1 New CPT Codes for Cardiac Device Monitoring SIDE-BY-SIDE COMPARISON Effective January 1, 2009
2 NEW CPT 1 CODES FOR CARDIAC DEVICE MONITORING Twenty-three new CPT codes for Cardiac Device Monitoring were created by the American Medical Association in 2008 at the request of the American College of Cardiology and the Heart Rhythm Society. This booklet includes descriptive information on these new CPT codes which become effective January 1, This is not a comprehensive list of all new CPT codes and it is possible that there is a more appropriate code for any given procedure. Pages 3-9 provide a side-by-side comparison of the 2008 and 2009 CPT codes. Boldface type is used to highlight key words, providing a quick reference. A detailed listing of the 2008 CPT codes that will be deleted effective January 1, 2009 is on page 13. CPT code descriptor revisions that are effective January 1, 2009, such as external (wearable) electrocardiographic monitoring, are on page 14. The CPT code set has been developed as stand-alone descriptions of medical procedures. Some CPT procedure codes are not printed in their entirety but instead refer back to the common portion of the procedure listed in a preceding entry. This is apparent when an entry is followed by one or more indentations. Here is an example: 93279: Programming device evaluation with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with physician analysis, review and report; single lead pacemaker system 93280: dual lead pacemaker system These new cardiac device monitoring codes (pages 11-12): better describe services associated with implantable cardiac devices and recognize advances in cardiac monitoring technologies distinguish between a programming and an interrogation evaluation, in person or remote, as well as codes for multiple lead (more than two) device evaluations describe the work associated with assessment and programming of an implanted cardiac device pre- and post-procedure, surgery, or test report physiologic monitoring such as intrathoracic impedance, left atrial pressure, and weight and blood pressure obtained from internal and/or external sensors describe services associated with wearable mobile cardiovascular telemetry For questions or for more information, please contact Medtronic at 1 (866) , option 1. Cardiac Rhythm Disease Management (CRDM) reimbursement customer information is available at CPT copyright 2008 American Medical Association. All rights reserved. 1
3 Additional Coding Information: Medtronic has prepared this document to reflect the current information provided in the Display Copy of the 2009 Final Rule for the Medicare Physician Fee Schedule. 2 It is important to refer to the new CPT code descriptions in order to ensure that a billed code meets the specific requirements defined for each individual code. Any time new procedure codes are implemented, there may be some ambiguity as to exact usage guidelines and/or applicability to very specific individual scenarios. You should contact your local contractor/payer for interpretation of applicable policies. Medtronic may periodically post updated versions of this document on its reimbursement website 3 as additional information becomes available. These new CPT codes were developed to more accurately reflect current cardiac device monitoring capabilities, long distance telemetry and remote interrogation network systems, and follow-up practices. Some of these new code sets are structured differently than the CPT codes that they replace. Specifically, the new codes for remote monitoring do not have separate professional (-26) and technical s (-TC) applied to an individual code. Instead, the new remote monitoring codes have separate CPT codes that represent the professional and technical s. The new device programming codes are generally defined by the number of leads, rather than the type of generator. Also, the period of time included in the specific type of service is indicated as per encounter, 30 or 90 days. There are two new peri-procedural device evaluation and programming codes: for pacemakers and for ICDs. These codes are used when performing an evaluation of an implantable device system to adjust the device settings appropriate for the patient prior to a surgery, procedure, or test. The device system data are interrogated to evaluate the lead(s), sensor(s), and battery in addition to review of stored information, including patient and system measurements. The device is programmed to settings appropriate for the surgery, procedure, or test, as required. A second evaluation and programming are performed after the surgery, procedure, or test to provide settings appropriate to the post-procedural situation, as required. Each instance of either pre- or post-evaluation and programming services may be reported. For CPT codes other than for remote monitoring, the Global CPT codes comprise the Professional and Technical Components. If both s of care are rendered, it is not necessary to append a modifier to the code. However, the remote monitoring codes are an example of a global service that requires two different CPT codes to be billed together as one code represents the Professional Service and another code represents the Technical Service (e.g., CPT & 93296, & 93296, & 93299, & 93299). The Professional Component reflects physician time and intensity in furnishing the service, including activities before and after direct patient contact. 4 When only the professional is performed, modifier 26 should be added to the appropriate CPT code to identify the service. The -26 modifier would not be appended if the code represents only the professional services of the CPT code description (e.g., CPT 93294, 93295, 93297, 93298). The Technical Component refers to the resources used in furnishing the service, such as office rent, wages of personnel, and other office practice expenses. When only the technical is performed, the modifier TC 5 should be added to the appropriate CPT code to identify the service. The -TC modifier would not be appended if the code represents only the technical support and services of the CPT code description (e.g., CPT 93296, 93299). Physician Supervision Requirements Medicare established specific diagnostic test supervision requirements applicable to the technical of the electronic analysis of implanted cardiac devices. 6 Medicare requires: General supervision of the technical service for remote pacemaker and ICD interrogations (codes 93296, 93299) Direct supervision of the technical for in person cardiac device interrogations Direct supervision for the technical of a transtelephonic pacemaker evaluation NOTE: Medicare specifies direct supervision for the professional service of a remote pacemaker interrogation (CPT 93294). Please contact your Medicare contractor to seek clarification on the difference in supervision requirements between this code and other device evaluation professional services. These supervision requirements are in addition to any other Medicare coverage requirements. The Medicare supervision requirements for individual CPT codes are available on the Physician Fee Schedule Lookup function on the Medicare website 7 or under PFS Relative Value Files for General supervision 9 means the procedure is furnished under the physician s overall direction and control, but the physician s presence is not required during the performance of the procedure. Under general supervision, the training of the non-physician personnel who actually performs the diagnostic procedure and the maintenance of the necessary equipment and supplies are the continuing responsibility of the physician. Direct supervision 9 means the physician must be present in the office suite and immediately available to furnish assistance and direction throughout the performance of the procedure. It does not mean that the physician must be present in the room when the procedure is performed. The Heart Rhythm Society (HRS) has recently released a document that represents their consensus statement on the role of manufacturers representatives in the care of patients with heart rhythm disorders. This policy statement also contains HRS perspective on appropriate delivery of and billing for the technical of services associated with cardiac devices. 10 We encourage providers to seek confirmation or clarification from the payer about the policy statement. These coding suggestions do not replace seeking coding advice from the payer and/or your own coding staff. The ultimate responsibility for correct coding lies with the provider of services. Please contact your local payer for interpretation of the appropriate codes to use for specific procedures. Medtronic makes no guarantee that the use of this information will prevent differences of opinion or disputes with Medicare or other third party payers as to the correct form of billing or the amount that will be paid to providers of service. For questions or for more information, please contact Medtronic at 1 (866) , option 1. Cardiac Rhythm Disease Management (CRDM) reimbursement customer information is available at: 2
