Introduction. Product Research & Development



Similar documents
Introduction. Internet:

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2

SUNON SPECIFICATION FOR APPROVAL

+ A B V B NO NC V COM PV PV

RELAYS Solar Energy Systems

Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.

Solar Inverters. Ferrites in Renewable Energies: Solar Inverters. customer requirements. Support and flexibility to design custom product to fulfill

Miniatur Radial Gebläse mit integrierter Elektronik Miniature Radial Blower with integrated electronic

MAXIMUM LOAD CURRENT 1 A SN SERIES

MAJORSINE Power Inverter

I STAR COMPUTER CO., LTD

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)

Data Center Cooling. The engineer s choice

Energy Saving ECM Motors and Fans Ventilation Catalogue

Phase Modular Finally the benefits of Modular ups are for all

Series AMLDL-Z Up to 1000mA LED Driver

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES

High Power LED Driver Series User s Guide

ebm-papst North America

SWITCH-MODE POWER SUPPLY CONTROLLER PULSE OUTPUT DC OUTPUT GROUND EXTERNAL FUNCTION SIMULATION ZERO CROSSING INPUT CONTROL EXTERNAL FUNCTION

MINIATURE SURFACE MOUNT RELAY

COMPACT POWER TWIN RELAY

LM78XX Series Voltage Regulators

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

TDA2822 DUAL POWER AMPLIFIER SUPPLY VOLTAGE DOWN TO 3 V LOW CROSSOVER DISTORSION LOW QUIESCENT CURRENT BRIDGE OR STEREO CONFIGURATION

7-41 POWER FACTOR CORRECTION

POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

2 X 250Watt Class D Audio Amplifier Board IRS2092 User s Guide

D.C. Motors. Products and specifications subject to change without notice.

SILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES

14. Troubleshooting Guide

AN2680 Application note

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

LM566C Voltage Controlled Oscillator

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

HERZ-Thermal Actuators

Contents. Document information

Amphenol LTW Technology Co., Ltd. Amphenol LED Market. Innovation in Waterproof Solution

EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.

Antec TruePower User's Manual

PowerAmp Design. PowerAmp Design PAD135 COMPACT HIGH VOLATGE OP AMP

FACTORY AUTOMATION INTELLIGENT CLAMP MONITORING FOR MACHINE TOOL SPINDLES WITH INDUCTIVE POSITIONING SYSTEMS

NC-12 Modbus Application

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Process Alarm Solutions

User s Manual Before using the inverter, you need to read and save the safety instructions.

LM 358 Op Amp. If you have small signals and need a more useful reading we could amplify it using the op amp, this is commonly used in sensors.

ADM1TE 5/30A DIN rail single phase two wire energy meter

Audible Alarm Basics Everything you wanted to know, but were afraid to ask by Dan O Brien, Sales Engineer, Mallory Sonalert Products, Inc.

CLASS-D VERTICAL DEFLECTION AMPLIFIER FOR TV AND MONITOR APPLICATION OUT CFLY + CFLY - BOOT VREG FEEDCAP FREQ. July /8

L78M00 SERIES POSITIVE VOLTAGE REGULATORS.

Talon and Talon SR User Manual

EFFECT OF OBSTRUCTION NEAR FAN INLET ON FAN HEAT SINK PERFORMANCE

2 POLES 1 to 2 A (FOR SIGNAL SWITCHING)

Photovoltaic Solar Energy Unit EESFB

Fan Basics and Selection Criteria (How to Use)

Surface Technology. Centrifugal Fan GMD

ECOCIAT. Domestic hot water heat recovery unit

SX460. Generator Automatic Voltage Regulator Operation Manual

LM134-LM234-LM334. Three terminal adjustable current sources. Features. Description

LM1596 LM1496 Balanced Modulator-Demodulator

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

Features. Dimensions

Frequency Converter Fv

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

A SERIES. 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY. RoHS compliant

2SK1056, 2SK1057, 2SK1058

Specifying a Variable Frequency Drive s

WHITE LED STEP-UP CONVERTER. Features

LM134-LM234 LM334 THREE TERMINAL ADJUSTABLE CURRENT SOURCES. OPERATES from 1V to 40V

The quadrature signals and the index pulse are accessed through five inch square pins located on 0.1 inch centers.

