MRI Case Study MRI Cervical Spine



Similar documents
MRI SureScan Pacing System

Living with Your Pacemaker

Pacemaker Counter and Histogram Operation and Interpretation. Percentage of total count. Figure 2. Detailed ALTRUA Paced and Sensed Event Counters

INSERTABLE CARDIAC MONITORING SYSTEM. UNLOCK the ANSWER. Your heart and long-term monitoring

REVEAL LINQ LNQ11. Insertable Cardiac Monitor MRI procedural information. MRI Technical Manual

IMAGEREADY MR CONDITIONAL DEFIBRILLATION SYSTEM

«Δυσλειτουργία βηματοδότη. Πως μπορούμε να την εκτιμήσουμε στο ιατρείο.» Koσσυβάκης Χάρης Καρδιολογικό Τμήμα Γ.Ν.Α. «Γ. ΓΕΝΝΗΜΑΤΑΣ

What Can I Do about Atrial Fibrillation (AF)?

CareLink Network. Clinic Setup Guide WORKFLOWS. FAQs

What Are Arrhythmias?

Atrial Fibrillation and Cardiac Device Therapy RAKESH LATCHAMSETTY, MD DIVISION OF ELECTROPHYSIOLOGY UNIVERSITY OF MICHIGAN HOSPITAL ANN ARBOR, MI

Introduction. Planned surgical procedures

Tachyarrhythmias (fast heart rhythms)

Diagnosis Code Crosswalk : ICD-9-CM to ICD-10-CM Cardiac Rhythm and Heart Failure Diagnoses

Worldwide Experience with S-ICD: Early results from the EFFORTLESS Registry

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System

DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Medicare & Medicaid Services


Basics of Pacing. Ruth Hickling, RN-BSN Tasha Conley, RN-BSN

COVERAGE GUIDANCE: ABLATION FOR ATRIAL FIBRILLATION

ImageReady MRI Full Body Guidelines for Precision Montage MRI Spinal Cord Stimulator System

CCAD Training Manual. Cardiac Rhythm Management (CRM)

Catheter Ablation. A Guided Approach for Treating Atrial Arrhythmias

Management of Pacing Wires After Cardiac Surgery

REMOTE CARE ALERT MANAGEMENT REFERENCE GUIDE Managing Merlin.net

SW012. Installation software for the Right Ventricular Lead Integrity Alert feature. Reference Manual

WATCHMAN Left Atrial Appendage Closure Device

Automatic External Defibrillators

The science of medicine. The compassion to heal.

Christopher M. Wright, MD, MBA Pioneer Cardiovascular Consultants Tempe, Arizona

Reimbursement Assistance: For Reveal ICM products, please call the Medtronic CRHF Coding Hotline at 1 (866)

New CPT Codes for Cardiac Device Monitoring SIDE-BY-SIDE COMPARISON

Treatments to Restore Normal Rhythm

Treating AF: The Newest Recommendations. CardioCase presentation. Ethel s Case. Wayne Warnica, MD, FACC, FACP, FRCPC

User Manual Table of Contents. Instructions for Using the LaserTouchOne Charging the Unit... 5 Holding the Device... 5 Treatment Steps...

Transforming Healthcare. Transforming Lives. Company Overview

The Emerging Atrial Fibrillation Epidemic: Treat It, Leave It or Burn It?

Transcutaneous Electrical Nerve Stimulation Device LUMI-TENS

Dual Chamber Temporary Pacemaker

Medtronic Cardiac Rhythm and Heart Failure ICD-10 Coding for Physicians

Cook Celect and Günther Tulip Vena Cava Filter Patient Guide

SMRT Student Scope Submission

ACLS Defibrillation Protocols With the ZOLL Rectilinear Biphasic Waveform AHA/ERC Guidelines 2005

VIVA QUAD XT CRT-D DTBA1QQ

PATIENT INFORMATION GUIDE TO ATRIAL FIBRILLATION

GUIDE TO ATRIAL FIBRILLATION

ACLS RHYTHM TEST. 2. A 74-year-old woman with chest pain. Blood pressure 192/90 and rates her pain 9/10.

ICD leads under advisory What should be done?

the basics Perfect Heart Institue, Piyavate Hospital

FDA Guidelines for Magnetic Resonance Equipment Safety

Numerical Modelling of E-M Occupational Exposures associated with MRI

INTRODUCTORY GUIDE TO IDENTIFYING ECG IRREGULARITIES

MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

Vagus Nerve Stimulation (VNS)

Atrioventricular (AV) node ablation

Atrial Fibrillation An update on diagnosis and management

NAME OF THE HOSPITAL: 1. Coronary Balloon Angioplasty: M7F1.1/ Angioplasty with Stent(PTCA with Stent): M7F1.3

Atrial Fibrillation: The heart of the matter

Novartis Gilenya FDO Program Clinical Protocol and Highlights from Prescribing Information (PI)

Electrophysiology Heart Study - EPS -

HTEC 91. Topic for Today: Atrial Rhythms. NSR with PAC. Nonconducted PAC. Nonconducted PAC. Premature Atrial Contractions (PACs)

2010 CPT Codes for Cardiac Device Monitoring

Electrodiagnostic Testing

2015 CPT Codes for Cardiac Device Monitoring

Purpose: To outline the care of patients with permanent or temporary pacemakers.

