LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research



Similar documents
Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Gas Chromatography Liner Selection Guide

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

How To Test For Contamination In Large Volume Water

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

Comparison of the Reversed-Phase Selectivity of Solid Core HPLC Columns

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Introduction. Methods. Sample Processing

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Utilization of Rapid LC-MS for Screening and Quantitative Analysis of Pesticides in Food Matrix using an Exactive Plus Benchtop Orbitrap Platform

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum

A Novel Approach to Low Volume Sample Preparation

Overview. Purpose. Methods. Results

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

Jennifer L. Simeone and Paul D. Rainville Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S INT RO DU C T ION

Determination of Tetracycline Antibiotics in Milk Using a Simple Strong Cation-Exchange SPE Cleanup Procedure and LC-MS/MS Analysis

Oasis HLB Cartridges and 96-Well Plates

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

A Complete Solution for Method Linearity in HPLC and UHPLC

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

High-Throughput 3-D Chromatography Through Ion Exchange SPE

A New QuEChERS Dispersive SPE Material and Method for Analysis of Veterinary Drug Residue by LC-MS-MS

A Determination of Veterinary Drug Residues in Milk Using Polymeric SPE and UHPLC-MS/MS Analysis

ApplicationNOTE Introduction

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

Therapeutic Drug Monitoring of Antiretroviral Drugs with HPLC-MS

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

Quick and Sensitive Analysis of Multiclass Veterinary Drug Residues in Meat, Plasma, and Milk on a Q Exactive Focus LC-MS System

Development and Validation of Methods for Chemotherapy Drugs on the New Prelude SPLC LC-MS/MS System

Thermo Scientific Mass Spectrometric Immunoassay (MSIA)

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

ORGANIC SAMPLE PREPARATION

CORESTA RECOMMENDED METHOD N 72

Empore. 96-Well Solid Phase Extraction Plates. Technical Information. Instructions for Use. Product Characteristics. Product Description

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

ProteinChip Energy Absorbing Molecules (EAM)

Purification of reaction mixtures using flash chromatography.

Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC

United States Department of Agriculture Food Safety and Inspection Service, Office of Public Health Science

An In-Gel Digestion Protocol

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

A Generic Kit-Based Approach for Quantifying Monoclonal Antibody Drugs Through Direct Digestion of Discovery Study Samples

Application Note # LCMS-92 Interlaboratory Tests Demonstrate the Robustness and Transferability of the Toxtyper Workflow

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

for mass spectrometry calibration tools Thermo Scientific Pierce Controls and Standards for Mass Spectrometry

METHOD OF ANALYSIS. N methyl 2-pyrrolidone

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

S olid Ph ase Extraction (SP E) Method:

A Generic LC-MS Method for the Analysis of Multiple of Drug of Abuse Classes with the Thermo Scientific Exactive TM System

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

New drugs of abuse? A case study on Phenazepam & Methoxetamine

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Innovative vs Traditional

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Opiates in Urine by SAMHSA GC/MS

High Sensitivity MS Determination of Carryover in a New Autosampler Design

A feasibility study of the determination of B-group vitamins in food by HPLC with Mass Spectrometric detection. LGC/R/2011/181 LGC Limited 2011

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

AppNote 1/2014. Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine KEYWORDS ABSTRACT

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

APPLICATIONS MANUAL. Ifosfamide in blood serum Ingredients in blood serum Organophosphorus pesticides in tea leaf... 5

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

Standard Analytical Methods of Bioactive Metabolitesfrom Lonicera japonica Flower Buds by HPLC-DAD and HPLC-MS/MS

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

Accelerate your Quantitative LC/MS Workflows with a Fully Integrated UHPLC-QQQ Platform

Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS

Structural Analysis of Labeled N-Glycans from Proteins by LC-MS/MS Separated Using a Novel Mixed-Mode Stationary Phase

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

Sensitive steroid analysis on a new High Speed Triple Quadrupole LC/MS/MS. Mikaël LEVI Shimadzu France

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Conversion of a USP Gas Chromatography Method to Convergence Chromatography: Analysis of Atropa Belladonna

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

LC-MS/MS, the new reference method for mycotoxin analysis

Transcription:

