ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4



Similar documents
To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Connecting the DG-102S VoIP Gateway to your network

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

Debugging Network Communications. 1 Check the Network Cabling

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Voice Over Internet Protocol (VoIP) Configuration

Chapter 3 Management. Remote Management

1 Serial RS232 to Ethernet Adapter Installation Guide

3.5 EXTERNAL NETWORK HDD. User s Manual

Configuring the CyberData VoIP 4-Port Zone Controller with Audio Out

Configuring CyberData VoIP Ceiling Speakers

Ithaca itherm, POSjet & BANKjet Printers Ethernet Adapters Setup Guide

Chapter 4 Management. Viewing the Activity Log

4 Networking Generators

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

EDGE FX Network configuration

Honeywell Internet Connection Module

User Manual. Thermo Scientific Orion

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T PIN6 T PIN7 R+ PIN8 R-

Chapter 1 Installing the Gateway

SecureLinx Spider Duo Quick Start Guide

enervista UR Setup Software Quick Connect Instructions:

Installation and Operation Guide

Allworx OfficeSafe Operations Guide Release 6.0

Allworx Installation Course

Quick Installation Guide. Overview. GULFSIP ATA-G1S Quick Installation Guide

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks

T3 Mux M13 Multiplexer

Configuring NXT Hardware with Mercury Inside into Doors.NET TM Application Note

Operating Instructions

How To Check If Your Router Is Working Properly On A Nr854T Router (Wnr854) On A Pc Or Mac) On Your Computer Or Ipad (Netbook) On An Ipad Or Ipa (Networking

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

MAX T1/E1. Quick Start Guide. VoIP Gateway. Version 1.0

Deployment Guide: Transparent Mode

DIRECT INTERNET DATA. User s Guide

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

SATO Network Interface Card Configuration Instructions

MDM Mass Configuration Tool User s Manual

PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400

Setting up VPN Access for Remote Diagnostics Support

GV-Data Capture V3 Series User's Manual

Section 5: Connecting the Laser to Your Computer

SOHO 6 Wireless Installation Procedure Windows 95/98/ME with Internet Explorer 5.x & 6.0

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

Shield Pro. Quick Start Guide

Operating Instructions

Section 5: Installing the Print Driver

Servicom G.R.I.P. Enabling Global Push-to-Talk over BGAN and Fleet Broadband Version

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

Setting up Digi Connect Wi-SP or Digi ConnectPort TS W Devices On a Secured Wireless Network for use with Veriteq viewlinc

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

Plena Voice Alarm System Firmware update

How To Set Up A Gxp280 Ip Phone On A Cell Phone On Your Computer Or Ip Phone (Siphone) On A Sim Sim Sim Or Ipro (Cell Phone) On Your Ipro Or Ipo (Cellphone) On

Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.

Ethernet Connection Setup for CCU

Talk2M ewon Internet Connection How To

SDN INSTRUCTIONS 07/10, Ver 1.2. Somfy Digital Network (SDN) Installation and Programming

5330 IP Phone Quick Reference User Guide

Prestige 2002 Series. VoIP Analog Telephone Adaptor. Quick Start Guide

RC2000 Web Server User s Manual RCI P/N: FP-SER-ETH-SERVR1

BiPAC 7404V series. VoIP/(802.11g) ADSL2+ (VPN) Firewall Router. Quick Start Guide

Dominion KX II-101-V2

This techno knowledge paper can help you if: You need to setup a WAN connection between a Patton Router and a NetGuardian.

TELECOM HF VHF UHF over IP

E-Mon Communication Gateway Utility Instructions for BACnet/mstp

SCS3205/4805 Quick Start Guide

SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade

How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline

Web Power Switch III User s Guide Revision LPC-3

Quick Installation Guide. Live! Titanium

IP SERIAL DEVICE SERVER

GXP line SIP Enterprise Phone Quick Installation Guide

Centurion C4 Transfer Guide using C4 File Transfer Utility

Chapter 6 Using Network Monitoring Tools

Modbus RTU (RS-485) TCP/IP (Ethernet)

DVG-2101SP VoIP Telephone Adapter

NXT Controller Manual IP Assignment in WAN Environments Application Note

Maintaining the Content Server

NETVIGATOR Wireless Modem Setup Guide. (TG789Pvn)

