DDC4002 Automation Station with Operator Function



Similar documents
How To Control A Power Unit On A Powerbomb

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Electronic Control Devices The European Product Catalogue 2007

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Electronic Control Devices The European Product Catalogue 2007

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Digital input modules

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

TX OPEN RS232/485 module

PCS0100en Persy Control Services B.V. Netherlands

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

HMI display Installation Guide

T5000 T000 LCD Digital Fan Coil Thermostat

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

R60 USB to CAN interface Manual (1.5 EN)

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

A-307. Mobile Data Terminal. Android OS Platform Datasheet

Voltage Regulator SPAU 341 C. Product Guide

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Quick Connect. quick - simple - efficient.

DDC3000 Central Control Unit

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

Rack mounted telephone- and leased line modem for industrial applications

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Instruction book IQAN-MDM. Publ. no. HY /UK Edition June, 2007

HERZ-Thermal Actuators

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

AXIS 291 1U Video Server Rack Installation Guide

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Telephone- and leased line modem for industrial applications TD-36

Thyristor-controlled power supplies and battery chargers

FX07 Field Controller

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

PXM20-E. Operator unit DESIGO PX

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

40.3. Control Relays and Timers

Remote Monitoring and REC 501 Control Unit Product Guide

Bullet Camera. Installation Guide. Hangzhou Hikvision Digital Technology Co., Ltd.

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

AXIS T81B22 DC 30W Midspan

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Inwall Room Temperature Unit

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

MINIMAT-EC-Servo Screwdriver Spindles

UniStream CPU-for-Panel

Intersection Preassembled 19-inch Rack

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Waveguide Access Point WGA631. Product Guide

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

SCADA and Monitoring for Solar Energy Plant

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

Application/Connection Examples

ADM1TE 5/30A DIN rail single phase two wire energy meter

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

DCS Data and communication server

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Charge Controller CC611/CC612 Preliminary datasheet

Overview of the Cisco 2500 Series Access Server

In-Sight Hardware specifications

TAC I/NETTM MR-AHU-HP. Application Specific Controller

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Addendum to the Operating Instructions

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Heating Controller. Building Technologies HVAC Products

UniOP epad33 and epad33t

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

70 C 20 C. RS232/422/485 2-to-1 Server. Ethernet RS sub-link. 2-to-1 transparent server. Other Panel. 2-to-1 transparent server. Ethernet.

Climate Ready Control Systems Technical Specifications

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

User manual Rev 1.3 Contents

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

T7560A,B,C Digital Wall Module

Disturbance Recoder SPCR 8C27. Product Guide

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

WEB log. Device connection plans

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

M1000 Process Alarm Monitor

Solid as a Rock etop 300/400

RRV934. Multi-controller. Synco living

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

CompactLogix Power Supplies Specifications

Machine-to-Machine Management System. Datasheet. Models: mport, mport-s, mpower, mpower Mini, mpower Pro, mfi-cs, mfi-ds, mfi-ths, mfi-msc, mfi-msw

Installation manual. Generator Paralleling Controller GPC multi-line C

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM.

Temperature & Humidity SMS Alert Controller

Transcription:

Issue 2014-04-16 Datasheet 2.60-10.202-01-EN utomation Station with Operator Function pplication Color touchscreen with BCnet communication Standalone station with operator function for closed-loop and open-loop control, optimizing and monitoring functions High-quality backlit color display in accordance with industrial standards Built-in touchscreen for intuitive, user-defined operation via plant structures which can be individually created Customizable plain text for every parameter Direct connection of the input and output signals 4 DDC closed-loop control plants for heating and ventilation, can be expanded with software objects PLC functions, free and as fixed macros (hardware objects) Software objects for increasing energy efficiency and energy optimization Weekly and annual schedules, battery-buffered clock Communication Via TCP/IP, Ethernet cable (min. Cat5, 10/100 Mbit) to enable use of the existing infrastructure Built-in remote control via PC with browser without additional software or mobile end devices Native BCnet in accordance with DIN EN ISO 16484-5, BCnet IP and BCnet MS/TP Up to 99 DDC4000 automation stations with bidirectional data exchange ccess to the entire DDC4000 automation system from every connected automation station (remote control) without additional devices 2 buses (CN-based), configurable for switch cabinet bus or fieldbus for connecting up to 63 fieldbus modules (FBM, FBU, FBR or DDC110) or up to 16 switch cabinet bus modules (BMD, BM or SBM) Error message memory, event logging with date and time, incoming and outgoing messages are saved Forwards messages to printers, fax, GSM-SMS and e-mail. Trend value memory for max. 5.000 trend points. Configuration using modern, effective object structure, considerably reducing project planning time. Embedded Linux operating system for proven, stable use Backward-compatible with Kieback&Peter DDC3000 automation system Possible to operate the DDC3000 from the DDC4000 Constant system monitoring of the bus communication and all connected DDC components, bidirectional data exchange possible. Content Page Important Information Regarding Product Safety...2 Technical Data...3 Dimensions...4 Installation Dimensions...5 ccessories (not included in delivery)...6 Connection...6 Installation...8 Mounting...9 Änderungen vorbehalten - Contents subject to change - Sous réserve de modifications - Reservado el derecho a modificación - Wijzigingen voorbehouden - Con riserva di modifiche - Innehåll som skall ändras - Změny vyhrazeny - Zmiany zastrzeżone - Возможны изменения - változtatások jogát fenntartjuk - Kieback&Peter GmbH & Co. KG Tempelhofer Weg 50, 12347 Berlin/Germany Telefon: +49 30 60095-0, Telefax: +49 30 60095-164 www.kieback-peter.de, info@kieback-peter.com

Datasheet 2.60-10.202-01-EN Issue 2014-04-16 Important Information Regarding Product Safety Safety Instructions This data sheet contains information on installing and commissioning the product "". Each person who carries out work on this product must have read and understood this data sheet. If you have any questions that are not resolved by this data sheet, you can obtain further information from the supplier or manufacturer. If the product is not used in accordance with this data sheet, the protection provided will be impaired. pplicable regulations must be observed when installing and using the device. Within the EU, these include regulations regarding occupational safety and accident prevention as well as those from the VDE (ssociation for Electrical, Electronic & Information Technologies). If the device is used in other countries, it is the responsibility of the system installer or operator to comply with local regulations. Mounting, installation and commissioning work on the devices may only be carried out by qualified technicians. Qualified technicians are persons who are familiar with the described product and who can assess given tasks and recognize possible dangers due to technical training, knowledge and experience as well as knowledge of the appropriate regulations. Legend WRNING Indicates a hazard of medium risk which can result in death or severe bodily injury if it is not avoided. CUTION Indicates a hazard of low risk which can result in minor or medium bodily injury if it is not avoided. Indicates a hazard of medium risk which can result in material damage or malfunctions if it is not avoided. NOTE Indicates additional information that can simplify the work with the product for you. Notes on Disposal For disposal, the product is considered waste from electrical and electronic equipment (electronic waste) and must not be disposed of as household waste. Special treatment for specific components may be legally binding or ecologically sensible. The local and currently applicable legislation must be observed. Page 2 / 8