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Regards from the Team at Rheology Solutions.

HCF4056B BCD TO 7 SEGMENT DECODER /DRIVER WITH STROBED LATCH FUNCTION

Agilent 4338B Milliohm Meter

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Description. Dimensions. Features. precision works better

1 POLE - 5A SLIM POWER RELAY

Features. Symbol JEDEC TO-220AB

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Speed Control Relays SX2

STGW40NC60V N-CHANNEL 50A - 600V - TO-247 Very Fast PowerMESH IGBT

HCC4541B HCF4541B PROGRAMMABLE TIMER

Features. Dimensions

PM734F - Technical Data Sheet Winding 28

*.ppt 11/2/ :48 PM 1

MITSUBISHI ELECTRIC ANNOUNCES PHOTOVOLTAIC INVERTER FOR EUROPEAN MARKET

1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series

Agilent AEDB-9140 Series Three Channel Optical Incremental Encoder Modules with Codewheel, 100 CPR to 500 CPR Data Sheet

LM337. Three-terminal adjustable negative voltage regulators. Features. Description

Micro cogeneration. Affordable, efficient and innovative

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

Transcription:

Application

Introduction instruments and equipment gives Delta very strong design capability. Advanced engineering equipment such as Star-LT simulation software, computerized CNC machines, semi-anechoic chambers and wind tunnels are used to develop high performance, low noise and cost effective products. Manufacturing Plant 2 in Taoyuan, Taiwan Quality Assurance Delta is an ISO-9001 and TS-16949 certified manufacturer for brushless DC air cooling products. We implement strict reliability tests in the design stage and have put into place Statistical Process Controls at each production process. More than 17 years Delta has gained industry's recognition, confidence and commendation by continuously offering innovative quality brushless DC air cooling products. Broad product range covers axial fan from 25mm-200mm, blowers from 30mm-175mm, cross-flow fans and slim blowers. In combine with patented distinctive blade design, innovative structure design and "Sensflow" control not only greatly increase cooling performance but also reduce system noise with temperature sensor control when the fan is in low load operation. Fans with hot-swap construction, fan trays and modules with strong pan and first-rate efficiency are also produced. Product Research & Development Innovations are everywhere in our products. Engineering expertise backed by sophisticated test Manufacturing Delta's automation department is highly specialized in computerized state-of-the-art equipment. We build our own fully automated production lines in-house. This allows us to provide large production capacity and high quality, cost effective products to our customers. Global Operations A worldwide network of sales and technical support teams is available to our customers in Asia, USA and Europe. These teams are assisted by local designengineering centers. Delta Group is utilizing a SAP RI3 system to facilitate and optimize its linkage with customers and suppliers, allowing it to effectively monitor and maintain its world-wide logistics operations. Manufacturing Plant in Wujiang, China Manufacturing Plant in Dongguan, China Manufacturing Plant in Bangkok, Thailand

Evaluation Facilities ISO 3745 Anechoic Chamber Noise Chamber: Residual background noise Level : 10.0 db(a) Lowest cutoff frequency: 80 Hz Room Volume: 5.2m x 5.0m x 3.2m Instrument: HEAD acoustics System impedance noise measurement : ISO 10302 International standard Sound Power Sound Quality Sound Pressure Static Pressure Range: 0 ~ 100 & 127 mmh O 2 Air Flow Rate Range: 10 CFM, 20 CFM, 200 CFM, 250 CFM, 1000 CFM, & 3000 CFM. PL.1 PL.2 0.5J PL.7 J PL.5 PL.6 0.5 M MIN 1.5 IN. 0.25IN SETTLING MEANS (see note 5) M VARIABLE EXHAUST SYSTEM Wind Tunnel SETTLING MEANS Waterproof fan Currently, many customer system applications in telecom and other industries are for outdoor or relatively harsh environments. Waterproof and dustproof fans are required under these conditions. In accordance with IEC60529 and the development and design for fan motor assembly protection, Delta has the capability to produce IP55 level fans. Delta production has already installed equipment to meet IEC & NEBS conditions as well as additional functional testing for other customer requirements. IPX5 IP5X