FINS Gateway For OMRON PLCs

Ethernet Port Quick Start Manual

Ethernet Radio Configuration Guide

N300 WiFi Range Extender WN2000RPT User Manual

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

Ultra Thin Client TC-401 TC-402. Users s Guide

Model 288B Charge Plate Graphing Software Operators Guide

ivms-4200 Client Software Quick Start Guide V1.02

DCS DCS 6000 Digital Conference System Firmware Upgrade & Feature License Key Manual. Upgrade Manual. Digital Conference System

Inter-Tel IP Phone Quick Reference Guide

Applies to: F1PG200ENau Belkin Analogue Telephone Adapter (ATA) Firmware release notes

How To Check If Your Router Is Working Properly

ReadMe File. Installing the Unified Messaging Application for

Prestige 623R-T. Quick Start Guide. ADSL Dual-link Router. Version 3.40

CPEi 800/825 Series. User Manual. * Please see the Introduction Section

Device Installer User Guide

UPS Network Interface. Quick InstallationGuide

BEC 6200WZL. 4G/LTE Cellular Broadband Router. Quick Start Guide

Transcription:

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4 1 PURPOSE:... 1 2 CPM-4/CPM-2 COMPATIBILITY... 2 2.1 NETWORK CABLES... 2 2.2 FACTORY DEFAULT SETTINGS... 2 2.3 CHANGING THE RS-232 SERIAL PORT BAUD RATE... 2 2.3.1 Changing the Serial Port Baud Rate... 3 2.3.2 Changing the Chassis Configuration Setting... 4 2.4 REMOTE CONTROL VIA THE ACU CONTROLLER... 5 3 CPM-4 EXTENDED FEATURES AND CONFIGURATION OVERVIEW:... 5 3.1 INFORMATION... 6 3.2 CONFIGURATION... 7 3.2.1 Configuration Screen Field Descriptions:... 8 3.3 VOIP CONNECTION MANAGEMENT:... 11 3.4 CONNECTION STATUS:... 11 3.5 MODULE NAMES:... 12 4 RESTORING FACTORY DEFAULTS:... 13 5 ADDITIONAL FEATURES WITH THE REV 2.06 (AND HIGHER) SOFTWARE... 15 5.1 CHASSIS BAUD RATE...15 5.2 AUTO-RESTORE OF STORED CONNECTIONS AT POWER UP... 16 6 SOFTWARE UPDATES:... 17 1 Purpose: The CPM-2 module is being replaced by the New & Improved CPM-4 Module. This new module is functionally equivalent with the CPM-2, but has a number of new features. Chief among them are that it has Ethernet connectivity built in, and the ability to upgrade the firmware in the field. With the CPM-4 installed, the ACU-1000 (or ACU-T) can be connected directly to an IP-Based network for remote control by the ACU Controller program, or a number of ACU Controllers. Previously, a Raytheon ETS-1 unit was required to perform this function. A related improvement is an increased maximum Baud Rate, from 9600 to 115,200. The CPM-4 may also be controlled by a single computer either by an RS-232 serial control connection (as was done with the CPM-2) or by a direct Ethernet connection using a standard CAT5 cable with RJ45 connectors at each end. If Ethernet connectivity is chosen the CPM-4 will allow multiple computers running ACU Controller software to control the ACU-1000 simultaneously. Refer to the ACU Controller software manual for information on remotely controlling the ACU-1000. This addendum explains how to use the CPM-4 module in place of the CPM-2 to provide the same features as the CPM-2, and also how to connect the CPM-4 to a network for remote control. Subsequent addenda will explain how to make use of the new features of the CPM-4. ACU-1000 Operations Manual Page 1 of 18 2720-961204 Rev. E