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research J. Jones, J. Denbigh, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20581 Key Words SPE, SOLA, Accucore RP-MS, docetaxel, clinical research Abstract A liquid chromatography-tandem mass spectrometry method for the analysis of docetaxel in human serum for clinical research has been developed. Using Thermo Scientific TM SOLA TM cartridges or plates, sample preparation is fast and gives excellent reproducibility and recovery levels. The analysis was carried out on a Thermo Scientific Accucore TM RP-MS 2.6 µm, 50 x 2.1 mm column for a fast separation with a cycle time of 2 minutes and excellent peak shape. Introduction SOLA solid phase extraction (SPE) products introduce next-generation, innovative technological advancements, which give unparalleled performance characteristics compared to conventional SPE, phospholipid, and protein precipitation products. This includes: Higher levels of reproducibility Higher levels of extract cleanliness Reduced solvent requirements Increased sensitivity SOLA products have significant advantages for the analyst when processing compounds in complex matrices, particularly in high-throughput clinical research laboratories where reduced failure rate, higher analysis speed, and lower sample/solvent requirements are critical. The increased performance gives higher confidence in analytical results and lowers cost without compromising the ease of use or requiring complex method development. Accucore HPLC columns use Core Enhanced Technology TM to facilitate fast and highly efficient separations. The 2.6 µm diameter particles are not totally porous, but have a solid core and a porous outer layer. The optimized phase bonding creates a series of high coverage, robust phases. Accucore RP-MS columns use an optimized alkyl chain length for more effective coverage of the silica surface. This coverage results in a significant reduction in secondary interactions and highly efficient peaks with very low tailing. The tightly controlled 2.6 µm diameter of the Accucore particles results in much lower backpressures than typically seen with sub-2 µm materials. Docetaxel is an anti-mitotic agent used in cancer chemotherapy (Figure 1). The extraction of docetaxel from human plasma is demonstrated in this application. Figure 1: Docetaxel

2 Experimental Details Consumables Fisher Scientific TM LC/MS grade water W/011217 Fisher Scientific LC/MS grade methanol M/4062/17 Fisher Scientific LC/MS grade acetonitrile A/0626/17 Fisher Scientific Analytical grade formic acid F/1900/PB08 Fisher Scientific Sodium acetate S/2120/50 Thermo Scientific National TM Mass Spec Certified 2 ml clear vial MSCERT4000-34W with blue bonded PTFE silicone cap Sample Handling Equipment Thermo Scientific 96 well plate vacuum manifold 60103-351 Thermo Scientific Ultra vap CLS-229070 Sample Pretreatment A standard spiking solution of docetaxel was prepared in acetonitrile. A working internal standard solution (paclitaxel) was prepared in acetonitrile. A sample of 200 µl of blank human plasma was taken. For standards and quality control (QC) samples, 10 µl of standard spiking solution was added to 200 µl of blank human plasma, and for blanks, 10 µl of acetonitrile was added. For standards and QCs, 10 µl of working internal standard solution was added, and for blanks, 10 µl of acetonitrile was added. All samples were vortexed for 30 seconds and then centrifuged for 5 minutes at 5000 rpm. Sample Preparation Compound(s): Matrix: Docetaxel, paclitaxel (IS) Human serum Plate type: Thermo Scientific SOLA 10 mg/2 ml 60309-001 Conditioning stage: Application stage: Washing stage: Elution stage: 0.5 ml methanol followed by 0.5 ml water Apply spiked sample. 250 µl water / acetonitrile (70:30 v/v) 2 x 250 µl acetonitrile + 1% ammonia Additional stage: Dry down under nitrogen without heat and reconstitute in 200 µl water/ acetonitrile (50:50 v/v) + 0.5% 20 µm sodium acetate. Mix well. (Sodium acetate was required to ensure the reproducible formation of a sodium adduct, which was used for quantification. At this low concentration of sodium acetate no source contamination was observed.)