4 New CPT Codes for Cardiac Device Monitoring Effective January 1, 2009 Category 2008 CPT Code 2008 CPT Code Description 2009 CPT Code 2009 CPT Code Description Time Period Other Information IMPLANTABLE PACEMAKER Pacemaker In Person 93731, TC 6 or , TC or , TC or Electronic analysis of dual chamber pacemaker system (includes evaluation of programmable parameters at rest and without reprogramming Electronic analysis of single chamber pacemaker system (includes evaluation of programmable parameters at rest and without reprogramming with reprogramming 93288, TC or , TC or Interrogation device evaluation (in person) with physician analysis, review and report, includes connection, recording and disconnection per patient encounter; single, dual, or multiple lead pacemaker system (Do not report in conjunction with , 93286, 93294, 93296) Programming device evaluation with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with physician analysis, review and report; single lead pacemaker system (Do not report in conjunction with 93286, 93288) per encounter 93732, TC or Electronic analysis of dual chamber pacemaker system (includes evaluation of programmable parameters at rest and with reprogramming 93280, TC or , TC or dual lead pacemaker system (Do not report in conjunction with 93286, 93288) multiple lead pacemaker system (Do not report in conjunction with 93286, 93288) For example, three lead biventricular pacemaker 3
5 Pacemaker Remote TC TC Electronic analysis of dual chamber pacemaker system (includes evaluation of programmable parameters at rest and without reprogramming Electronic analysis of single chamber pacemaker system (includes evaluation of programmable parameters at rest and without reprogramming Interrogation device evaluation(s), (remote), up to 90 days; single, dual, or multiple lead pacemaker system or implantable cardioverter-defibrillator system, remote data acquisition(s), receipt of transmissions and technician review, technical support and distribution of results (Do not report in conjunction with 93288, 93289, 93299) (Report only once per 90 days) represents the technical Electronic analysis of dual chamber pacemaker system (includes evaluation of programmable parameters at rest and without reprogramming Electronic analysis of single chamber pacemaker system (includes evaluation of programmable parameters at rest and without reprogramming Interrogation device evaluation(s) (remote), up to 90 days; single, dual, or multiple lead pacemaker system with interim physician analysis, review(s) and report(s) (Do not report in conjunction with 93288, 93293) (Report only once per 90 days) per 90 days represents the professional or CPT code descriptions referenced above and CPT code descriptions referenced above Pacemaker Remote Interrogation Device Evaluation Global 6 Pacemaker Transtelephonic Monitoring 93733, TC or , TC or Electronic analysis of dual chamber internal pacemaker system (may include rate, pulse amplitude and duration, configuration of wave form, and/or testing of sensory function of pacemaker), telephonic analysis Electronic analysis of single chamber internal pacemaker system (may include rate, pulse amplitude and duration, configuration of wave form, and/or testing of sensory function of pacemaker), telephonic analysis 93293, TC or Transtelephonic rhythm strip pacemaker evaluation(s) single, dual, or multiple lead pacemaker system, includes recording with and without magnet application with physician analysis, review and report(s), up to 90 days (Do not report in conjunction with 93294) (For in person evaluation, see 93040, 93041, 93042) (Report only once per 90 days) per 90 days 4
6 Category 2008 CPT Code 2008 CPT Code Description 2009 CPT Code 2009 CPT Code Description Time Period Other Information IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR Defibrillator In Person 93741, TC or , TC or Electronic analysis of pacing cardioverter-defibrillator (includes interrogation, evaluation of pulse generator status, evaluation of programmable parameters at rest and single chamber or wearable cardioverter-defibrillator system, without reprogramming dual chamber, without reprogramming 93289, TC or Interrogation device evaluation (in person) with physician analysis, review and report, includes connection, recording and disconnection per patient encounter; single, dual, or multiple lead implantable cardioverter-defibrillator system, including analysis of heart rhythm derived data elements (For monitoring physiologic cardiovascular data elements derived from an ICD, use 93290) (Do not report in conjunction with , 93287, 93295, 93296) 93742, TC or single chamber or wearable cardioverter-defibrillator system, with reprogramming 93282, TC or Programming device evaluation with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with physician analysis, review and report; single lead implantable cardioverter-defibrillator system (Do not report in conjunction with 93287, 93289, 93745) per encounter 93744, TC or dual chamber, with reprogramming 93283, TC or , TC or dual lead implantable cardioverter-defibrillator system (Do not report in conjunction with 93287, 93289) multiple lead implantable cardioverter-defibrillator system (Do not report in conjunction with 93287, 93289) For example, three lead biventricular defibrillator Defibrillator Remote TC Electronic analysis of pacing cardioverter-defibrillator (includes interrogation, evaluation of pulse generator status, evaluation of programmable parameters at rest and single chamber or wearable cardioverter-defibrillator system, without reprogramming TC dual chamber, without reprogramming Interrogation device evaluation(s) (remote), up to 90 days; single, dual, or multiple lead pacemaker system or implantable cardioverter-defibrillator system, remote data acquisition(s), receipt of transmissions and technician review, technical support and distribution of results (Do not report in conjunction with 93288, 93289, 93299) (Report only once per 90 days) per 90 days represents the technical 5
7 single chamber or wearable cardioverter-defibrillator system, without reprogramming dual chamber, without reprogramming Interrogation device evaluation(s) (remote), up to 90 days; single, dual, or multiple lead implantable cardioverterdefibrillator system with interim physician analysis, review(s) and report(s) (For remote monitoring of physiologic cardiovascular data elements derived from an ICD, use 93297) (Do not report in conjunction with 93289) (Report only once per 90 days) represents the professional or CPT code descriptions referenced above and CPT code descriptions referenced above Defibrillator Remote Interrogation Device Evaluation Global 6 IMPLANTABLE CARDIOVASCULAR MONITOR (ICM) AND IMPLANTABLE LOOP RECORDER (ILR) Implantable Cardiovascular Monitor (ICM) In Person None Not Applicable 93290, TC or Interrogation device evaluation (in person) with physician analysis, review and report, includes connection, recording and disconnection per patient encounter; implantable cardiovascular monitor system, including analysis of 1 or more recorded physiologic cardiovascular data elements from all internal and external sensors per encounter (For heart rhythm derived data elements, use 93289) (Do not report in conjunction with 93297, 93299) Implantable Cardiovascular Monitor (ICM) Remote Interrogation device evaluation(s), (remote) up to 30 days; implantable cardiovascular monitor system, including analysis of 1 or more recorded physiologic cardiovascular data elements from all internal and external sensors, physician analysis, review(s) and report(s) (For heart rhythm derived data elements, use 93295) (Do not report in conjunction with 93290, 93298) represents the professional of ICM (Report only once per 30 days) None Not Applicable implantable cardiovascular monitor system or implantable loop recorder system, remote data acquisition(s), receipt of transmissions and technician review, technical support and distribution of results (Do not report in conjunction with 93290, 93291, 93296) per 30 days represents the technical of ICM (Report only once per 30 days) and CPT code descriptions referenced above ICM Remote Interrogation Device Evaluation Global 6 6
