect complex/central air conditioning systems

Air-Conditioning Buying Guide

Small Business Energy Advantage Giving Small Businesses a Competitive Edge

CT556 Boiler Efficiency Modern Controls for Package Boiler Operations

Bring the fresh in. Dedicated Outside Air Systems

HVAC. Combat rising energy costs

Transcription:

Printing and Publishing Energy Savings Guide Oregon printing and publishing plants face challenges of rising operating costs, environmental and other regulations, outdated equipment and customer demand for improved sustainability. Throughout the state, printing facilities continually look for ways to control costs while enhancing the quality and performance of their products and services. Because printing and drying require significant energy input, energy efficiency offers an expanding opportunity to trim operating costs. Energy Trust of Oregon is dedicated to helping you identify options for continuous energy improvement. We can show you how energy is used in typical heatset and coldset printing operations and can help you understand where to focus your efforts. We ve also compiled a list of next steps for you to review. Talk with your Program Delivery Contractor, PDC, about which of these steps could have the biggest impact on energy savings at your business.

VFDs AND THE AFFINITY LAWS ENERGY USE PROFILE FOR A TYPICAL HEATSET PRINTING OPERATION Percent of Full-Load Flow and Power 100 80 60 40 20 Flow Power 2% PROCESS COOLING 6% LIGHTING 7% AIR COMPRESSORS 9% HVAC 34% MOTOR DRIVES 0 0 20 40 60 80 100 Percent of Full-Load Speed Variable Frequency Drives improve pump and fan efficiency by reducing motor shaft speed to the minimum revolutions per minute, rpm, necessary to satisfy flow requirements. A graph of the affinity laws shows that the flow produced by a pump or fan is directly proportional to shaft speed, while the power requirement for that flow is proportional to shaft speed cubed. For example, at 80 percent of full-load flow, a pump or fan operates at 80 percent of full-load rpm, but uses only 51 percent of full-load power, yielding a steady state energy cost reduction of 49 percent. At 50 percent of full-load flow, the pump or fan operates at 50 percent of full-load rpm, but uses only 13 percent of full-load power, yielding an energy cost savings of 87 percent. 10% THERMAL OXIDIZERS ENERGY USE PROFILE FOR A TYPICAL COLDSET PRINTING OPERATION 9% LIGHTING 11% AIR COMPRESSORS 40% HVAC 32% DRYERS 40% MOTOR DRIVES

COMPRESSED AIR Could the energy efficiency of your compressed air system be improved through set point optimization and strategy improvement? Adjusting compressed air system settings and making changes in how your plant uses compressed air can significantly reduce energy use. These improvements can pay for themselves quickly often in as little as a few weeks. Identify and reduce leaks in the compressed air system. Optimize compressed air system pressure. Every two psi of pressure reduction reduces energy use one percent. Adjust regulators and valves within the compressed air system to optimize flow and reduce pressure drop. These adjustments may allow a reduction in compressed air supply pressure, which decreases energy use. Minimize open blowing of compressed air. Optimizing volume and/or reducing frequency decreases compressed air demand. Eliminate inappropriate use of compressed air in the plant, such as for cleaning or cooling. Use more energy-efficient methods. Identify processes, areas and times that allow one or more compressors to be turned off. Could compressed air capital improvements lead to substantial energy savings? Replacing inefficient equipment with new highefficiency technologies can substantially reduce energy use and produce a quick return on investment. Install Variable Frequency Drives, VFDs, on existing compressors that operate under varying load. VFDs save energy by adjusting the compressor speed to fit system demand. Invest in new compressors with VFDs. Typical simple payback of one to four years. Consider installing a blower that produces low-pressure, high-volume airflow to replace less-efficient compressed air in processes that require open blowing. Retrofit controls to load/unload compressor operation in place of existing inlet modulation control systems. Install a master control and monitoring system to sequence and maintain the optimum combination of compressors based on demand. Use small, dedicated compressors to provide compressed air for the dry-fire suppression system. Add controls and valves to reduce nozzle airflow as the process allows. Upgrade inefficient compressed air dryers to higher efficiency systems. Reduce or eliminate the use of oversized compressed air components by installing equipment appropriate for the enduse requirements. Install a dedicated compressor for the Thermal Oxidizer to better optimize system pressure. Upgrade compressed air piping. Piping strategies that are more free flowing provide better system performance and energy efficiency. Reduce or eliminate the runtime of standby compressors that operate during non-production periods. Use a manual switch to provide timed use of the standby compressor for maintenance purposes. LIGHTING Could lighting upgrades yield significant energy savings? Upgrading old or inefficient lighting to high-efficiency technology cuts energy use and often provides a higher quality of light. Use occupancy sensors to control lights in spaces with intermittent use. Occupancy sensors can reduce lighting energy use by as much as 90 percent in seldom-used areas. Replace less efficient fluorescent lighting with high-efficiency linear fluorescent technology. Fluorescent lighting options include energy-efficient T8 task lighting and T5 high-bay lighting. Reduce the number of lamps in overlit areas. Upgrade existing High Intensity Discharge lighting to newer, more energy-efficient technologies to save energy and improve visibility. The switch from Metal Halide or Sodium Vapor to T5 or T8 fluorescent lighting could reduce lighting energy use by up to 50 percent, while improving color rendering. Consider installing LED lighting as an energy-efficient replacement for other less-efficient technologies. LEDs combine ultra-high efficiency with excellent performance and long life in an increasingly affordable package. LEDs also produce little heat, which decreases the plant s cooling load. Use engineered nozzles for compressed air blowing. Upgrading to air-entraining nozzles reduces the volume of compressed air compared to conventional nozzles or open blowing.