2 CPM-4/CPM-2 Compatibility The CPM-4 is a plug in replacement for the CPM-2, fully compatible with existing ACU-1000 systems. The CPM-2 used a combination of DIP switches and Non-Volatile memory to set and store various system configuration parameters. The CPM-4 uses Non-Volatile memory only. Configuration parameters that were set using DIP switches in the CPM-2 are now set by connecting the CPM-4 to a network and using a browser to make changes from a menu. 2.1 Network Cables A pair of CAT5 cables is included in the ACU-1000 accessory kit to assist in the setup & use of the new module. The proper type for connection directly between a computer s Ethernet port and the module s front panel RJ-45 jack for browsing or system control is a CAT5 crossover cable (typically red in color, P/N 0314-000024). A standard CAT5 network patch cable (P/N 0313-070000) is the proper interface from a network to the module s RJ-45 jack. These are standard CAT5 network cables; cables in varying lengths are widely available. 2.2 Factory Default Settings For the most part the CPM-4 factory default settings match those of the CPM-2. CPM-4 modules that are installed in a system at the factory are set to match the requirements of that particular system. For example, if the ACU-1000 chassis is sold as part of an expanded (dual chassis) system, the CPM-4 will be pre-configured to either Master or Expansion mode. Table 1 CPM-2, CPM-4 Factory Defaults CPM-2 Dipswitch SW1 Position(s) CPM-2 Default Switch Setting CPM-2 Default Operation CPM-4 Default Operation 1,2 On, On 9600 Baud 115.2 K Baud 3 On Remote Enabled Remote Enabled 4 Off No Serial Sync Char. No Serial Sync Char. 6,7 Off, Off Single Chassis Single Chassis 8 Off Normal Operation Normal Operation 2.3 Changing the RS-232 Serial Port Baud Rate In most cases the factory defaults for the CPM-4 are the same as the CPM-2. The exception is the ACU-1000 RS-232 serial port baud rate. The default for the CPM-4 is 115.2K Baud. Note: if ACU Controller software version 4.0 or later is being used there is no need to change the CPM-4 baud rate. The ACU Controller software can be set to 115.2K baud, which is the default for the CPM-4. But if an earlier version of ACU Controller software is being used then the user must change the baud rate of the CPM-4 to 9600 as outlined here. In systems where only the RS-232 serial port on the rear panel of the ACU-1000 is being used it may be necessary to change the Baud rate. This can be done directly from the ACU-1000 serial port without having to connect the CPM-4 to a network via Ethernet. See Section 5. ACU-1000 Operations Manual Page 2 of 18 2720-961204 Rev. E

2.3.1 Changing the Serial Port Baud Rate If it is necessary to change the CPM-4 serial port baud rate to something other than 115.2K baud, then the user must use a computer with a terminal program such as MTTY or Hyperterminal (included with Windows) to change the serial port configuration. These examples show the use of MTTY. 1. Connect to the ACU-1000 serial port at 115200 baud. 2. Enter the command *CONFIG* and press Enter. 3. The ACU should return with OK. 4. Enter the desired baud rate using the BAUD command. The example below changes the baud rate to 9600. Valid baud rates are 300, 1200,2400, 4800, 9600, 19200, 38400, 57600, and 115200. To set the baud rate to 9600 type BAUD 9600 and press Enter. 5. The ACU will show the new baud rate setting. 6. Enter the command SAVE and press Enter. 7. The ACU will reboot at the new baud rate. Figure 1 Reconfiguring the ACU Serial Port Baud Rate ACU-1000 Operations Manual Page 3 of 18 2720-961203 Rev. E

2.3.2 Changing the Chassis Configuration Setting If the CPM-4 is being installed in an Expanded system (a system with more than one chassis) it may be necessary to change the CPM-4 chassis configuration. The CPM-4 chassis configuration may be changed by using a computer with a terminal program such as MTTY or Hyperterminal. The chassis configuration will either be Single (a single chassis), Master (the Master chassis in a two chassis system) or Expanded (the Expansion chassis in a two chassis system). 1. Connect to the ACU-1000 serial port using a terminal program. 2. Enter the command *CONFIG*. 3. The ACU should return with OK. 4. Enter the desired configuration using the CHASSIS command. The example below changes the chassis configuration to Single. Valid configurations are SINGLE, MASTER and EXPANSION. 5. The ACU will show the new chassis configuration setting. 6. Enter the command SAVE 7. The ACU will reboot. Figure 2 Chassis Configuration Setup ACU-1000 Operations Manual Page 4 of 18 2720-961204 Rev. E

