Instructions to User
|
|
|
- Stella Chase
- 10 years ago
- Views:
Transcription
1 Instructions to User PC-68A Wrist Oximeter is a precision measuring device, please read the manual very carefully before using this device. Failure to follow these instructions may cause measuring abnormality or damage to the oximeter. No part of this manual may be photocopied, reproduced or translated into another language without the prior written consent. Shenzhen Creative Industry Co., Ltd. reserves the right to improve and amend it at any time without prior notice. Version of This Manual: Ver 1.2 Revised date: June 1, 2011 All rights reserved. Notes The contents contained in this manual are subject to I
2 change without prior notice. Information furnished by Creative is believed to be accurate and reliable. However, no responsibility is assumed by us for its use, or any infringements of patents or other rights of third parties that may result from its use. Instructions for Safe Operations Check the device to make sure that there is no visible damage that may affect user s safety or measurement performance with regard to sensors and clips. It is recommended that the device should be inspected minimally once a week. When there is obvious damage, stop using the device. Necessary maintenance must be performed only by qualified service technicians. Users are not permitted to maintain it by themselves. The oximeter cannot be used together with devices not specified in User Manual. Cautions Explosive hazard DO NOT use the oximeter in environment with inflammable gas such as some ignitable anesthetic agents. DO NOT use the oximeter while the testee is under MRI or CT scanning. II
3 Warnings User Manual for Wrist Oximeter An uncomfortable or painful feeling may appear if using the oximeter continuously on the same place for a long time, especially for poor microcirculation patients. It is recommended that the oximeter should not be applied to the same location for longer than 2 hours. If any abnormal condition is found, please change the position of oximeter. DO NOT clip this device on edema or tender tissue. The light (the infrared light is invisible) emitted from the device is harmful to the eyes, so service technician or testee should not stare at the light. The local law must be followed when disposing of the device. Attentions Keep the oximeter away from dust, vibration, corrosive substances, explosive materials, high temperature and moisture. The device should be kept out of the reach of children. If the oximeter gets wet, please stop using it and do not resume operation until it is dry. When it is carried from a cold environment to a warm and humid environment, please do not use it III
4 immediately. User Manual for Wrist Oximeter DO NOT operate the button on the front panel with sharp materials. High temperature or high pressure steam disinfection to the oximeter is not permitted. Refer to related chapter for instructions of cleaning and disinfection. Declaration of Conformity: The manufacturer hereby declares that this device complies with the following standards: IEC ISO 9919 and follows the provisions of the council directive MDD93/42/EEC. IV
5 Table of Contents 1 OVERVIEW Appearance Name and Model Conformation Features Intended Use Key of Symbols BATTERY INSTALLATION OPERATION Measuring Operation Alarm Limit Settings Upload Data Low Battery Indication ADDITIONAL ADVICE FOR OPERATION TECHNICAL SPECIFICATIONS ACCESSORIES REPAIR AND MAINTENANCE Maintenance Cleaning and Disinfecting Instruction TROUBLESHOOTING APPENDIX A Common Knowledge B Wristband Installation and Disassembly V
6 1 Overview 1.1 Appearance 1. LCD screen Figure 1 Front View 2. Set key: shift display modes, confirm the operation etc. 3. Scroll key: move display cursor, modify parameter values etc.
7 Figure 2 Frontal Side View 4. Buzzer 5. Data interface 6. Wristband Underlay 7. SpO 2 probe receptacle 1.2 Name and Model Name: Wrist Oximeter Model: PC-68A Figure 3 Right Side View -2-
8 1.3 Conformation User Manual for Wrist Oximeter It comprises the main unit and SpO 2 probe. 1.4 Features Wrist Oximeter can be used to monitor pulse oxygen saturation (SpO 2) and pulse rate accurately. Simply put your finger into sensor, SpO 2 value and pulse rate value will be displayed on screen and stored in the device. It is lightweight, small in size and easy to carry; Segment LCD display; Automatic starts to measure SpO 2 and Pulse Rate(PR) and display pulse intensity bar graph as well; Numerical value flash alarm function; It is convenient for you to monitor SpO 2 in long-term while sleeping or at other daily activity. Data storage and transmission to PC for viewing and analysis; Smart battery power management with low battery indication; Two AAA batteries can be used for over 50 hours -3-
9 monitoring continuously. 1.5 Intended Use This Wrist Oximeter is intended for measuring the pulse rate and functional oxygen saturation (SpO 2). It is applicable for long-term measurement of adult s SpO 2 and pulse rate in homes and clinics. -4-
10 1.6 Key of Symbols User Manual for Wrist Oximeter Symbols %SpO 2 BPM Descriptions Pulse Oxygen Saturation Pulse rate icon(unit: beats per minute) Low battery voltage Memory full. CE mark Serial number Date of manufacture Authorised representative in the European community Manufacturer (including address and date) With Type BF applied part Warning See User Manual Disposal of this device according to WEEE regulations -5-