8 Category 2008 CPT Code 2008 CPT Code Description 2009 CPT Code 2009 CPT Code Description Time Period IMPLANTABLE CARDIOVASCULAR MONITOR (ICM) AND IMPLANTABLE LOOP RECORDER (ILR) (continued) Other Information Implantable Loop Recorder (ILR) In Person Electronic analysis of implantable loop recorder (ILR) system (includes retrieval of recorded and stored ECG data, physician review and interpretation of retrieved ECG data and reprogramming) 93291, TC or , TC or Interrogation device evaluation (in person) with physician analysis, review and report, includes connection, recording and disconnection per patient encounter; implantable loop recorder system, including heart rhythm derived data analysis (Do not report in conjunction with 33282, , 93298, 93299) per Programming device evaluation with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with physician analysis, review and report; implantable loop recorder system (Do not report in conjunction with 33282, 93279, 93284, 93291) encounter Implantable Loop Recorder (ILR) Remote Interrogation device evaluation(s), (remote) up to 30 days; implantable loop recorder system, including analysis of recorded heart rhythm data, physician analysis, review(s) and report(s) (Do not report in conjunction with 93291, 93297) (Report only once per 30 days) represents the professional of ILR None Not Applicable implantable cardiovascular monitor system or implantable loop recorder system, remote data acquisition(s), receipt of transmissions and technician review, technical support and distribution of results (Do not report in conjunction with 93290, 93291, 93296) (Report only once per 30 days) per 30 days represents the technical of ILR and CPT code descriptions referenced above ILR Remote Interrogation Device Evaluation Global 6 7
9 PERI-PROCEDURAL Peri-Procedural In Person Only None Not Applicable 93286, TC or , TC or Peri-procedural device evaluation and programming of device system parameters before or after a surgery, procedure, or test with physician analysis, review and report; single, dual, or multiple lead pacemaker system (Report once before and once after surgery, procedure, or test, when device evaluation and programming is performed before and after surgery, procedure, or test) (Do not report in conjunction with , 93288) single, dual, or multiple lead implantable cardioverter-defibrillator system (Report once before and once after surgery, procedure, or test, when device evaluation and programming is performed before and after surgery, procedure, or test) (Do not report in conjunction with , 93289) per encounter WEARABLE Mobile Cardiovascular Telemetry Unlisted cardiovascular service or procedure Wearable mobile cardiovascular telemetry with electrocardiographic recording, concurrent computerized real time data analysis and greater than 24 hours of accessible ECG data storage (retrievable with query) with ECG triggered and patient selected events transmitted to a remote attended surveillance center for up to 30 days; physician review and interpretation with report per 30 days represents the professional (Report only once per 30 days) (Do not report in conjunction with 93014) Unlisted cardiovascular service or procedure technical support for connection and patient instructions for use, attended surveillance, analysis and physician prescribed transmission of daily and emergent data reports (Report only once per 30 days) (Do not report in conjunction with 93014) (For wearable cardiovascular monitors that do not perform automatic ECG triggered transmissions to an attended surveillance center, see , ) per 30 days represents the technical 8
10 Category 2008 CPT Code 2008 CPT Code Description 2009 CPT Code 2009 CPT Code Description Time Period Other Information WEARABLE (continued) Wearable Cardioverter-Defibrillator Initial set-up and programming by a physician of wearable cardioverter-defibrillator includes initial programming of system, establishing baseline electronic ECG, transmission of data to data repository, patient instruction in wearing system and patient reporting of problems or events Initial set-up and programming by a physician of wearable cardioverter-defibrillator includes initial programming of system, establishing baseline electronic ECG, transmission of data to data repository, patient instruction in wearing system and patient reporting of problems or events (Do not report in conjunction with 93282, 93292) 93741, TC or , TC or Electronic analysis of pacing cardioverter-defibrillator (includes interrogation, evaluation of pulse generator status, evaluation of programmable parameters at rest and single chamber or wearable cardioverter-defibrillator system, without reprogramming single chamber or wearable cardioverter-defibrillator system, with reprogramming 93292, TC or Interrogation device evaluation (in person) with physician analysis, review and report, includes connection, recording and disconnection per patient encounter; wearable defibrillator system (Do not report in conjunction with 93745) per encounter 9
11 NOTES 10
12 The following CPT codes are effective for services provided on and after January 1, 2009: 93228: Wearable mobile cardiovascular telemetry with electrocardiographic recording, concurrent computerized real time data analysis and greater than 24 hours of accessible ECG data storage (retrievable with query) with ECG triggered and patient selected events transmitted to a remote attended surveillance center for up to 30 days; physician review and interpretation with report 93229: Wearable mobile cardiovascular telemetry with electrocardiographic recording, concurrent computerized real time data analysis and greater than 24 hours of accessible ECG data storage (retrievable with query) with ECG triggered and patient selected events transmitted to a remote attended surveillance center for up to 30 days; technical support for connection and patient instructions for use, attended surveillance, analysis and physician prescribed transmission of daily and emergent data reports 93279: Programming device evaluation with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with physician analysis, review and report; single lead pacemaker system 93280: Programming device evaluation with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with physician analysis, review and report; dual lead pacemaker system 93281: Programming device evaluation with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with physician analysis, review and report; multiple lead pacemaker system 93282: Programming device evaluation with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with physician analysis, review and report; single lead implantable cardioverter-defibrillator system 93283: Programming device evaluation with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with physician analysis, review and report; dual lead implantable cardioverter-defibrillator system 93284: Programming device evaluation with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with physician analysis, review and report; multiple lead implantable cardioverter-defibrillator system 93285: Programming device evaluation with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with physician analysis, review and report; implantable loop recorder system 93286: Peri-procedural device evaluation and programming of device system parameters before or after a surgery, procedure, or test with physician analysis, review and report; single, dual, or multiple lead pacemaker system 93287: Peri-procedural device evaluation and programming of device system parameters before or after a surgery, procedure, or test with physician analysis, review and report; single, dual, or multiple lead implantable cardioverter-defibrillator system 93288: Interrogation device evaluation (in person) with physician analysis, review and report, includes connection, recording and disconnection per patient encounter; single, dual, or multiple lead pacemaker system 93289: Interrogation device evaluation (in person) with physician analysis, review and report, includes connection, recording and disconnection per patient encounter; single, dual, or multiple lead implantable cardioverter-defibrillator system, including analysis of heart rhythm derived data elements 11
