Computer Gateway Specification and Technical Data



Similar documents
Computer Gateway Specification and Technical Data

L5354 ControlNet Communications Interface

Modbus Communications for PanelView Terminals

3500/22M Transient Data Interface

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

Waveguide Access Point WGA631. Product Guide

Gigabit Ethernet Copper-to-Fiber Converters

Foxboro Evo Process Automation System

Uniformance. PHD Server. Specification Sheet R320

Communication Unit 560CMU05 Data sheet

Appendix B RCS11 Remote Communications

SAN Conceptual and Design Basics

DA-3600A Data Network Analyzer Advanced Network analysis and troubleshooting

DEPARTMENT OF COMPUTER SCIENCE & ENGINEERING Question Bank Subject Name: EC Microprocessor & Microcontroller Year/Sem : II/IV

Manageable 10/100/1000 Mbs Ethernet Modular Multi-Media Switch

CCNA R&S: Introduction to Networks. Chapter 5: Ethernet

White Paper. Technical Capabilities of the DF1 Half-Duplex Protocol

Fleet Manager II. Operator Manual

IntesisBox KNX LG Air Conditioning

EMC DATA DOMAIN ENCRYPTION A Detailed Review

Chapter 3: Operating-System Structures. System Components Operating System Services System Calls System Programs System Structure Virtual Machines

S-series SQ Controller

Programmable Controller G Series. New. Models

Operation and Installation Manual

ROC Protocol Specifications Manual

ABB i-bus EIB Logic Module LM/S 1.1

By the Citrix Publications Department. Citrix Systems, Inc.

2011, The McGraw-Hill Companies, Inc. Chapter 3

MBP_MSTR: Modbus Plus Master 12

Modbus and ION Technology

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2

Voltage Regulator SPAU 341 C. Product Guide

Modbus and ION Technology

VARIO PROX CARD READER INSTALLATION MANUAL

CPUs - CPU PN/DP

Omron I/O Driver (Series 2) Programmable Serial Interface Card

CONTROL MICROSYSTEMS DNP3. User and Reference Manual

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

M-series Virtual I/O Module 2

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

Overview of the Cisco 2500 Series Access Server

EDI Distributor Control Interface Wiring and Setup Instructions

Centralized Orchestration and Performance Monitoring

VALIANT COMMUNICATIONS

WANic 800 & or 2 HSSI ports Up to 52 Mbps/port. WANic 850 & or 2 T3 or E3 ports Full-speed CSU/DSU. WANic 880.

Honeywell Process Solutions Experion HS R400 Server Patch220 for PAR1-MVKSRD Software Change Notice

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

QuickSpecs. HP IP Console Switch with Virtual Media Overview

Rack mounted telephone- and leased line modem for industrial applications

Process Control and Automation using Modbus Protocol

AVR1309: Using the XMEGA SPI. 8-bit Microcontrollers. Application Note. Features. 1 Introduction SCK MOSI MISO SS

Disturbance Recoder SPCR 8C27. Product Guide

Storage System. Planning Checklist. EC E1, First Edition

HP Server Console Switch with Virtual Media Overview

Measurement and Analysis Introduction of ISO7816 (Smart Card)

ESPA Nov 1984 PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION

How To Set Up A Modbus Cda On A Pc Or Maca (Powerline) With A Powerline (Powergen) And A Powergen (Powerbee) (Powernet) (Operating System) (Control Microsci

QuickSpecs. Models HP Server Console Switches

PCS0100en Persy Control Services B.V. Netherlands

CA Nimsoft Monitor. Probe Guide for Active Directory Server. ad_server v1.4 series

F2400 FOM II Series Fiber Optic Modem Technical Manual

Overview of Cisco 2600 Series Routers

HP Network Security Processors

SMS based remote control system

Temperature & Humidity SMS Alert Controller

RealSSD Embedded USB Mass Storage Drive MTFDCAE001SAF, MTFDCAE002SAF, MTFDCAE004SAF, MTFDCAE008SAF

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

Telephone- and leased line modem for industrial applications TD-36

Technical Support Bulletin Nr.18 Modbus Tips

Bristol ControlWave Redundant Control

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

Telecommunications Switching Systems (TC-485) PRACTICAL WORKBOOK FOR ACADEMIC SESSION 2011 TELECOMMUNICATIONS SWITCHING SYSTEMS (TC-485) FOR BE (TC)

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

Application Unit, MDRC AB/S 1.1, GH Q R0111

Interface Adapters PS/2 Interface Adapter 1 pack B21 PS/2 Interface Adapter 8 pack B21 USB Interface Adapter 1 pack B21

OTX T1/E1 Remote Control Utility Users Guide

LonManager PCC-10 and ISA Protocol Analyzers Models and

3500/93 System Display

Application Note. Introduction AN2471/D 3/2003. PC Master Software Communication Protocol Specification

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Develop a Dallas 1-Wire Master Using the Z8F1680 Series of MCUs

IBM Flex System PCIe Expansion Node IBM Redbooks Product Guide

Total Disaster Recovery in Clustered Storage Servers

How To Use An American Zw.Com V20-20 (V20) V20 (Veu) V2.20 (Femalese) V1.2.2 (V2.1) V3.

