Critical Care Therapy and Respiratory Care Section



Similar documents
Oxygen Saturation Monitoring by Pulse Oximetry

IntelliVue to go. IntelliVue MX40 wearable patient monitor

1.4.4 Oxyhemoglobin desaturation

Critical Care Therapy and Respiratory Care Section

510 / 511 Cardiorespiratory Monitor Preventative Maintenance Test Procedure

Operating Manual FINGERSIM SET /5.11. for SECULIFE NIBP in Combination with SECULIFE OX1

Pulse Oximetry and the Oxyhemoglobin Dissociation Curve

Instructions to User

Operator s Manual. Nellcor Bedside Respiratory Patient Monitoring System

Capnostream 20p Bedside Capnography Monitor. The only integrated, complete picture of oxygenation and ventilation 1

SpO2 PULSE OXYMETER MD-300

CASMED 740 Vital Signs Monitor

Spirodoc. One Touch Laboratory for respiratory analysis two functional modes: doctor and patient. Spirometer with Touch Screen display

Pulse Oximetry Alarm Reduction Strategy at Boston Medical Center

Self-Install Security System Installation and User Guide

CARESCAPE VC150 Vital Signs Monitor. Connecting intelligence and care.

Nellcor Pulse Oximeters with OxiMax Technology from Covidien

Dash 18X / Dash 18 Data Acquisition Recorder

LabVIEW and Web-Server based Human Body Monitoring System

Dash 8Xe / Dash 8X Data Acquisition Recorder

Spirodoc. 3D Laboratory for respiratory analysis two functional modes: doctor and patient. Four devices in one. Spirometer with Touch Screen display

Critical Care Therapy and Respiratory Care Section

Project 4.2.1: Heart Rate

Pulse Oximeter. Manual

Welch Allyn 1500 Patient Monitor Train the Trainer

Chapter 26. Assisting With Oxygen Needs. Elsevier items and derived items 2014, 2010 by Mosby, an imprint of Elsevier Inc. All rights reserved.

ADC Diagnostix 2100 Fingertip Pulse Oximeter. Directions for use

Policy Name: Patient Monitoring via the Patient SafetyNet (PSN) Monitoring System

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

R Series Quick Reference Guide

Back-UPS Pro 1300/1500 Installation and Operation

Chapter 1 Connecting the Router to the Internet

Automatic Phone-Out Home Monitoring Systems

Oxygenation. Chapter 21. Anatomy and Physiology of Breathing. Anatomy and Physiology of Breathing*

Home Oxygen Therapy Policy and Administration Manual. April Assistive Devices Program Ministry of Health and Long-Term Care

THE NEW GENERATION IN TECHNOLOGY. NI-3103A Alarm Clock w/fm Radio ipod & iphone Docking. Operating Instructions

SimplyGo Quick-start guide

Fax Getting Started Guide

Impact Uni-Vent 754 Portable Ventilator

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

PEBBLE USER MANUAL. MODEL: GMR1888DAB DAB Digital & FM Radio. Hyper-link ALL text to corresponding sections

Stellar 150 Invasive and noninvasive ventilator

HP LaserJet MFP Analog Fax Accessory 300 Fax Guide

Laerdal Patient Monitor Help Page 1 June 14, 2012, Rev E

M O D U L E - 7 E Model CS-Caliprompter Operator s Manual

CONNECTING PHONES, FAXS & DEVICES TO TALKSWITCH

2.4 GHz Dual Handset Cordless Telephone Answering System 2255 with Caller ID/Call Waiting

Connecting to the Internet

Appendix C. Vernier Tutorial

Rad-8. Signal Extraction Pulse Oximeter. Service Manual

Quick Start Guide. From setup to gameplay. Basic Setup. Configuring Your System. Using Game Discs IMPORTANT INFORMATION

Nellcor Portable SpO 2 Patient Monitoring System PM10N V1.05 Software Upgrade. Laura DeNuccio February 2015

DINAMAP PRO Series V2 Monitor. Operation Manual

Residential Gateway (RG) Battery Backup

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

How To Use A Power Supply Unit (Upu)

Rev E October 2004 ZZZ*(6HFXULW\FRP. Part No: R. CareGard. User Guide

Instruction manual for Firstline FCS12000CH

Trilogy accessory guide

Get to Know Your Device 4G LTE BROADBAND ROUTER WITH VOICE

User Guide. Temperature and Humidity Datalogger. Model 42280

Medical Alarm Unit. Instruction Manual. TEST Your Medical Button Weekly. Traditional Installation USING BASIC LANDLINE