Telecommunication Fans Axial fan Impeller : Plastic Frame : Plastic Model Dimension Rated Voltage Operating Voltage Range Max. Speed Rated Imput Power Max. Air flow Max. Air pressure Noise Part No. L x L x T (mm) VDC VDC RPM Watt CFM IN H2O db-a AFB06X-A 60 x 60 x 25.4 24 / 48 14 to 27.6 / 28 to 56 6800 5.76 / 6.72 38.35 0.544 46.5 AFB06XE 60 x 60 x 38 24 14 to 27.6 8000 9.12 46.17 0.793 50.0 FFB06XE 60 x 60 x 38 24 14 to 26.4 8000 11.16 50.15 0.972 54.5 AFB08X 80 x 80 x 25.4 24 / 48 14 to 26 / 28 to 56 4000 / 3250 3.84 / 3.84 46.62 / 37.43 0.267 / 0.181 40.0 / 34.0 FFB08XE 80 x 80 x 38 24 / 48 14 to 26.4 / 28 to 56 5700 / 4900 12.00 / 7.68 80.16 / 68.51 0.812 / 0.591 52.5 / 48.5 PFB08XE 80 x 80 x 38 24 14 to 26.4 9000 32.40 132.56 2.030 65.0 GFB08XG 80 x 80 x 50.8 24 14 to 27.6 4200 8.88 68.58 0.445 53.0 AFB09X 92 x 92 x 25.4 24 / 48 14 to 27.6 / 28 to 56 3800 / 3200 5.28 / 3.84 67.80 / 57.92 0.302 / 0.221 45.0 / 38.0 FFB09X 92 x 92 x 25.4 24 / 48 14 to 27.6 / 28 to 53 3700 7.44 / 8.16 81.97 0.319 48.2 FFB09XE 92 x 92 x 38 24 / 48 14 to 27.6 / 28 to 53 4800 / 4400 12.00 / 9.60 110.18 / 100.29 0.665 / 0.572 55.0 / 52.5 PFB09XE 92 x 92 x 38 24 / 48 14 to 26.4 / 28 to 56 8000 / 7000 34.80 / 28.80 175.03 / 153.52 1.819 / 1.440 66.5 / 64.0 GFB09XG 92 x 92 x 50.8 24 / 48 14 to 27.6 / 28 to 56 3700 14.40 / 15.36 91.82 0.505 59.0 AFB12X 120 x 120 x 25.4 24 14 to 27.6 3400 6.72 113.11 0.430 46.5 FFB12X 120 x 120 x 25.4 24 / 48 14 to 26.4 / 28 to 53 4000 15.12 / 15.36 150.33 0.489 56.4 EFB12XF 120 x 120 x 32 24 / 48 7 to 26.4 / 28 to 56 4400 10.56 139.85 0.563 55.5 AFB12XE 120 x 120 x 38 24 / 48 7 to 27.6 / 28 to 56 3700 / 3200 12.00 / 8.64 151.85 / 129.96 0.571 / 0.420 53.0 / 48.0 EFB12XE 120 x 120 x 38 24 / 48 7 to 27.6 / 28 to 56 3700 10.56 / 9.60 141.96 0.520 52.5 FFB12XE 120 x 120 x 38 24 / 48 14 to 26.4 / 28 to 53 4000 24.00 / 24.00 190.00 0.700 59.0 TFB12XE 120 x 120 x 38 24 / 48 18 to 27 / 28 to 53 4600 28.80 / 31.20 220.01 1.041 65.0 PFB12XE 120 x 120 x 38 24 / 48 14 to 26.5 / 30 to 56 5500 48.00 / 48.00 252.85 1.412 66.5 GFB12XG 120 x 120 x 50.8 24 / 48 14 to 26.4 / 28 to 56 3700 43.20 / 32.64 203.41 0.820 67.6 GFB12XW 120 x 120 x 76.2 24 / 48 14 to 26.4 / 28 to 53 3550 29.04 / 29.76 220.29 0.592 59.0 FFB13XE 127 x 127 x 38 24 / 48 14 to 26.4 / 28 to 53 3850 28.80 / 32.16 200.02 0.799 59.5 FFB14XG 140 x 140 x 50.8 24 / 48 14 to 26.4 / 28 to 53 3600 36.72 / 36.96 273.09 0.781 61.7 The model name "X" letter means rotation speed that will be different for various models The max. air flow and the speed are measured in free air; max. air presssure is measured at zero air flow Axial fan Impeller : Plastic Frame : Metal Model Dimension Rated Voltage Operating Voltage Range Max. Speed Rated Imput Power Max. Air flow Max. Air pressure Noise Part No. L x L x T (mm) VDC VDC RPM Watt CFM IN H2O db-a FFB12XE-M 120 x 120 x 38 24 / 48 14 to 26.4 / 28 to 54 6300 78.00 / 79.20 264.62 1.705 73.5 FFB14XE-M 140 x 140 x 38 24 / 48 14 to 26.4 / 36 to 53 5500 80.40 / 86.40 367.62 1.644 74.0 AFB15X 172 x 150 x 25.4 24 / 48 12 to 30 / 24 to 60 3200 14.88 / 14.88 214.85 0.524 53.5 AFB17X 172 x 25.4 24 / 48 12 to 30 / 24 to 60 3200 14.88 / 14.88 214.85 0.524 53.5 EFB15XG 172 x 150 x 50.8 24 / 48 12 to 28 / 24 to 60 4300 / 4000 28.08 / 23.52 325.00 / 302.29 1.083 / 0.937 63.0 / 60.0 EFB17XG 172 x 50.8 24 / 48 12 to 28 / 24 to 60 4300 / 4000 28.08 / 23.52 325.00 / 302.29 1.083 / 0.937 59.0 / 57.0 FFB17XG 172 x 50.8 48 26 to 54 5000 120.00 450.98 1.837 74.0 FHB12XE-M 120 x 120 x 38 48 32 to 80 5800 61.44 245.83 1.502 71.5 AHB13XE 127 x 127 x 38 48 32 to 80 5500 36.00 255.77 1.448 67.0 FHB14XE 140 x 140 x 38 48 32 to 80 5000 65.28 346.34 1.434 71.0 AHB15X 172 x 150 x 25.4 48 32 to 80 4000 24.96 271.05 0.736 61.0 AHB17X 172 x 25.4 48 32 to 80 4000 24.96 271.05 0.736 61.0 AHB15XG 172 x 150 x 50.8 48 32 to 80 5200 72.96 402.72 1.964 68.5 EHB15XG 172 x 150 x 50.8 48 32 to 80 5200 57.60 374.62 1.703 68.5 AHB17XG 172 x 50.8 48 32 to 80 5200 72.96 408.39 2.048 66.5 EHB17XG 172 x 50.8 48 32 to 80 5200 57.60 394.22 1.761 66.0 FHB17XG 172 x 50.8 48 32 to 80 4400 76.80 388.25 1.395 71.5 The model name "X" letter means rotation speed that will be different for various models The max. air flow and the speed are measured in free air; max. air press sure is measured at zero air flow Specificatons are subject to change without notice.

