High efficiency, cast-iron gas boiler



Similar documents
GALAXY. High performance gas boilers HOT WATER AND STEAM NATURAL AND L.P. PROPANE GASES

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Commercial Gas Water Heaters

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Cooling Capacity CFM in. w.c. (125 Pa)

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED

Originators of the Flexible Water Tube design

Commercial Gas Furnace Upflow

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

2010 Residential Water Heater Replacement Check List

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

OTF Oil Fired Pool Heater

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

NAVIEN AMERICA INC FITCH AVENUE

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

Gas-Fired, Residential Storage Type Water Heaters

Commercial Gas Water Heater

Buderus. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. G315 G515 G615 Cast Iron Commercial Boilers.

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

Commercial Gas Water Heaters

Electric & Gas Water Heaters

Steam systems require higher temperatures, which make them inherently less efficient than forced air or hot water.

NFPA31FuelOilPiping 1 Revised

DRAFT HOOD OUTLET GS6-30-YORT NG Select - Tall - C3 Technology 28 FIRST HOUR RATING BTU INPUT PER HOUR

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

TANKLESS DURABILITY Tankless Product Guide

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

Cooling Capacity CFM in. w.c. (125 Pa)

Boston, Venice, Kodiak. Enviro Wood Fireplace Inserts

Cooling Capacity CFM in. w.c. (125 Pa)

Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home

CABINET. A Clean Burn Heat Exchanger provides approximately 200% more surface area for capturing combustion heat. You get more heat from less oil.

ASX7-4-IOM-7 J

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Steam System Best Practices Condensate System Piping

1 DESCRIPTION OF THE APPLIANCE

Electric Flow Boiler

User's Instructions. Alpha HE CB25/33 and HE SY25

HEAVY DUTY STORAGE GAS

Commercial Semi-Instantaneous Water Heaters

Your safety and the safety of others are very important.

UDSA - UDSBD unit heater

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER

Using Water Heaters for Radiant Heat

G234X-55 Conventional Gas Boiler

HYDRONIC DESIGNER / INSTALLER MODULE DESCRIPTIONS

OIL FURNACES. Clean, Comfortable Oil Heat From

Glossary of Heating, Ventilation and Air Conditioning Terms

Overview of Baseboard Heating

Versatility ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO.

Evaluate, Clean, and Tune Guidance

Energy Efficiency HOSPITALITY.

Boiler Installation and Maintenance Manual

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

SOLI TANKLESS PRODUCT GUIDE

STATE SUPER HIGH EFFICIENCY Up To 96% Thermal RESIDENTIAL PREMIER POWER-VENT MODELS

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

HS-901(A) BASIC STEAM HEATING SYSTEMS

Boiler Plan II Table of Contents

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

Integrated Solar Radiant Systems

When considering your heating options, keep in mind that 60% of your energy. costs are attributed to space heating. You

PLAN REVIEW SERVICES CONSTRUCTION DOCUMENTS NECESSARY FOR A THOROUGH PLAN REVIEW

Boiler and Burner Cleaning and Servicing Specifications

Spare Parts List M96A.24SM/B M96A.28SM/B

ASME Packaged Indirect Fired Water Heater

XV 95. Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace PUB. NO.

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

F9MXE. Product Specifications

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

Watts Spacemaker. Sa f e t y Wa t e r He a t e r. Enclosures Stands Restraints

Response: The combi boiler. Response: The fit anywhere combi

REGULATORS 175/153 Series

PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM 11/21/11 1:41 PM

Commercial Gas Water Heaters

Light Duty Commercial Electric Water Heater

UNDERSTANDING CENTRAL HEATING SYSTEMS

Arapahoe County Residential Water Heater Installation and Inspection Guide

Boiler Preparation, Start-Up and Shutdown

Condensing Boiler Efficiency

warm air for the healthiest, most comfortable home environment possible. This occurs with a system efficiency of up to 90%.

Fully Pumped Systems

STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE

RECON WATER HEATER INSTALLATION FORM

Cast Iron Radiator Heating Capacity Guide

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

Boiler & Pressure Vessel Inspection discrepancies and failures

GAS STOVES woo GAS STOVES

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

E-gas Instant Gas Water Heaters

SPIDERfire: Delivers high efficiency and real savings for today s businesses

Transcription:

SENTRY High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

SENTRY High efficiency, cast-iron gas boiler A smarter choice for informed The boiler you choose for your home now will affect your family s comfort--and pocketbook--for many years to come. Sentry boilers provide a blend of efficiency and reliability that will keep your home comfortably warm and your fuel costs low year after year. A new Sentry boiler can save up to 30% or more on fuel bills compared to a typical old boiler operating at 60% efficiency. SA input: S models 0 000 W to 44 000 W (34,000 to 50,000 Btu/hr) Low clearance Intermittent ignition. Saves energy. AFUE to 84.4% Sentry is ideal for a wide variety of gas boiler requirements, as a replacement or for new installations. Its advanced design provides years of trouble-free, high efficiency operation while providing easy installation, even in sites with low chimney connections or low overhead clearance. Sentry is a reliable natural draft boiler. Many boilers resort to pulsing or condensing technologies, copper fin-tubes and thermal bypass valves to attain acceptable efficiency. Sentry achieves high efficiency with fewer components, so there's less chance of part failure or losing your heat. Sentry s efficiency to 84.4% is among the highest in the industry. Sentry s heat exchanger is made of quality cast-iron and assembled with durable metal push nipples. It's so reliable it comes with a lifetime limited warranty. Sentry boilers respond quickly to your thermostat s call for heat, sending heat within moments to radiators throughout your home. Low profile makes problem installations easy. The Sentry boiler fits into replacement sites with low chimney breeching or low overhead clearance. The Sentry models include an integral draft diverter and do not require a draft hood. They fit into replacement sites with overhead clearance or chimney breeching as low as 978mm (38 2in.) above the floor.* This is nearly a foot and a half less clearance than required by typical natural draft boilers. The rear flue outlet keeps the vent pipe out of the way of water and gas piping. Installation is faster and trimmer. Sentry with integral draft diverter The computer-aided design of Sentry s venting system enables the Sentry boiler to perform effectively under a wide range of draft conditions. Sentry is one of the industry s most versatile and durable high efficiency boilers. LOW-PROFILE VERSATILITY. NATURAL DRAFT RELIABILITY *See installation instructions for specific applications and clearances.

homeowners. Natural draft reliability and high efficiency too. Enjoy the easy installation and reliable operation that natural draft design provides, plus high efficiency too. With intermittent pilot ignition,sentry AFUE's range from 83.% to 84.4%.

omputer-aided design. Highest quality manufacturing. Superior components. Advanced design heat exchanger with metal push nipples provides superior performance, longer life. omputer-aided design of heat exchanger maximizes transfer of heat from the gas flame to the boiler water which then flows into your heating system. Superior heat transfer properties permit use of smaller, compact cast-iron heat exchanger sections. The flue passage design, thermal pin pattern and consistent wall thickness ensure uniform heat transfer with less thermal strain and metal fatigue. Metal push nipples avoid leaks. Slant/Fin uses only metal push nipples that expand and contract with the individual boiler sections that they connect. In many ordinary boilers, flimsy rubber or plastic gaskets are substituted for metal push nipples and are subject to deterioration and leaks. Reliable heavy-duty vent damper saves energy. The motorized Slant/Fin vent damper increases efficiency of the boiler by reducing standby losses. Motor closes the chimney vent when the burner is off, fully opens it in anticipation of combustion. May be installed horizontally or vertically to accommodate varying vent pipe requirements. Heavy-duty collar maintains dimensional stability for smooth operation. Insulated base Base is constructed of heavy gauge aluminized steel. Thick refractory insulation surrounds combustion chamber, minimizing standby losses and increasing efficiency. Long-life burners Quiet, light and easy to install or remove. Same stainless steel burners serve natural or propane gas. Special port construction will not permit flame to lift or flash back. Sentry burners last longer too because of low operating temperature. Input per burner is only 4 500 W (5,000 Btu/hr.)

SENTRY High efficiency, cast-iron gas boiler Motorized heavy-duty vent damper Relief valve Integral draft hood ast-iron heat exchanger Thermal pins Safety high limit, Low water cutoff, Water temperature adjusting control. Pressure temperature gauge Insulated jacket Blocked vent safety switch Not visible in photo Metal push nipples Insulated base Long life burners Rollout safety switch irculator pump (optional on some models) Gas valve

Make your house a more comfortable home With a Sentry boiler at the heart of your heating system, you can enjoy deluxe heating comfort all around your home. A Sentry boiler can be installed to provide heating energy for any or all these hydronic heating systems: Zone heating with Slant/Fin hot water baseboard and individual room temperature controls. 2 Slant/Fin hot water fan-convection heaters under cabinets or stairs. 3 Pool or spa water heating with a Slant/Fin boiler and external heat exchanger. 4 Towel warmers for bathrooms. 5 Hot water with an indirect-fired water heater. 3 3 2 2 4 5 Zone your heating system for even greater fuel savings. By dividing your home into separate heating zones, you can save energy by heating only those areas you re using. Depending on your existing piping arrangement, it may be quite simple to zone your system.