13 93290: Interrogation device evaluation (in person) with physician analysis, review and report, includes connection, recording and disconnection per patient encounter; implantable cardiovascular monitor system, including analysis of 1 or more recorded physiologic cardiovascular data elements from all internal and external sensors 93291: Interrogation device evaluation (in person) with physician analysis, review and report, includes connection, recording and disconnection per patient encounter; implantable loop recorder system, including heart rhythm derived data analysis 93292: Interrogation device evaluation (in person) with physician analysis, review and report, includes connection, recording and disconnection per patient encounter; wearable defibrillator system 93293: Transtelephonic rhythm strip pacemaker evaluation(s) single, dual, or multiple lead pacemaker system, includes recording with and without magnet application with report(s), up to 90 days 93294: Interrogation device evaluation(s) (remote), up to 90 days; single, dual, or multiple lead pacemaker system with interim physician analysis and physician review and report(s) 93295: Interrogation device evaluation(s) (remote), up to 90 days; single, dual, or multiple lead implantable cardioverter-defibrillator system with interim physician analysis and physician review(s) and report(s) 93296: Interrogation device evaluation(s), (remote), up to 90 days; single, dual, or multiple lead pacemaker system or implantable cardioverter-defibrillator system, remote data acquisition(s), receipt of transmissions and technician review, technical support and distribution of results 93297: Interrogation device evaluation(s), (remote) up to 30 days; implantable cardiovascular monitor system, including analysis of 1 or more recorded physiologic cardiovascular data elements from all internal and external sensors, physician analysis, review(s) and report(s) 93298: Interrogation device evaluation(s), (remote) up to 30 days; implantable loop recorder system, including analysis of recorded heart rhythm data, physician analysis, review(s) and report(s) 93299: Interrogation device evaluation(s), (remote) up to 30 days; implantable cardiovascular monitor system or implantable loop recorder system, remote data acquisition(s), receipt of transmissions and technician review, technical support and distribution of results 12
14 The following CPT codes will be deleted as of January 1, 2009: 93727: Electronic analysis of implantable loop recorder (ILR) system (includes retrieval of recorded and stored ECG data, physician review and interpretation of retrieved ECG data and reprogramming) 93731: Electronic analysis of dual-chamber pacemaker system (includes evaluation of programmable parameters at rest and during activity where applicable, using electrocardiographic without reprogramming 93732: Electronic analysis of dual-chamber pacemaker system (includes evaluation of programmable parameters at rest and during activity where applicable, using electrocardiographic with reprogramming 93733: Electronic analysis of dual chamber internal pacemaker system (may include rate, pulse amplitude and duration, configuration of wave form, and/or testing of sensory function of pacemaker), telephonic analysis 93734: Electronic analysis of single chamber pacemaker system (includes evaluation of programmable parameters at rest and during activity where applicable, using electrocardiographic without reprogramming 93735: Electronic analysis of single chamber pacemaker system (includes evaluation of programmable parameters at rest and during activity where applicable, using electrocardiographic with reprogramming 93736: Electronic analysis of single chamber internal pacemaker system (may include rate, pulse amplitude and duration, configuration of wave form, and/or testing of sensory function of pacemaker), telephonic analysis 93741: Electronic analysis of pacing cardioverter-defibrillator (includes interrogation, evaluation of pulse generator status, evaluation of programmable parameters at rest and exercise, analysis of event markers and device response); single chamber or wearable cardioverter-defibrillator system, without reprogramming 93742: E lectronic analysis of pacing cardioverter-defibrillator (includes interrogation, evaluation of pulse generator status, evaluation of programmable parameters at rest and exercise, analysis of event markers and device response); single chamber or wearable cardioverter-defibrillator system, with reprogramming 93743: Electronic analysis of pacing cardioverter-defibrillator (includes interrogation, evaluation of pulse generator status, evaluation of programmable parameters at rest and exercise, analysis of event markers and device response); dual chamber, without reprogramming 93744: Electronic analysis of pacing cardioverter-defibrillator (includes interrogation, evaluation of pulse generator status, evaluation of programmable parameters at rest and exercise, analysis of event markers and device response); dual chamber, with reprogramming 13
15 CPT codes with description revisions as of January 1, 2009: 93224: Wearable E electrocardiographic rhythm derived monitoring for 24 hours by continuous original ECG waveform recording and storage, with visual superimposition scanning; includes recording, scanning analysis with report, physician review, and interpretation 93225: Wearable E electrocardiographic rhythm derived monitoring for 24 hours by continuous original ECG waveform recording and storage, with visual superimposition scanning; recording (includes connection hook-up, recording, and disconnection) 93226: Wearable E electrocardiographic rhythm derived monitoring for 24 hours by continuous original ECG waveform recording and storage, with visual superimposition scanning; scanning analysis with report 93227: Wearable E electrocardiographic rhythm derived monitoring for 24 hours by continuous original ECG waveform recording and storage, with visual superimposition scanning; physician review and interpretation 93230: Wearable E electrocardiographic rhythm derived monitoring for 24 hours by continuous original ECG waveform recording and storage without superimposition scanning utilizing a device capable of producing a full miniaturized printout; includes recording, microprocessor-based analysis with report, physician review and interpretation 93231: Wearable E electrocardiographic rhythm derived monitoring for 24 hours by continuous original ECG waveform recording and storage without superimposition scanning utilizing a device capable of producing a full miniaturized printout; recording (includes connection hook-up, recording, and disconnection) 93232: Wearable E electrocardiographic rhythm derived monitoring for 24 hours by continuous original ECG waveform recording and storage without superimposition scanning utilizing a device capable of producing a full miniaturized printout; microprocessor-based analysis with report 93233: Wearable E electrocardiographic rhythm derived monitoring for 24 hours by continuous original ECG waveform recording and storage without superimposition scanning utilizing a device capable of producing a full miniaturized printout; physician review and interpretation 14
16 References 1 CPT copyright 2008 American Medical Association. All rights reserved. CPT is a registered trademark of the American Medical Association Social Security Act Section 1848(c) (1) (A) and (B). 5 Section (b) of the Code of Federal Regulations (CFR). 6 pages Medicare s website is: Medicare Benefit Policy Manual, CMS-Pub , Chapter 15, Lindsay BD, Estes NA III, Maloney JD, Reynolds DW. Heart Rhythm Society Policy Statement Update: Recommendations on the Role of Industry Employed Allied Professionals (IEAPs). Heart Rhythm. November 2008;5(11):e Modifier 26: Professional Component, per the American Medical Association. 12 CMS-Pub : Medicare Claims Processing. Transmittal 979, Change Request 5048, June 9, This transmittal can be found at World Headquarters Medtronic, Inc. 710 Medtronic Parkway Minneapolis, MN USA Tel: (763) Fax: (763) Medtronic USA, Inc. Toll-free: 1 (800) (24-hour technical support for physicians and medical professionals) UC EN Medtronic, Inc Minneapolis, MN. All Rights Reserved. Printed in USA. 11/2008