Telecommunication Blowers Open blower Impeller : : Plastic Frame : Metal Model Dimension Rated Voltage Operating Voltage Range Max. Speed Rated Imput Power Max. Air flow Max. Air pressure Noise Part No. D x T (mm) VDC VDC RPM Watt CFM IN H2O db-a KFB10XS 100 x 55 24 / 48 14 to 26.4 / 28 to 53 5700 20.88 / 20.64 111.60 1.393 62.0 KFB17XS 175 x 54 24 / 48 14 to 30 / 28 to 60 4200 55.20 / 55.20 297.39 2.361 73.5 KFB17XT 175 x 69 24 / 48 14 to 26.4 / 36 to 53 3300 69.12 / 69.60 334.79 1.884 67.5 KFB17XT-A 175 x 69 24 / 48 14 to 27.6 / 28 to 53 4000 75.36 / 69.60 412.78 2.403 73.0 KHB10XS 100 x 55 48 32 to 80 6200 21.22 94.96 1.630 66.0 KHB17XS 175 x 54 48 32 to 80 3500 31.20 247.47 1.601 69.0 KHB17XT 175 x 69 48 32 to 80 2700 35.04 251.87 1.209 62.5 KHB17XT-A 175 x 69 48 32 to 80 3100 35.04 335.50 1.448 66.0 The model name "X" letter means rotation speed that will be different for various models The max. air flow and the speed are measured in free air; max. air pres ssure is measured at zero air flow Specificatons are subject to change without notice. FREQUENCY GENERATOR O/P: (F00) Frequency generator function is activated by an internal IC for customer's application. Electrical schematic: IC R O/P Vcc. IC F.G. OUTPUT ADDITIONAL PVC WIRE CUSTOMER'S CIRCUIT Vcc = From +5 To +28 VDC (Generally using +12 or +24 VDC) Ic = 5 ma max. R = V/I (Output "R" value calculation) SUPPLY A WAVEFORM: RUNNING FOR 4 POLES BLADE LOCKED OR T1 T2 T3 T4 TS RUNNING FOR 8 POLES T1=T2=T3=T4=1/4 TS T1 T2 T3 T4 T5 T6 T7 T8 TS T1=T2=T3=T4=T5=T6=T7=T8=1/8 TS N=R.P.M. (Rotation speed will be different for various models L/M/H/HH/VH/SH) TS=60/N (Sec) * Voltage level after blade locked * 4 POLES OR 8 POLES OUTPUT LEVEL: High = Vcc 10% Low = 0~0.5V Ic = 5 ma max. APPLICATION: TIMER ENABLE F.G. C.P.U. COUNTER CALCULATOR OF SYSTEM FUNCTIONS: By means of waveform & customer's design, schematic can reach alarm function, either in the form of buzzing or LED flashing. Adjust rotation speed. When power supply output voltage level decreases, it will result in the lowering of fan rotation speed. The irregular situation will be controlled by using F.G. O/P through P/S circuit to increase the output voltage and result in a stable rotation speed. ROTATION DETECTOR O/P (R00) Rotation detector function is activated by an internal IC for customer's application. Electrical schematic: IC R O/P Vcc. IC R.D. ADDITIONAL PVC WIRE CUSTOMER'S CIRCUIT BLADE LOCKED CUSTOMER'S CIRCUIT CUSTOMER'S CIRCUIT Vcc = From +5 To +28 VDC (Generally use +12 or +24 VDC) Ic = 5 ma max. R = V/I (Output "R" value calculation) OR SUPPLY A WAVEFORM: RUNNING OUTPUT LEVEL: High = Vcc 10% Low = 0~0.5V Ic = 5 ma max. APPLICATION: R.D. BLADE LOCKED I R ALARM/BUZZER FUNCTION: By means of waveform & customer's design, schematic can reach alarm function: either in the form of buzzing or LED flashing. TEMPERATURE CONTROL : "SENSFLOW" With temperature controlled fan, the RPM can be controlled by on board or off board thermistor. The RPM and temperature range is subject to custom request. Rth (Thermistor) Thermal control Speed (RPM) Voltoge Resistonce Speed (RPM) PWM CONTROL In PWM speed control, a fixed frequency square wave is applied to the speed control lead wire of the fan. The ratio of the on time vs. the PWM period is proportional to the RPM. PWM control t T PWM Signal Input _t Duty Cycle= T Customer Circuit PWM control Signal Output T1 Speed PWM INPUT VOLTAGE RANGE: High level= 2.8 to 20 VDC Low level= 0 to 0.4 VDC PWM INPUT CURRENT (IPWM) RANGE: 40uA to 20mA T2 Vth Rth o Temperature (C) o Temperature (C) o Temperature (C) To control signal line of the fan shall be able to accept a 30Hz to 30kHz. The preferred operating point for the fan is 0%~100% of duty cycle. Duty Cycle Speed % Duty Cycle