SCRAP COLLECTION Could systems that remove materials from the production area be improved to reduce energy use? Removal of scrap from printing and publishing processes can be highly energy intensive. Scrap collection systems can be optimized to provide high-quality scrap collection with the smallest energy input possible. Rebalance air-handling systems to improve duct flow and reduce energy use for fans that move materials from the production area to the collection area. Improving flow also can reduce buildup of materials in ducts. Optimize duct velocity while maintaining proper movement of scrap to collection areas. Add controls to fan systems that serve equipment used intermittently. When equipment is idle, fan systems may be turned off. Install VFDs and controls on system fans to match fan speed to the needs of the scrap collection system. Install VFDs and controls on bag house and cyclone fans to modulate fan speed to fit system demand. Upgrade active cleaning technology in the bag house. Upgrade mechanical cleaning systems that use shakers to clean filter media or reverse air-cleaning systems to pulsejet cleaning systems to reduce energy use. Use low-pressure drop filters in the bag house to reduce fan energy. CHILLER Is there an opportunity to improve the efficiency of your chilled water system through low-cost operations and maintenance improvements? Changes to the set points of the chilled water system do not typically require a large investment of time or capital. Optimize the chilled water temperature set point while providing proper water temperature to support production processes. Typical simple payback of several weeks to one year. Reduce pump pressure in the chilled water loop. Typical simple payback as short as one month. Clean cooling tower coils and chiller tubes regularly. Eliminate inappropriate use of chilled water for low-intensity cooling processes that could be accomplished with municipal water. Adjust controls to stop pumping cooling water when presses are not operating. Typical simple payback as short as one month. Are there opportunities to save energy through capital improvement to your chilled water system? Capital improvements to the chilled water system may be necessary to replace aging equipment. Investment in new energy-efficient equipment can dramatically decrease the cost of supplying chilled water for plant operation. Add VFDs to cooling towers to match the speed of cooling tower fans to the needs of the chiller. Typical simple payback of one to five years. Consider using chiller staging controls on systems that have multiple chillers to take advantage of greater part-load efficiencies while providing similar cooling characteristics. Optimize chilled water pumping by adding VFDs, which match pump speed to momentary demand. Install a water-side economizer to take advantage of freecooling, which allows the cooling tower to use ambient air to help chill water. Typical simple payback of one to four years. Consider installing an oversized cooling tower to take further advantage of free-cooling. Replace existing chillers with high-efficiency models to reduce chilled water system energy use by up to 50 percent, while reducing maintenance costs and improving system function. BOILER Could your boiler be operating more efficiently? Hot water and steam system efficiency can be improved through low-cost operations and maintenance measures, as well as through capital upgrades. Routine maintenance is often all that is required to reduce boiler system energy use. Optimize the temperature of the hot water system to fit production needs. Operating with water that is hotter than process requirements reduces system efficiency. Avoid using steam for tasks such as heating process water. Look for more efficient ways to accomplish the job. Identify and replace steam traps that leak dry steam. Optimize combustion efficiency by adjusting excess air. Typical simple payback as short as two weeks. Install sensors and controls to optimize excess air for dynamic fuel conditions. Add a condensing economizer to the boiler stack to take advantage of flue heat that is exhausted and wasted. Typical simple payback of two to five years. Improve boiler and piping insulation to reduce system heat loss.