Separation Conditions Instrumentation: Thermo Scientific Dionex TM UltiMate TM 3000 RSLC HPLC system Column: Accucore RP-MS, 2.6 µm, 50 x 2.1 mm 17626-052130 Mobile phase A: Mobile phase B: Gradient: Flow rate: Water + 0.1% formic acid Methanol + 0.1% formic acid 60% 70% B in 2 minutes 0.6 ml/min Column temperature: 30 C Injection details: 2.5 µl Injection wash solvent 1: Injection wash solvent 2: Water / acetonitrile (80:20 v/v) Propan-2-ol / acetonitrile / acetone (45:45:10 v/v/v) 3 MS Conditions Instrumentation: Thermo Scientific TSQ Vantage TM MS Ionization conditions: HESI Polarity: Positive Spray voltage (V): 4000 Vaporizer temperature ( C): 450 Sheath gas pressure (Arb): 30 Aux gas pressure (Arb): 20 Capillary temp ( C): 365 Collision pressure (mtorr): 1.5 Scan time (s): 0.02 Q1 (FWHM): 0.7 Q3 (FWHM): 0.7 The compound transition information is shown in Table 1. Compound Paclitaxel (IS) Docetaxel Parent (m/z) 876.25 830.26 Products (m/z) 308.25 549.24 Collision energy (V) 25 23 S-lens (V) 141 121 Table 1: Compound transition details Data Processing Software: Thermo Scientific LCQUAN TM

4 Results Docetaxel standards extracted from human serum gave a linear calibration curve over the dynamic range of 0.25 to 10 ng/ml with an r 2 coefficient of 0.9974 (Figure 2 and Table 2). The chromatography of the LLOQ at 0.25 ng/ml is shown in Figure 3. QC samples were run in replicates of six at concentrations of 0.3, 1.5, and 6 ng/ml. The precision of each of the QC levels was 8.8% CV at all three levels (Table 3). Overspiked samples were analyzed at concentrations of 0.75 ng/ml and used to calculate recovery. The average percentage recovery level of docetaxel was 109% (Table 4.) Area Ratio 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 Relative Abundance 100 90 80 70 60 50 40 30 0.2 0.1 0.0 0 2 4 6 8 10 ng/ml 20 10 0 0 0.5 1.0 1.5 2.0 2.5 3.0 Time (min) Figure 2: Docetaxel linearity over the dynamic range 0.25 to 10 ng/ml Figure 3: Representative chromatogram of docetaxel SRM, extracted from human plasma at 0.25 ng/ml Accuracy and Precision Standard Specified Calculated %Diff S1 0.250 0.261 4.52 S2 0.500 0.525 5.06 S3 1.00 0.959-4.14 S4 2.50 2.39-4.59 S5 5.00 4.59-8.21 S6 7.00 7.48 6.87 S7 10.0 10.5 4.54 S7 10.0 9.60-4.04 Table 3: Accuracy data for docetaxel extracted standards over the linear range 0.25 to 10 ng/ml Quality Control Average Calculated (n=6) Precision (%CV) QCL 0.300 0.313 4.5 QCM 1.50 1.53 8.8 QCH 6.00 6.02 5.9 Table 4: Average precision data for six replicate QCs for docetaxel

Recovery Response Average area response (n=6) 260035 Overspiked area response 238397 Table 5: Recovery data for docetaxel Conclusion SOLA SPE plates and Accucore RP-MS HPLC columns allow for a simple extraction and rapid quantification of docetaxel from human serum for clinical research using an internal standard. % Recovery 109 Application Note 20581 An LLOQ of 0.25 ng/ml was demonstrated. Extraction recovery was 109%. The method showed excellent precision with %CV (n=6) 8.8%. For research use only. Not for use in diagnostic procedures. thermoscientific.com/chromatography 2012 Thermo Fisher Scientific Inc. All rights reserved. Taxotere is a registered trademark of Aventis Pharmaceuticals, Inc. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific Inc. products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. USA and Canada +1 800 332 3331 France +33 (0)1 60 92 48 34 Germany +49 (0) 2423 9431 20 or 21 United Kingdom +44 (0)1928 534110 Japan +81 3 5826 1615 AN20581_E 08/12S China +86 21 68654588 +86 10 84193588 +86 20 83145199 800 810 5118 India +91 22 6742 9494 +91 27 1766 2352 Australia 1 300 735 292 (free call domestic) New Zealand 0800 933 966 (free call domestic) All Other Enquiries +44 (0) 1928 534 050 Technical Support North America +1 800 332 3331 Outside North America +44 (0) 1928 534 440