2010 CPT Codes for Cardiac Device Monitoring
2010 CPT Codes for Cardiac Device Monitoring CPT copyright 2009. American Medical Association. All rights reserved. CPT is a registered trademark of the American Medical Association. CPT Code IMPLANTABLE
More information2015 CPT Codes for Cardiac Device Monitoring
2015 CPT Codes for Cardiac Device Monitoring CPT 1 copyright 2014. American Medical Association. All rights reserved. CPT is a registered trademark of the American Medical Association. CPT Code IMPLANTABLE
More information2015 ST. JUDE MEDICAL THERAPY CODING GUIDE
2015 ST. JUDE MEDICAL THERAPY CODING GUIDE Physician Coding for Cardiac Device Monitoring This guide provides physician information for cardiac device monitoring. In addition, St. Jude Medical offers a
More informationCardiac Device Monitoring
Cardiac Device Monitoring» PHYSICIAN REIMBURSEMENT GUIDE EFFECTIVE JANUARY 1, 2014 2 Contents Page Introduction Medicare Coding and Payment Overview Physician Fee Schedule Coverage for Device Monitoring
More informationReimbursement Information For Electrophysiology and Arrhythmia Service Procedures 1
GE Healthcare Information For Electrophysiology and Arrhythmia Procedures 1 2011 Update www.gehealthcare.com/reimbursement This overview addresses coding, coverage, and payment for electrophysiology procedures
More information2013 Medicare Physician Coding and Reimbursement Changes
2013 Medicare Physician Coding and Reimbursement Changes Disclaimer This presentation is intended for educational use. Any duplication is prohibited without written consent of Medtronic s Economic Strategies
More informationConnecting Cardiac Device Data and the EHR
Learn More Interested in learning more about how Paceart s device management functionality can work in an EHR environment and help you in your move toward the paperless transfer of data? Connecting Cardiac
More informationConnecting Cardiac Device Data and the EHR
Connecting Cardiac Device Data and the EHR Introduction In an age of complex information needs, healthcare providers often use a staggering variety of applications to capture a patient s complete clinical
More informationTABLE OF CONTENTS. 1 From Cleveland Clinic, Cleveland, Ohio, 2 Fondazione Cardiocentro Ticino, Lugano, Switzerland, 3 Thorax
HRS/EHRA Expert Consensus on the Monitoring of Cardiovascular Implantable Electronic Devices (CIEDs): Description of Techniques, Indications, Personnel, Frequency and Ethical Considerations Developed in
More informationPreamble. Europace (2008) 10, 707 725 doi:10.1093/europace/eun122
Europace (2008) 10, 707 725 doi:10.1093/europace/eun122 HRS/EHRA Expert Consensus on the Monitoring of Cardiovascular Implantable Electronic Devices (CIEDs): Description of Techniques, Indications, Personnel,
More informationEstablishing a Remote Monitoring Program. Martha Ferrara, FNP
Establishing a Remote Monitoring Program Martha Ferrara, FNP Establishing a Remote Monitoring Program What is Remote Monitoring? Martha Ferrara, FNP, CCDS November 2012 CIED Timeline: Cardiovascular Implantable
More informationLocal Coverage Article: Cardiovascular Stress Testing (A53123)
Local Coverage Article: Cardiovascular Stress Testing (A53123) Contractor Information Contractor Name Novitas Solutions, Inc. Article Information General Information Article ID A53123 Original ICD-9 Article
More informationReporting of Devices and Leads When a Credit is Received
Reporting of Devices and Leads When a Credit is Received Cardiac Rhythm Management and Electrophysiology Updated January 2014 Medicare Reporting Requirements For Full or Partial Credits of Devices and
More informationMEDTRONIC CARELINK NETWORK Home monitoring for heart devices. freedom to LIVE LIFE
MEDTRONIC CARELINK NETWORK Home monitoring for heart devices freedom to LIVE LIFE Before CareLink Monitoring, I was concerned about traveling far from home and my clinic. Having the monitor with me, knowing
More informationLiving with Your Pacemaker
Brief Statement Additional Device Information An implantable pacemaker system relieves symptoms of heart rhythm disturbances. They do this by restoring normal heart rates. A normal heart rate provides
More informationUnitedHealthcare, UnitedHealthcare of the River Valley and Neighborhood Health Partnership Cardiology Notification and Prior Authorization Program:
UnitedHealthcare, UnitedHealthcare of the River Valley and Neighborhood Health Partnership Cardiology Notification and Prior Authorization Program: Electrophysiology Implant Code Classification Table The
More informationHow To Run A Pacemar Optima System On A Microsoft Powerbook 2.5 (Powerbook) With A Powerbook 1.5 And Powerbook 3.5 On A Pc Or Macbook 2 (Powerstation) With An
Paceart Optima System Technical Requirements This document details the hardware and software requirements for the Paceart Optima System. Performance of the Paceart System may be impacted if these requirements
More informationSpecific Basic Standards for Osteopathic Fellowship Training in Cardiology
Specific Basic Standards for Osteopathic Fellowship Training in Cardiology American Osteopathic Association and American College of Osteopathic Internists BOT 07/2006 Rev. BOT 03/2009 Rev. BOT 07/2011
More informationLocal Coverage Determination (LCD): Electrocardiographic (EKG or ECG) Monitoring (Holter or Real-Time Monitoring) (L29584)
Local Coverage Determination (LCD): Electrocardiographic (EKG or ECG) Monitoring (Holter or Real-Time Monitoring) (L29584) Contractor Information Contractor Name Wisconsin Physicians Service Insurance
More informationWhat Can I Do about Atrial Fibrillation (AF)?
Additional Device Information 9529 Reveal XT Insertable Cardiac Monitor The Reveal XT Insertable Cardiac Monitor is an implantable patientactivated and automatically activated monitoring system that records
More informationINSERTABLE CARDIAC MONITORING SYSTEM. UNLOCK the ANSWER. Your heart and long-term monitoring
INSERTABLE CARDIAC MONITORING SYSTEM UNLOCK the ANSWER Your heart and long-term monitoring UNLOCK the ANSWER Irregular heartbeats can be related to a variety of conditions, including unexplained fainting,
More informationGE Healthcare. The ECG with more knowledge built in Introducing the MAC * 5500 HD
GE Healthcare The ECG with more knowledge built in Introducing the MAC * 5500 HD If you can t see the pacemaker, you re not seeing the whole patient During a patient s cardiac event, physicians have moments
More informationGuidelines for Perioperative Management of Pacemakers and Defibrillators
Guidelines for Perioperative Management of Pacemakers and Defibrillators Developed By: Deborah Wolbrette, MD, Medical Director, Electrophysiology Lab, Dept of Cardiology Kane High, MD, Department of Anesthesiology
More informationZEPHYRLIFE REMOTE PATIENT MONITORING REIMBURSEMENT REFERENCE GUIDE
ZEPHYRLIFE REMOTE PATIENT MONITORING REIMBURSEMENT REFERENCE GUIDE Overview This guide includes an overview of Medicare reimbursement methodologies and potential coding options for the use of select remote
More informationEmpire BlueCross BlueShield Professional Reimbursement Policy
Subject: Evaluation and Management Services and Related Modifiers -25 & 57 NY Policy: 0026 Effective: 8/19/2013 1/31/2014 Coverage is subject to the terms, conditions, and limitations of an individual
More information510(k) Summary May 7, 2012
510(k) Summary Medicalgorithmics 510(k) Premarket Notification 510(k) Summary May 7, 2012 1. Submitter Name and Address Medicalgorithmics LLC 245 West 107th St., Suite 11A New York, NY 10025, USA Contact
More informationPacemaker Counter and Histogram Operation and Interpretation. Percentage of total count. Figure 2. Detailed ALTRUA Paced and Sensed Event Counters
A Closer Look SUMMARY This article provides information regarding the operation and interpretation of Event Counters and Histograms available in ALTRUA, INSIGNIA, PULSAR MAX II, and DISCOVERY II pacemakers.
More informationCareLink Network. Clinic Setup Guide WORKFLOWS. FAQs
INTRODUCTION CareLink Network Clinic Setup Guide All patient and clinical data displayed on the screenshots are fictitious and for demonstration purposes only. Introduction INTRODUCTION Transforming cardiac
More informationThere are only four actions that a patient can take to attempt to correct a monitor error:
MyCareLink Error Codes When an error condition occurs with the MyCareLink Patient Monitor, the display screen provides a four digit code, along with an animated graphic to help patients resolve the error.