Permissible ambient temperature Operation Storage, transport

OZW30. Central Unit SYNERGYR

DeviceNet Communication Manual

How To Use The Cisco Aironet 1240G Series For A Wireless Network (Wired) And For A Wired Network (Wireless)

is then retained absolutely without interruption.

Table of Contents. TransformerIQ FAQs 1

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

DC Electronic Loads 8500 series

Transcription:

L Computer Gateway Specification and Technical Data CG03-500 R500 3/96 detergant coffee chocolate

Page 2 TDC 3000X Computer Gateway Specification and Technical Data Introduction This publication defines the significant functions of the Computer Gateway (CG), a TDC 3000 X gateway that provides an interface from the Local Control (LCN) to a user-selected host computer. (To connect to a Digital Equipment Corporation (DEC) computer, refer to the PLNM Specification and Technical Data.) The CG is a node on the LCN, as shown in Figure 1. It allows a user-selected host computer to communicate with: All modules on a Local Control, s on remote Local Control s through Gateways, UCN devices, and Data Hiway devices. See System Technical Data for more information on the CG s relationships with other modules and process-connected devices. Implementation details are available in the Computer Gateway User Manual. New Computer Gateway Features in R500 LCN Software History journal data retrieval added Improved file transfer speed Enhanced file transfer command to list files into a dataout file (now identical to Command Processor) Additional LCN s Fiber Optics Archive Replay Application History Universal Stations Gateway Host Computer Gateway Computer Gateway Universal Work Station LCN Extenders DATA HIWAY Hiway Gateway LOCAL CONTROL NETWORK NO. 1 Data Hiway Boxes Interface High Performance Process Safety Advanced Process Plant Information Remote I/O UNIVERSAL CONTROL NETWORKS LOCAL CONTROL NETWORK NO. 2 Interface Logic Advanced Process Process Subsystem Smartline 3000 Figure 1 TDC 3000 X Architecture With Computer Gateway 15010

Page 3 Functional Description The relationships of the CG functions are shown in Figure 2. The host computer is used for data collection needed for management information system or plant management requirements (including both current values and historical data), and a higher level and wider scope of control than is possible with any other device. Typically, CG control strategies are implemented in conjunction with Process, Advanced Process, and Application control strategies. Computer Gateway Functions Provides a standard interface between the Local Control and the user-selected host computer Collects data from other LCN nodes and stores data to other nodes on request from the computer Collects continuous history data from the History Holds a database that represents computer programs, plus other computer-prepared data Provides for scheduling and/or operator/event demand of computer programs Transmits messages to Universal Station operators Receives messages from Advanced Process, Process, and Multifunction Controller sequences Performs file transfer and management functions Retrieves LCN History journals to the host computer Host Computer to CG Link Information is exchanged between the host computer and the CG over a serial communication link using either Bisynch, or HDLC protocol.* For a Bisynch system, either one or two links are supported. For an HDLC system, one full-duplex link is supported. The standard interface is an RS422, Type RS449 interface, with configurable speed up to 76.8 k baud for a Bisynch application and 57.6 k baud for HDLC. (NOTE: An RS232 interface, with a configurable speed up to 19.2 K baud could also be used, instead of the RS422 interface. However, the CG is supplied only with the latter (i.e., RS422) interface as standard. * Bisynch Binary Synchronous Communications Protocol Procedure for Point-to-Point Operation with Contention, as described in IBM publication GA27-3004-2, using transparent Bisynch with EBCDIC control characters. Maximum block size is 1024 bytes, and both single and multiple block transactions (maximum of 13 blocks) are supported. HDLC Link Access Procedure, Balanced (LAPB) per C.C.I.T.T. Document AP VIII-58-E, June, 1984 (Recommendation X.25), and compliance with FIPS 100 certification. Messages between the computer and CG are managed by a HOST PROCESSOR BISYNCH OR HDLC DATA LINK COMPUTER GATEWAY APPLICATION PROGRAMS INTERFACE ROUTINES DISPATCHER PROGRAM COMMUNICATION HANDLER COMMUNICATION HANDLER SCHEDULER PROGRAM DATABASE ACIDPs & CRDPs COMMUNICATION HANDLER (LCN) LOCAL CONTROL NETWORK communications handler program that queues messages for HOST PROCESSOR SOFTWARE ENVIRONMENT CG SOFTWARE ENVIRONMENT Figure 2 Host Processor/Computer Gateway/Local Control Relationships 1164