Delta STD 6 Fan tray Character: Fan Trays Model Rated Voltage Operating Temperature Speed Input Current Input Power Maximum Air Flow Maximum Air Pressure Noise Part No. VDC RPM Amp Watt CFM IN H2O db-a Delta STD 6 fan tray 48-10 ~ +55 4000 2.33 112 1070 0.708 74.5 The max. air flow and the speed are measured in free air; max. air press sure is measured at zero air flow Fan Type: 6pcs axial fan Communication: I^C Advantage: Soft Start, Over Voltage Protection,Over Current Protection, Fan Speed or Temperature Detect,PWM or Voltage Speed Control, Linear Speed Change, Hot Swappable Function, Thermal Fail or Over Temperature Alarm Signal Output,Redundancy Function,Reverse Polarity Protection,Inrush Current Protection,EEPROM,EMC Delta STD 9 Fan tray Character: Model Rated Voltage Operating Temperature Speed Input Current Input Power Maximum Air Flow Maximum Air Pressure Noise Part No. VDC RPM Amp Watt CFM IN H2O db-a Delta STD 9 fan tray 48-10 ~ +55 4000 4.68 225 1600 0.669 75 The max. air flow and the speed are measured in free air; max. air presssure is measured at zero air flow Fan Type: 9 pcs axial fan Communication: I^C Advantage: Soft Start, Over Voltage Protection,Over Current Protection, Fan Speed or Temperature Detect,PWM or Voltage Speed Control, Linear Speed Change, Hot Swappable Function, Thermal Fail or Over Temperature Alarm Signal Output,Redundancy Function,Reverse Polarity Protection,Inrush Current Protection,EEPROM,EMC Delta Fan Tray Capability: Wide Input Voltage Range:10VDC~75VDC Widely Applicative Fan: 12V/24V/48VDC Optimal cooling design of heat dissipation Flexible Manufacture 100% Auto Function Testing 100% Burn In Testing & Monitor Equipment Industry & Telecom (Indoor & outdoor) & Networking and other application ODM & OEM Design Communication: I^C,RS232, RS485 DC/DC Converter Safety Compliance: UL/CUL/TUV/VDE/CE Specificatons are subject to change without notice.