2.4 Remote Control Via The ACU Controller The ACU Controller software treats the CPM-4 exactly as it does the CPM-2. The user attaches the serial port of the computer to the serial port of the ACU-1000 and selects the proper serial port in the ACU Controller software. In the case of network control the ACU Controller treats the CPM-4 exactly as it does a CPM-2/ETS-1 combination, and provides remote control of the unit across an IP network. When configuring ACU Controller for network control the user should enter the IP address and port number of the CPM-4 in the ACU Controller network settings in the Connect menu. The default IP address of the CPM-4, as shipped from the factory, is 192.168.1.200, and the control port is 23. Directions for changing these settings are included below. 3 CPM-4 Extended Features and Configuration Overview: The CPM-4 is a functional superset of the CPM-2, in that it will perform all the classic CPM- 2 functions in an ACU-1000 (or ACU-T), and also contains additional, extended features beyond that of the CPM-2. Most of the extended functions of the CPM-4 revolve around its ability to be connected to a network via Ethernet. When connected to a network, the CPM-4 can provide a network connection for the ACU Controller program that functions identically to a CPM-2/ETS-1 combination. The CPM-4 also has a handset connection on the front panel that can be used to provide a VoIP link to the system. This feature will be covered in a subsequent addendum. This document will address how to use the Ethernet Network connection in the CPM-4 to manage system configuration settings, as well as to make any changes necessary to control the ACU-1000 or ACU-T using the ACU Controller software. The CPM-4 is equipped with a standard Ethernet RJ-45 jack on the front panel. The network connection to the CPM-4 is similar to that of a Raytheon ETS-1 or NXU-2. Configuration is accomplished via a PC / Browser / Ethernet web access. As shipped from the factory, the default configuration of the CPM-4 is to behave identically to a CPM-2. The only system default setting that is different from the CPM-2 is the RS-232 serial port Baud rate. The maximum rate on the CPM-2 serial port was 9600 Baud. The CPM-4 is capable of running up to 115.2K Baud and is configured from the factory to run at this speed. To change the CPM-4 system configuration settings, the user must connect the CPM-4 to the user s Ethernet LAN via the front panel RJ-45 Ethernet connector, via a straight Ethernet cable to a switch or router which is also connected to a PC with network access to the same switch or router. Alternatively the user may connect the Ethernet port of the CPM-4 directly to the computer s Ethernet port via an Ethernet crossover cable. The user must browse (using a web browser like Internet Explorer ) to the IP address of the CPM-4. The default address of the CPM-4 as shipped from the factory is 192.168.1.200. This IP address may be changed to comply with the user s network setting. ACU-1000 Operations Manual Page 5 of 18 2720-961203 Rev. E

3.1 Information Upon successfully browsing to the CPM-4, a screen similar to Figure 3 will appear. This page contains a summary of the current CPM-4 operating status and configuration. Items in the top section are relevant to system configuration while the items in the lower section pertain to VOIP operation. This addendum will address all configuration options other than those related to the CPM-4 s VoIP capability. Figure 3 The Information Screen To modify any of the CPM-4 operating parameters, select the Configuration link that appears at the top of the page. The Configuration Screen will appear see Figure 4 on the next page. ACU-1000 Operations Manual Page 6 of 18 2720-961204 Rev. E

3.2 Configuration Figure 4 The Configuration Screen Configuration changes to the CPM-4 are made either by selecting a field and entering text, or by making a selection from pull down boxes. Each of these fields and its options are described in the next section. Note: For any operational changes to take effect, you must SAVE CHANGES via the Save Changes button. This button may be viewed by scrolling down to the bottom of the screen. ACU-1000 Operations Manual Page 7 of 18 2720-961203 Rev. E