Atrial Fibrillation The Basics

The Patient s Guide to the Electrophysiologic Study (EPS) and Catheter Ablation

Implantable Cardioverter Defibrillator Therapy

Vagus Nerve Stimulator (VNS)

Potential Causes of Sudden Cardiac Arrest in Children

Patient Guide to Neck Surgery

2013 Medicare Physician Coding and Reimbursement Changes

Medical Procedures and EMI Precautions

Visited 9/14/2011. What is Atrial Fibrillation? What you need to know about Atrial Fibrillation. The Normal Heart Rhythm. 1 of 7 9/14/ :50 AM

Transcutaneous Electrical Nerve Stimulation Device. Operation Manual Read Before Using

Dual Chamber Temporary External Pacemaker

Reimbursement Information For Electrophysiology and Arrhythmia Service Procedures 1

Medical management of CHF: A New Class of Medication. Al Timothy, M.D. Cardiovascular Institute of the South

Atrial Fibrillation (AF) March, 2013

Recurrent AF: Choosing the Right Medication.

Surgeons Role in Atrial Fibrillation

MRI SAFETY JEOPARDY (Technologist Edition) Questions

Cardioversion for. Atrial Fibrillation. Your Heart s Electrical System Cardioversion Living with Atrial Fibrillation

Addendum to the Guideline on antiarrhythmics on atrial fibrillation and atrial flutter

Ngaire has Palpitations

Electrophysiology study (EPS)

Pacers use a 5-letter code: first 3 letters most important

Normal Sinus Rhythm. Sinus Bradycardia. Sinus Tachycardia. Rhythm ECG Characteristics Example (NSR) & consistent. & consistent.

Atrial Fibrillation: Drugs, Ablation, or Benign Neglect. Robert Kennedy, MD October 10, 2015

Atrial & Junctional Dysrhythmias

UCSF Anesthesia Resident Pearls: Cardiac Implantable Electronic Devices: Pacemakers and ICDs Table of Contents

MEDTRONIC CARELINK NETWORK Home monitoring for heart devices. freedom to LIVE LIFE

RAPID INTERPRETATION OF. EKG s

Adult Cardiac Surgery ICD9 to ICD10 Crosswalks

There are only four actions that a patient can take to attempt to correct a monitor error:

Your pacemaker system information

Oxygen - update April 2009 OXG

Introduction to Electrophysiology. Wm. W. Barrington, MD, FACC University of Pittsburgh Medical Center

Transcription:

MRI Case Study MRI Cervical Spine Jewish Hospital Louisville, KY The Revo MRI SureScan pacing system is MR Conditional designed to allow patients to undergo MRI under the specified conditions for use. A complete system, consisting of a Medtronic Revo MRI SureScan IPG implanted with two CapSureFix MRI SureScan leads is required for use in the MRI environment. The results documented in these cases are unique to these patients. Not every patient responds the same. Results may vary. 1 Courtesy of Jewish Hospital, Louisville, KY Nathan Frey, B.S. RT(R)(MR)

Background 41-year-old male Patient symptoms include increase in neck pain, extremity weakness and numbness over the past six months. Revo MRI SureScan pacemaker system implanted 6 months prior. Neurologist requests MRI scan to rule out cervical myelopathy as a cause of symptoms. 2 Courtesy of Jewish Hospital, Louisville, KY Nathan Frey, B.S. RT(R)(MR)

Methods 1.5 Tesla GE MRI scanner Isocenter positioned at nasion for initial localizer. Isocenter positioned superior to C-1 for remaining series. Phased-array spine coil Sequences performed 3-plane Localizer FSE Sagittal T1 and T2 weighted imaging FSE Ax T1, T2, and GRE weighted imaging FSE Sagittal and axial T1 weighted images performed post contrast SureScan mode programmed ON prior to scan 3 Courtesy of Jewish Hospital, Louisville, KY Nathan Frey, B.S. RT(R)(MR)