More informationBasics of Pacing. Ruth Hickling, RN-BSN Tasha Conley, RN-BSN
Basics of Pacing Ruth Hickling, RN-BSN Tasha Conley, RN-BSN The Cardiac Conduction System Cardiac Conduction System Review Normal Conduction Conduction QRS QRS Complex Complex RR PP ST ST segment segment
More informationIntra-operative Nerve Monitoring Coding Guide. March 1, 2011
Intra-operative Nerve Monitoring Coding Guide March 1, 2011 Please direct any questions to: Patty Telgener, RN Vice President, Reimbursement Services Emerson Consultants (303) 526-7604 (office) (303) 570-2159
More informationHelpful hints for filing
Helpful hints for filing CPT coding Mary Coughlin RN, MS, NNP, Global Clinical Services Managers, Children s Medical Ventures Overview The following information describes the terminology and coding language
More information2015 Subcutaneous Implantable Defibrillator (the S-ICD TM System) Coding Guide Rhythm Management
2015 Subcutaneous Implantable Defibrillator (the S-ICD TM System) Coding Guide Rhythm Management Contents Physician Coding... 2 Hospital Outpatient Coding and Payment... 3 Ambulatory Surgery Center (ASC)
More informationGE Healthcare. The heart of cardiology is connectivity The MUSE * v8 Cardiology Information System
GE Healthcare The heart of cardiology is connectivity The MUSE * v8 Cardiology Information System Cardiac technology. Innovation to advance care. Success in today s healthcare environment requires your
More informationPurpose: To outline the care of patients with permanent or temporary pacemakers.
University of Kentucky / UK HealthCare Policy and Procedure Policy # NR08-03 Title/Description: Care of Patients with Pacemakers Purpose: To outline the care of patients with permanent or temporary pacemakers.
More informationSW012. Installation software for the Right Ventricular Lead Integrity Alert feature. Reference Manual
Installation software for the Right Ventricular Lead Integrity Alert feature Reference Manual Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. The following list
More information/-..~.~ JAN 4 2006. Mr. Dennis Conroy, SPHR
(. /-..~.~ OFFICE DEPARTMENT OF HEALTH & HUMAN SERVICES OFFICE OF INSPECTOR GENERAL OF AUDIT SERVICES 150 S. INDEPENDENCE MALL WEST SUITE 316 PHILADELPHIA, PENNSYLVANIA 19 I 06-3499 JAN 4 2006 Report Number:
More informationCLINICIAN MANUAL. LATITUDE Patient Management System
CLINICIAN MANUAL LATITUDE Patient Management System CAUTION: Federal law restricts this device to sale by or on the order of a physician trained or experienced in device implant and follow-up procedures.
More informationCCAD Training Manual. Cardiac Rhythm Management (CRM)
CCAD Training Manual Cardiac Rhythm Management (CRM) Version 1.0 A D Cunningham 19/3/2008 Introduction This manual is intended to assist users of the Notes Client version of the CCAD Cardiac Rhythm Management
More informationMEDICARE PAYMENT OF TELEMEDICINE AND TELEHEALTH SERVICES January 22, 2007
MEDICARE PAYMENT OF TELEMEDICINE AND TELEHEALTH SERVICES January 22, 2007 The Center for Medicare and Medicaid Services (CMS) administers Medicare programs in the United States. Currently, Medicare provides
More informationWhat Are Arrhythmias?
What Are Arrhythmias? Many people have questions about what the word arrhythmia means, and arrhythmias can be a difficult subject to understand. The text below should give you a better understanding of
More informationIPPS Observation vs. Inpatient Admissions Training Questions and Answers
IPPS Observation vs. Inpatient Admissions Training Questions and Answers The following questions and answers are from the Part A IPPS Observation vs. Inpatient Admissions web-based trainings conducted
More informationRemote Monitoring of Cardiac Implantable Electrical Devices (CIEDs)
Remote Monitoring of Cardiac Implantable Electrical Devices (CIEDs) Changing the face of enhanced self-management and improved coordinated healthcare K Fan, CKC Tsui, KL Au, RTC Ng, CYS Chung, KW Lai,
More informationCoverage and Authorization Services is available to respond to your coding questions toll-free at 800-292-2903.
For Urinary Control Commonly Billed Codes October 2010 Medtronic provides this information for your convenience only. It is not intended as a recommendation regarding clinical practice. It is the responsibility
More informationANESTHESIA - Medicare
ANESTHESIA - Medicare Policy Number: UM14P0008A2 Effective Date: August 19, 2014 Last Reviewed: January 1, 2016 PAYMENT POLICY HISTORY Version DATE ACTION / DESCRIPTION Version 2 January 1, 2016 Under
More informationHow can the Internet of Things help in overcoming current challenges and make healthcare sustainable
How can the Internet of Things help in overcoming current challenges and make healthcare sustainable Davide Sola, ESCP Europe Jerome Couturier, ESCP Europe Giovanni Scarso Borioli, ESCP Europe Cristina
More informationPACEART SYSTEM. Get Connected III Edition. Paceart System Administrator's Guide
PACEART SYSTEM Get Connected III Edition Paceart System Administrator's Guide Caution: Federal Law (USA) restricts this device to sale by or on the order of a physician (or properly licensed practitioner).