Issue 2014-04-16 Datasheet 2.60-10.202-01-EN Item Controller with operator function Technical Data Nominal voltage For automation station (terminals 1 and 21): C 24 V +/- 10%; 50 Hz..60 Hz; 24 V; 1.0 or DC 24 V +/- 10%; 12 W; 0.5 or DC 12V +/- 10%; 13 W; 1.1 For binary inputs and outputs (terminals 41 and 61): DC 24V +/- 10%; 1.2 W; 0.05 Fuses Time-delay power fuse, 3.15 Inputs and outputs 32 BI/BO configurable, 8 BI (K1 to K8) for pulse counting up to 80 Hz BO: Floating transistor output contact to 0 V = DC 24 V; 50 m 24 I/O configurable Sensor type (I) Value range and unit 0..10 V 0..100% KP10; KP250-50..+150 C Pt100; PT1000-100..+850 C Ni100-50..+150 C Ni1000 (DIN) -50..+150 C Ni1000 (L&G) -50..+150 C NTC 1,8K; NTC 5K -50..+150 C NTC 10K -40..+150 C NTC 20K -50..+150 C NTC 10KPRE -30..+150 C Output (O) DC 0 V to 10 V; 2.5 m Separate auxiliary power (terminal 16) DC 10 V; 20 m for connecting external setting knobs Bus connection Interface Ethernet RJ45 Enables operation of up to 99 DDC4000 automation stations, users can establish worldwide network via active network components, BMS and BCnet client connection, 10/100 Mb/s, TCP/IP 2 CN buses, configurable as fieldbus or switch cabinet bus Fieldbus; F-bus: 63 fieldbus modules (FBM), 2,000 m; 20 kbd, CN Switch cabinet bus; SBM bus: 16 switch cabinet bus modules (SBM or BM/BMD); 200 m; 40 kbd, CN CompactFlash (behind the front panel) for CompactFlash card: Update, backup/restoration Serial RS232 Modem, fax, printer or remote control for DDC3000 automation station RS485 for BCnet MS/TP: 32 devices, 1000 m, up to 115 kbd, routing in accordance with BCnet/IP Page 3 / 8

Datasheet 2.60-10.202-01-EN Issue 2014-04-16 NOTE The RS232 or RS485 interface is activated by means of configuration. Only one of the two interfaces can be used. The default setting is inactive. You can find further information in the DDC4000 project planning documentation Section "SY_Serial" Objects Dimensions Displays Touchscreen with active backlit ¼ VG color active matrix LCD display 14 cm screen size (5.7 inch) Memory 256 MB flash disc; 96 MB SDRM; 1 MB flash PROM (boot) Operating system Embedded Linux Mains failure 7 years, battery-buffered clock module data backup Overvoltage category III Rated impulse withstandvoltage 800 V Level of contamination 2 How It Works Type 1 Degree of protection IP20 mbient temperature 0 C to 50 C mbient humidity During operation: 20% to 80% r.h., non-condensing Out of operation: 5% to 90% r.h., non-condensing Housing 19" plastic short enclosure, quadruple enclosure with base and and extra connections for Ethernet RJ45 and RS232 WxHxD: 202 x 132 x 137 mm Front panel cutout 200.4 mm x 112.0 mm Weight 2.2 kg Marking CE 202,4 14,5 105,5 23,8 110,0 132,5 Page 4 / 8

Issue 2014-04-16 Datasheet 2.60-10.202-01-EN Installation Dimensions 112 +0,5 5,25 Ø 3,0 3,5 x13 5,25 11,3 11,3 200,4 +0,5 ccessories (not included in delivery) Z23 Wall bracket for the DDC3000/DDC4000 automation station Installation note 2.85-10.023-99 contains further information on the installation (included with accessory Z23). Connection +24/12VDC 1 21 0VDC Y 41 K1 K2 K3 K4 K5 K6 K7 K8 K9 K10 K11 K12 K13 K14 K15 K16 +24VDC 0VDC 24VC 0VC 61 61 41 41 61 k1 k17 K17 42 62 k2 k18 K18 43 63 k3 k19 K19 44 64 k4 k20 K20 45 65 k5 k21 K21 46 66 k6 k22 K22 47 67 k7 k23 K23 48 68 k8 k24 K24 49 69 k9 k25 K25 50 70 k10 k26 K26 51 71 k11 k27 K27 52 72 k12 k28 K28 53 73 k13 k29 K29 54 74 k14 k30 K30 55 75 k15 k31 K31 56 76 k16 k32 K32 57 77 58 59 60 78 79 80 (-) B (+) RS485 B1..B24 CN1 B1/Y1 B2/Y2 B3/Y3 B4/Y4 B5/Y5 B6/Y6 B7/Y7 B8/Y8 B9/Y9 B10/Y10 B11/Y11 B12/Y12 +10V/20m 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Y B13/Y13 B14/Y14 B15/Y15 B16/Y16 B17/Y17 B18/Y18 B19//Y19 B20/Y20 B21/Y21 B22/Y22 B23/Y23 B24/Y24 CN2 RJ45 RS232 Page 5 / 8 lways use separate power supply units for supplying power to the controller (terminals 1 and 21 ) and the binary inputs and outputs (terminals 41 and 61 ).