3.2.1 Configuration Screen Field Descriptions: My IP Address: The user may enter numeric text (0-255 decimal) into each of the four fields that define the unique Internet Protocol address of the unit. Note: upon saving the changes, the user will need to browse to the new address to continue configuration. Subnet Mask: The user may enter numeric text (0-255 decimal) into each of the four fields that define the unique Internet Protocol mask of the unit. Note: upon saving the changes, the user will need to browse to the new address to continue configuration. IP Gateway: The user may enter numeric text (0-255 decimal) into each of the four fields that define the gateway address that the unit will use for resolving external network accesses. Remote IP: The user may enter numeric text (0-255 decimal) into each of the four fields that define the unique Internet Protocol address of the remote VoIP unit that is paired with this unit. When the CPM-4 is set up as a client, this is where the server s IP address is entered. THIS OPTION RELATE TO VoIP CAPABILITY. See note on page 11. Baud Rate: The pull down menu allows the user to configure the baud rate for the RS-232 serial port located on the rear panel of the ACU-1000. Nine baud rates are available: 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200. Serial Port Data Bits: The pull down menu allows the user to configure the number of data bits for the serial port. Two choices are available: 7 or 8 bits. The ACU Controller serial mode uses 8 bits. Stop Bits: The pull down menu allows the user to configure the number of stop bits for the serial port. Two choices are available: 1 or 2 bits. The ACU Controller serial mode uses 1 bit. Parity: The pull down menu allows the user to configure the parity for the serial port. Three choices are available: even, odd, or none. The ACU Controller serial mode uses none. Chassis Configuration: The pull down menu allows the ACU-1000 chassis configuration to be set to one of the following: Single, for a single chassis. Master, for a multiple chassis system where this is the main chassis. Expanded, for a multiple chassis system where this is the Expansion chassis. ACU-1000 Operations Manual Page 8 of 18 2720-961204 Rev. E

Connection Configuration: The ACU-1000 can be configured to automatically restore the module connections to the user programmed preset configuration upon power-up. Auto Restore, puts the module connections in the user programmed configuration on power-up. No Restore, leaves all modules unconnected on power-up. Remote Control: This pull down menu allows the ACU-1000 RS-232 serial port on the rear panel to be Enabled or Disabled. CPM-4 Name: The user may enter text in this field that identifies this CPM-4. The name should uniquely identify this unit, from all others on the network. This name will appear on the WAIS Controller to identify this site. Serial Sync. Char: This pull down menu is used to Enable or Disable the RS-232 remote control synchronizing character feature. The ACU Controller serial mode uses disable. Chassis Reset Data: The user may enter a 2-digit number in this field that will be used by the chassis reset (system reset) command that is available to remote DTMF users. The System Reset Feature allows users in the field with DTMF capability (and the proper code) to reset the ACU-1000 to its initial power-up state. This means all current connections will be lost, and the unit will return to any connections stored last by the * 3 6 command. In order to prevent any inadvertent or unauthorized use of this powerful feature, the System Reset Feature can only be used after first being enabled by entering a code other than 00 as the Chassis reset data field of the CPM-4 Configuration Screen (or via the HSP-2 keypad). DSP-2 or PSTN-1 users must then enter this code in order to implement this feature. The ACU-1000 factory default for this feature is disabled. To enable System Reset capability, enter any number other than 0 0 in the Chassis Reset Data Field. The feature is now enabled, and n n is the system reset code. If a DSP-2, RDI-1, or PSTN-1 user (who is currently connected to the system) enters the DTMF command * 9 0 n n, the system will be reset. If * 9 0 and any digits other than the system reset code are entered, the system will not be reset. To disable this feature, enter 0 0 in this field. This feature may also be enabled or disabled by the HSP-2 keypad. See the ACU-1000 Operations Manual for details. ACU-1000 Operations Manual Page 9 of 18 2720-961203 Rev. E