11 2 Battery Installation Figure 4 Battery Installation 1. Lift up the cloth covered on the battery cover. Then, use your index finger and middle finger to press against the battery cover. Meanwhile, slide it towards the side with SpO 2 probe (as shown in Figure 4). 2. Refer to Figure 4, insert two AAA size batteries into the battery compartment properly in the right direction. 3. Replace the cover. Remark: After finishing battery installation, the oximeter will automatically power on and display software version number firstly. In order to record data in real time in future, please set the date/time in the oximeter via PC software- Oximeter Data Manager. -6-
12 Please take care when you insert the batteries, as the improper insertion may make the device not work. 3 Operation 3.1 Measuring Operation 1. Insert the external SpO 2 probe connector into SpO 2 probe receptacle properly. Figure 5 Sp0 2 Probe Connection 2. Fix the oximeter on your left wrist as shown in Figure 6 (Refer to Appendix for details); 3. Then, hold the probe with its opening towards your index finger. The probe should be oriented in such a way that the sensor side with a finger tip sign is positioned on the top (Figure 6). -7-
13 Finger tip sign Figure 6 Placement Demonstration 3. Next, insert your index finger into the probe until the fingernail tip rests against the stop at the end of the probe (Figure 7). Adjust the finger to be placed evenly on the middle base of the sensor (make sure the finger is in the right position). If the index finger cannot be positioned correctly, or is not available, other finger can be used. Figure 7-8-
14 Wrong Placement of the Probe: Finger out Not deep enough Figure 8 4. The oximeter will automatically start measurement in 2 seconds. Then the default screen will be displayed (Figure 9). User can read the values from the display screen. Figure 9 Default Screen %SpO 2 : SpO 2 icon; 98 : SpO 2 value; BPM : Pulse rate icon; BPM : pulse rate unit, beats per minute; 78 : Pulse rate value; : Pulse intensity bar graph. Key Operations: Longtime press key: alarm limit setting screen -9-
15 will be displayed, refer to section 3.2 for details; Longtime press key: turn on/off LCD display; 5. Prompt Information During monitoring, if there is no signal to be detected, the short lines will be prompted on the screen instead of the numerical values, as shown in Figure 10. Figure 10 No Signal During measuring, the measured values are recorded every 2 seconds. The length of data record is limited to 30 seconds at least, and the maximal length for one record is also limited to 2 hours. During measuring, if the memory is full or the total number of the records is 256 pieces, the earliest records will be overwritten and the icon will appear on the screen for prompt, as shown in Figure
16 Memory full Figure 11 Memory Full Note: It is suggested that the data shall be uploaded to computer for saving, or the earliest records will be overwritten. 6. Working Mode The measurement will start automatically when the finger is inserted into the soft rubber of the sensor, so the data recording (SpO 2 and PR values) starts simultaneously as well. The display is as shown in Figure 9. During measuring, long time press key to blank the screen (the measurement and data recording are still undergoing.), but long time pressing any key will activate the display for viewing the current -11-
17 measuring information again. If there is no signal to be detected (e.g. finger off) for 20 seconds, the device will be at idle state (i.e. blank screen and standby for measurement). When the device is at idle state, long time pressing any key will activate the LCD display, or once the finger is inserted in the soft rubber of the sensor, the measurement will start and LCD display will be activated as well. 3.2 Alarm Limit Settings SpO 2 Lower Alarm Limit Setting On default display screen(figure 9), longtime press key to enter SpO 2 Lower Limit Setting Screen, as shown in Figure 12A. Figure 12A -12- Figure 12B
18 %SpO 2 Lo : SpO 2 lower alarm limit; 90 : SpO 2 preset value; Key Operations: : selecting cursor; On SpO 2 Lower Limit Setting screen (Figure 12A), press key to move cursor to SpO 2 value (Figure 12B). Then press key to change its value; Short time press key: increase the numerical value single time; Long time press key: increase the numerical value continuously; Next, long time press key to confirm the preset value and exit the setting PR Lower and Higher Alarm Limit Settings On SpO 2 Lower Limit Setting Screen (Figure 10A), when the cursor stays in the upper area, short time press key to shift the screen among PR Lower Limit Setting screen (Figure 11A), PR Higher Limit Setting screen (Figure 12A) and SpO 2 Lower Limit Setting screen (Figure 10A). -13-
19 Figure 11A Figure 11B Lo value; Figure 12A -14- Figure 12B BPM : PR lower alarm limit; 60 : preset Hi BPM : PR higher alarm limit; 120 : preset value; : selecting cursor;
20 Key Operations: User Manual for Wrist Oximeter Short time press key: move the cursor upwards or downwards; Short time press key: increase the numerical value single time; Long time press key: increase the numerical value continuously; Long time press key: confirm the preset value and exit the setting. Note: During measuring if SpO 2 or/and PR values exceed the preset alarm limit, the numerical value exceeded limit will flash. 3.3 Upload Data Before uploading the data to PC, please quit from the menu screen if you are doing the setup. When start uploading, connect the data cable between the device and PC, then do the following operation by the instruction in Oximeter Data Manager User Manual, the data uploading will be activated. If the device and the PC realize communication successfully, the oximeter will display the screen as shown in Figure