Methods SAR was kept in Normal mode in order to keep SAR < 2 Watts/Kg. Isocenter was set at the nasion in the scan room for initial 3 plane localizer. FOV for localizer was set to 34 cm. For sagittal imaging, when scanning, FOV was adjusted so the center of the FOV was just superior to C1 with enough coverage inferiorly to include T1. For this patient the FOV was 30 cm. For axial imaging, when scanning, the number of slice locations was increased. The center slice in the stack of images was centered superior to C1 with enough coverage inferiorly to T1. For this patient 72 slices, with center slice 36 centered superior to C1. This increased the overall protocol time approximately 10-15 minutes 4 Courtesy of Jewish Hospital, Louisville, KY Nathan Frey, B.S. RT(R)(MR)

Localizer Isocenter at Nasion 34 cm FOV ISOCENTER 5 Courtesy of Jewish Hospital, Louisville, KY Nathan Frey, B.S. RT(R)(MR)

Sagittal slice coverage with 30 cm FOV ISOCENTER 6 Courtesy of Jewish Hospital, Louisville, KY Nathan Frey, B.S. RT(R)(MR)

Axial increased slice coverage Center slice 36 above C1 ISOCENTER 7 Courtesy of Jewish Hospital, Louisville, KY Nathan Frey, B.S. RT(R)(MR)

Sagittal Images 30 cm FOV ISOCENTER T2 T1 8 Courtesy of Jewish Hospital, Louisville, KY Nathan Frey, B.S. RT(R)(MR)

Axial Images C5/6 - T2 Weighted C5/6 T1 Weighted C5/6 - MERGE 9 Courtesy of Jewish Hospital, Louisville, KY Nathan Frey, B.S. RT(R)(MR)

Diagnostic Results Normal 10 Courtesy of Jewish Hospital, Louisville, KY Nathan Frey, B.S. RT(R)(MR)

Conclusion Positioning of the isocenter superior to C1 with increased Sagittal FOV and Axial slice coverage allowed successful diagnostic imaging of the cervical spine. REMINDER Imaging must be performed within the FDA guidelines for this device, to include both FDA-approved isocenter positioning and SAR limits Revo MRI SureScan mode must be programmed ON prior to scan 11 Courtesy of Jewish Hospital, Louisville, KY Nathan Frey, B.S. RT(R)(MR)

Revo MRI Pacing System Conditions for Use A complete SureScan pacing system including a Revo MRI SureScan IPG and two SureScan leads is required for use in the MRI environment. Any other combination may result in a hazard to the patient during an MRI scan. The SureScan feature must be programmed to On prior to scanning a patient according to the specified conditions for use. Cardiology requirements Patients and their implanted systems must be screened to meet the following requirements: No previously implanted (active or abandoned) medical devices, leads, lead extenders, or lead adaptors No broken leads or leads with intermittent electrical contact, as confirmed by lead impedance history A SureScan pacing system that has been implanted for a minimum of 6 weeks A SureScan pacing system implanted in the left or right pectoral region Pacing capture thresholds of 2.0 volts (V) at a pulse width of 0.4 milliseconds (ms) A lead impedance value of 200 ohms (Ω) and 1,500 Ω No diaphragmatic stimulation at a pacing output of 5.0 V, and at a pulse width of 1.0 ms in patients whose device will be programmed to an asynchronous pacing mode when the MRI SureScan is on Radiology requirements Horizontal, cylindrical bore magnet, clinical MRI systems with a static magnetic field of 1.5 Tesla (T) must be used Gradient systems with maximum gradient slew rate performance per axis of 200 Teslas per meter per second (T/m/s) must be used The scanner must be operated in Normal Operating mode: The whole-body averaged specific absorption rate (SAR) must be 2.0 watts per kilogram (W/kg) The head SAR must be < 3.2 W/kg The patient must be positioned within the bore such that the isocenter (center of the MRI bore) is superior to the C1 vertebra or inferior to the T12 vertebra Proper patient monitoring must be provided during the MRI scan. The methods include visual and verbal contact with the patient, electrocardiography, and pulse oximetry (plethysmography). Training requirements A health professional who has completed cardiology SureScan training must be present during the programming of the SureScan feature A health professional who has completed radiology SureScan training must be present during the MRI scan 12 Courtesy of Jewish Hospital, Louisville, KY Nathan Frey, B.S. RT(R)(MR)