More informationIntraoperative Nerve Monitoring Coding Guide. March 1, 2010
Intraoperative Nerve Monitoring Coding Guide March 1, 2010 Please direct any questions to: Kim Brew Manager Reimbursement and Therapy Access Medtronic ENT (904) 279-7569 Rev 9/10 KB TO OUR PARTNERS IN
More informationNew Cardiothoracic Surgery CPT Codes for 2013
New Cardiothoracic Surgery CPT Codes for 2013 There were several changes to the cardiothoracic surgery CPT codes for 2013. There are five new codes in the general thoracic surgery section, with one revised
More informationSummary of the Proposed Rule for the Medicare and Medicaid Electronic Health Records (EHR) Incentive Program (Eligible Professionals only)
Summary of the Proposed Rule for the Medicare and Medicaid Electronic Health Records (EHR) Incentive Program (Eligible Professionals only) Background Enacted on February 17, 2009, the American Recovery
More informationCardiac Rehabilitation and Intensive Cardiac Rehabilitation JA6850
Cardiac Rehabilitation and Intensive Cardiac Rehabilitation JA6850 Related CR Release Date: March 21, 2010 Revised Date Job Aid Revised: November 17, 2010 Effective Date: January 1, 2010 Implementation
More informationAdvanced Monitoring Parameters 2015 Quick Guide to Hospital Coding, Coverage and Payment
Advanced Monitoring Parameters 2015 Quick Guide to Hospital Coding, Coverage and Payment The information in this quick guide is provided by our Healthcare Economics Department, which supports Respiratory
More informationAmbulatory Surgery Center Coding and Payment Guide 2015
Targeted Drug Delivery Ambulatory Surgery Center Coding and Payment Guide 2015 Flowonix Medical has compiled this coding information for your convenience. This information is gathered from third party
More informationStudy of Wireless Sensor Networks and their application for Personal Health Monitoring. Abstract
Study of Wireless Sensor Networks and their application for Personal Health Monitoring. Author 1 Mr. Parag Jawarkar, Author 2 Mrs. Shweta Lambat Abstract Our paper studied Wireless Sensor Network Application
More informationREVEAL LINQ LNQ11. Insertable Cardiac Monitor MRI procedural information. MRI Technical Manual
REVEAL LINQ LNQ11 Insertable Cardiac Monitor MRI procedural information MRI Technical Manual Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. The following list
More information2015 Billing and Coding Guide. Rhythm Management
2015 Billing and Coding Guide Rhythm Management Links to sections are clickable. Introduction Letter to the User i Disclaimer ii GuidePoint Reimbursement Resources at a Glance Intro 1 Medicare Payment
More informationSpecial Topics in Security and Privacy of Medical Information. Reminders. Medical device security. Sujata Garera
Special Topics in Security and Privacy of Medical Information Sujata Garera Reminders Assignment due today Project part 1 due on next Tuesday Assignment 2 will be online today evening 2nd Discussion session
More informationGEORGIA MEDICAID TELEMEDICINE HANDBOOK
GEORGIA MEDICAID TELEMEDICINE HANDBOOK CONNECTING GEORGIA OVERVIEW The Department of Community Health s (DCH) Telemedicine and Telehealth policies are slated to improve and increase access and efficiency
More informationPaceart Optima System 1.4 TECHNICAL REQUIREMENTS
Paceart Optima System 1.4 TECHNICAL REQUIREMENTS Paceart System Configuration #1: Distributed Model with HL7 Multiple workstations connecting to a central database Mainspring Data Express installed using
More informationTelecardiology Technical Innovations and Challegenes in Clinical Practice
Telecardiology Technical Innovations and Challegenes in Clinical Practice Axel Müller Clinic of Internal Medicine I (Head of Department: Prof. Dr. med. J. Schweizer) Klinikum Chemnitz ggmbh June 24, 2015
More informationCardiac Rhythm Management. BIOTRONIK Home Monitoring / Programmer. EHR Integration. FAQs. BIOTRONIK EHR DataSync Frequently Asked Questions
FAQs Cardiac Rhythm Management BIOTRONIK Home Monitoring / Programmer EHR Integration BIOTRONIK EHR DataSync Frequently Asked Questions Index Why is it important to integrate cardiac patient and device
More informationistent Trabecular Micro-Bypass Stent Reimbursement Guide
istent Trabecular Micro-Bypass Stent Reimbursement Guide Table of Contents Overview Coding 3 4 Coding Overview Procedure Coding Device Coding Additional Coding Information Coverage Payment 10 11 Payment
More informationMRI SureScan Pacing System
MRI SureScan Pacing System Step-by-step Instructions For A Successful MRI Scan Timothy S. E. Albert, MD Medical Director Advanced Diagnostic Imaging Center Monterey, CA Lisa L. Hungate, BS, RN clinical
More informationRadiology Multiple Imaging Reduction Policy
Policy Number 2015R0085C Radiology Multiple Imaging Reduction Policy Annual Approval Date 7/8/2015 Approved By Payment Policy Oversight Committee IMPORTANT NOTE ABOUT THIS You are responsible for submission
More information2014: nowadays the one shot technologies and the injectable monitor allow a wide and complete AF patient management. Why shouldn t we use them?
2014: nowadays the one shot technologies and the injectable monitor allow a wide and complete AF patient management. Why shouldn t we use them? Gaetano Senatore DIVISION OF CARDIOLOGY HOSPITAL OF CIRIE
More informationCENTRAL MONITORING AUTHORITY for CARDIOLOGY at EU LEVEL
Outline of Cardiology Training Chapter 6 Article 1 CENTRAL MONITORING AUTHORITY for CARDIOLOGY at EU LEVEL 1.1. The central monitoring authority for the specialty will be the European Board for the Specialty
More informationPolicy & Procedures. I.D. Number: 1142
Policy & Procedures Title: CARDIAC (ECG) MONITORING I.D. Number: 1142 Authorization: [X] SHR Nursing Practice Committee Source: Date Revised: November 2012 Date Effective: October 2004 Scope: SHR - Acute
More informationSummary of: P890003/S285, P090013/S112, P010031/S397, P010015/S215, P980016/S436, P980035/S343. Background and Summary
Summary of: P890003/S285, P090013/S112, P010031/S397, P010015/S215, P980016/S436, P980035/S343 Background and Summary This PMA Supplement is to obtain approval for updates to the Medtronic MyCareLink Patient
More informationAutomatic External Defibrillators
Last Review Date: May 27, 2016 Number: MG.MM.DM.10dC2 Medical Guideline Disclaimer Property of EmblemHealth. All rights reserved. The treating physician or primary care provider must submit to EmblemHealth
More informationPennsylvania Workers Compensation Billing Tutorial. Step 1: Find the Charge Classes by Zip Code
Step 1: Find the Charge Classes by Zip Code http://www.portal.state.pa.us/portal/server.pt/community/charge_classes_by_zip_co de/10428 The Pennsylvania Workers' Compensation Fee Schedule for Part B providers
More informationCentral Office N/A N/A
LCD ID Number L32688 LCD Title Cardiac Rehabilitation and Intensive Cardiac Rehabilitation Contractor s Determination Number L32688 AMA CPT/ADA CDT Copyright Statement CPT only copyright 2002-2011 American
More informationThere are two levels of modifiers: Level 1 (CPT) and Level II (CMS, also known as HCPCS).
PROVIDER BILLING GUIDELINES Modifiers Modifiers are two digit or alphanumeric characters that are appended to CPT and HCPCS codes. The modifier allows the provider to indicate that a procedure was affected
More informationAmerican Society of Echocardiography 2014 Coding and Reimbursement Newsletter
May American Society of Echocardiography Coding and Reimbursement Newsletter The ASE Coding and Reimbursement Newsletter is a resource for cardiovascular ultrasound procedures provided in the facility
More informationLes Implantables actifs: présent et futur. Pierre-Olivier Sémon
Les Implantables actifs: présent et futur Pierre-Olivier Sémon Présent Solutions for Restoring Health Product Families Pacemakers Bradycardia Indications Pacemakers Arrêt sinusal Bloc AV Fonctionnement
More informationistent Trabecular Micro-Bypass Stent Reimbursement Guide
istent Trabecular Micro-Bypass Stent Reimbursement Guide Table of Contents Overview Coding 2 3 Coding Overview Procedure Coding Device Coding Additional Coding Information Coverage Payment 8 9 Payment
More informationCentral Venous Lines, PICCs, Ports and Pumps
Central Venous Lines, PICCs, Ports and Pumps 2012 CODING AND REIMBURSEMENT GUIDE Placement of a non-tunneled or tunneled device requires that the site of entry, type of device, age of patient and tunneling
More informationQuestion and Answer Submissions
AACE Endocrine Coding Webinar Welcome to the Brave New World: Billing for Endocrine E & M Services in 2010 Question and Answer Submissions Q: If a patient returns after a year or so and takes excessive
More information2010 Medicare Part B Consultation Coding Changes 1/26/2010 & 1/27/2010
2010 Medicare Part B Consultation Coding Changes 1/26/2010 & 1/27/2010 Consultations The Centers for Medicare/Medicaid Services (CMS) finalized its proposal to require claims for consultation services
More informationNASPE Training Requirements for Cardiac Implantable Electronic Devices: Selection, Implantation, and Follow-Up
NASPE Training Requirements for Cardiac Implantable Electronic Devices: Selection, Implantation, and Follow-Up DAVID L. HAYES, GERALD V. NACCARELLI, SEYMOUR FURMAN, VICTOR PARSONNET, DWIGHT REYNOLDS, NORA
More information2015 Coding & Payment Policy Update
The Society for Cardiovascular Angiography and Interventions presents 2015 Coding & Payment Policy Update Faculty Peter Duffy, MD, MMM, F, Secretary, 2014 2015, Advocacy and Government Relations Committee
More informationMRI Case Study MRI Cervical Spine
MRI Case Study MRI Cervical Spine Jewish Hospital Louisville, KY The Revo MRI SureScan pacing system is MR Conditional designed to allow patients to undergo MRI under the specified conditions for use.