21 Figure 13 Data Upload 3.4 Low Battery Indication When occurs on the screen, it indicates battery power is not enough. If you keep on using, the measuring error may be caused, please change batteries in time. -16-
22 4 Additional Advice for Operation The finger should be put in properly and correctly. Avoid shaking finger as possible as you can during measuring; Do not put wet finger directly into sensor. Avoid placing the device on the same limb which is wrapped with a cuff for blood pressure measurement or during venous infusion. Do not let anything block the emitting light from device. Electrosurgical device interference may affect the measuring accuracy. Using enamel or other makeup on the nail may affect the measuring accuracy. If the first reading appears with poor waveform (irregular and not smooth), then the reading is unlikely true, the more stable value is expected by waiting for a while, or a restart is needed when necessary. -17-
23 5 Technical Specifications A. Display mode:segment LCD Screen B. Power supply requirement: 2 x LR03 (AAA) alkaline batteries or Ni-MH rechargeable batteries Supply voltage: 3.0VDC C. Operating current: 40mA D. SpO 2 Parameter Specifications Transducer: dual-wavelength LED Measurement wavelength: Red light: 663 nm, Infrared light: 890 nm. Maximal optical output power: less than 1.5mW maximum average Measuring range: 35~99% Measuring accuracy: Not greater than 3% for SpO 2 range from 70% to 100% *NOTE: Accuracy defined as root-mean-square value of deviation according to ISO E. Pulse Rate Parameter Specifications Measuring range: 30bpm~240bpm Accuracy: ±2bpm or ±2% (whichever is greater) -18-
24 F. Preset alarm limits: SpO 2 alarm: Lower limit: 90% Pulse Rate alarm: Upper limit: 120bpm Lower limit: 50bpm G. Update rate: 6 seconds moving average for SpO 2 and 8 beats average for Pulse Rate readings. H. Record Interval 2 seconds per group (SpO 2 and PR values) I. Performance under low perfusion condition The measurement accuracy still keeps the above specification while the perfusion index is as low as 0.6%. J. Resistance to interference of surrounding light: The difference between the SpO 2 value measured in the condition of indoor natural light and that of darkroom is less than ±1%. K. Resistance to 50Hz /60Hz interference SpO 2 and PR are precise which have been tested by BIO-TEK pulse oximeter simulator. L. Physical feature Dimensions: W 59mm D 49mm H 22mm -19-
25 Net Weight: about 60g (not including batteries) M. Classification The type of protection against electric shock: Internally powered equipment. The degree of protection against electric shock: Type BF applied part. The degree of protection against harmful ingress of liquids: Ordinary equipment without protection against ingress of water. Electro-Magnetic Compatibility: Group I, Class B 6 Accessories A data cable (optional) Oximeter Data Manager software (optional) A wristband A SpO 2 probe Two batteries (AAA) A User Manual Quality Certificate Note: The accessories are subject to change. See the Packing List for detailed items and quantity. -20-
26 7 Repair and Maintenance 7.1 Maintenance The life of this device is 5 years. In order to ensure its long service life, please pay attention to the use of maintenance. Please change the batteries when the low-voltage indicator lightens. Please clean the surface of the device before using. Use cloth with alcohol to wipe the device first, and then let it dry in air or wipe it dry. Please take out the batteries if the oximeter will not be used for a long time. The recommened storage environment of the device: ambient temperature: -20ºC ~60ºC, relative humidity 10%~95%, atmospheric pressure: 50kPa~107.4kPa. The oximeter is calibrated in the factory before sale, there is no need to calibrate it during its life cycle. However, if it is necessary to verify its accuracy routinely, the user can do the verification by means of SpO 2 simulator, or it can be done by the local third party test house. High-pressure sterilization cannot be used on the device. -21-
27 Do not immerse the device in liquid. 7.2 Cleaning and Disinfecting Instruction Surface-clean sensor with a soft gauze by wetting with a solution such as 75% isopropyl alcohol, if low-level disinfection is required, use a 1:10 bleach solution. Then surface-clean with a damp cloth and dry with a piece of cloth. Clean the wristband with soapy water. Please detach the wristband from the oximeter firstly. (Refer to Appendix for detailed disassembly method) Caution: Do not sterilize by irradiation steam, or ethylene oxide. Do not use the sensor if it is damaged. -22-
28 8 Troubleshooting User Manual for Wrist Oximeter Trouble Possible Reason Solution The SpO 2 and Pulse Rate display instable Can not turn on the device Always display No Signal 1. The finger is not placed inside enough. 1. The batteries are drained or almost drained. 2. The batteries are not inserted properly. 3. The device s malfunction. 1. The probe is not connected to the oximeter properly. 2. The finger is not placed well. 3. The probe connector or the probe sensor is broken. 1. Place the finger properly and try again. 1. Change batteries. 2. Reinstall batteries. 3. Please contact the local service center. 1. Connect the probe to the oximeter properly and try again.; 2. Place the finger properly and try again. 3. Please contact the local service center. -23-
