Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

Similar documents
Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

Cliquid ChemoView 3.0 Software Simple automated analysis, from sample to report

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

MRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Authenticity Assessment of Fruit Juices using LC-MS/MS and Metabolomic Data Processing

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

ProteinPilot Report for ProteinPilot Software

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

Mass Frontier 7.0 Quick Start Guide

Pesticide Analysis by Mass Spectrometry

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

MarkerView Software for Metabolomic and Biomarker Profiling Analysis

MassHunter for Agilent GC/MS & GC/MS/MS

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS

A Streamlined Workflow for Untargeted Metabolomics

Analyst Software

Tutorial 9: SWATH data analysis in Skyline

Pesticide residue analysis: New Trends. Michal Godula, Ph.D. EU Marketing Manager Food Safety & Environmental Thermo Fisher Scientific

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Analyst 1.6 Software. Software Reference Guide

Background Information

Introduction. What Can an Offline Desktop Processing Tool Provide for a Chemist?

Mass Frontier Version 7.0

Learning Objectives:

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Effects of Intelligent Data Acquisition and Fast Laser Speed on Analysis of Complex Protein Digests

AxION edoor. Web-Based, Open-Access Mass Spectrometry Software

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Setting up a Quantitative Analysis MS ChemStation

Quick Start Guide Chromeleon 7.2

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

A Navigation through the Tracefinder Software Structure and Workflow Options. Frans Schoutsen Pesticide Symposium Prague 27 April 2015

Thermo Scientific ExactFinder Software

Waters Core Chromatography Training (2 Days)

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Q-TOF User s Booklet. Enter your username and password to login. After you login, the data acquisition program will automatically start.

Analyst 1.6 Software. Getting Started Guide

ForensicDB: A Web-accessible Spectral Database

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

SimGlycan Software*: A New Predictive Carbohydrate Analysis Tool for MS/MS Data

LC-MS/MS for Chromatographers

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

SERVICE PLANS. More Productivity. Less Worry. SERVICE PLANS

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

Using NIST Search with Agilent MassHunter Qualitative Analysis Software James Little, Eastman Chemical Company Sept 20, 2012.

NUVISAN Pharma Services

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

Metabolomics Software Tools. Xiuxia Du, Paul Benton, Stephen Barnes

STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA

Strategies for analysis of unknown samples Non targeted screening with LC TOF Examples from the Swedish National Food Agency

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

Factors Influencing LC/MS/MS Moving into Clinical and Research Laboratories

泛 用 蛋 白 質 體 學 之 質 譜 儀 資 料 分 析 平 台 的 建 立 與 應 用 Universal Mass Spectrometry Data Analysis Platform for Quantitative and Qualitative Proteomics

Analyst 1.6 Software. Laboratory Director s Guide

Application of Structure-Based LC/MS Database Management for Forensic Analysis

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

aurora ICP-MS Innovation with Integrity The Science of Sensitivity ICP-MS

Analysis of Liquid Samples on the Agilent GC-MS

Analyst Software. Advanced User Guide

Cliquid Drug Screen & Quant Software for Routine Forensic Toxicology. great interest in forensic, toxicological and clinical research laboratories.

Building Agilent GC/MSD Deconvolution Reporting Libraries for Any Application Technical Overview

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

TotalChrom. Chromatography Data Systems. Streamlining your laboratory workflow

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

Authenticity Testing of Liquor Samples using LC-MS/MS and Statistical Data Processing

GUIDELINES ON THE USE OF MASS SPECTROMETRY (MS) FOR IDENTIFICATION, CONFIRMATION AND QUANTITATIVE DETERMINATION OF RESIDUES CAC/GL

Micromass LCT User s Guide

Excel Reports User Guide

How To Test For Contamination In Large Volume Water

The First Quantitative Analysis of Alkylated PAH and PASH by GCxGC/MS and its Implications on Weathering Studies

Jennifer L. Simeone and Paul D. Rainville Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S INT RO DU C T ION

SimGlycan Software*: A New Predictive Carbohydrate Analysis Tool for MS/MS Data

Analyst Software. Release Notes

PDA Software Getting Started Guide

WATERS QUANTITATIVE ANALYSIS solutions

Investigating Biological Variation of Liver Enzymes in Human Hepatocytes

Xcalibur Versions

DO MORE AND DO IT WITH CONFIDENCE. Empower 3 Chromatography Data Software

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet

13C NMR Spectroscopy

Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

Transcription:

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS Using PeakView Software with the XIC Manager to Get the Answers (Step 3 of 3): Is anything else in my sample? Discovering and identifying non-targeted or unknown contaminants André Schreiber 1 and Lauryn Bailey 2 1 AB SCIEX Concord, Ontario (Canada); 2 AB SCIEX Framingham, Massachusetts (USA) Overview Food testing labs are always looking for ways to improve their methods and workflows. Getting to the answers - What is in my sample? How much? How sure am I of this result? etc. - must be a quick process, and as painless as possible for the laboratory analysts. In this series of articles, we will discuss workflows that routine food testing labs can use to enhance their methods for improved performance, accuracy, and throughput. For these workflows, an AB SCIEX TripleTOF LC/MS/MS system was used to screen for and identify chemical residues in extracts of fruit and vegetable samples. TripleTOF technology enables the acquisition of high resolution and accurate mass MS and MS/MS information on all peaks observed in any given sample. These information-rich data files can offer insight into the many residues and contaminants present in a given sample. The strength of the workflow lies in the software, where PeakView software with the XIC Manager add-in enables high throughput data analysis, allowing the information rich data files to be quickly screened for both targeted and non-targeted compounds. In this third article (Step 3 of 3), we describe how PeakView software with the XIC Manager can be used to process TripleTOF data files to screen for suspicious unexpected contaminants. Earlier articles described other workflows, including targeted and comparative screening with identification based chromatographic and accurate mass MS and MS/MS information. 1, 2 Introduction Liquid Chromatography coupled to Tandem Mass Spectrometry (LC-MS/MS) is a widely used analytical tool for the screening of food residues and contaminants. Triple quadrupole based mass analyzers operated in Multiple Reaction Monitoring (MRM) mode deliver highly selective and sensitive quantitative results, but are limited to targeted screening only. With an increasing demand for retrospective and non-targeted analyses of food samples, full scan mass analyzers are gaining popularity. The AB SCIEX TripleTOF systems allow the acquisition of highly sensitive full scan MS spectra with high resolution and mass accuracy. In addition, Information Dependent Acquisition (IDA) can be used to collect MS/MS spectra with unmatched speed for accurate and reliable compound identification using MS/MS library searching. 3, 4 The complexity of such data requires powerful data mining tools. The XIC Manager can be used for targeted and non-targeted processing of high resolution MS and MS/MS data. 5 p 1

The Data Analysis Workflow 1. Setting-up your XIC table and processing parameters for unknown screening Open one or more data files for unknown (comparative) screening in PeakView software Display of sample chromatogram Display of control chromatogram Start a new session in the XIC Manager menu Figure 1. The XIC Manager with two samples loaded and ready for comparative unknown screening. To start the non-targeted peak finding algorithm simply click the highlighted botton. Select your MS/MS library in the Options dialog box The XIC Manager can be used for screening and identification of targeted food residues and contaminants using compound databases and MS/MS libraries. 1 The XIC Manager can also be used for comparative screening to identify compounds above a target concentration. 2 Processing of LC-MS/MS data is performed through extracted ion chromatograms (XIC) using a defined list of masses or formulas (XIC table). Automatic identification with highest confidence is based on retention times, accurate mass, isotopic pattern and MS/MS library searching. The XIC Manager can also be used to explore chromatograms using a non-targeted peak finding algorithm to find and identify unexpected chemicals. Open a single data file for unknown screening or two data files for comparative unknown screening (i.e. sample-controlcomparison). Select the suspicious sample using the drop-down menu below the XIC table. Select the control, like an uncontaminated and unadulterated sample. Note that the XIC table is left blank. No information on expected masses nor retention times are required. Select clean control sample Select suspicious contaminated sample p 2

2. Performing comparative unknown screening on your data using the XIC Manager Contaminated tomato Organic tomato You are now ready to start unknown screening of your TripleTOF data. Start processing by clicking Define threshold (ratio sample and control) TOF-MS review (unknown sample) TOF-MS/MS review (unknown sample) Review your results TOF-MS review (standard) TOF-MS/MS review (standard) Figure 2. The result display of the XIC Manager: The pesticides Carbendazim and Thiamethoxam were identified using MS/MS library searching after non-targeted peak finding and automatic comparison of a contaminated tomato with an organic control. Start the non-target peak finding algorithm by simply clicking Build New List button on top of the XIC table (Figure 1). Once the processing is completed, define a threshold for comparison (ratio sample and control). A threshold of 10 will highlight all compounds in the XIC table which are present in the suspicious sample with a signal at least 10x higher than in the clean control sample. XICs with a higher signal in the unknown sample than in the control are highlighted in green. Click the Display Highlighted XIC Only button in the top right of the XIC table to display only these XICs. XICs of all found compounds in the two samples selected are displayed in the chromatogram pane (Figure 2 top). MS/MS spectra of all XICs found are searched automatically against the selected MS/MS library. The AB SCIEX imethod Meta Library contains MS/MS spectra for more than 2500 compounds. Library search results are listed in the XIC table (middle). Spectra can be reviewed in the MS and MS/MS pane (bottom). Spectra of non-identified compounds can be further processed in PeakView software. p 3