RATINGS FOR SENTRY BOILERS--NATURAL AND L.P. GAS MODEL NO. SA RATINGS* FOR WATER SA INPUT W Btuh GROSS OUTPUT W Btuh W NET RATINGS+ WATER WATER Btuh S-34 0 000 34,000 9 000 29,000 7 000 25,000 6 67 84.0% 206 8 /8 37 4 5 /8 02 4 S-60 8 000 60,000 5 000 5,000 3 000 44,000 27 293 84.4% 283 /8 448 7 5 /8 02 4 S-90 26 000 90,000 22 000 76,000 9 000 66,000 4 440 84.2% 359 4 /8 524 20 5 /8 27 5 S-20 35 000 20,000 30 000 0,000 26 000 88,000 55 587 84.% 435 7 /8 600 23 5 /8 52 6 S-50 44 000 50,000 37 000 25,000 32 000 09,000 68 727 83.4% 5 20 /8 676 26 5 /8 78 7 m 2 Sq. ft. SA EFFIIENY (with vent damper) INTERMITTENT IGNITION mm A in. DIMENSIONS B Vent Diameter mm in. Integral Draft Diverter mm in. * Ratings are for sea level to 60m (2,000 ft) elevation. For elevations over 60m (2,000 ft) reduce ratings by 0%. + Net ratings are based on a piping and pick-up allowance of.5 (hot water). Slant/Fin should be consulted before selecting a boiler for installation having unusual piping and pick-up requirements. Type of gas: after model number, specify gas by name Natural or Propane. Dimensions MODEL S-34 G H I 02mm (4") Field ontrol (Effikal) Vent Damper G H I (-3/6") 52mm 22mm (4-3/6") 38mm ( /2") Supply Dimensions MODEL S-60 to S-50 G H I Field ontrol (Effikal) Vent Damper G H I 02mm (4") 27mm (5") 52mm 78mm (7") (-3/6") (-3/6") (-3/6") (-3/6") 52mm 52mm 65mm (6-/2") 79mm (7-/6") 22mm (4-3/6") 22mm (4-3/6") 35mm (5-5/6") 49mm (5-7/8") 38mm ( /2") Supply 502mm (9 3 /4") Vent Damper* 502mm (9 3 /4") Vent Damper* Integral Draft Diverter Pressure/Temp. Gauge Blocked Vent Safety Switch 9mm ( 3 /4") to air eliminating system (by others) 9mm ( 3 /4")Drain Rollout Safety Switch (behind front panel) Supply Piping (by others) Pressure/Temp. Gauge 9mm ( 3 /4")Drain Rollout Safety Switch (behind front panel) 65mm (6 /2") A A B B 9mm ( 3 /4") to air eliminating system (by others) 722mm (28 7 /6") 824mm (32 7 /6") High Limit. ontrol Ignition ontrol irculator: 32mm (-/4") irc. Flange 38mm (-/2") ReturnTapping ombination Gas Valve (gas tapping 3mm [/2"] ) High Limit ontrol Ignition ontrol irculator: 32mm (-/4") irc. Flange 38mm (-/2") ReturnTapping ombination Gas Valve (gas tapping 3mm [/2"] ) Ground Joint Union LEFT END VIEW FRONT VIEW RIGHT END VIEW Blocked Vent Safety Switch Ground Joint Union Sediment Trap (required) (Dotted piping by others.) Sediment Trap (required) (Dotted piping by others.) Dimensions MODEL SX-50 to SX-20 G H I Field ontrol (Effikal) Vent Damper G H I 52mm 78mm (7") (-3/6") (-3/6") 52mm 79mm (7-/6") 22mm (4-3/6") 49mm (5-7/8") 38mm ( /2") Supply LEFT END VIEW FRONT VIEW RIGHT END VIEW 502mm (9 3 /4") 9mm ( 3 /4") to air eliminating system (by others) Supply Piping (by others) Pressure/Temp. Gauge 9mm ( 3 /4")Drain Rollout Safety Switch (behind front panel) * Vent damper may be installed horizontally on all models with use of a common Vent Damper* vent elbow. Vent Damper* A B Blocked Vent Safety Switch 722mm (28 7 /6") Ignition ontrol irculator: 32mm (-/4") irc. Flange 38mm (-/2") ReturnTapping High Limit ontrol ombination Gas Valve (gas tapping 3mm [/2"] ) Ground Joint Union D Sediment Trap (required) (Dotted piping by others.) LEFT END VIEW FRONT VIEW RIGHT END VIEW *Vent damper may be installed horizontally on all models with use of a common vent elbow.

SENTRY High efficiency, cast-iron gas boiler Engineered for comfort, safety and reliability. Lower profile, higher efficiency Millions of homes are equipped with Slant/Fin hydronic heating. SLANT/FIN LTD/LTEE, 6450 Northam Drive, Mississauga, ON L4V H9 Phone: (905) 677-8400 Fax: (905) 677-829 Order Desk Fax: (905) 677-905 www.slantfin.ca E-mail: orderdesk@slantfin.ca info@slantfin.ca Slant/Fin orp. 2003. Printed in anada HG-03/3. Publication No.S0.