29 9 Appendix A Common Knowledge 1 Meaning of SpO 2 User Manual for Wrist Oximeter SpO 2 is the saturation percentage of oxygen in the blood, so called O 2 concentration in the blood; it is defined by the percentage of oxyhemoglobin (HbO 2) in the total hemoglobin of the arterial blood. SpO 2 is an important physiological parameter to reflect the respiration function; it is calculated by the following method: SpO 2 = HbO 2/ (HbO 2 +Hb) 100% HbO 2 are the oxyhemoglobins (oxygenized hemoglobin), Hb are those hemoglobins which release oxygen. 2 Principle of Measurement Based on Lamber-Beer law, the light absorbance of a given substance is directly proportional with its density or concentration. When the light with certain wavelength emits on human tissue, the measured intensity of light after absorption, reflecting and attenuation in tissue can reflect the structure character of the tissue by which the light passes. Due to that oxygenated hemoglobin (HbO 2) and deoxygenated hemoglobin (Hb) have different absorption character in the spectrum range from red to infrared light -24-
30 (600nm~1000nm wavelength), by using these characteristics, SpO 2 can be determined. SpO 2 measured by this oximeter is the functional oxygen saturation -- a percentage of the hemoglobin that can transport oxygen. In contrast, hemoximeters report fractional oxygen saturation a percentage of all measured hemoglobin, including dysfunctional hemoglobin, such as carboxyhemoglobin or metahemoglobin. Clinical application of pulse oximeters: SpO 2 is an important physiological parameter to reflect the respiration and ventilation function, so SpO 2 monitoring used in treatment has become more popular. (For example, such as monitoring patients with serious respiratory disease, patients under anesthesia during operation and premature and neonatal infants) The status of SpO 2 can be determined in timely manner by measurement and will allow finding the hypoxemia patient earlier, thereby preventing or reducing accidental death caused by hypoxia effectively. 3 Factors affecting SpO 2 measuring accuracy (interference reason) Intravascular dyes such as indocyanine green or methylene blue Exposure to excessive illumination, such as surgical lamps, bilirubin lamps, fluorescent lights, infrared heating lamps, or direct sunlight. -25-
31 Vascular dyes or external used color-up product such as nail enamel or color skin care Excessive patient movement Placement of a sensor on an extremity with a blood pressure cuff, arterial catheter, or intravascular line Exposure to the chamber with High pressure oxygen There is an arterial occlusion proximal to the sensor Blood vessel contraction caused by peripheral vessel hyperkinesias or body temperature decreasing 4 Factors causing low SpO 2 Measuring value (pathology reason) Hypoxemia disease, functional lack of HbO 2 Pigmentation or abnormal oxyhemoglobin level Abnormal oxyhemoglobin variation Methemoglobin disease Sulfhemoglobinemia or arterial occlusion exists near sensor Obvious venous pulsations Peripheral arterial pulsation becomes weak Peripheral blood supply is not enough -26-
32 B Wristband Installation and Disassembly Step 1: Fix the wristband on your left wrist(fig.a). Fig. B Wristband underlay Wristband Fig. A Fig.C Step 2: Put the oximeter on the propriate site of the wristband. Then press the oximeter to make the wristband underlay(fig.b) stick to the wristband firmly. Next, follow the Fig.C to fix the oximeter well. Step 3: The process of wristband disassembly is similar to the installation method, but with reverse procedure. Note: Please detach the wristband from the oximeter before cleaning the wristband. -27-
33 -28-
SpO2 PULSE OXYMETER MD-300
MD-300 C MD-300 A MD-300 D MD-300 B MD-300 F MD-300 I MD-300 Z Finger clip ADULT Finger clip PEDIATRIC Soft tip ADULT Wrap ADULT -> PEDIATRIC Wrap PEDIATRIC -> NEONATE Y Type Pulse oxymètre portable MD-300C
Critical Care Therapy and Respiratory Care Section
Critical Care Therapy and Respiratory Care Section Category: Clinical Section: Clinical Monitoring Title: Overnight Pulse Oximetry Policy #: 08 Revised: 03/00 1.0 DESCRIPTION 1.1 Definition 1.1.1 A pulse
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
How To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
Instructions to User
Telefoon: 074-2911110 (klantenservice) Internet: www.medipreventiecentrum.nl Bestel in onze webshop Instructions to User Dear users, thank you very much for purchasing the Pulse Oximeter. This Manual is
MEMO ALARM CLOCK Operating Manual
MEMO ALARM CLOCK Operating Manual INTRODUCTION Congratulations on purchasing this state-of-the-art Alarm clock with radio controlled time. The operation of this product is simple and straightforward and
Ultrasound Technologies. PD1v. vascular pocket doppler. Operating Instructions
Ultrasound Technologies PD1v vascular pocket doppler Operating Instructions Before using your Pocket Doppler for the first time, please read these operating instructions carefully. 1 INTRODUCTION The UltraTec
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
EMMA Emergency Capnometer/ Finger Pulse Oximeter Version 2 Related Documents SOP-Medical and Equipment packs Stuart Daly; Phil Munro
Emergency Medical Retrieval Service (EMRS) www.emrs.scot.nhs.uk Standard Operating Procedure Title EMMA Emergency Capnometer/ Finger Pulse Oximeter Version 2 Related Documents SOP-Medical and Equipment
RomiApex A-15. APEX LOCATOR User Manual
RomiApex A-15 APEX LOCATOR User Manual Table of Contents Introduction..... 2 1. Indications for use... 3 2. Precautions..... 3 3. Adverse Reactions...... 3 4. Package Contents........ 3 5. Getting Started.....
Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of
Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of the blood 7 Procedure to test glucose 7 Procedure to
User s Manual AURORA 1.2K/2.2K
User s Manual AURORA 1.2K/2.2K Uninterruptible Power System Safety CAUTION This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable
Use and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
ADC Diagnostix 2100 Fingertip Pulse Oximeter. Directions for use
ADC Diagnostix 2100 Fingertip Pulse Oximeter Directions for use ADC Fingertip Pulse Oximeter Thank you for purchasing an ADC Diagnostix TM Brand Fingertip Pulse Oximeter. We re proud of the care and quality
Operating Manual FINGERSIM SET 3-349-631-03 1/5.11. for SECULIFE NIBP in Combination with SECULIFE OX1
Operating Manual FINGERSIM SET for SECULIFE NIBP in Combination with SECULIFE OX1 3-349-631-03 1/5.11 CONTENTS 1 GENERAL WARNINGS AND CAUTIONS... 4 2 PURPOSE... 5 3 DESCRIPTION... 6 4 THEORY OF OPERATION...
Model UT33A: OPERATING MANUAL Table of Contents (1)
Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter structure Functional Buttons LCD Display Measurement Operation
RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug. 2011. RIGOL Technologies, Inc.
Quick Guide DS1000CA Series Oscilloscope Aug. 2011 Technologies, Inc. Guaranty and Declaration Copyright 2011 Technologies, Inc. All Rights Reserved. Trademark Information is a registered trademark of
USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018
USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and
TM Advanced Tracking Technologies, Inc. 2003 ATTI All rights reserved
TM Advanced Tracking Technologies, Inc. 2003 ATTI All rights reserved Copyright 2003, Advanced Tracking Technologies, Inc. All rights reserved. No part of this publication may be reproduced or transmitted
User s manual FLIR VP50/VP52 Non-contact AC voltage detector
User s manual FLIR VP50/VP52 Non-contact AC voltage detector User s manual FLIR VP50/VP52 #T559851; r. AD/ 9134/9134; en-us Table of contents 1 Disclaimers... 1 1.1 Copyright... 1 1.2 Quality assurance...
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
XP Series Balances Operation Manual
XP Series Balances Operation Manual North and South America: 6542 Fig Street Arvada, Colorado 84 1-8-321-1135 Tel: 33-431-7255 Fax: 33-423-4831 U.K. and Ireland: Denver House, Sovereign Way Trafalgar Business
CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual
Instruction Manual OPC-LM1-IL Option Card for Encoder of Line Driver Output CAUTION Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual
Pulse Oximeter. Manual
Pulse Oximeter Instruction Manual MD300C318T Copyright Our company owns all rights to this unpublished work and intends to maintain this work as confidential. Our company may also seek to maintain this
Instant Ear Thermometer
INSTRUCTION MANUAL Instant Ear Thermometer Model 18-107-000 Please read this detailed guidebook completely before operating this unit. English Spanish Limited Five-Year Warranty Your Ear Thermometer is
DAB+ / FM Tuner Model: TU-201
DAB+ / FM Tuner Model: TU-201 Instruction Manual www.pulse-audio.co.uk 1 Safety Information The lightning bolt within a triangle is intended to alert the user to the presence of dangerous voltage levels
CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual
Instruction Manual Option Card for Frequency Divider Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual and understand the description
CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI
American Weigh Scales, Inc. CQ-Series Digital Pocket Scale 7 4 1 0. 8 9 5 6 2 3 x = - CALI + CALC MODE M CAL AC CE % TARE OFF ON MC MR CQ-350 (350x0.1g) CQ-500 (500x0.1g) User Manual CQ-Series Manual Thank
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
WRIST PULSE OXIMETER INSTRUCTION MANUAL
INSTRUCTION MANUAL (Non-Medical Equipment) Edition: V1.0W11 Copyright Our company owns all rights to this unpublished work and intends to maintain this work as confidential. Our company may also seek to
RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G
Auto-Levelling Rotary Laser Level RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G 77-496 / 77-429 / 77-439 / 77-497 / 77-427/ 77-441 Please read these instructions before operating the product Auto-Levelling
Getting started with
PART NO. CMA113 MADE IN CHINA 1. Measuring CAT II 2. Max. voltage 250V ~ 3. Max. current 71 Amp Getting started with Electricity consumption monitoring single phase for homes and some smaller light commercial
HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP-2004-12 ver.1.0
HIGH PRECISION BALANCE MWP OWNER S MANUAL MWP-2004-12 ver.1.0 INTRODUCTION------------------------------------------------1 1. INSTALLATION---------------------------------------------------2 Unpacking---------------------------------------------------------------2
Pocket Tach 99 (PT99) Non-Contact Tachometer
CE DECLARATION OF CONFORMITY As Manufacturer: Monarch Instrument Division of Monarch International Inc. 15 Columbia Drive, Amherst NH 03031 USA declares under Monarch s sole responsibility that the product:
Operating Manual Remote Cost Control Monitor
Operating Manual Remote Cost Control Monitor INTRODUCTION: Congratulations on purchasing the Remote Cost Control. This is a state-of-the-art power monitoring socket that is highly accurate and easy to
BEL-AIR WIRELESS THERMO-HYGROMETER Instructions manual Cat. No. 30.3045.IT
BEL-AIR WIRELESS THERMO-HYGROMETER Instructions manual Cat. No. 30.3045.IT Thank you for choosing this wireless thermo-hygrometer from TFA. BEFORE YOU USE IT Please be sure to read the instruction manual
Hygro-Thermometer + InfraRed Thermometer Model RH101
User's Guide Hygro-Thermometer + InfraRed Thermometer Model RH101 Introduction Congratulations on your purchase of the Extech Hygro-Thermometer plus InfraRed Thermometer. This device measures relative
8001782 Owner s Manual
8001782 Digital Infrared Thermometer Owner s Manual Introduction This instrument is a portable, easy to use compact-size digital thermometer with laser sighting designed for one hand operation. The meter
This unit is internally powered equipment; the degree of shock protection is type B.