Page 4 HEADER BLOCK Transaction Code Number of Words Number of Blocks Block Number CG Identifier Host Task Identifier Message Tag Message Counter 1 2 3 4 5 6 7 8 16-Bit Words MESSAGE BLOCK 9 n n depends on transaction type maximum = 512. Maximum message size (= 504-8)16-bit words. 1165 Figure 3 Message Format forwarding to the computer, and distributes messages received from the host to the appropriate LCN destination. Figure 3 shows the message format. The user is expected to provide a communications handler in the computer, along with computer routines to support CG functions. No programming of the CG itself is required; it is configured in a manner similar to other LCN nodes through the Engineer Personality or Universal Personality of the Universal Station. Data Collection and Storage Computer programs can gain access to data throughout the TDC 3000 X system. This is accomplished through seven major types of CG functions: Link Handling/Restart Get/Store Point Data Get History Get/Send Message Transfer/Message Files Access Journals Obtain CG Status Data Link The user program must support either the Bisynch or HDLC link protocol and link restart procedures. The remaining functions below are optional, depending on the intended applications. Data For Get- and Store-Data calls, the values are requested either by single point.parameter names or in data definition tables that are defined and built by the user in the host computer. Sixteen-character point names are supported. The tables contain ASCII data point and parameter names that will be fetched from and stored to the TDC 3000 X system. The CG converts the contents of these tables to internal identifiers that are used in actual data transfers. Real values are returned in engineering unit format. Status of data collected, as well as status of the call, is also returned. Up to 300* parameters can be collected or stored using a single table. * Some data types are restricted to under 300 parameters per transaction, due to specific limitations on the maximum message size on the LCN. Once built, these tables are stored in the host computer. Copies can also reside in the CG for use with Get-Data calls. The CG also supports the accessing of Custom Data Segment arrays using a single call. Storing data is handled in a similar manner to collecting data either single point, whole arrays, or data definition tables can be used. There are several levels of security provided to assure proper access control for writing data to the LCN and its associated UCNs or Data Hiways. Writes can be prevented at the process device, UCN/Hiway, and program level. Program security is host-program dependent. Users may also want to provide several modes for host programs to operate, such as test, restricted, and normal processing. The CG allows host-programs to operate in all of the above nodes; implementation is up to the user. History Continuous history data from History s, including fast history data, can also be obtained by the computer. This includes not only PV values, but other real parameters selected for historization by the History. Both snapshots and averages can be accessed. Historical data for up to 24 parameters can be obtained in a single call. History can be

Page 5 accessed in relative or absolute time. Min/max data is also available. Messages Computer programs can send messages to the Universal Station operator by way of the CG. Such messages optionally may require confirmation by the operator. This allows the computer programs to request an action and to be suspended until a confirmation is received from the operator that the requested action has been completed. Other devices on the LCN can send character-string messages to individual application programs in the computer. These messages are received by the CG and held, pending a transfer request by the application program. File Transfer and Management Application programs running in the host computer can read and write files on the LCN History. Utilities are provided for support functions such as file copy, file re-naming, creation and deletion of files and directories in user-created volumes, moving files from one directory to another, and listing volume and file attributes. History Journal Access An application program in the host computer may also retrieve the history journal events from an LCN. History journals include system journals (i.e., System Status, System Maintenance, System Errors and Status Notification Journals) and process journals (i.e., Process Alarms, Operator Messages, Process Changes, and Sequence-of-Events journals). Either complete journals can be retrieved or a specific time interval may be specified. Specific events can also be selectively extracted from the journals, using various filters. Gateway Database Visibility of computer operation at the Universal Station is provided by a CG database, which can also be accessed by using the datacollection and storage facilities described above. This database consists of the following types of information: Advanced Control Interface Data Points (ACIDPs) Calculated Results Data Points (CRDPs) Both of these can have optional custom data segments that hold data that is associated with computer programs. For example, the results calculated by an optimization program can be stored in a data point's custom data segment. The results are then available to the operator at a Universal Station, for historization in the History, for calculations by the Application, etc. In addition, each ACIDP is associated with a computer program and represents that program's status to the LCN. Each ACIDP also contains security information about its associated program, which allows the program's access to TDC 3000 X data to be restricted; for example, to read only. Up to 250 ACIDPs and up to 500 CRDPs can reside in a CG. Each point can accommodate up to 10 custom data segments, each segment can contain 250 parameters, and each parameter can consist of a 1000-element array (assuming adequate memory is available). Scheduling Computer Programs Computer programs can be scheduled to run from the LCN. They can be configured to run on a cyclic, periodic, and/or demand basis. ACIDPs provide a convenient method of activating programs in the host computer. s on the LCN can request computer programs represented by ACIDPs to run. These requests can be initiated by an operator at a Universal Station, or by an event recognized in a Interface, a Hiway Gateway or an Application. Configuration Options A host computer can be connected to more than one CG. When more than one computer is to be interfaced to a TDC 3000 X system, at least one CG is required for each computer. A combination of CGs totaling up to 10 may be connected to a single LCN. More than one LCN may be connected to a computer, but there must be a serial-communications link and a CG for each connection. Physical Description The CG is currently supplied from the factory as a module (boardset) that installs in a dual node cardfile (electronics chassis). For additional information on the dual node cardfile (DNCF) see System Technical Data. The CG boardset consists of a dual node power supply, a Communications Line Interface (CLI) board, a CLI I/O board, and a LCN processor board. A choice of two LCN processor boards are available: K4LCN (68040 microprocessor) and K2LCN (68020 microprocessor). The K4LCN version requires R500 (or higher) LCN system software, while the K2LCN version is compatible with R320 (or higher) LCN system software. The CG connects to the Local Control through standard LCN coaxial connectors. The computer communications link uses multiconductor cables with an RS422, Type RS449 interface. Maximum cable length for the RS422 signal is 1000 feet.