Cooling Rewarming QUICK REFERENCE GUIDE. First change Target Temp. Always operate in Automatic Mode. Then change Warming Rate

K9 Heat Alarm Owners Manual HA-1520

Troubleshooting. Before you call for assistance

COLLEGE OF MEDICINE. Sony Portable Video Conference Systems. Operations Manual

MAINTENANCE & TROUBLESHOOTING

Operator s Manual. Model 2500A PalmSAT. Pulse Oximeter with Alarms English

Lothian Guideline for Domiciliary Oxygen Therapy Service for COPD

PA500II Enterprise Mobile Computer

MAINTENANCE & TROUBLESHOOTING

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

SMART SENSOR COLLECTION

Part 2. Copyright 1998 Philips Consumer Communications L.P. All rights reserved. Printed in Mexico. Issue 1AT&T

CFMRI Physiological Monitoring System. Operator s Manual

Optimizing Masimo SET SpO2 Alarm Settings on Select GE Monitors

Impact Uni-Vent 750 Portable Ventilator

HOTRONIX AIR FUSION. Table of Contents. Safety Instructions. Machine View. Touch Screen Guide Operating Instructions.

Communication/Internet Operation Manual

EMMA Emergency Capnometer/ Finger Pulse Oximeter Version 2 Related Documents SOP-Medical and Equipment packs Stuart Daly; Phil Munro

Four-Line Intercom Speakerphone 944

User Guide. BlackBerry Remote Stereo Gateway

Installing Your Vonage Device in Front of an Existing Router for customers with DSL INTERNET SERVICE

TruSat Pulse Oximeter

FiOS Self-Installation guide for ADDING OR EXCHANGING EQUIPMENT

Pocket DAB & FM Radio with Speaker

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Dock-N-Talk U S E R S G U I D E. Forming a New World of Communication. SM

HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP ver.1.0

Scope: Applies to the various anesthesia vaporizers used to deliver a known concentration of vaporized liquid. Sample. Type Interval Time Required

CABLE ONE ALL DIGITAL

TMS TANK MANAGEMENT SYSTEM

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

HP ProDisplay P19A LED Backlit Monitor. User Guide

Puritan Bennett. Achieva Ventilators. with Flow Acceleration and Apnea Back Up. Clinician s Manual

Accuracy and reliability of pulse oximetry in

Transcription:

Critical Care Therapy and Respiratory Care Section Category: Clinical Section: Clinical Monitoring Title: Overnight Pulse Oximetry Policy #: 08 Revised: 03/00 1.0 DESCRIPTION 1.1 Definition 1.1.1 A pulse oximeter is a completely non-invasive device for providing an estimate of arterial oxyhemoglobin saturation (SaO 2 ) by utilizing selected wavelengths of light to determine the saturation of oxyhemoglobin (SpO 2 ). The oximeter's lightweight sensors, designed for ease of use with various types of patients, allow non-invasive optical absorption measurements of pulsing arterial blood. The sensors take measurements by optical means alone. There is no heat source that may burn the patient. The light source consists of two light-emitting diodes operating at minimal power levels. 1.1.2 The pulse oximeter is a portable, bedside monitor that is electrically powered or battery operated. 1.1.3 The pulse oximeter conveys, both audibly and visually, the results of measurements of oxygen saturation and pulse rate; the two digital displays give a continuous readout that updates with each heartbeat. A qualitative indication of the strength of the pulse is represented by either a vertical light bar, known as a perfusion indicator, or a plethysmographic waveform. 1.1.4 The pulse oximeter provides preset or manually set alarms for high and low oxygen saturations and heart rate. 1.1.5 The oximeter will not make a measurement unless the patient's perfusion is adequate to provide the data needed for accuracy. The perfusion indicator, the vertical light bar or plethysmograph, provides an indication of patient perfusion.