Table of Contents Chapter1 Safety Guidance... 1 1.1 Safety Precautions... 1 Chapter2 Introduction... 4 2.1 Overview... 4 2.2 Features... 4 Chapter3 Outlook and Configuration... 5 3.1 Front Panel... 6 3.2
CL90i. 77-021 Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser
3 - Beam Self-Leveling Cross Line Laser CL90i 77-01 Please read these instructions before operating the product Self-Leveling GB D F I E PT NL DK SE FIN NO PL GR CZ RU HU SK SI BG RO EE LV LT Contents
Dual Laser InfraRed (IR) Thermometer with Color Alert
User Manual Dual Laser InfraRed (IR) Thermometer with Color Alert MODEL 42509 Introduction Congratulations on your purchase of the Model 42509 IR Thermometer with Color Alert. This Infrared thermometer
Otium Gear S Smart Watch User Guide Please read the manual before use. * For further information, please visit www.otiumobile.com
Otium Gear S Smart Watch User Guide Please read the manual before use. * For further information, please visit www.otiumobile.com 1 About this manual You can use this Gear S as a companion device to some
HOFFRICHTER DATA box
HOFFRICHTER DATA box Operating Instructions Serial Number Each HOFFRICHTER device is provided with a serial number which guarantees the product can be traced back. The serial number is on the type identification
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
SPL 2-00/-01 OPERATION INSTRUCTIONS
SPL 2-00/-01 OPERATION INSTRUCTIONS Powerline Ethernet Adapter 500 Mbps EN Read and keep Operation Instructions SPL 2-00/-01 Safety Notes Do NOT use this product near water, for example, in a wet basement
Automatic Wrist Blood Pressure Monitor with
Instruction Manual Automatic Wrist Blood Pressure Monitor with Model HEM-609 ENGLISH ESPAÑOL CONTENTS Before Using the Monitor Introduction...................................... 3 Important Safety Notes.............................
F O R E R U N N E R 6 1 0. q u i c k s t a r t m a n u a l
F O R E R U N N E R 6 1 0 q u i c k s t a r t m a n u a l Important Information warning Always consult your physician before you begin or modify any exercise program. See the Important Safety and Product
READING DEVICE US-05
436120 ОКП SCIENTIFIC AND PRODUCTION COMPANY «DOZA» READING DEVICE US-05 Operation manual Table of contents 1 Reader description and operartion... 3 1.1 Purpose of the device. 3 1.2 Technical specifications
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
A. FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENT
A. FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, Pursuant to Part 15 the FCC rules. These limits are
UT202A Operating Manual. Contents
Title Contents Page Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Functional Buttons and auto power off Display Symbols
Magic Wand Portable Scanner
Magic Wand Portable Scanner PDS-ST470-VP User Manual Table of Contents 1. Key Features... 3 2. Functional Parts... 3 3. Explanation of the Status Icons... 5 4. Using the Scanner... 5 4.1. Charging up the
Introduction. Intended use. Contraindications. General warnings and cautions. Patient Instructions WARNING CAUTION. English
Patient Instructions English Introduction ApneaLinkAir ApneaLink Plus Your physician or healthcare provider has given you the ApneaLink Air device to test if you have sleep-disordered breathing. The device
PAR Tablet 10 Quick Start Guide
ParTech, Inc. 8383 Seneca Turnpike New Hartford, NY 13413 p.800.458.6898 www.partech.com PAR Tablet 10 Quick Start Guide PN 770505503 This material has been created in order to accommodate a wide range
THE NEW GENERATION IN TECHNOLOGY. NI-3103A Alarm Clock w/fm Radio ipod & iphone Docking. Operating Instructions
THE NEW GENERATION IN TECHNOLOGY NI-3103A Alarm Clock w/fm Radio ipod & iphone Docking Operating Instructions Table of Contents Important Safeguards... 3 Parts... 6 Controls... 6 To Set Up... 7 ipod/iphone
CFMRI Physiological Monitoring System. Operator s Manual
CFMRI Physiological Monitoring System Operator s Manual This manual provides a quick guidance to using the physiological monitoring system during an MRI session. It is not intended as a substitute for
Chapter2. Installation
Chapter2. Installation Power Supply Requirements The ULM-1000C operates from a DC supply of 20 30V and will typically draw less than 0.08A. All electronic products are susceptible to electrostatic shock,
Model: 308-1412 Manual DC: 080215 WIRELESS COLOR FORECAST STATION
Model: 308-1412 Manual DC: 080215 WIRELESS COLOR FORECAST STATION FRONT VIEW SENSOR TX141TH-Bv2 LED TX Sensor Battery Cover Sensor Battery Compartment 2 AA Buttons Battery Compartment 3 AAA BACK VIEW Battery
How To Use A U.S. Cell Phone At Home
U.S. Cellular Home Phone 1 Contents Getting to Know Your Device...5 Appearance... 5 LED Indicators... 6 Device Installation...7 Before You Begin... 7 Installing the Battery... 7 Installing the Power Adapter...