Install a heat exchanger to recover heat from flash steam and use it to preheat boiler makeup water. Upgrade burner controls for better burner management and increased efficiency. Upgrade the burner for more efficient combustion. Burner upgrades can have a simple payback as short as one year depending on the capabilities of existing burner controls. Replace inefficient boilers with high- efficiency models, which also can improve the function of the boiler system. Replace a single inefficient boiler with multiple smaller condensing boilers. Use controls to bring boilers online to match heating loads, while reducing inefficiency of part-load operation that exists with larger boilers. OXIDIZER SYSTEMS Are there opportunities to improve the energy efficiency of VOC removal? Energy used for VOC elimination can be reduced or reclaimed to improve energy efficiency. Add secondary heat exchangers to recapture heat from existing oxidizers for use in other plant processes. Typical simple payback as short as one year. Update controls to optimize oxidizer operation based on system demand. Replace existing inefficient oxidizers with high-efficiency oxidizer systems. Typical simple payback as short as two years. HVAC Is your HVAC system functioning properly? HVAC systems that are not operating properly because of deferred maintenance or mechanical malfunction reduce occupant comfort as well as energy efficiency. Tune up demand controlled ventilation to tailor ventilation to meet occupancy levels. Install programmable thermostats to reduce unnecessary energy use during unoccupied hours and to maintain comfortable conditions when workers are present. Repair economizers and calibrate set points to take advantage of free-cooling opportunities. Typical simple payback of between two weeks and one year. Add VFDs to supply and return fans that serve rooftop units to match fan speed to system demand. Add controls that allow a reset of supply air temperature based on ambient air temperature. Adjust existing controls to optimize supply temperature based on outdoor temperature. Add communicating controllers to adjust static pressure reset based on sensor feedback from system zones. Typical simple payback as short as one year. Consider heating individual stations as needed with direct-fired radiant heaters. PROCESS HEAT RECOVERY Could process heat that is lost to the environment be reclaimed for use within the facility? Heated air or water used during production is often exhausted as waste heat. Capturing and reusing waste heat offers the opportunity to reduce energy use. Add air-to-air heat exchangers to recover heat from air that is used in drying processes. Heated air may be used as a preheat input for oxidizer or drying processes. Typical simple payback as short as one year. Recover excess steam from the production process and return it to the boiler before the steam condenses. Use preheated water from presses as an input for boilers. ENERGY TRUST INCENTIVES MAY REDUCE PAYBACK PERIODS LISTED IN THIS GUIDE BY AS MUCH AS 50 PERCENT ON CAPITAL UPGRADES. MOTORS AND CONTROLS Are the motors that operate throughout your plant operating as efficiently as possible? Several energy-saving strategies could be applicable to motors that use more energy than they should. Adjust existing motor control systems to minimize the amount of energy used for normal operation. Small adjustments to control systems could lead to significant energy savings. Add VFDs and associated controls so motor speed matches process needs. During periods of reduced demand, the rpm and energy use of the motor can be reduced. Rebuild worn motors to an efficiency similar to the original specifications. Green rewinds are a cost effective way to boost energy efficiency. Replace existing pneumatic or hydraulic motors with highefficiency electric motors if process needs allow a change in motor technology.

ENERGY PLAYS A CENTRAL ROLE IN PRINTING AND PUBLISHING. Energy Trust can help your facility take control of your energy costs and reduce the impact of energy on your bottom line. Energy Trust provides cash incentives and technical services to help your plant improve energy efficiency and reduce operating costs. Our PDCs are highly skilled industrial energy experts who understand different types of printing and publishing systems, what will work in your facility and how to make the most of energy-saving opportunities. Energy Trust PDCs are located throughout Oregon and can work closely with your personnel to achieve your goals. + Discover how to continuously improve your energy performance. Talk with your PDC, or call Energy Trust directly at 1.866.202.0576 or visit www.energytrust.org/industrial-and-ag. Energy Trust of Oregon 421 SW Oak St., Suite 300, Portland, OR 97204 1.866.202.0576 energytrust.org Energy Trust of Oregon is an independent nonprofit organization dedicated to helping utility customers benefit from saving energy and generating renewable power. Our services, cash incentives and energy solutions have helped participating customers of Portland General Electric, Pacific Power, NW Natural and Cascade Natural Gas save on energy costs. Our work helps keep energy costs as low as possible, creates jobs and builds a sustainable energy future. Printed on recycled paper that contains post-consumer waste. 4/16