1.2 Goal 1.2.1 To monitor, during sleep, both audibly and visually, adequate patient oxygenation and to obtain a report of the trends. Because the pulse and oxygen saturation can be updated with every heartbeat, there is an immediate indication of any hypoxemic event in which the patient desaturates. 1.3 Indications 1.3.1 Any patient who appears hypoxic, secondary to a restrictive or obstructive disorder. 1.3.2 Patients who have low arterial PaO 2 s as indicated by arterial blood gas. 1.3.3 Patients being evaluated for home oxygen and/or home CPAP use. 1.3.4 The need to monitor the adequacy of arterial oxyhemoglobin saturation. 1.4 Hazards 1.4.1 Electrical precautions should be taken as with any electrically powered equipment. DO NOT immerse the pulse oximeters in water or in any liquid solution. 1.4.2 Battery or fuse changes should only be performed by qualified personnel. Only the same type and rating of fuse must be used for replacements to minimize the risk of fire. 1.4.3 Cross-contamination of equipment can occur with reusable sensors if they are not properly disinfected. 1.5 Precautions 1.5.1 The pulse oximeter is calibrated to read arterial hemoglobin oxygen saturation of functional hemoglobin (saturation of hemoglobin functionally available for transporting oxygen to the arteries). Significant levels of dysfunctional hemoglobins such as carboxyhemoblobin or methemoglobin may affect the accuracy of the measurement. 1.5.2 The pulsatile saturation measurements are not reliable if a patient s perfusion is insufficient to supply data.

2.0 EQUIPMENT 1.5.3 Cardiogreen dye and other intravascular dyes may, depending on concentration, affect the accuracy of the measurement. 1.5.4 Patient motion may affect sensor performance. 1.5.5 Lipid infusion can interfere with sensor performance. 2.1 Ohmeda Pulse oximeter 2.2 Ohmeda oxisensor/cable with finger probe 2.3 33.6 Faxmodem 3.0 PROCEDURE (PATIENT SET-UP) 3.1 Verify physician s order for overnight pulse oximeter study 3.2 Plug into 120 Volt AC electrical outlet 3.3 Connect Ohmeda oxisensor/cable with finger probe 3.4 Turn pulse oximeter on (Will do a self-calibration) 3.5 View Main Menu Touch 3.6 Touch Labels use the and -/+ to scroll through, enter the Patient s full name and MR#, touch when done. 3.7 Touch Date verify that the date and time are correct. Use the and -/+ to scroll through and change if needed. Touch when done. 3.8 Touch picture of Waveform 3.9 Apply the finger probe to the finger. The index finger is the recommended site. Wrap the finger probe with colored adbau. 3.10 Set the SpO 2 and Heart Rate Alarms using the alarm buttons ( to the right of the screen). Set alarms according to the physician s orders. 4.0 PROCEDURE (TREND PRINT OUT) 4.1 Connect modem/analog cable to the RS232 connector on the rear of the pulse oximeter

4.2 Plug both the pulse oximeter and faxmodem into 120 Volt AC electrical outlets. 4.3 Plug the telephone cord into a single-line telephone jack. (Will not dial out on a multi-line jack) 4.4 Turn the faxmodem on. 4.5 Turn pulse oximeter on. 4.6 Press the Menu button 4.7 Select Settings, then Mode to choose the trend data (SpO 2 ) to be transmitted. Then select 4.8 Select Modem to display the Modem Status screen. 4.9 Choose Select Data and select the number of hours of data to be transmitted (ALL), then select 4.10 Press Send, select Fax, then enter the phone number for 10D fax machine (00834). 4.11 Then select Send. After you select Send to transmit a fax, some or all of the following messages may be displayed: 4.10.1 Dialing Remote Fax modem is dialing the number 4.10.2 Busy the fax machine is busy. The modem redials the number until the fax machine is no longer busy or until you press Cancel. 4.10.3 Connecting the fax machine has answered the phone 4.10.4 Sending fax the connection process is complete. A bar graph shows the progress of the transmission. The percentage of data transmitted, the number of pages faxed, and the total number of pages to be faxed are shown below the bar graph. The page is sent again if the fax machine reports poor page quality. The bar graph shrinks accordingly. The percentage sent and the page number reference reflect the new status. 4.10.5 Fax Done transmission is complete. The modem disconnects the phone line. Press to display the Send screen. 4.12 Canceling a transmission if you select Cancel while transmitting data, transmission stops, and the modem disconnects the phone line. When you

cancel a fax transmission, the Fax Cancelled message is displayed on the screen and transmitted to the fax machine. Press to return to the Send screen. 4.12 Place trend print-out in the front of the patient s chart by 8 AM, inform the patient s nurse that the study/report is completed.

SIGNATURE: Assistant Section Chief, CCTRCS, CCMD DATE: SIGNATURE: Section Chief, CCTRCS, CCMD DATE: SIGNATURE: Medical Director, CCTRCS, CCMD DATE: (Orig. 3/00)