Note: The remaining menu options are related to the VoIP capability of the CPM-4, which will be covered in detail in a subsequent addendum. They are included now only maintain a complete listing. VoIP Port: The user may enter numeric text in this field (1-65535) defining which port to use for the VoIP traffic. Unit is a: The pull down menu allows the user to choose either server or client mode. VOIP operation requires pairing of clients and servers. Command Port: The user may enter numeric text in this field (1-65535) defining which port to use for the remote control traffic. Remote Port: The user may enter numeric text in this field (1-65535) defining which port to use when connecting to its paired unit for VOIP traffic. Voice Compression: The pull down menu allows the user to configure the voice compression (vocoder) that is used for VoIP audio traffic. Five choices are available: GSM at 13Kbps, ADPCM at 16Kbps, ADPCM at 24Kbps, ADPCM at 32Kbps, and PCM at 64Kbps. If the unit is a server, adaptation to the incoming client vocoder is automatically selected to match the client request. VOX Hang time (ms): The pull down menu allows the user to configure the VOX hangtime in milliseconds. Five hangtimes are available: 500ms, 1000ms, 2000ms, 3000ms, and 4000ms. COR Inhibit Time (ms): The pull down menu allows the user to configure the COR inhibit time. Six options are available: 0ms, 500ms, 1000ms, 2000ms, 3000ms, 4000ms. COR Sense: The pull down menu allows the user to configure the COR sense. Three options are available: active low, active high, and VOX. Duplex: The pull down menu allows the user to configure the VoIP channel for either full or half duplex operation. ACU-1000 Operations Manual Page 10 of 18 2720-961204 Rev. E

Communications Mode: The pull down menu allows the user to configure for either normal, broadcast, connectionless, or multicast modes of VoIP communications. Except for special applications this setting should be left as normal. Client Autoconnect: The CPM-4 can be configured to automatically attempt to establish connection with a given Server if the CPM-4 is configured as a Client and a valid IP address has been entered for the Server. 3.3 VoIP Connection Management: Client VoIP sessions may be managed by browsing to the VoIP Connection Management link at the top of any of the unit s web pages. This feature will be detailed in a subsequent addendum. 3.4 Connection Status: VOIP session status may be monitored by browsing to the Connection Status link. Again, this feature will be detailed in a subsequent addendum. ACU-1000 Operations Manual Page 11 of 18 2720-961203 Rev. E

3.5 Module Names: The CPM-4 has the ability to store and retrieve user-defined names for each of the modules installed in the chassis. The module names may be programmed by browsing to the Module Names link at the top of the web pages, and then typing in the name alongside the associated module extension number. Note: These module names are only needed when using the ACU- 1000 in a WAIS (Wide Area Interoperability System.) See the WAIS Controller manual for details. These names will show up on the WAIS Controller screen. Note: Module 0 corresponds with the HSP module of an ACU-T, single Chassis ACU-1000 or Master ACU-1000 of a dual chassis system. Numbers 1 through 12 are associated with the unit s interface module extension numbers. For dual chassis systems, Module 25 is the Expansion Chassis HSP module, while numbers 13 through 24 correspond with this chassis interface extensions. (See Figure 5). Figure 5 The Module Names Screen ACU-1000 Operations Manual Page 12 of 18 2720-961204 Rev. E

4 Restoring Factory Defaults: In rare circumstances, there may be the need to completely restore the CPM-4 to the original configuration that was established when the module was manufactured. The procedure for doing this follows. Equipment Required: 1. Extender Card (supplied in the ACU-1000 Accessory Kit). 2. ACU-1000 (ACU-T) Procedure: 1. Power down the ACU-1000. 2. Remove the CPM-4 from the rack. 3. Install the extender card into the now empty slot. 4. Install the CPM-4 into the extender card. 5. Configure the Restore Factory Defaults jumper J16 [left to center] 6. Power up the ACU-1000. 7. Wait 15 seconds. (The LED s will sequence ) 8. Power off the ACU-1000. 9. Remove the CPM-4 from the extender card. 10. Remove the extender card from the ACU-1000. 11. Re-install the bridging block on jumper J16- [right to center]. 12. Install the CPM-4 back into the ACU-1000. 13. Finished. J16 RESTORE NORM... 321 Ethernet Connector CPM-4 ACU-1000 Operations Manual Page 13 of 18 2720-961203 Rev. E

Results: The completion of the above procedure will re-establish the original factory configuration to the CPM-4. In summary, they are shown in Figure 6. Figure 6 Restored Factory Defaults ACU-1000 Operations Manual Page 14 of 18 2720-961204 Rev. E