Optical Power Meter. Specification & User Manual
Optical Power Meter Specification & User Manual Page 1 of 9 Copyright 2011 reserves the right to modify specifications without prior notice Table of Contents 1. Description and Features.......3 2. Specification......4
ENGLISH...3 DEUTSCH...13 FRANÇAIS...23 ESPAÑOL...33 ITALIANO...43 PORTUGUÊS...53
USERS GUIDE ENGLISH...3 DEUTSCH...13 FRANÇAIS...23 ESPAÑOL...33 ITALIANO...43 PORTUGUÊS...53 NEDERLANDS...63 SVENSKA...113 TABLE OF CONTENTS USERS MANUAL FOR CEFAR MYO XT AND CEFAR ACTIV XT ENGLISH 3 PRECAUTIONARY
UK s best selling phone brand. User Guide. BT Decor 2200 Corded Phone
UK s best selling phone brand User Guide BT Decor 2200 Corded Phone 2 This User Guide provides you with all the information you need to get the most from your phone. Before you make your first call you
User Manual Table of Contents. Instructions for Using the LaserTouchOne Charging the Unit... 5 Holding the Device... 5 Treatment Steps...
User Manual User Manual Table of Contents Introduction The LaserTouchOne... 3 Device Features and Controls (Photo of device)... 4 Product Contents... 4 Laser Safety... 4 Electrical Safety... 5 Instructions
OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump
R-410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H)-System, DFC4(A/H)3-Outdoor, DFF4(A/H)H-Indoor Please read the operating instructions and safety precautions carefully
Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE
Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards 1.2 PACKAGE
Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer
User Manual Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer MODEL 42515 Introduction Congratulations on your purchase of the Model 42515 IR Thermometer. The Model 42515 IR thermometer
How To Use A Meter
Table of Contents Title I UT391 Product Introduction II Unpacking Inspection III Safety Instruction IV Meter Structure V Setting and Operation of Meter VI Technical specifications VII Maintenance 3 4 5
Thermocouple Thermometer Models
Technology Made Easy... Thermocouple Thermometer Models 60010-00 (Type J) 60010-10 (Type K) 60010-20 (Type T) 68X309905 Rev 1 04/04 TABLE OF CONTENTS 1. INTRODUCTION 4 2. SAFETY PRECAUTIONS 6 3. SPECIFICATIONS
Changers Kalhuohfummi User Manual
Changers Kalhuohfummi User Manual Contents 02 Contents 1. The Changers Kalhuohfummi an introduction to your solar battery 2. Introduction to energy tracking 3. Content and compatibility 4. Controls and
Dual Laser InfraRed (IR) Thermometer
User s Manual Dual Laser InfraRed (IR) Thermometer MODEL 42511 Introduction Congratulations on your purchase of the Model 42511 IR Thermometer. This Infrared thermometer measures and displays non-contact
IN-OUT Thermometer with Cable Free Sensor and Clock
IN-OUT Thermometer with Cable Free Sensor and Clock MODEL: RAR232 USER'S MANUAL INTRODUCTION Congratulations on your purchase of the RAR232 In-Out Thermometer with 433MHz cable free sensor and calendar
CanalPro TM Apex Locator
CanalPro TM Apex Locator User s Manual FOR DENTAL USE ONLY Table of Contents 1.0 Introduction... 4 1.1 Indications for use..... 4 1.2 Contraindications... 4 1.3 Warnings... 4 1.4 Precautions... 4 1.5
How To Use An Easy Ecg Monitor
Instructions to User Dear Users, Thank you very much for purchasing our product. Please read the manual very carefully before using this device. These instructions describe the operating procedures to
Laerdal Patient Monitor Help Page 1 June 14, 2012, Rev E
Laerdal Patient Monitor Help Page 1 Using the Laerdal Patient Monitor The Laerdal Patient Monitor software is used to simulate a typical Patient Monitor found in hospitals and ambulances. It is made available
2 YEAR WARRANTY S7200PAU USE & CARE MANUAL ADVANCED CERAMIC TECHNOLOGY. To register your product go to www.remington-products.com.
USE & CARE MANUAL PLEASE READ PRIOR TO USE To register your product go to www.remington-products.com.au ADVANCED CERAMIC TECHNOLOGY 2 YEAR WARRANTY S7200PAU 1 IMPORTANT SAFEGUARDS Warning: When the straightener
Important Safeguards
Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the
Installation and Operating Manual p. 23. Radio push button 2 channel: HM-PB-2-WM55-2
Installation and Operating Manual p. 23 Radio push button 2 channel: HM-PB-2-WM55-2 1. English edition 10/2013 Documentation 2013 eq-3 Ltd., Hong Kong All rights reserved. No parts of this manual may be
e 1 0 0 I N S T RUC TION M ANU A L
e 1 0 0 I N S T RUC TION M ANU A L The Empire Digital Level Accuracy, Readability, Durability one FEATURES: Easy to read back light Display reads right side up even if the level is upside down Audio beep
PA500II Enterprise Mobile Computer
PA500II Enterprise Mobile Computer - PA500II - Quick Reference Guide 400891G Version 1.0 PA500II Product Introduction & Accessory Kit After opening the box, ensure the following accessories for the PA500II
TS1200 Intelligent Lead Free Soldering Station. Operation Manual
TS1200 Intelligent Lead Free Soldering Station Operation Manual Thank you for purchasing an Intelligent Lead Free Soldering Station. It is designed for lead free soldering. Please read this manual before
Targus Wireless RF Mouse USER S GUIDE. Making Your Mobile Life Easier.