AdvancedTCA AdvancedTCA Fan & Blower Available Air outlet 1 2 3 4 5 6 7 8 9 10 11 12 13 Front Board 14 RTM Air inlet 3D View ATCA 13U (14 Slot) System Controller Boards Delta's fan controllers are designed for the telecom industry. This system cooling solution provides an interface with fan speed control. Features Wide Input Range: 10VDC ~ 75VDC Widely Applicative Fan: 12V/24V/48VDC Soft Start Function at Start Up Reverse Polarity Protection Hot-Swap Inrush Current Protection Function Fail Alarm Indication Redundancy Function Over Voltage and Over Current Protection Thermal Detect and Fan Speed Control PWM or Voltage Control Speed Communication Function: I2C, RS232...etc Custom Design is Accepted Control Functions Fan Speed Alarm Settings Fan Fail Alarm Multiple Fans Fail Alarm Over Temperature or Thermal Fail Alarm Warning for Insufficient Input Power. RPM VS Temperature: Two Modes of Speed Control are Applied. Linear Mode. Step Mode. Fan Tray Production Auto Test Equipment Delta Fan Tray Burn In Monitor System First Layer Temperature( C) Fan 1 Fan 2 Fan 3 Fan 4 Fan 13 Fan 14 Fan 5 Fan 6 Fan 7 Fan 8 Fan 9 Fan 10 Fan 15 Fan 16 Fan 17 Fan 20 Fan 5 Fan 6 Fan 7 Fan 8 Fan 9 Fan 10 Fan 15 Fan 16 Fan 17 Fan 20 Fan 5 Fan 6 Fan 7 Fan 8 Fan 9 Fan 10 Fan 15 Fan 16 Fan 17 Fan 20 Current Test Model Name Signal Type Operation Voltage Fan 11 Fan 12 On /Off Cycle Time Middle Layer Temperature( C) Fan 1 Fan 2 Fan 11 Fan 12 Signal Voltage Fan 3 Fan 4 Fan 13 Fan 14 Accumulate Time Operating Operating Status Records Bottom Layer Temperature( C) Fan 1 Fan 2 Fan 3 Fan 4 Fan 13 Fan 14 Initial Statusds Fan 11 Fan 12 Start Normal Status Signal 1 output Signal 2 output Reset Burn In Monitor Equipment Specificatons are subject to change without notice. Exit Auto Test Machine: Function, Waveform, Inrush Current, LED, Fan Speed Detector, Others