Brief Statement The Revo MRI SureScan pacing system is MR Conditional and as such is designed to allow patients to undergo MRI under the specified conditions for use. Indications The Revo MRI SureScan Model RVDR01 IPG is indicated for use as a system consisting of a Medtronic Revo MRI SureScan IPG implanted with two CapSureFix MRI SureScan 5086MRI leads. A complete system is required for use in the MRI environment. The Revo MRI SureScan Model RVDR01 IPG is indicated for the following: Rate adaptive pacing in patients who may benefit from increased pacing rates concurrent with increases in activity Accepted patient conditions warranting chronic cardiac pacing include: Symptomatic paroxysmal or permanent second- or third-degree AV block Symptomatic bilateral bundle branch block Symptomatic paroxysmal or transient sinus node dysfunctions with or without associated AV conduction disorders Bradycardia-tachycardia syndrome to prevent symptomatic bradycardia or some forms of symptomatic tachyarrhythmias The device is also indicated for dual chamber and atrial tracking modes in patients who may benefit from maintenance of AV synchrony. Dual chamber modes are specifically indicated for treatment of conduction disorders that require restoration of both rate and AV synchrony, which include: Various degrees of AV block to maintain the atrial contribution to cardiac output VVI intolerance (for example, pacemaker syndrome) in the presence of persistent sinus rhythm Antitachycardia Pacing (ATP) is indicated for termination of atrial tachyarrhythmias in bradycardia patients with one or more of the above pacing indications. Atrial rhythm management features such as Atrial Rate Stabilization (ARS), Atrial Preference Pacing (APP), and Post Mode Switch Overdrive Pacing (PMOP) are indicated for the suppression of atrial tachyarrhythmias in bradycardia patients with atrial septal lead placement and one or more of the above pacing indications. Contraindications The device is contraindicated for: Implantation with unipolar pacing leads Concomitant implantation with another bradycardia device Concomitant implantation with an implantable cardioverter defibrillator There are no known contraindications for the use of pacing as a therapeutic modality to control heart rate. The patient s age and medical condition, however, may dictate the particular pacing system, mode of operation, and implantation procedure used by the physician. 13 Courtesy of Jewish Hospital, Louisville, KY Nathan Frey, B.S. RT(R)(MR)

Brief Statement (continued) Rate responsive modes may be contraindicated in those patients who cannot tolerate pacing rates above the programmed Lower Rate Dual chamber sequential pacing is contraindicated in patients with chronic or persistent supraventricular tachycardias, including atrial fibrillation or flutter Single chamber atrial pacing is contraindicated in patients with an AV conduction disturbance ATP therapy is contraindicated in patients with an accessory antegrade pathway Warnings and Precautions Changes in patient s disease and/or medications may alter the efficacy of the device s programmed parameters. Patients should avoid sources of magnetic and electromagnetic radiation to avoid possible underdetection, inappropriate sensing and/or therapy delivery, tissue damage, induction of an arrhythmia, device electrical reset, or device damage. Do not place transthoracic defibrillation paddles directly over the device. Use of the device should not change the application of established anticoagulation protocols. Patients and their implanted systems must be screened to meet the MRI Conditions of Use. Do not scan patients who do not have a complete Revo MRI SureScan pacing system consisting of a SureScan device and two SureScan leads; patients who have previously implanted devices, or broken or intermittent leads; or patients who have a lead impedance value of < 200 Ω or > 1,500 Ω. Do not scan patients with a SureScan pacing system implanted in sites other than the left and right pectoral region; or patients positioned such that the isocenter (center of MRI bore) is inferior to C1 vertebra and superior to the T12 vertebra. Potential Complications Potential complications include, but are not limited to, rejection phenomena, erosion through the skin, muscle or nerve stimulation, oversensing, failure to detect and/or terminate arrhythmia episodes, acceleration of tachycardia, and surgical complications such as hematoma, infection, inflammation, and thrombosis. Potential lead complications include, but are not limited to, valve damage, fibrillation, thrombosis, thrombotic and air embolism, cardiac perforation, heart wall rupture, cardiac tamponade, pericardial rub, infection, myocardial irritability, and pneumothorax. Other potential complications related to the lead may include lead dislodgement, lead conductor fracture, insulation failure, threshold elevation, or exit block. The SureScan system has been designed to minimize potential complications in the MRI environment. Potential MRI complications include, but are not limited to, lead electrode and/or device heating which may cause tissue damage, impact the pacing system functionality such as failure to detect/treat irregular heartbeats, or potential for VT/VF induction. See the device manuals before performing an MRI Scan for detailed information regarding the implant procedure, indications, MRI conditions of use, contraindications, warnings, precautions, and potential complications/adverse events. For further information, call Medtronic at 1 (800) 328-2518 and/or consult Medtronic s website at www.medtronic.com. Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. 14 Courtesy of Jewish Hospital, Louisville, KY Nathan Frey, B.S. RT(R)(MR)

www.medtronic.com World Headquarters Medtronic, Inc. 710 Medtronic Parkway Minneapolis, MN 55432-5604 USA Tel: (763) 514-4000 Fax: (763) 514-4879 Medtronic USA, Inc. Toll-free: 1 (800) 328-2518 (24-hour technical support for physicians and medical professionals) UC201300138a EN Medtronic, Inc. 2012. All Rights Reserved. 07/2012 15 Courtesy of Jewish Hospital, Louisville, KY Nathan Frey, B.S. RT(R)(MR)