Basic ACD Planning Agent Skill Group Planner The Agent Skill Group Planner assists in planning the distribution of workload between agent skill groups. Using the information collected from customer requirements you can fill in the Agent group planner and program the 3300 ICP as shown. Name The Name field specifies the name of the agent skill group. The Agent Skill Group name is programmed in the Telephone Directory. Overflow Time ACD The overflow time specifies the maximum length of time that a waiting ACD call remains at this group before overflowing to another agent skill group. The timer range is 0 seconds to 54 minutes. The use of this field is optional. Predictive Overflow Predictive overflow determines whether a newlyqueued call to an agent skill group should be immediately overflowed or sent to the next agent skill group. The average call duration is based on the average agent talk time, including the work timer. If the system predicts that a call will not be answered before the overflow timer expires, the system places the call in overflow before the timer expires. 8-13
3300 ICP Installation and Maintenance Course Part 2 Interflow Time The system performs a load calculation when each new call arrives at an agent skill group, or when the status of an agent changes. If the system predicts that a call will not be answered before the timer expires, the system forces an immediate overflow. 1st Threshold The 1st Threshold field specifies the time period for the first callwaiting threshold. If calls are waiting beyond this time period, the LED symbol beside the Generic and Specific Group Alert keys on the Mitel phone changes. 2nd Threshold The 2nd Threshold field specifies the time period for the second call-waiting threshold. If calls are waiting beyond this second time period, the LED symbol beside the Generic and Specific Group Alert keys on the Mitel phone changes again. Alert Device The Alert Device is a preprogrammed Specific Group Alert key typically programmed on the supervisor s set. 8-14 ACD.doc
ACD Path Planner ACD The ACD Path Planner assists in planning the distribution of workload between agent skill groups. Using the information collected from customer requirements you can fill in the ACD Path planner to conceptually understand what is required to program the 3300 ICP. Path Directory Number The Path Directory Number field specifies the path access code used by the system to route calls into the ACD Path. This field is similar to a hunt group number in the system. Path Name The Path Name is the telephone directory name for the Path Directory Number. Priority If there is an agent skill group serving two or more paths, the path with the highest priority will be served by an agent first. The range of values a path can have are 1 to 64 with 1 being the highest priority. Path Reporting The path reporting number is a mandatory, field that specifies the path number of the agent skill group. It is a required field for SMDR. The path reporting number must be a unique 3-digit number in range of 1 to 999. Enter '0' if you don't wish to report a path number. 8-15
3300 ICP Installation and Maintenance Course Part 2 Programming ACD Programming Checklist Assign telephones as ACD sets Program all required feature access codes Create Classes of Service for agents, supervisor sets and RADs Create Generic and Specific Group Alert keys Program RADs and RAD Hunt Groups Program ACD Agents Program Agent Skill Groups Program Dialing Lists (if required) Program ACD Paths Label paths, agent skill groups and agents in the Telephone Directory 8-16 ACD.doc
ACD Assign telephones as ACD sets After planning is complete, the first programming step is to enable DNI or IP multiline sets, to allow an ACD agent to log in. This is done in the Multiline IP or Multiline DNI Set Configuration form. 8-17
3300 ICP Installation and Maintenance Course Part 2 Program all required feature access codes In a call center, often agents do not have assigned seating. When an agent sits at an ACD phone she uses the ACD Agent Login feature access code and logs in with her agent ID. Once logged in, the system associates that phone s extension number with the agent ID. Program all required feature access codes in the Feature Access Code Assignment form. Commonly used codes are: ACD Agent Login and ACD Agent Logout ACD Silent Monitor Make Busy Do Not Disturb 8-18 ACD.doc
ACD Create Classes of Service for agents, supervisor sets and RADs The agent s COS can be used to enable: ACD Silent Monitor - Accept ACD Silent Monitor Notification Enable Do Not Disturb Define the work timer Define the ACD Agent Logout No Answer timer The supervisor s COS should be assigned to the supervisor s set and to their agent ID (if they have one) and can be used to enable: ACD Silent Monitor Allowed Enable Do Not Disturb Define the work timer Define the ACD Agent Logout No Answer timer NOTE SMDR External should be enabled in all Classes of Service. 8-19
3300 ICP Installation and Maintenance Course Part 2 Create Generic and Specific Group Alert keys In order for agents to monitor the queue status for their agent skill group, program a Generic Group Alert key on all ACD agent sets. In order for supervisors to monitor the queue status for all their agent skill groups, program a Specific Group Alert key for each agent skill group for which they are responsible. 8-20 ACD.doc
ACD Program RADs and RAD Hunt Groups Assign the RADs to a RAD group: Typically, the ACD path will play a recording at designated intervals advising the caller of their status within the queue. Recorded Announcement Devices may be used and should be placed in a RAD Hunt Group. RAD groups provide a method whereby a site can be configured with multiple copies of any given recorded message. When an incoming call is connected to a RAD and one of the RAD messages is playing, one of the other RAD messages can be connected sot that no delay is introduced. Create the COS for the RADs: 8-21
3300 ICP Installation and Maintenance Course Part 2 Program ACD Agents ACD Agents are programmed in the Agent ID Assignment form and are assigned a Class of Service and Class of Restriction specific to that agent. The Agent ID name is programmed in the Telephone Directory and the Agent Skill Group number will autopopulate once the agent is assigned to a group. 8-22 ACD.doc
Program Agent Skill Groups Add the agents to agent skill groups in the Agent Skill Group Assignment form according to the ACD plan for the customer. Remember to add the Agent IDs as members to the agent skill group. ACD Set the 1 st and 2 nd Status Threshold timers as required and identify the Alert device.. 8-23
3300 ICP Installation and Maintenance Course Part 2 Program Dialing Lists (if required) Program the Path Interflow Dialing List Assignment form if the callers will be provided with the ability to dial out of queue. 8-24 ACD.doc
ACD Program ACD Paths Program the path in the Path Assignment form. Ensure the ACD programming is tested thoroughly to verify its functionality prior to going live at a customer site. 8-25
3300 ICP Installation and Maintenance Course Part 2 Include the Overflow and Predictive Overflow timers. 8-26 ACD.doc