w ww.deltaww.com DELTA ELECTRONICS, INC. 186 RUEY KUANG ROAD, NEIHU, TAIPEI 11491 TAIWAN, REPUBLIC OF CHINA TEL : 886-2-8797-2088 FAX : 886-2-8797-2120 DELTA ELECTRONICS (DONGGUAN) CO., LTD. DELTA INDUSTRIAL ESTATE, SHIJIE TOWN, DONGGUAN, GUANGDONG, PEOPLE'S REPUBLIC OF CHINA POST CODE : 523308 TEL : 86-769-632-9008 FAX : 86-769-663-1589 DELTA ELECTRONICS COMPONENTS (WU JIANG) LTD. 1688 JIANGXING EAST ROAD, WUJIANG ECONOMIC DEVELOPMENT ZONE, WUJIANG CITY,JIANG SU PROVINCE, PEOPLE'S REPUBLIC OF CHINA POST CODE : 215200 TEL : 86-512-6340-1008 FAX : 86-512-6340-1564 DELTA ELECTRONICS (JAPAN), INC. DELTA SHIBADAIMON BUILDING, 2-1-14 SHIBADAIMON, MINATO-KU, TOKYO,105-0012 JAPAN TEL : 81-3-5733-1111 FAX : 81-3-5733-1211 DELTA ELECTRONICS (SINGAPORE) PTE. LTD. 8 KAKI BUKIT ROAD 2, #04-18 RUBY WAREHOUSE COMPLEX, SINGAPORE 417841 TEL : 65-747-5155 FAX : 65-744-9288 DELTA PRODUCTS CORPORATION FREMONT OFFICE 4405 CUSHING PARKWAY, FREMONT, CA 94538, TEL : 1-510-668-5100 FAX : 1-510-668-0680 PORTLAND OFFICE 15125 SW KOLL PARKWAY, SUITE K, BEAVERTON, OR 97006, TEL : 1-503-533-8444 FAX : 1-503-533-0204 LOS ANGELES OFFICE 927 CANADA COURT, CITY OF INDUSTRY, CA 91748, TEL : 1-626-581-8666 FAX : 1-626-581-2186 HOUSTON OFFICE 8270 WILLOW PLACE NORTH, SUITE 150, HOUSTON, TX 77070, TEL : 1-281-477-9400 FAX : 1-281-477-9438 SAN DIEGO OFFICE 17150 VIA DEL CAMPO #303, SAN DIEGO, CA 92127, TEL : 1-858-676-8282 FAX : 1-858-676-0338 RALEIGH OFFICE P.O. BOX 12173, 5101 DAVIS DRIVE, RESEARCH TRIANGLE PARK, NC 27709 TEL : 1-919-767-3800 FAX : 1-919-767-8080 BOSTON OFFICE 175 CABOT STREET, SUITE #310, LOWELL, MA 01854, TEL : 1-978-656-3993 FAX : 1-978-656-3964 AUSTIN OFFICE 575 ROUND ROCK WEST DRIVE, BUILDING K, SUITE#440, ROUNDROCK,TX 78681, TEL : 1-512-671-7749 FAX : 1-512-671-7726 DAKOTA OFFICE 3500 SOUTH LAKEPORT STREET, #H, SIOUX CITY, IA 51106, TEL : 1-712-274-8814 FAX : 1-712-274-8816 DETROIT OFFICE 39201 SCHOOLCRAFT ROAD, SUITE B-9, LIVONIA, MI 48150, TEL : 1-734-464-0068 FAX : 1-734-464-0020 DELTA ELECTRONICS (EUROPE), LTD. AMSTERDAM OFFICE WEGALAAN 16, 2132 JC HOOFDDORP, THE NETHERLANDS TEL : 31-23-566-8989 FAX : 31-23-566-8910 EINDHOVEN OFFICE DE WITBOGT 15, 5652 AG EINDHOVEN, THE NETHERLANDS TEL : 31-40-259-2850 FAX: 31-40-259-2851 GLASGOW OFFICE 1 REDWOOD COURT, PEEL PARK, EAST KILBRIDE, G74 5PF, SCOTLAND, UNITED KINGDOM TEL : 44-1355-588-888 FAX : 44-1355-588-889 SOEST OFFICE COESTERWEG 45, D-59494, SOEST GERMANY TEL : 49 (0) 2921 987 621 FAX : 49 (0) 2921 987 620 DELTA ELECTRONICS (THAILAND) PUBLIC COMPANY LIMITED 111 MOO 9, WELLGROW INDUSTRIAL ESTATE, BANGNA-TRAD ROAD., TAMBON BANGWUA', AMPHUR BANGPAKONG, CHACHOENGSAO 24180, THAILAND TEL : 66-38-522-455 FAX : 66-38-522-477