3. Identifying unknown compounds using empirical formula finding and automatic ChemSpider search Identify unknowns using MS and MS/MS spectra in PeakView software TOF-MS TOF-MS/MS Start the Formula Finder Review MS and MS/MS ranking Review ChemSpider matches Figure 3. Unknown identification using PeakView software: The pesticide Fludioxonil was tentatively identified after empirical formula calculation and automatic ChemSpider search Highlight the isotopic pattern of the compound of interest in the MS spectrum and start the Formula Finder in the Show menu of PeakView software. Drag the MS icon or MS/MS icon of the formula finder pane to select another spectrum for processing. The Formula Finder automatically uses accurate mass information of the molecular ion, adducts, isotopic pattern, and fragment ion information to empirically calculate potential molecular formulas for the detected compound. Review the MS and MS/MS ranking. The MS Details tab shows an overlay of acquired and theoretical isotopic pattern (Figure 3 top) and the MS/MS Details tab shows the mass accuracy of predicted fragment ions (middle). The Formula Finder also performs an automatic ChemSpider search returning possible structures for all calculated formulas (bottom). Note that you need to register in ChemSpider to activate this feature. You can further evaluate structures using the Fragments Pane in PeakView software. This feature compares the structure with known fragmentation pathways and reports how many fragments of the MS/MS spectrum match. 4 The results shown in Figures 2 and 3 are examples of using the comparative screening function using a non-targeted peak finding algorithm to find unknown compounds in complex food samples. A simple MS/MS library search against the imethod meta library can identify unexpected compounds using this workflow. The Formula Finder and automatic ChemSpider search can be used for identification if the library search does not return a hit for a compound of interest. p 4

Summary References High resolution and accurate mass LC-MS/MS was used to screen for and identify chemical residues and contaminants in fruit and vegetable samples. The AB SCIEX TripleTOF system was operated in IDA mode to acquire MS and MS/MS information simultaneously. The XIC Manager add-in of PeakView software was used to compare samples using a non-targeted peak finding algorithm to identify unexpected compounds in suspicious samples. Compound identification is based MS/MS library searching. The Formula Finder and automatic ChemSpider search is a useful and easy-to-use tool for identification if the library search does not return a hit for a compound of interest. For additional support on this and other AB SCIEX products, visit our website or email us at support@absciex.com. The Complete Series of PeakView with XIC Manager Software Workflow Demos: Step 1 of 3: What is in my sample? Implementing targeted compound databases and libraries for identification Click here to watch the video of Step 1. Step 2 of 3: How much is in my sample? Comparative screening for identification of targeted compounds above a specific concentration Click here to watch the video of Step 2. Step 3 of 3: Is anything else in my sample? Discovering and identifying non-targeted or unknown contaminants Click here to watch the video of Step 3. 1 2 3 4 5 A. Schreiber and D. Cox: Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC- MS/MS - Using PeakView Software with the XIC Manager to Get the Answers (Step 1 of 3) Application Note AB SCIEX (2012) #6600212-01 A. Schreiber and D. Cox: Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC- MS/MS - Using PeakView Software with the XIC Manager to Get the Answers (Step 2 of 3) Application Note AB SCIEX (2012) #6600412-01 A. Schreiber and C. Borton: Target and Non-Target Screening for Pesticide Residues in Food Samples using the AB SCIEX TripleTOF 5600 System Application Note AB SCIEX (2010) #0460110-02 A. Schreiber and C. Seto: Target and Non-Target Screening for Chemical Residues in Food Samples using the AB SCIEX TripleTOF 4600 System and Intuitive Data Processing Tools Application Note AB SCIEX (2012) #5680212-01 A. Schreiber and D. Cox: Using PeakView Software with the XIC Manager for Screening and Identification with High Confidence based on High Resolution and Accurate Mass LC-MS/MS Application Note AB SCIEX (2011) #2170811-03 For Research Use Only. Not for use in diagnostic procedures. 2012 AB SCIEX. The trademarks mentioned herein are the property of AB Sciex Pte. Ltd. or their respective owners. AB SCIEX is being used under license. Publication number: 6600612-01 Headquarters International Sales 353 Hatch Drive Foster City CA 500 Old Connecticut Path, Framingham, MA 01701 USA For our office locations please call the division Phone 508-383-7700 headquarters or refer to our website at www.absciex.com www.absciex.com/offices