crm+130/iu/tc/e Extract from our online catalogue: Current to: 2016-04-21

Similar documents
crm+25/d/tc/e Extract from our online catalogue: Current to:

How To Make An Ultrasonic Sensor

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

BOS 73K... BOS 74K...

photoelectric highlights

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

96 Variants. The GlobalProx range increases in popularity. 12 PNP Normally-open 12 PNP Normally-closed 12 NPN Normally-open 12 NPN Normally-closed

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Inductive sensor NI10-M18-Y1X-H1141

Digital display DA 48

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Turbine Flow Sensor Series VTR

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Electronic Pressure Switch EDS 300

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Electric Rotary Actuator - On/Off or programmable control actuator

Instruction Manual Service Program ULTRA-PROG-IR

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

FREJA 300 Relay Testing System

How To Use A Flowmeter

Vacuum drying oven for non-flammable solvents

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Magnetic proximity switches

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Inductive Proximity Sensors

LUT Luminescence scanners: Seeing what no-one else can

intelligent solutions

E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

PRODUCT PROFILE FEATURES

Technical Data. Dimensions

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

FACTORY AUTOMATION INTELLIGENT CLAMP MONITORING FOR MACHINE TOOL SPINDLES WITH INDUCTIVE POSITIONING SYSTEMS

Multifunction devices

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

New XUY roller sensors

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Preset Counter signo 721

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

The new generation: WLL180T photoelectric sensor with fiber-optic cable. Around the corner at High Speed

- 1 - Eddy Current. Eddy current distance and displacement transducer

T0118 T2118 T3118. Instruction Manual

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

Contents. Document information

Quick Connect. quick - simple - efficient.

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

Encoder WDGI 58H.

Proportional pressure regulators VPPE

Innovation for cost reduction in pneumatics. Leakage monitoring. Measurement of compressed air consumption.

ONLINE DATA SHEET. Contrast sensors KTM KTM-WP11181P

MEITRACK Fuel Sensor User Guide. Applicable Model: MVT600/T1/MVT800/T333

Technical Data. Dimensions

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Barcode positioning systems BPS 8, BPS 34/37 Innovations that truly move you forwards.

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

MIN Q SERIES MICRO-PROXIMITY SENSOR DC 3-WIRE TYPE

Conductive Level Switch FK 2 Technical Data:

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Application book Material Handling: forklifts. Inductive Sensors. Proximity Sensor

Incubator with mechanical convection

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

W 36: Mastering complex tasks reliably

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

USB-500 Series Stand-Alone, Low-Cost Data Loggers

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Modular I/O System Analog and Digital Interface Modules

User Manual Weather station V 0.2

Measuring Sensors PRODUCT DESCRIPTION

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

ABB i-bus KNX SA/S Switch Actuators Product Manual

Operating Instructions for Plastic Flow Meter. Model: KSK

Technical Information RIA14

Transcription:

Extract from our online catalogue: crm+130/iu/tc/e Current to: 2016-04-21 microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E info@microsonic.de microsonic is a registered trademark of microsonic GmbH. All rights reserved.

Wear-resistant PEEK film protects the sensor membrane from chemicals, contamination and caking. HIGHLIGHTS Ultrasonic transducer protected by PEEK film Stainless-steel housing Digital display with direct measured value output in mm/cm or % Numeric configuration of the sensor using digital display Automatic synchronisation and multiplex operation BASICS 1 or 2 switching outputs in pnp variant Analogue output 4 20 ma and 0 10 V 5 detection ranges with a measurement range of 30 mm to 8 m microsonic Teach-in using T1 or T2 buttons 0.025 mm to 2.4 mm resolution Temperature compensation 9 30 V operating voltage LinkControl for configuration of sensors from a PC for simple cleaning and high resistance to wear permits the complete advance configuration of the sensor for simultaneous operation of up to ten sensors in close quarters with automatic switching between current and voltage outputs

Description Sensor membrane with wear-resistant protective film In many filling processes, spray on the sensor membrane simply cannot be avoided. These sprays often harden so that after longer periods of operation contamination can only be removed from the sensor membrane by mechanical means. The new protective film of the crm+ sensors now makes it easy to remove caked-on soiling, such as hardened casting compound and cement spatter. The protective film is also highly resistant to corrosive media. The threaded sleeve is made of 1.4571 stainless steel. TouchControl with LED display - Wear-resistant PEEK protective film There are three output stages available for all five detection ranges: 1 pnp switching output 2 pnp switching outputs 1 analogue output 4 20 ma and 0 10 V The crm+ sensors with switching output have three operating modes: Single switching point Two-way reflective barrier Window mode With TouchControl all configuration can be done right at the sensor. The easily legible three-digit LED display continually shows the current

distance value and automatically switches between millimetre and centimetre displays. Setting a switching or analogue output can optionally be carried out by numeric input of the desired distance values, or using a teach-in procedure. This permits the user to select the configuration method preferred. The crm+ sensors support synchronisation and multiplex operation and have extensive parameterisation options via LinkControl. For detailed information, please see at mic+ sensors. LinkControl consists of the LinkControl adapter and the LinkControl software and facilitates the configuration of the crm+ sensors via a PC or laptop with any conventional Windows operating system. Sensor connected to the PC via LCA-2 for programming

crm+130/iu/tc/e scale drawing detection zone 1 x analogue 4-20 ma + 0-10 V 2,000 mm operating range design operating mode particularities 200-2.000 mm cylindrical M30 analogue distance measurements high chemical resistance stainless steel version display ultrasonic -specific means of measurement transducer frequency blind zone operating range maximum range resolution/sampling rate echo propagation time measurement 200 khz 200 mm 1,300 mm 2,000 mm 0.18 mm reproducibility ± 0.15 % accuracy ± 1 % (temperature drift internally compensated) electrical data operating voltage U B 9-30 V d.c., reverse polarity protection voltage ripple ± 10 % no-load current consumption type of connection 80 ma 5-pin M12 initiator plug

crm+130/iu/tc/e outputs output 1 response time delay prior to availability analogue output current: 4-20 ma / voltage: 0-10 V (at U 15 V), short-circuit-proof switchable rising/falling 110 ms < 300 ms B inputs input 1 com input synchronisation input housing material ultrasonic transducer stainless steel, plastic parts: PBT, TPU coated with PEEK film, PTFE O-ring class of protection to EN 60529 IP 67 operating temperature storage temperature weight further versions -25 C to +70 C -40 C to +85 C 110 g cable connection (on request) technical features/characteristics temperature compensation controls scope for settings Synchronisation multiplex indicators particularities yes 2 push-buttons + LED display (TouchControl) Teach-in and numeric configuration via TouchControl LCA-2 with LinkControl yes yes 3-digit LED display, 2 x three-colour LED high chemical resistance stainless steel version display

crm+130/iu/tc/e documentation (download) pin assignment order no. crm+130/iu/tc/e