Datasheet 2.60-10.202-01-EN Issue 2014-04-16 Ensure that no third persons can access your data during data transfer. Only use secure solutions when connecting to public networks (VPN). Sensor and actuator connection 0..10VDC ϑ - + 24VC 24V 0V b 0V 24V 0..10V DC 24VC 24V 0V 24V 0V Y K1..K32 k1..k32 41 61 15 24 VDC 0 VDC 2 22 35 B1..B24 21 Y B1..B24 21 Y1..Y24 Y 36 37 B The wiring specified in the wiring diagram (Y, K, ) must be observed. Incorrect wiring may lead to errors in measurement. Page 6 / 8

Issue 2014-04-16 Datasheet 2.60-10.202-01-EN Installation Switching on the power supply of unparameterized products can lead to unforeseen consequences such as malfunctions or material damage. Switch on the power only after the device has been configured by the commissioning technician. CN bus When connecting the CN bus, use a cable with 2 x 2 leads stranded into a pair with plastic insulation and electrostatic shielding with a lead diameter of at least 0.8 mm. Use a stranded pair of wires for the data lines (+ and -) and another free wire for the ground (0). t the end of the CN bus (furthest point from the controller), install a terminating resistor of about 180 ohms between the two data lines (+ and -). The terminating resistor is included with the controller. When using CN bus as a fieldbus, the maximum cable length is 2,000 m. When using CN bus as a switch cabinet bus, the maximum cable length is 200 m. Make sure to observe the line topology for the CN bus. RS485 for BCnet MS/TP When connecting the MS/TP bus, use a cable with 2 x 2 leads stranded into a pair with plastic insulation and electrostatic shielding with a lead diameter of at least 0.8 mm and a characteristic impedance between 100 and 130 ohms. Use a stranded pair of leads for the data lines and another free lead for the ground connection. Observe the polarity of the data lines of the MS/TP. Terminal 78 supplies the inverted signal, it is usually labeled with (-). Terminal 79 supplies the non-inverted signal, it is usually labeled with B (+). Terminal 80 is used for the ground connection. t the start and end of the MS/TP bus only, install a terminating resistor of ideally about 120 ohm between the two data lines. Terminating resistors with 180 ohm that can also be used are included with the automation station. Foreign devices often enable a switchable terminating resistor. Refer to the data sheet or the respective manufacturer s manual for further information. Use bias resistors to maintain the bus idle level at a defined high level and to prevent noise being misinterpreted as a data signal. We recommend that you use network bias resistors on the first and last device on the bus. maximum of 2 devices on the bus may be equipped with network bias resistors. The DDC4000 is fitted with fixed 680 ohm bias resistors. It should therefore be operated as the first or last device on the bus. Foreign devices often offer optionally switchable bias resistors. The maximum possible bus length is 1000 m. maximum of 32 devices can be operated on a bus segment. Observe the line topology for the RS485 bus. Page 7 / 8

Datasheet 2.60-10.202-01-EN Issue 2014-04-16 Mounting WRNING Contact with live parts of electrical domestic installation can cause death due to electric shock. Mounting/removal may only be carried out when power is switched off. Front installation 3,5x13 1 2 3 4 BZ 2,9x16 5 6 19" K rack K 1 M3x11 2 3 4 M3x15 5 6 Page 8 / 8