Targus Wireless RF Mouse Visit our Web site at: www.targus.com Features and specifications are subject to change without notice. 2004 Targus Group International and Targus, Inc.. 400-0111-001B USER S GUIDE
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
USER GUIDE. LED Light Meter. Model LT45
USER GUIDE LED Light Meter Model LT45 Introduction Congratulations on your purchase of the Extech LT45 LED Light Meter that measures light from LED lamps in addition to fluorescent, metal halide, high
PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: WWW.BRITEQ-LIGHTING.COM TABLE OF CONTENTS
STGE COO 48 Preliminary User Guide Official version will follow soon on: WWW.BITEQ-IGHTIG.COM TBE OF COTETS 1. Safety Instruction 2. Technical Specification 3. How To Set The Unit 4. How To Control The
EXERGEN. English. TemporalScanner TM. Accurate Temperature with a Gentle Forehead Scan. Operators Manual for TAT-5000
EXERGEN TemporalScanner TM Accurate Temperature with a Gentle Forehead Scan English Operators Manual for TAT-5000 English ~ Deutsch ~ Español ~ Français ~ Italiano ~ Nederlands ~ Português (UE) ~ Türkçe
Model UT713 OPERATING MANUAL
Model UT713 OPERATING MANUAL TABLE OF CONTENTS TITLE PAGE Introduction Unpacking Inspection Safety Information Turning the Calibrator On Simulating a Thermocouple Measuring a Thermocouple Simulating TC
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
Patient Monitor UP-7000. User Manual
Patient Monitor UP-7000 User Manual This Manual is written and compiled in accordance with the IEC 60601-1(Medical electrical equipment Part1: General requirements for safety), and MDD 93/42/EEC.It complies
How To Use An Easypad On A Pc Or Macbook Or Ipad (For Pc)
User Guide Congratulations on your new EasyPad 1000. Please follow the instructions in this manual carefully. Statement: If the final version of this product has any differences from the description of
SDX Submersible Depth Transmitter User Manual
SDX Submersible Depth Transmitter User Manual January 2011 USER INFORMATION Stevens makes no warranty as to the information furnished in these instructions and the reader assumes all risk in the use thereof.
ENGLISH USER S MANUAL. compact handheld 1D/2D code scanner
ENGLISH USER S MANUAL compact handheld 1D/D code scanner 11175-en-GB 5J006 04 006 1 3 A B 4 C INSTALLATION INSTRUCTIONS FIRST STEP: TURN POWER OFF! Exercise caution at all times when working with AC and
Wireless Indoor/ Outdoor Thermometer
Wireless Indoor/ Outdoor Thermometer Owner s Manual Please read before using this equipment. ˆ Contents FCC Information... 3 FCC Declaration of Conformity... 5 Preparation... 5 Installing Batteries...
MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating
MAKING MORN LIVING POSSIBLE Danfoss heating living connect Installation and User Guide Contents 1.0 System overview... 3 2.0 Overview of display and control buttons... 3 3.0 Installation - step by step...
PART 1 PRODUCT (GENERAL)...1.
TABLE OF CONTENTS PART 1 PRODUCT (GENERAL)...1. 1.1--PRODUCT INTRODUCTION...1. 1.2--PRODUCT FEATURES...1. 1.3--TECHNICAL SPECIFICATIONS...2. 1.4--PHOTOMETRIC DATA...3. 1.5--SAFETY WARNING...4. PART 2 INSTALLATION...5.
How To Use The Visifault Visual Fault Locator
VisiFault Visual Fault Locator Instruction Sheet The VisiFault Visual Fault Locator (VFL) is a visible light source that helps you trace optical fibers, check fiber continuity, and find faults such as
Jarv Nmotion BTHL-201 Bluetooth Stereo Earbuds Users Guide
Jarv Nmotion BTHL-201 Bluetooth Stereo Earbuds Users Guide Features: Bluetooth wireless technology Comfortable lightweight in-ear design with detachable sports ear hooks for added support High Definition
alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS
alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS Safety precautions Safety precautions The DSL modem alpha DSL WTM HS complies with the European norm EN60950 safety of information technology
DSM155 Digital LED Light Meter User s Manual DSM155
DSM155 Digital LED Light Meter User s Manual DSM155 CONTENTS TABLE OF CONTENTS......3 LIMITED WARRANTY AND LIMITATION OF LIABILITY......3 Out of Box....3 Accessories....3 Safety Information....3 Certification....5
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
Atomic Alarm Clock model 13131W2
Instruction Manual Atomic Alarm Clock model 13131W2 CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits... 3 Clock Setup... 4 Atomic Clock... 5 Set