Page 6 Computer Gateway Specifications Physical Characteristics Approximate Dimensions (In Dual Node Cardfile) Approximate Weight Height 18.8 cm (7") Dual Node Cardfile with: Width 48.3 cm (19") Single Node 14.6 kg (32 lb) Depth 53.3 cm (21") Two Nodes 18 kg (40 lb) Power Supply Universal AC Input 120-264 VAC (autoranging power supply) 47-63 Hz (frequency range) All Computer Gateways operate without disruption through an interruption in the input ac voltage of up to 40 ms duration. Data Link Specifications (Computer Gateway to Host Computer) Protocol Physical Presentation Bisynch or HDLC RS449 (RS422 signal), up to 76.8 k baud (Bisynch), up to 57.6 k baud (HDLC) One or two Bisynch links (half-duplex*) One HDLC Link (full-duplex) *Although 'full-duplex' hardware is used, the link is effectively 'half-duplex', because of the Bisynch protocol. Point-to-point ASCII Character Strings (LSB, MSB); Floating Point (1-bit sign, 7-bit biased characteristic, 24-bit mantissa); Integer (16-bit) Operating Characteristics Point Capacity 250 Advanced Control Interface Data Points (ACIDPs) 500 Calculated Results Data Points (CRDPs) 40 Data Access Tables (CG-resident) Configuration Capability Maximum Number of CGs per LCN 10

Page 7 Computer Gateway Specifications (continued) CE Conformity (Europe) This product is in conformity with the protection requirements of the following European Council Directives: 73/23/EEC, the Low Voltage Directive, and 89/336/EEC, the EMC Directive. Conformity of this product with any other CE Mark Directive(s) shall not be assumed. Deviation from the prescribed procedures and conditions specified in the installation manuals may invalidate this product s conformity with the Low Voltage and EMC Directives. Product Classification Installation Category Pollution Degree EMC Classification Method of Assessment Class I: Permanently mounted, permanently connected Industrial Control Equipment with protective earthing (grounding). (EN 61010-1-1993) Category II: Energy-consuming equipment supplied from the fixed installation. Local Level Appliances and Industrial Control Equipment. (EN 61010-1-1993) Pollution Degree 2: Normally non-conductive pollution with occasional conductivity caused by condensation. (IEC 664-1-1992) Group 1, Class A, Industrial, Scientific and Medical (ISM) Equipment. (EN55011-1991; Emissions) EMC: Technical Construction File (TCF) LVD: Technical File (TF)

Page 8 Copyright, Trademarks, and Notices The following are trademarks of Honeywell Inc.: TDC 3000 system All other brand or product names appearing herein are trademarks of their respective companies or organizations. While this information is presented in good faith and believed to be accurate, Honeywell disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer. In no event is Honeywell liable to anyone for any indirect, special or consequential damages. The information and specificatio ns in this document are subject to change without notice. Printed in U.S.A. Copyright 1996 - Honeywell Inc.