5 Additional Features With The Rev 2.06 (and higher) Software Version 2.06 (released 10 September 2004) of the CPM-4 software introduces two new HSP programming items. These programming items are only available to ACU-1000 or ACU-T systems equipped with the CPM-4 module. 5.1 Chassis Baud Rate Using a Browser program and an Ethernet network interface to the CPM-4 module, the user may program the ACU-1000 Serial Port Baud rate. Version 2.06 adds a new HSP programming item, *54x, that allows the user to make changes to the Serial Port Baud rate via the HSP keypad. This is especially helpful in systems where it s not convenient to program via an Ethernet connection. To program the ACU-1000 chassis Serial Port Baud rate via the HSP keypad: 1. The user enters *99 on the HSP keypad. The ACU will respond with the Programming Mode voice prompt. 2. The user then enters one of the following key press sequences to set the desired Baud rate: *540 300 Baud *541 1200 Baud *542 2400 Baud *543 4800 Baud *544 9600 Baud *545 19200 Baud *546 38400 Baud *547 57600 Baud *548 115200 Baud (factory default Baud rate). 3. The user enters * # (star-pound) on the HSP keypad to exit Programming mode. The ACU will respond with the Saving Configuration voice prompt, followed by the Configuration Saved voice prompt shortly thereafter. ACU-1000 Operations Manual Page 15 of 18 2720-961203 Rev. E

5.2 Auto-Restore of Stored Connections at Power Up Using a Browser program and an Ethernet network interface to the CPM-4 module, the user may program the ACU-1000 to enable or disable the Stored Connections Auto-Restore feature. When this feature is enabled, the ACU-1000 will automatically restore the Module Connections to the user programmed default whenever the ACU power is cycled. These Stored Connections are saved by using the *36 HSP command. See the ACU-1000 manual for more information about the Store Connections feature. Version 2.06 adds a new HSP programming item, *55, which allows the user to program the ACU-1000 to Enable or Disable the Stored Connections feature via the HSP keypad. This is especially helpful in systems where it s not convenient to program via an Ethernet connection. To program the ACU-1000 Auto-restore feature via the HSP keypad: 1. The user enters *99 on the HSP keypad. The ACU will respond with the Programming Mode voice prompt. 2. The user then enters one of the following key press sequences: *550 Auto-restore is disabled (factory default setting). *551 Auto-restore is enabled. 3. The user enters * # (star-pound) on the HSP keypad to exit Programming mode. The ACU will respond with the Saving Configuration voice prompt, followed by the Configuration Saved voice prompt shortly thereafter. ACU-1000 Operations Manual Page 16 of 18 2720-961204 Rev. E

6 Software Updates: The CPM-4 is designed to support software updates in the field. Should it become necessary to install updates to the software, the following process should be followed. Instructions and the update software is available on the website. Equipment Required: 1. PC with Internet network access via a browser (Internet Explorer). 2. Ethernet access via an Ethernet switch (for the CPM-4 connection). 3. Ethernet cable. 4. CPM-4 installed in the ACU-1000 / TRP-1000. 5. CPM-4 software and installation software (available from the website). 6. The IP address of the networked CPM-4. Procedure: 1. Use the PC connected to the Internet to browse to the website. 2. Download the CPM-4 software by right clicking on cpm4_update.zip, and choose save target as. Browse to a local folder on your computer to deposit it, then save. 3. Unzip the files in the zip archive. 4. Connect the CPM-4 to the LAN via the switch and Ethernet cable. 5. Launch the autoupdate software by navigating to the folder where it was unzipped / saved, and double clicking on the file autoupdate.exe. 6. A dialog box similar to the one shown below will appear: 7. Enter the IP address of the CPM-4, the path to cpm4_app.s19 (the update software), and insure that the Reboot when complete checkbox is checked. 8. Click the Update button, and a status bar will appear, showing the update progress. ACU-1000 Operations Manual Page 17 of 18 2720-961203 Rev. E

9. After a short delay (10-15 seconds), the following dialog will appear: the CPM-4 will be reset and restarted with the new software activated. 10. Click OK to close the AutoUpdate dialog. 11. Verify the new version of the software has been loaded correctly by browsing to the IP address of the CPM-4, and validating the Firmware version matches the latest release CPM-4 SW Version (per website). 12. This completes the process for updating the CPM-4 software. If you have any questions not answered by this addendum or need further assistance on the functions or use of the CPM-4, please contact Customer Service at 919-790-1011. Please ask the operator for Technical Assistance. ACU-1000 Operations Manual Page 18 of 18 2720-961204 Rev. E