More information. 4 " ~ f.".2 DEPARTMENT OF HEALTH & HUMAN SERVICES OFFICE OF INSPECTOR GENERAL. December 19,2003. Our Reference: Report Number A-O2-03-01016
. 4 " ~..+.-"..i"..,. f.".2 '" '" ~ DEPARTMENT OF HEALTH & HUMAN SERVICES OFFICE OF INSPECTOR GENERAL Office of Audit Services Region II Jacob K. Javits Federal Building New York, New York 10278 (212)
More informationPHYSICAL PRESENCE REQUIREMENTS and DOCUMENTATION REQUIREMENTS (see Attachment I Acceptable Documentation Templates)
FACULTY PRACTICE PLAN TEACHING PHYSICIAN BILLING POLICY (Based on Medicare Carriers Manual Transmittal 1780, Section 15016, Supervising Physicians in Teaching Settings, Effective 11/22/2002) PURPOSE The
More informationThe Collaborative Models of Mental Health Care for Older Iowans. Model Administration. Collaborative Models of Mental Health Care for Older Iowans 97
6 The Collaborative Models of Mental Health Care for Older Iowans Model Administration Collaborative Models of Mental Health Care for Older Iowans 97 Collaborative Models of Mental Health Care for Older
More informationSTANDARDS FOR IMPLANTATION AND FOLLOW-UP OF CARDIAC RHYTHM MANAGEMENT DEVICES IN ADULTS January 2013
1. INTRODUCTION STANDARDS FOR IMPLANTATION AND FOLLOW-UP OF CARDIAC RHYTHM MANAGEMENT DEVICES IN ADULTS January 2013 This document replaces the previous Heart Rhythm UK documents Clinical Guidance by Consensus
More informationIl loop recorder esterno. Roberto Maggi
Il loop recorder esterno Roberto Maggi ECG monitoring and syncope In-hospital monitoring Holter Monitoring Event recorder External loop recorder Remote (at home) telemetry Implantable loop recorder External
More informationIntroduction. Planned surgical procedures
Guidelines for the perioperative management of patients with implantable pacemakers or implantable cardioverter defibrillators, where the use of surgical diathermy/electrocautery is anticipated. Introduction
More informationCOCIR GLOSSARY OF TERMS
COCIR GLOSSARY OF TERMS 2 European Coordination Committee of the Radiological, 13 COCIR TELEMEDICINE TOOLKIT 2011 Part 2 GLOSSARY OF TERMS Introduction.............................. 14 Part I: Telemedicine
More informationBilling an NP's Service Under a Physician's Provider Number
660 N Central Expressway, Ste 240 Plano, TX 75074 469-246-4500 (Local) 800-880-7900 (Toll-free) FAX: 972-233-1215 info@odellsearch.com Selection from: Billing For Nurse Practitioner Services -- Update
More informationMedicare Outpatient Therapy Billing
DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Medicare & Medicaid Services R Medicare Outpatient Therapy Billing August 2010 / ICN: 903663 DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Medicare
More informationHow To Improve Health Care For Remote Workers
CRM Devices and Telemonitoring Where the industry stands today Annette Brüls VP CRDM Marketing CareLink Status worldwide More than 450.000000 patients in > 4000 clinics > 30 countries 9 years of experience
More informationONC Project Drives Results with High- Value, Consumer- Friendly Data. [Font: Verdana Size 30]
ONC Project Drives Results with High- Value, Consumer- Friendly Data [Font: Verdana Size 30] Implantable Cardioverter-Defibrillators: High Value Data Why implantable cardioverter-defibrillators (ICDs)?
More informationSpecial Topics in Security and Privacy of Medical Information. Reminders. Last lecture: Recap. Sujata Garera. Project part 1 submission
Special Topics in Security and Privacy of Medical Information Sujata Garera Reminders Project part 1 submission Assignment 2 is online Last lecture: Recap Medical Telemetry Infrastructure Devices capturing
More informationMedicare Physician Fee Schedule Modifiers
Basics of MPFS Part 3 Medicare Physician Fee Schedule Modifiers Presented by Part B Provider Outreach and Education July 16, 2013 Disclaimer This information released is the property of Cahaba GBA and
More informationNote: This article was updated on October 1, 2012, to reflect current Web addresses. All other information remains unchanged.
Related Change Request (CR) #: 3444 Related CR Release Date: September 10, 2004 Effective Date: N/A Related CR Transmittal #: R299CP Implementation Date: N/A Note: This article was updated on October 1,
More informationInterventional Cardiology Peripheral Interventions Rhythm Management
FY2016 Hospital Inpatient Final Rule (IPPS) Interventional Cardiology Peripheral Interventions Rhythm Management On July 31, 2015, the Centers for Medicare and Medicaid Services (CMS) released the Final
More informationREMOTE CARE ALERT MANAGEMENT REFERENCE GUIDE Managing Merlin.net
REMOTE CARE ALERT MANAGEMENT REFERENCE GUIDE Managing Merlin.net Patient Care Network (PCN) Alerts Merlin.net PCN offers a powerful range of alert capabilities to give your practice the control, flexibility
More informationTry This for Medicare Fraud (Well, At Least Abuse) Part II Riva Lee Asbell
Try This for Medicare Fraud (Well, At Least Abuse) Part II Riva Lee Asbell Introduction In Part I we reviewed fraudulent/abusive practices as they applied to surgical coding. There are also many questionable
More informationNational Coverage Determination. Vagus Nerve Stimulation (VNS)
National Coverage Determination Vagus Nerve Stimulation (VNS) Number NEURO-004 Contractor Name Wisconsin Physicians Service Insurance Corporation AMA CPT Copyright Statement CPT codes, descriptions and
More information100.1 - Payment for Physician Services in Teaching Settings Under the MPFS. 100.1.1 - Evaluation and Management (E/M) Services
MEDICARE CLAIMS PROCESSING MANUAL Accessed September 25, 2005 100.1 - Payment for Physician Services in Teaching Settings Under the MPFS Payment is made for physician services furnished in teaching settings